92×92×38mm - sanyo denki europe s.a.

Report 3 Downloads 42 Views
AC Fan

92

■ Features

Low Power Consumption Power consumption is reduced by approximately 44% compared with our conventional AC fan.*

High Airflow and Static Pressure The maximum airflow of the San Ace 92AD type is approximately 1.5 times and the maximum static pressure is approximately 2.3 times higher than that of our conventional AC fan. *

Long Life The San Ace 92AD type has an expected life of 60,000 hours (approximately 6 years), approximately 2.4 times that of our conventional AC fan.*

Wide Range A rated voltage range of 100 to 240 VAC allows for usage in both 100 VAC and 200 VAC systems. Rotation speed remains constant even at different input voltages. *: Our conventional AC fan is 92 x 92 x 25 mm“San Ace 92” , Model No. 109S091 (50Hz 100V).

92×92×38mm ■ Specifications The model no. below has ribs and no sensors. For models without ribs, append "1" to the model no. Model No.

9AD0901H12

Operating Operating (Note) Rated current Rated input Rated speed Max. Airflow Max. Static pressure SPL Rated voltage Expected life temperature voltage range Frequency [min-1] [m3/min] [CFM] [Pa] [inchH2O] [dB(A)] [V] [A] [W] [h] [Hz] [V] [℃]

100 to 240 90 to 264

50 / 60

9AD0901M12

0.08

4.5

3,850

1.50

53.0

90

0.36

40

0.06

3.0

3,100

1.18

41.7

56

0.22

33

-20 to +75 60,000 / 60 ℃

Note: 50/60 Hz compatible.

The model no. below has ribs and low-speed sensors. For models without ribs, append "1" to the model no. Model No.

9AD0901H1H

Operating Operating (Note) Rated current Rated input Rated speed Max. Airflow Max. Static pressure SPL Rated voltage Expected life temperature voltage range Frequency [min-1] [m3/min] [CFM] [Pa] [inchH2O] [dB(A)] [V] [A] [W] [h] [Hz] [V] [℃]

100 to 240 90 to 264

9AD0901M1H

50 / 60

0.08

4.5

3,850

1.50

53.0

90

0.36

40

0.06

3.0

3,100

1.18

41.7

56

0.22

33

-20 to +75 60,000 / 60 ℃

Note: 50/60 Hz compatible.

■ Common Specifications □ Material ・・・・・・・・・・・・・・・・・・・・・・・・・・ Frame: Plastics (Flammability: UL94V-0), Impeller: Plastics (Flammability: UL94V-0) □ Expected Life ・・・・・・・・・・・・・・・・・・・・・ Refer to specifications (L10: Survival rate: 90% at 60 ℃, rated voltage, and continuously run in a free air state) □ Motor Protection System ・・・・・・・・・・ Burnout protection at locked rotor condition □ Dielectric Strength ・・・・・・・・・・・・・・・・ 50/60 Hz, 1,500 VAC, 1 minute (between power terminal and frame or between lead conductor and frame) □ Sound Pressure Level (SPL) ・・・・・・・・ Expressed as the value at 1 m from air inlet side □ Operating Temperature ・・・・・・・・・・・・ Refer to specifications (Non-condensing) □ Storage Temperature ・・・・・・・・・・・・・・ -30 ℃ to +75 ℃ (Non-condensing) □ Mass ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Approx. 250 g

92 ■ Airflow - Static Pressure Characteristics

→ Static pressure

0.4

0.3

(Pa)

(inch H2O)

0.25

100

0.20

80

60 0.2 40 0.1

0

(Pa)

60 50

100 to 240 V 50 / 60 Hz

→ Static pressure

(inch H2O)

0.15

30 0.10 20 0.05

20

0

0.4 0

0.8

10

20

1.2

30

40

1.6 50

100 to 240 V 50 / 60 Hz

40

0

(m3 /min)

60 (CFM)

10

0

0.4 0

10

0.8 20

→ Airflow

1.2

30

40

(m3 /min)

1.6 50

60 (CFM)

→ Airflow

9AD0901H12 9AD0901H1H

9AD0901M12 9AD0901M1H

Standard

with Sensor

AC Power supply

AC Power supply

■ Wiring Diagram

FAN

FAN Photocoupler

Yellow

10 mA max. +27.6 V max.

Pull-up resistor

Senser output Black GND (0 V)

■ Specifications for Low-speed Sensors Typical standard model: 9AD0901H1H Output circuit: Open collector

Sensor scheme

VCE=+27.6 V DC max. Ic=10 mA max.[VCE (SAT) =1.0 V max.] Inside of DC fan

Example 1: when steady running Fan power

Pull-up voltage +27.6 V DC max.

Trip point

Fan speed Pull-up resistor

Photocoupler Sensor

Ic=10 mA max.

Sensor output (VCE)

Startup delay Sensor output

Detection delay

H

H

- ○

L VCE (SAT) = 1.0 V max.

Example 2: when the rotor is locked when the fan motor is turned on and released after the start-up delay time. Fan power

Trip point

Fan speed

Startup delay Sensor output

Detection delay

H

H L

9AD0901H1H

9AD0901M1H

Startup delay: 18±3 sec.

Startup delay: 36±3 sec.

Detection delay: 3 sec. max.

Detection delay: 3 sec. max.

Trip point: 1,700 min-1

Trip point: 850 min-1

92×92×38mm ■ Dimensions (unit: mm) (With ribs) Standard

92±0.5 82.5±0.3

4-φ4.3±0.3 Mounting Hole

(4)

82.5±0.3 92±0.5

Rotating direction

Airflow direction

with Sensor

100±10

Connector: Tyco Electronics 171822-2 (Pin1 Sensor output: Yellow Pin2 -: Black) Contact: Tyco Electronics 170262-1 Lead wire AWG24 UL1007

82.5±0.3

4-φ4.3±0.3 Mounting Hole

92±0.5

(4)

38±0.5

* Recommended connectors and contacts are listed below. Connector: Tyco Electronics 172211-2 Contact: Tyco Electronics 170376-1

(4)

82.5±0.3

(4) 38±0.5

92±0.5

Rotating direction

Airflow direction

■ Reference Dimension of Mounting Holes and Vent Opening (unit: mm) Inlet Side

Outlet Side

90.5

90.5 4-φ4.5

4-φ4.5

97

82.5±0.3

5

10

90.5

82.5±0.3

φ

82.5±0.3

90.5

φ

82.5±0.3

■ Option (unit: mm) Plug cord Model: 489-1635-L10, 489-1635-L21 Products compliant with Electrical Appliance and Material Safety Law, UL/CSA [c-UL] Certified UL FILE No.E43202 10 8

Model Power cord length (L) [mm] Mass [g] 489-1635-L10 1,000 38 489-1635-L21 2,100 74

L

8

15.5

Pre-soldered

4

10 20

4

50± 5

17

10± 2

Resin filter kits Model: 109-1001F13 (13PPI), 109-1001F20 (20PPI), 109-1001F30 (30PPI), 109-1001F40 (40PPI) 96.5 ± 1

10.5 ± 0.5

4-φ4.3±0.3

4-2± 0.5

4-φ9.5±0.5

Finger guards Model: 109-099C

Mass: 25 g

Color

Surface treatment: Nickel-chrome plating (silver)

Color

Model: 109-099E Surface treatment: Nickel-chrome plating (silver) : 109-099H  : Cation electropainting (black) Inlet side, Outlet side

7 φ8

φ 16 . .6 16 φ1

.6 16 φ1

Mass: 22 g

+1

5  0

4.3±0.3 φ1.6 φ1.6 120.5 +1.5 -0.5

4.3±0.3 φ1.6 φ1.6 9.8 φ3 87 φ

5 +10

99

+1.5 120.5 ー0.5

Outlet side

99

96.5 ± 1

82.5 ± 0.3

82.5 ± 0.3

2

Mass: 29 g

Notice

●Please read the "Safety Instructions" on our website once you have decided on a product for use. ●The products shown in this catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited. ●To protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. 3-33-1, Minami-Otsuka, Toshima-ku, Tokyo, 170-8451, Japan TEL: +81 3 5927 1020

http://www.sanyodenki.com

The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. “San Ace” is a trademark of SANYO DENKI CO.,LTD. Specifications are subject to change without notice. CATALOG No. C1051B001 ‘15.6