Amana Technical Information³Refrigerator SRD26V
SRD26VP • •
P1315201W E P1315201W L P1315201W W P1315204W E
SXD26V
P1315202W E P1315202W L P1315202W W
SZD26V
P1315207W E P1315207W L P1315207W W
Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this refrigerator. Refer to Service Manual RS1300004 for installation, disassembly, icemaker, safety, testing, and troubleshooting information.
! CAUTION All safety information must be followed as provided in Service Manual RS1300004.
! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Model Capacity Electrical requirements separate circuit Refrigerant type Width without side extrusions Depth without handle (includes door extrusions) Height (including top hinge cap)
SRD26V 25.8 cu ft 115 VAC 60 Hz 15 amps R134a 35.75
SXD26V 25.8 cu ft 115 VAC 60 Hz 15 amps R134a 35.75
SZD26V 25.8 cu ft 115 VAC 60 Hz 15 amps R134a 35.75
32.5
32.5
32.5
68.5
68.5
68.5
No Load Performance, Controls in Normal Position Kw/24 hr ±0.4
Ambient °F SXD26V SRD26V SZD26V
65° 1.6 1.4 1.6
90° 3 2.5 3
110° 5 4 5
Percent Run Time ±10%
65° 35 34 35
90° 63 60 63
110° 100 100 100
Cycles/24 hr ±25%
65° 35 31 35
90° 23 23 23
110° 0 0 0
Refrigerator Center Compartment Food Average Temperature ±3°F 65° 90° 110° 38 41 41 36 37 35 38 41 41
Freezer Compartment Food Average Temperature ±3°F 65° 3 2 3
90° 2 1 2
110° 2 -3 2
Temperature Relationship Test Chart T-1 Outlet ±3°F Ambient °F SXD26V SRD26V SZD26V
October 2000
65° -15 -14 -15
T-1 Inlet ±3°F 90° -17 -17 -17
65° -18 -20 -18
T-3 Suction Line ±7°F 90° -15 -16 -15
65° 72 73 72
90° 105 98 105
1
Average Total Wattage ±10% 65° 173 156 173
90° 183 165 183
Suction Pressure ±2 PSIG 65° 0 0 0
Head Pressure ±5 PSIG 90° 1 1 1
65° 83 82 83
90° 133 131 133
RT1300039 Rev. 2
Component Specifications
! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Illustration A0282803
Component Bulb, upper refrigerator/freezer
A3079001
Test Procedure Volt Watt
115/125 VAC 40 watts
Bulb, lower refrigerator Used on: SRD26V
Volt Watt
115/125 VAC 40 watts
M0360001
Bulb, cavity light
Volt Watt
115/125 VAC 6 watts
C8931604
Capacitor, compressor run Used on: SRD26V
Volt Capacitance
220 VAC 15 Mfd +10% -5%
C8931605
Capacitor, auger motor
Volt Capacitance
220 VAC 17 Mfd +10% -5%
C8931608
Capacitor, compressor run Used on: SZD26V
Volt Capacitance
210/220 VAC 15 Mfd +10% -5%
12049706
Compressor
Type BTUH Volt Watt Current Lock rotor Full load Resistance Run Windings Start Windings
Fan Cooled, R134a refrigerant 970 BTUH 115 VAC, 60 Hz 196 watts
Type BTUH Volt Watt Current Lock rotor Full load Resistance Run Windings Start Windings
Fan Cooled, R134a refrigerant 970 BTUH 115 VAC, 60 Hz 170 watts
Used on: SXD26V
12049708
Compressor Used on: SRD26V
RT1300039 Rev. 2
2
25.5 amps 2.4 amps 1.88 ohms 8.73 ohms
21.3 amps 1.6 amps 2.60 ohms 4.35 ohms
October 2000
Component Specifications
! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Illustration 12049712
Component Compressor Used on: SZD26V
Test Procedure Type BTUH Volt Watt Current Lock rotor Full load Resistance Run Windings Start Windings
Fan Cooled, R134a refrigerant 970 BTUH 115 VAC, 60 Hz 196 watts 25.5 amps 2.4 amps 1.88 ohms 8.73 ohms
D7547411
Control, damper
Settings #1 #4 #7
Closing temperatures 47F 40F 30F
R0161092
Control, freezer temperature
Settings #1²in #1²out #4²in #4²out #7²in #7²out
Temperatures 21.0F 4.5F 13.3F -5.9F 9.8F -11.0F
B2150504
Drier
Drier must be changed every time the system is opened for testing or compressor replacement.
Desiccant
10882108
Heater, cavity Used on: SRD26V & SXD26V
(20) 8 x 12 4AXH - 7 M>S> -Grams
Volt Wattage Resistance
115 VAC 2 ±5% watts 6.61K ±7.5% ohms
12049801
Heater, evaporator
Volt Wattage Resistance
115 VAC 450 5% watts 29 5% ohms
10114805
Motor, auger
Volt Rotation (facing end opposite shaft)
115 VAC, 60 Hz Power to blue and white leads is clockwise Power to white and orange leads is counterclockwise
RPM Watt Bimetal cut-out Opens Closes
13–17 RPM 165–175 watts
October 2000
3
266° ±9°F 185° ±9°F
RT1300039 Rev. 2
Component Specifications
! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Illustration 10884501
10513803
10377015
Component Motor, condenser
Test Procedure Volt Rotation (facing end opposite shaft) RPM Watt Current Resistance
Motor, evaporator fan
Overload, 4TM Used on: SRD26V
10377023
Overload, 4TM Used on: SXD26V & SZD26V
10097202
Relay, ptc
115 VAC, 60 Hz Clockwise 1300 RPM 10.0 watts 0.15 amps 220 10% ohms
Volt Rotation (facing end opposite shaft) RPM Watt
115 VAC, 60 Hz
Volt Ult. Trip amps @ 158°F (70°C) Close temperature Open temperature Short time trip (seconds) Short time trip (amps @77°F (25°C)
115 VAC 3.51 amps 142°F (61°C) ±9° 257°F (125°C) ±5° 10 seconds 5 14 amps
Volt Ult. Trip amps @ 158°F (70°C) Close temperature Open temperature Short time trip (seconds) Short time trip (amps @77°F (25°C)
115 VAC 3.51 amps 142°F (61°C ±9°) 230°F (110°C ±9°) 10 seconds ±5 16 amps
Clockwise 2500 RPM 12 15% watts
Resistance With power off check: Across terminals 2 & 3 Shorted Open
4²6 ohms 0 ohms Very high or infinite ohms
10166002
Switch, crushed/cubed
Type Volt Current
SPDT 125 VAC 6 amps
12466102
Switch, refrigerator light
Type Volt Current
DPST, NC 125 VAC 5.0 amps
12466101
Switch, freezer light/auger interlock
Type Volt Current
SPDT, NC 125/250 VAC 5.0/5.0 amps
RT1300039 Rev. 2
4
October 2000
Component Specifications
! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Illustration 12419601
Component Switch, limit
Test Procedure Type Volt Current
SPST, NO 125/250 VAC 10.0 amps
10166101
Switch, cavity light
Type Volt Current
SPST 250 VAC 2 amps
D7854104
Switch, photosensitive Used on: SRD26V
Rated load Rated voltage Output Input Operating voltage range Minimum Nominal Maximum Resistance
10 watts
Volt Watt Current Resistance across terminals Above 48° ±5°F Below 15° ±7°F Between 48° ±5°F and 15° ±7°F
120/240 VAC 1000 watts 10/5 amps
Volt Defrost period (minutes) Defrost cycle (hours)
120 VAC, 60 Hz 33 3.6 8
12017823
10530703
Thermostat
Timer, defrost
125 VAC 125 VAC 108 VAC 115 VAC 132 VAC 350 (x10K) ohms
Open Closed Will stay in current state (either open or closed) until either 48° ±6°F or 15° ±8°F is reached.
1
3
4
2
NEUTRAL HOT COMPRESSOR
12313403
12313404
October 2000
Valve, water (primary)
Valve, water (secondary)
Volt Watt Purple coil Brown coil Water pressure (inlet) Max Min Fill rate
120 VAC, 60 Hz
Volt Watt Purple coil Brown coil Water pressure (inlet) Max Min Fill rate
120 VAC, 60 Hz
5
DEFROST
20 watts 20 watts 120 PSI 20 PSI 137 +14 -24 CC at 7.5 seconds
20 watts 20 watts 120 PSI 20 PSI 137 +14 -24 CC at 7.5 seconds
RT1300039 Rev. 2
Troubleshooting
! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. ICE FILL TUBE ICE MAKER 1/4" O.D. PLASTIC TUBING
WATER FILTER INLET WALTER FILTER OUTLET
ICE & WATER DISPENSER HOUSEHOLD WATER LINE CONNECTION 1/4" O.D. COPPER TUBE COMPRESSION FITTING PRIMARY SOLENOID VALVE WATER DISPENSER COIL (PURPLE) SECONDARY SOLENOID VALVE INLET
PRIMARY SOLENOID VALVE ICEMAKER COIL (BROWN)
WATER TANK
SECONDARY SOLENOID VALVE WATER DISPENSER COIL (PURPLE)
1/4" O.D. X 5/16" O.D. PLASTIC COMPRESSION UNION SECONDARY SOLENOID VALVE ICEMAKER COIL (BROWN)
RT1300039 Rev. 2
6
October 2000
Troubleshooting
! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper earthing and polarization. Component Door Gasket
Location Door gaskets foamed in place between inner door liner and door pan during manufacturing.
Replacement Procedure If gasket is damaged, replace with appropriate service gasket kit (see Parts Manual for kit part numbers) following instructions in kit.
Refrigerator and Freezer Doors
Foamed as an assembly during manufacturing.
Inner door liner and outer door pan are not replaceable. If damaged, entire door must be replaced.
Water Line
Water line to dispenser runs through conduit in freezer door.
Water Head Assembly and Filter
To replace water line: 1. Remove toe grille. 2. Remove plastic union nut at water-line splice below freezer door and pull water line out of "P" clip. 3. Attach nylon cord or fishing line to one end of water line. 4. Pull water line out of conduit from bottom being sure to leave end of cord dangling. Attach new water line to free end of cord and pull water line through conduit using cord to draw new water line into place. To remove water filter bracket and filter head assembly: Unit is shipped with bypass plug in water 1. Loosen two screws securing water filter bracket to fresh food liner. head assembly and filter canister in 2. Slide bracket with filter head forward approximately ½". Bracket assembly crisper. will drop down as screw heads reach keyhole slots. Water filter bypass plug should be retained 3. Unscrew filter head from bracket. in case filter becomes water plugged and a 4. Detach water lines from filter head by pushing down on collars while new filter is not immediately available. pulling tubing out. To remove bypass or filter from head assembly, turn bypass or filter ¼ turn to left and pull down. It is not necessary to turn water off to unit in order to make a filter change.
Water Dispenser Rates Seconds to dispense 10 Oz. Water Supply Pressure Filter model with bypass installed. Filter model with new filter installed.
20 psig*
30 psig*
40 psig*
50 psig*
60 psig*
70 psig*
18.1
14.3
12.2
10.8
9.8
9.0
22.0
17.3
14.2
12.8
11.5
10.4
*Amana specifies a minimum supply pressure of 35 psig for water filter units. Minimum pressure requirement is to insure water valves close and sufficient water volume is available to fill ice maker. Proper fill is 140 cc. Of water in 7.5 seconds. Failure of water valves to close because of low pressure will result in fill tube freeze up or dripping at cavity. .
October 2000
7
RT1300039 Rev. 2
Schematic Drawing
! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
SRD26V
SRD26VP
P1315201W E P1315201W L P1315201W W P1315204W E
RT1300039 Rev. 2
SXD26V
P1315202W E P1315202W L P1315202W W
8
SZD26V
P1315207W E P1315207W L P1315207W W
October 2000
Wiring Diagram
! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
SRD26V
SRD26VP October 2000
P1315201W E P1315201W L P1315201W W P1315204W E
SXD26V
P1315202W E P1315202W L P1315202W W 9
SZD26V
P1315207W E P1315207W L P1315207W W RT1300039 Rev. 2