Amana Technical Information³Refrigerator ! CAUTION ! WARNING

Report 20 Downloads 224 Views
Amana Technical Information³Refrigerator SRD26V

SRD26VP • •

P1315201W E P1315201W L P1315201W W P1315204W E

SXD26V

P1315202W E P1315202W L P1315202W W

SZD26V

P1315207W E P1315207W L P1315207W W

Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this refrigerator. Refer to Service Manual RS1300004 for installation, disassembly, icemaker, safety, testing, and troubleshooting information.

! CAUTION All safety information must be followed as provided in Service Manual RS1300004.

! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Model Capacity Electrical requirements separate circuit Refrigerant type Width without side extrusions Depth without handle (includes door extrusions) Height (including top hinge cap)

SRD26V 25.8 cu ft 115 VAC 60 Hz 15 amps R134a 35.75

SXD26V 25.8 cu ft 115 VAC 60 Hz 15 amps R134a 35.75

SZD26V 25.8 cu ft 115 VAC 60 Hz 15 amps R134a 35.75

32.5

32.5

32.5

68.5

68.5

68.5

No Load Performance, Controls in Normal Position Kw/24 hr ±0.4

Ambient °F SXD26V SRD26V SZD26V

65° 1.6 1.4 1.6

90° 3 2.5 3

110° 5 4 5

Percent Run Time ±10%

65° 35 34 35

90° 63 60 63

110° 100 100 100

Cycles/24 hr ±25%

65° 35 31 35

90° 23 23 23

110° 0 0 0

Refrigerator Center Compartment Food Average Temperature ±3°F 65° 90° 110° 38 41 41 36 37 35 38 41 41

Freezer Compartment Food Average Temperature ±3°F 65° 3 2 3

90° 2 1 2

110° 2 -3 2

Temperature Relationship Test Chart T-1 Outlet ±3°F Ambient °F SXD26V SRD26V SZD26V

October 2000

65° -15 -14 -15

T-1 Inlet ±3°F 90° -17 -17 -17

65° -18 -20 -18

T-3 Suction Line ±7°F 90° -15 -16 -15

65° 72 73 72

90° 105 98 105

1

Average Total Wattage ±10% 65° 173 156 173

90° 183 165 183

Suction Pressure ±2 PSIG 65° 0 0 0

Head Pressure ±5 PSIG 90° 1 1 1

65° 83 82 83

90° 133 131 133

RT1300039 Rev. 2

Component Specifications

! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Illustration A0282803

Component Bulb, upper refrigerator/freezer

A3079001

Test Procedure Volt Watt

115/125 VAC 40 watts

Bulb, lower refrigerator Used on: SRD26V

Volt Watt

115/125 VAC 40 watts

M0360001

Bulb, cavity light

Volt Watt

115/125 VAC 6 watts

C8931604

Capacitor, compressor run Used on: SRD26V

Volt Capacitance

220 VAC 15 Mfd +10% -5%

C8931605

Capacitor, auger motor

Volt Capacitance

220 VAC 17 Mfd +10% -5%

C8931608

Capacitor, compressor run Used on: SZD26V

Volt Capacitance

210/220 VAC 15 Mfd +10% -5%

12049706

Compressor

Type BTUH Volt Watt Current Lock rotor Full load Resistance Run Windings Start Windings

Fan Cooled, R134a refrigerant 970 BTUH 115 VAC, 60 Hz 196 watts

Type BTUH Volt Watt Current Lock rotor Full load Resistance Run Windings Start Windings

Fan Cooled, R134a refrigerant 970 BTUH 115 VAC, 60 Hz 170 watts

Used on: SXD26V

12049708

Compressor Used on: SRD26V

RT1300039 Rev. 2

2

25.5 amps 2.4 amps 1.88 ohms 8.73 ohms

21.3 amps 1.6 amps 2.60 ohms 4.35 ohms

October 2000

Component Specifications

! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Illustration 12049712

Component Compressor Used on: SZD26V

Test Procedure Type BTUH Volt Watt Current Lock rotor Full load Resistance Run Windings Start Windings

Fan Cooled, R134a refrigerant 970 BTUH 115 VAC, 60 Hz 196 watts 25.5 amps 2.4 amps 1.88 ohms 8.73 ohms

D7547411

Control, damper

Settings #1 #4 #7

Closing temperatures 47ƒF 40ƒF 30ƒF

R0161092

Control, freezer temperature

Settings #1²in #1²out #4²in #4²out #7²in #7²out

Temperatures 21.0ƒF 4.5ƒF 13.3ƒF -5.9ƒF 9.8ƒF -11.0ƒF

B2150504

Drier

Drier must be changed every time the system is opened for testing or compressor replacement.

Desiccant

10882108

Heater, cavity Used on: SRD26V & SXD26V

(20) 8 x 12 4AXH - 7 M>S> -Grams

Volt Wattage Resistance

115 VAC 2 ±5% watts 6.61K ±7.5% ohms

12049801

Heater, evaporator

Volt Wattage Resistance

115 VAC 450 “5% watts 29 “5% ohms

10114805

Motor, auger

Volt Rotation (facing end opposite shaft)

115 VAC, 60 Hz Power to blue and white leads is clockwise Power to white and orange leads is counterclockwise

RPM Watt Bimetal cut-out Opens Closes

13–17 RPM 165–175 watts

October 2000

3

266° ±9°F 185° ±9°F

RT1300039 Rev. 2

Component Specifications

! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Illustration 10884501

10513803

10377015

Component Motor, condenser

Test Procedure Volt Rotation (facing end opposite shaft) RPM Watt Current Resistance

Motor, evaporator fan

Overload, 4TM Used on: SRD26V

10377023

Overload, 4TM Used on: SXD26V & SZD26V

10097202

Relay, ptc

115 VAC, 60 Hz Clockwise 1300 RPM 10.0 watts 0.15 amps 220 “10% ohms

Volt Rotation (facing end opposite shaft) RPM Watt

115 VAC, 60 Hz

Volt Ult. Trip amps @ 158°F (70°C) Close temperature Open temperature Short time trip (seconds) Short time trip (amps @77°F (25°C)

115 VAC 3.51 amps 142°F (61°C) ±9° 257°F (125°C) ±5° 10 seconds “5 14 amps

Volt Ult. Trip amps @ 158°F (70°C) Close temperature Open temperature Short time trip (seconds) Short time trip (amps @77°F (25°C)

115 VAC 3.51 amps 142°F (61°C ±9°) 230°F (110°C ±9°) 10 seconds ±5 16 amps

Clockwise 2500 RPM 12 “15% watts

Resistance With power off check: Across terminals 2 & 3 Shorted Open

4²6 ohms 0 ohms Very high or infinite ohms

10166002

Switch, crushed/cubed

Type Volt Current

SPDT 125 VAC 6 amps

12466102

Switch, refrigerator light

Type Volt Current

DPST, NC 125 VAC 5.0 amps

12466101

Switch, freezer light/auger interlock

Type Volt Current

SPDT, NC 125/250 VAC 5.0/5.0 amps

RT1300039 Rev. 2

4

October 2000

Component Specifications

! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Illustration 12419601

Component Switch, limit

Test Procedure Type Volt Current

SPST, NO 125/250 VAC 10.0 amps

10166101

Switch, cavity light

Type Volt Current

SPST 250 VAC 2 amps

D7854104

Switch, photosensitive Used on: SRD26V

Rated load Rated voltage Output Input Operating voltage range Minimum Nominal Maximum Resistance

10 watts

Volt Watt Current Resistance across terminals Above 48° ±5°F Below 15° ±7°F Between 48° ±5°F and 15° ±7°F

120/240 VAC 1000 watts 10/5 amps

Volt Defrost period (minutes) Defrost cycle (hours)

120 VAC, 60 Hz 33 “3.6 8

12017823

10530703

Thermostat

Timer, defrost

125 VAC 125 VAC 108 VAC 115 VAC 132 VAC 350 (x10K) ohms

Open Closed Will stay in current state (either open or closed) until either 48° ±6°F or 15° ±8°F is reached.

1

3

4

2

NEUTRAL HOT COMPRESSOR

12313403

12313404

October 2000

Valve, water (primary)

Valve, water (secondary)

Volt Watt Purple coil Brown coil Water pressure (inlet) Max Min Fill rate

120 VAC, 60 Hz

Volt Watt Purple coil Brown coil Water pressure (inlet) Max Min Fill rate

120 VAC, 60 Hz

5

DEFROST

20 watts 20 watts 120 PSI 20 PSI 137 +14 -24 CC at 7.5 seconds

20 watts 20 watts 120 PSI 20 PSI 137 +14 -24 CC at 7.5 seconds

RT1300039 Rev. 2

Troubleshooting

! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. ICE FILL TUBE ICE MAKER 1/4" O.D. PLASTIC TUBING

WATER FILTER INLET WALTER FILTER OUTLET

ICE & WATER DISPENSER HOUSEHOLD WATER LINE CONNECTION 1/4" O.D. COPPER TUBE COMPRESSION FITTING PRIMARY SOLENOID VALVE WATER DISPENSER COIL (PURPLE) SECONDARY SOLENOID VALVE INLET

PRIMARY SOLENOID VALVE ICEMAKER COIL (BROWN)

WATER TANK

SECONDARY SOLENOID VALVE WATER DISPENSER COIL (PURPLE)

1/4" O.D. X 5/16" O.D. PLASTIC COMPRESSION UNION SECONDARY SOLENOID VALVE ICEMAKER COIL (BROWN)

RT1300039 Rev. 2

6

October 2000

Troubleshooting

! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper earthing and polarization. Component Door Gasket

Location Door gaskets foamed in place between inner door liner and door pan during manufacturing.

Replacement Procedure If gasket is damaged, replace with appropriate service gasket kit (see Parts Manual for kit part numbers) following instructions in kit.

Refrigerator and Freezer Doors

Foamed as an assembly during manufacturing.

Inner door liner and outer door pan are not replaceable. If damaged, entire door must be replaced.

Water Line

Water line to dispenser runs through conduit in freezer door.

Water Head Assembly and Filter

To replace water line: 1. Remove toe grille. 2. Remove plastic union nut at water-line splice below freezer door and pull water line out of "P" clip. 3. Attach nylon cord or fishing line to one end of water line. 4. Pull water line out of conduit from bottom being sure to leave end of cord dangling. Attach new water line to free end of cord and pull water line through conduit using cord to draw new water line into place. To remove water filter bracket and filter head assembly: Unit is shipped with bypass plug in water 1. Loosen two screws securing water filter bracket to fresh food liner. head assembly and filter canister in 2. Slide bracket with filter head forward approximately ½". Bracket assembly crisper. will drop down as screw heads reach keyhole slots. Water filter bypass plug should be retained 3. Unscrew filter head from bracket. in case filter becomes water plugged and a 4. Detach water lines from filter head by pushing down on collars while new filter is not immediately available. pulling tubing out. To remove bypass or filter from head assembly, turn bypass or filter ¼ turn to left and pull down. It is not necessary to turn water off to unit in order to make a filter change.

Water Dispenser Rates Seconds to dispense 10 Oz. Water Supply Pressure Filter model with bypass installed. Filter model with new filter installed.

20 psig*

30 psig*

40 psig*

50 psig*

60 psig*

70 psig*

18.1

14.3

12.2

10.8

9.8

9.0

22.0

17.3

14.2

12.8

11.5

10.4

*Amana specifies a minimum supply pressure of 35 psig for water filter units. Minimum pressure requirement is to insure water valves close and sufficient water volume is available to fill ice maker. Proper fill is 140 cc. Of water in 7.5 seconds. Failure of water valves to close because of low pressure will result in fill tube freeze up or dripping at cavity. .

October 2000

7

RT1300039 Rev. 2

Schematic Drawing

! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.

SRD26V

SRD26VP

P1315201W E P1315201W L P1315201W W P1315204W E

RT1300039 Rev. 2

SXD26V

P1315202W E P1315202W L P1315202W W

8

SZD26V

P1315207W E P1315207W L P1315207W W

October 2000

Wiring Diagram

! WARNING To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.

SRD26V

SRD26VP October 2000

P1315201W E P1315201W L P1315201W W P1315204W E

SXD26V

P1315202W E P1315202W L P1315202W W 9

SZD26V

P1315207W E P1315207W L P1315207W W RT1300039 Rev. 2