Work Changes Proposal Request Number: 10 Date of Issuance: 06.28.2016 Project: Miller & Watkins Halls Renovations KU #012-10810 & #011-10817 OFPM A-012958 & A-012959 Architect’s Project No: 015022
Contract For: General Construction Contract Date: tbd Acme Building
Owner:
The University of Kansas Office of Design and Construction Mgmt. Department of Student Housing
From:
Clark | Huesemann 927 ½ Massachusetts Street Lawrence, Kansas 66044
To:
MarLan Construction 1008 New Hampshire Street Lawrence, KS 66044
Ow
Please submit an itemized proposal for changes in the Contract Sum and Contract Time for proposed modifications to the Contract Documents described herein. Within Seven (7) days, the Contractor must submit this proposal or notify the Architect, in writing, of the date on which the proposal submission is anticipated. The Owner may accept or reject any or all items.
THIS IS NOT A CHANGE ORDER, A CONSTRUCTION CHANGE DIRECTIVE OR A DIRECTION TO PROCEED WITH THE WORK DESCRIBED IN THE PROPOSED MODIFICATIONS. Description:
Per discussion with Simplex and the University Fire Marshal, see attached modifications to simplify the Fire Alarm System. Attachments:
HEI PR 10 Issued by the Architect:
(Signature)
cla rk | hue s e m a nn LC
Jane Huesemann, Principal
June 28, 2016
(Printed Name and Title)
(Date)
927 1/ 2 Ma s s a chus e tts S t
•
La wre nce , KS 66044
www.cla rkhue s e m a nn.c om
PR NO 10 06/27/2016 ISSUED BY
ISSUED FOR
Henderson Engineers, Inc. 8345 Lenexa Drive, Suite 300 Lenexa, KS 66214
Clark Huesemann 927 ½ Massachusetts St. Lawrence, KS 66044
NOTICE TO ALL BIDDERS FOR THE
KU Miller and Watkins Scholarship Halls KU Campus, Lawrence, KS You are instructed to read and to note the following described changes, corrections, clarifications, omissions, deletions, additions, approvals, and statements pertinent to the Contract Bid and Construction Documents. The PR No. 10 is part of the Contract Bid and Construction Documents and shall govern in the performance of t he Work. DRAWINGS FP101 – FIRE PROTECTION PLAN (WATKINS) - Refer to FP101
Detail 1 – Remove supply duct smoke detector and remote test station in Laundry 011.
Detail 1 – Add Smoke detector in ARC 012A and Trash 013.
Detail 2 – Add Smoke detector in Restroom 105.
Detail 2 – Remove duct smoke detector and Remote Test Station from Restroom103.
Detail 2 – Add Heat detector in Bath 101E
Detail 3 – Remove one supply duct smoke detector and remote test station in Storage 212.
Detail 3 – Revise one supply smoke detector to a return duct smoke detector install in return side of FCU in Storage 212.
Detail 3 – Add Smoke detector to Stair 2S2.
Detail 3 – Add Heat detector in Bath 201A.
Detail 3 – Remove duct smoke detector and Remote Test Station from Restroom203.
Detail 4 – Remove two supply duct smoke detectors and remote test stations in Mech 310.
Detail 4 – Remove two return duct smoke detectors and remote test stations in Mech 310.
Detail 4 – Add two Smoke detectors to Hall 301.
Detail 4 – Remove duct smoke detector and Remote Test Station from Restroom303.
Fire Alarm Plan Notes – Revise plan note #10 to read. “Provide equipment and connections to close smoke damper upon the activation of a smoke or heat detector in the building.”
FP101 – FIRE PROTECTION PLAN (MILLER) - Refer to FP101
Detail 1 – Remove supply duct smoke detector and remote test station from Laundry 011.
Page 2 of 2
Detail 1 – Add Smoke detector in ARC 012A.
Detail 2 – Add Heat detector in Bath 101E
Detail 2 – Add Smoke detector in Restroom 105.
Detail 2 – Remove duct smoke detector and Remote Test Station from Restroom103.
Detail 3 – Remove one supply duct smoke detector and remote test station in Storage 212.
Detail 3 – Revise one supply smoke detector to a return duct smoke detector install in return s ide of FCU in Storage 212.
Detail 3 – Add Smoke detector to Stair 2S2.
Detail 3 – Remove duct smoke detector and Remote Test Station from Restroom203.
Detail 4 – Remove two supply duct smoke detectors and remote test stations in Mech 310.
Detail 4 – Remove two return duct smoke detectors and remote test stations in Mech 310.
Detail 4 – Remove duct smoke detector and Remote Test Station from Restroom303.
Fire Alarm Plan Notes – Revise plan note #10 to read. “Provide equipment and connections to close smoke d amper upon the activation of a smoke or heat detector in the building.”
1
2
3
4
5
6
927 1/2 MASSACHUSETTS ST LAWRENCE, KS 66044 (785) 691-5547
[email protected] SLEEPING PORCH 300
CONSULTANTS M.E.P. ENGINEERS D
8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hei-eng.com 1550002079 KS. CORPORATE NUMBER: E-325 EXPIRES 12/31/16
STUDY 102 STAIR 1S1
STUDY 307
RESTRM 103
CL 304 BATH 101E HALL 101C
BEDRM 101B
MAIL 109
VEST 108
CLOSET 101A
Office of Facilities and Property Management
ISSUE DATE:
C
COMMON 016
SLEEPING PORCH 200
B
Mark McGivern, Director
FOYER 107
PR-10
LIVING 101
06|27|2016
STUDY 308
PR-06
STAIR 1S2
06|10|2016
STUDY 309
SUNRM 110A
ADDENDUM 3
STOR 311
MECH 310
LIVING 110
03|04|2016
STUDY 312
RESTRM 105
HALL 106
Department of Administration 900 Jackson Street, Suite 600 Topeka, KS 66612 (785) 296-8899
KITCHEN 101D
TELEPHONE (785) 864-3431 FAX (785) 864-5644
DESCRIPTION:
HALL 301
STUDY 313
1515 ST. ANDREWS DRIVE LAWRENCE, KANSAS 66047-1619
DATE:
STAIR 3S1
STUDY 306
MARK:
STUDY 305
RESTRM 303
DESIGN & CONSTRUCTION MANAGEMENT THE UNIVERSITY OF KANSAS
02|12|2016
STUDY 302
STUDY 104
RESTRM 203
STAIR BS1
STAIR 2S1
HALL 202
KIT 4 004
TRASH 013
STOR 212
STUDY 210
STUDY 209
KIT 5 005
KIT 6 006
KIT 7 007
HALL 015 F.S. F.S.STOR. STOR. 009 009
KIT 2 002 STUDY 211
STOR 008
STUDY 208
STUDY 207
GEN KIT 012 MECH MECH 010 010
MECH 014 A.R.C. 012A
STAIR 2S2
LAUNDRY 011
A
CHECKED BY: HEI REV:
KIT 3 003
KIT 1 001
DRAWN BY: HEI
STUDY 206
DATE: 02|12|16
STUDY 205
1518 LILAC LN, LAWRENCE, KS 66044 BUILDING NO. 68200-00012 KU PROJECT NO. 012-10810
STUDY 204
UNIVERSITY OF KANSAS
J:\Kansas City\2015\1550002079 Miller and Watkins Scholarship Halls - Lawrence - KS\190\Fire\1550002079 FP101-M.dwg, Plot, 6/27/2016 1:25:51 PM, brian_l, 1:1
STUDY 201
MILLER HALL REPAIRS AND RENOVATIONS
VEST 017
FIRE PROTECTION PLANS
A-012958
FP101
MILLER 1
2
3
4
5
6
100% CONSTRUCTION DOCUMENTS
1
2
3
4
5
6
927 1/2 MASSACHUSETTS ST LAWRENCE, KS 66044 (785) 691-5547
[email protected] SLEEPING PORCH 300
CONSULTANTS M.E.P. ENGINEERS D
8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 66214 TEL 913 742 5000 FAX 913 742 5001 www.hei-eng.com 1550002079 KS. CORPORATE NUMBER: E-325 EXPIRES 12/31/16
RESTRM 103 STUDY 102 STUDY 302
STUDY 305
STUDY 307
STAIR 1S1
1515 ST. ANDREWS DRIVE LAWRENCE, KANSAS 66047-1619
CL 304
HALL 301
BATH 101E
KITCHEN 101D
SUNRM 110A
LIVING 110
STUDY 201 BATH 201A STAIR 2S1
RESTRM 203
STAIR BS1
KIT 4 004
TRASH 013
KIT 5 005
KIT 6 006
KIT 7 007
STOR 008
HALL 202
STOR 212 MECH 014
STUDY 211
ELEC 009
KIT 3 003
KIT 1 001
STUDY 210
STUDY 209
STUDY 208
GEN KIT 012
STOR 008A
HALL 015 MECH 010
STUDY 207 KIT 2 002
A.R.C. 012A
STAIR 2S2
LAUNDRY 011
PR-10
F.S. STOR 010A
A
Mark McGivern, Director CHECKED BY: HEI REV:
STUDY 206
DRAWN BY: HEI
STUDY 205
DATE: 02|12|16
J:\Kansas City\2015\1550002079 Miller and Watkins Scholarship Halls - Lawrence - KS\190\Fire\1550002079 FP101-W.dwg, Plot, 6/27/2016 1:25:55 PM, brian_l, 1:1
STUDY 204
WATKINS HALL REPAIRS AND RENOVATIONS
B
Department of Administration 900 Jackson Street, Suite 600 Topeka, KS 66612 (785) 296-8899
SLEEPING PORCH 200
1506 LILAC LN, LAWRENCE, KS 66044 BUILDING NO. 68200-00011 KU PROJECT NO. 011-10817
ISSUE DATE:
Office of Facilities and Property Management
COMMON 016
06|27|2016
MAIL 109
VEST 108
CLOSET 101A
C
03|04|2016
BEDRM 101B
ADDENDUM 3
FOYER 107
UNIVERSITY OF KANSAS
LIVING 101
DESCRIPTION:
STUDY 308
DATE:
STUDY 309
MARK:
MECH 310
STUDY 312
RESTRM 105
HALL 106
TELEPHONE (785) 864-3431 FAX (785) 864-5644
HALL 101C
STOR 311 STUDY 313
DESIGN & CONSTRUCTION MANAGEMENT THE UNIVERSITY OF KANSAS
02|12|2016
STUDY 3S1
RESTRM 303
STUDY 306
STUDY 104
FIRE PROTECTION PLANS
A-012959
FP101
WATKINS 1
2
3
4
5
6
100% CONSTRUCTION DOCUMENTS