Goto to Main PDF Menu
BRACKETS
(15.9)
2"
A
(50.8)
I
C
I
1"
(25.4)
B
13
⁄16"
(20.6)
7
⁄16"
II
1 5⁄8"
(11.1) Dia.
(41.3) 9
⁄32" (7.1) Dia.
2"
(50.8) II
III
A 3"
C
(76.2)
B
C
In
mm
In
mm
P2491 R-L P2492 R-L P2493 R-L P2494 R-L P2495 R-L P2496 R-L P2497 R-L P2498 R-L P2499 R-L P2500 R-L P2501 R-L P2502 R-L P2503 R-L
6 8 10 12 14 16 18 20 22 24 26 28 30
152.4 203.2 254.0 304.8 355.6 406.4 457.2 508.0 558.8 609.6 660.4 711.2 762.0
115⁄16 27⁄16 215⁄16 37⁄16 315⁄16 47⁄16 415⁄16 57⁄16 515⁄16 67⁄16 615⁄16 77⁄16 715⁄16
49.2 61.9 74.6 87.3 100.0 112.7 125.4 138.1 150.8 163.5 176.2 188.9 201.6
Weight/C
In
mm
Lbs
kg
3 5 7 3 4 5 6 7 8 5 511⁄16 65⁄16 7
76.2 127.0 177.8 76.2 101.6 127.0 152.4 177.8 203.2 127.0 144.5 160.3 177.8
67 92 120 152 173 223 266 308 355 400 445 493 545
30.4 41.7 54.4 68.9 78.5 101.2 120.7 139.7 161.0 181.4 201.8 223.6 247.2
Material : 12 Gage Steel.
C
B 5⁄8"
A
Part Number
1"
(15.9)
(25.4)
Pipe/Conduit Supports
13
⁄16"
(20.6)
7
⁄16" (11.1) Dia. 9 ⁄32" (7.1) Dia. 1 5⁄8"
(41.3)
⁄8"
A C
(15.9)
3"
B
(76.2) Vertical Channel
C 1" (25.4)
Part No.
Gage
P1000 P1100 P2000
12 14 16
13
⁄16"
(20.6)
9
⁄32" (7.1) Dia.
7
⁄16" (11.1) Dia.
1 5⁄8" (41.3) * Allowable moment for fitting only. Channel may determine overall capacity.
P1075 4 ⁄4"
Safety Factor - 21⁄2 * Allowable moment for fitting only. Channel may determine overall capacity.
P15931
1 ⁄16" (27.0)
4 3 ⁄4 "
(120.7)
(120.7)
3"
4 5⁄8" (117.5)
(76.2) Vertical Channel
Material: 1⁄4" (6.4) thick steel. Wt/C 229 Lbs (103.9 kg)
13 16"
P1000 P1100 P2000 P4001
5 7⁄8" (149.2)
⁄ Framing
P1001 P1101 P5000 P2001
7 1 ⁄2 " (190.5)
Part No.
Gage
P1000 P1100 P2000
12 14 16
Allowable Moment* In-Lbs N•m 5100 4400 3200
Part No.
Gage
Allowable Moment* In-Lbs N•m
P1000 P1100 P2000
12 14 16
13000 1470 9100 1030 6500 730
Vertical Channel
576 500 360
Material: 1⁄4" (6.4) thick steel.
Safety Factor - 21⁄2
Wt/C 272 Lbs (123.4 kg)
Safety Factor - 21⁄2
NOTE
Index
(27.0)
3
Uniform Design Load Lbs kN 300 1.3 250 1.1 200 0.9
Concrete Inserts
3" (76.2)
5
Electrical Fittings
R - As shown L - Opposite hand
C
11⁄4" Framing System
III
System
2"
(50.8)
1 1⁄16"
Nuts & Hardware
Illustration
⁄8"
Spec. Metals & Fiberglass
5
General Fittings
P2491 R-L thru P2503 R-L
1 5/8" Channels
FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL
When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.
107
Return to #12 TOC
Return to Fittings TOC
Goto to Main PDF Menu
GENERAL FITTINGS
Electrical Fittings
Pipe/Conduit Supports
General Fittings
Nuts & Hardware
1 5/8" Channels
FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL
Page Flat Plate Fittings
82
Ninety Degree Fittings
86
Angular Fittings
93
“Z” Shape Fittings
94
“U” Shape Fittings
96
Wing Shape Fittings
101
Post Bases Brackets and Braces Beam Clamps Trolleys Special Application Fittings
Index
Spec. Metals & Fiberglass
13⁄16"
Framing System
11⁄4" Framing System
Concrete Inserts
End Caps Partition and Display Fittings
105 106 112 122 124 126 127
MATERIAL Fittings, unless noted, are made from hot-rolled, pickled and oiled steel plates, strip or coil, and conform to ASTM specifications A575, A576, A635, or A36. The fitting steel also meets the physical requirements of ASTM A570 GR 33. The pickling of the steel produces a smooth surface free from scale. Many fittings are also available in stainless steel, aluminum and fiberglass. Consult factory for ordering information. FINISHES Fittings are available in: PermaGreen II (GR), electro-galvanized
(EG), conforming to ASTM B633 Type III SC1; Hot-dipped galvanized (HG), conforming to ASTM A123 or A153 and plain (PL). APPLICATION All parts drawings illustrate only one application of each fitting. In most cases many other applications are possible. The channels shown in the illustrations are P1000, 15⁄8" square, except where noted otherwise. All 9⁄16" diameter holes use 1 ⁄2" x 15⁄16" hex head cap screws and 1⁄2" nuts – P1010, P4010 or P5510 – depending on the channel used. Nuts and bolts are not included with the fitting and must be ordered separately.
DESIGN BOLT TORQUE BOLT SIZE FOOT LBS. N.m
1⁄4" 20
5
⁄8"
5⁄16" 18
3⁄8" 16
1⁄2" 13
11
3⁄4" 10
6
11
19
50
100
125
8
15
25
70
135
170
DIMENSIONS Imperial dimensions are illustrated in inches. Metric dimensions are shown in parenthesis or as noted. Unless noted, all metric dimensions are in millimeters and rounded to one decimal place. DESIGN LOAD Design load data, where shown, is based on the ultimate strength of the connection with a safety factor of 2.5, unless otherwise noted.
80
Return to #12 TOC
Goto to Main PDF Menu
P1000® & P1001 CHANNELS FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL
3
⁄8"
9.5
22.2
9
⁄32"
9.5
7.1
.915" 1 .710"
1 5⁄8"
23.3 1 18.0
41.3
2
2
Pierced channels are found on pages 60 and 61.
Weight: 190 Lbs/C Ft (283 kg/100 m)
P1001
Nuts & Hardware
⁄8"
41.3
1 5⁄8" 7 ⁄8"
General Fittings
3
1 5/8" Channels
P1000
41.3
3 1⁄4"
Pipe/Conduit Supports
1 5⁄8"
82.6
1
Electrical Fittings
1
Concrete Inserts
2
2
Weight: 380 Lbs/C Ft (566 kg/100 m)
3500
11⁄4" Framing System
3000
P1000 P1001 2000 1500
⁄ Framing
LOAD (Lbs)
2500
13 16"
1000 500
36
48
60
72
84
*Maximum allowable uniform load.
Channel
Weight
Allowable Moment
96 108 120 132 144 156 168 180 192 204 216 228 240 SPAN (In)
Material Thickness
Lbs/Ft
kg/m
In-Lb
N•m
In
mm
P1000
1.90
2.8
5,080
570
.105
2.7
P1001
3.80
5.7
14,390
1630
.105
2.7
Standard Lengths 10'
20'
Other Materials
Finishes PL
GR
HG
PG
SS
EA
Index
24
Spec. Metals & Fiberglass
0
System
BEAM LOAD*
Nominal thickness of 12 gage strip steel is .105 inches.
23
Return to #12 TOC
Return to Channel TOC
Goto to Main PDF Menu
P1100TM & P1101 CHANNELS
1 5/8" Channels
FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL
P1100 1 5⁄8" 7 ⁄8"
3
⁄8"
3
⁄8"
9.5
9
⁄32"
Nuts & Hardware
41.3 22.2
.896" 1 .729"
1 5⁄8"
22.8 1 18.5
41.3
2
General Fittings
9.5
7.1
2
Pierced channels are found on pages 60 and 61.
Weight: 142 Lbs/C Ft (211 kg/100 m)
Pipe/Conduit Supports
P1101 1 5⁄8"
41.3
3 1⁄4"
82.6
1
Electrical Fittings
1
Concrete Inserts
2
2 Weight: 284 Lbs/C Ft (423 kg/100 m)
BEAM LOAD*
2000
11⁄4" Framing System
1800
Framing System
LOAD (Lbs)
1600 1400
P1100
1200
P1101
1000 800 600
13⁄16"
400 200
Spec. Metals & Fiberglass
0 24
36
48
60
72
84
96 108 120 132 144 156 168 180 192 204 216 228 240 SPAN (In)
*Maximum allowable uniform load.
Index
Channel
Weight Lbs/Ft
kg/m
P1100
1.42
2.1
P1101
2.84
4.2
Allowable Moment In-Lb
Material Thickness
N•m
In
mm
4,170
470
.075
1.9
11,470
1300
.075
1.9
Standard Lengths 10'
20'
Other Materials
Finishes PL
GR
HG
PG
SS
EA
Nominal thickness of 14 gage strip steel is .075 inches.
32
Return to #12 TOC
Return to Channel TOC
Goto to Main PDF Menu
P2000TM & P2001 CHANNELS
1 5/8" Channels
FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL
P2000 3
⁄8"
1 5⁄8" 7 ⁄8"
3
⁄8"
9.5
9
Nuts & Hardware
⁄32" .890" 1 .735"
22.6 1 18.7
41.3
2
General Fittings
9.5
7.1
1 5⁄8"
Pierced channels are found on pages 60 and 61.
41.3 22.2
2
Weight: 116 Lbs/C Ft (173 kg/100 m)
P2001 Pipe/Conduit Supports
1 5⁄8"
41.3
3 1⁄4"
82.6
1
Electrical Fittings
1
2
Concrete Inserts
2
Weight: 232 Lbs/C Ft (345 kg/100 m)
BEAM LOAD*
1400 1200
P2001
800 600
Framing System
LOAD (Lbs)
11⁄4" Framing System
P2000 1000
400
13⁄16"
200 0
Spec. Metals & Fiberglass
24
36
48
60
72
84
96 108 120 132 144 156 168 180 192 204 216 228 240
SPAN (In) *Maximum allowable uniform load.
Index
Channel
Weight
Allowable Moment N•m
Material Thickness
Lbs/Ft
kg/m
In-Lb
In
mm
P2000
1.16
1.7
3,520
400
.060
1.5
P2001
2.32
3.4
9,530
1080
.060
1.5
Standard Lengths 10'
20'
Other Materials
Finishes PL
GR
HG
PG
SS
EA
Nominal thickness of 16 gage strip steel is .060 inches.
36
Return to #12 TOC
Return to Channel TOC