brackets - Kelly and Hayes

Report 2 Downloads 111 Views
Goto to Main PDF Menu

BRACKETS

(15.9)

2"

A

(50.8)

I

C

I

1"

(25.4)

B

13

⁄16"

(20.6)

7

⁄16"

II

1 5⁄8"

(11.1) Dia.

(41.3) 9

⁄32" (7.1) Dia.

2"

(50.8) II

III

A 3"

C

(76.2)

B

C

In

mm

In

mm

P2491 R-L P2492 R-L P2493 R-L P2494 R-L P2495 R-L P2496 R-L P2497 R-L P2498 R-L P2499 R-L P2500 R-L P2501 R-L P2502 R-L P2503 R-L

6 8 10 12 14 16 18 20 22 24 26 28 30

152.4 203.2 254.0 304.8 355.6 406.4 457.2 508.0 558.8 609.6 660.4 711.2 762.0

115⁄16 27⁄16 215⁄16 37⁄16 315⁄16 47⁄16 415⁄16 57⁄16 515⁄16 67⁄16 615⁄16 77⁄16 715⁄16

49.2 61.9 74.6 87.3 100.0 112.7 125.4 138.1 150.8 163.5 176.2 188.9 201.6

Weight/C

In

mm

Lbs

kg

3 5 7 3 4 5 6 7 8 5 511⁄16 65⁄16 7

76.2 127.0 177.8 76.2 101.6 127.0 152.4 177.8 203.2 127.0 144.5 160.3 177.8

67 92 120 152 173 223 266 308 355 400 445 493 545

30.4 41.7 54.4 68.9 78.5 101.2 120.7 139.7 161.0 181.4 201.8 223.6 247.2

Material : 12 Gage Steel.

C

B 5⁄8"

A

Part Number

1"

(15.9)

(25.4)

Pipe/Conduit Supports

13

⁄16"

(20.6)

7

⁄16" (11.1) Dia. 9 ⁄32" (7.1) Dia. 1 5⁄8"

(41.3)

⁄8"

A C

(15.9)

3"

B

(76.2) Vertical Channel

C 1" (25.4)

Part No.

Gage

P1000 P1100 P2000

12 14 16

13

⁄16"

(20.6)

9

⁄32" (7.1) Dia.

7

⁄16" (11.1) Dia.

1 5⁄8" (41.3) * Allowable moment for fitting only. Channel may determine overall capacity.

P1075 4 ⁄4"

Safety Factor - 21⁄2 * Allowable moment for fitting only. Channel may determine overall capacity.

P15931

1 ⁄16" (27.0)

4 3 ⁄4 "

(120.7)

(120.7)

3"

4 5⁄8" (117.5)

(76.2) Vertical Channel

Material: 1⁄4" (6.4) thick steel. Wt/C 229 Lbs (103.9 kg)

13 16"

P1000 P1100 P2000 P4001

5 7⁄8" (149.2)

⁄ Framing

P1001 P1101 P5000 P2001

7 1 ⁄2 " (190.5)

Part No.

Gage

P1000 P1100 P2000

12 14 16

Allowable Moment* In-Lbs N•m 5100 4400 3200

Part No.

Gage

Allowable Moment* In-Lbs N•m

P1000 P1100 P2000

12 14 16

13000 1470 9100 1030 6500 730

Vertical Channel

576 500 360

Material: 1⁄4" (6.4) thick steel.

Safety Factor - 21⁄2

Wt/C 272 Lbs (123.4 kg)

Safety Factor - 21⁄2

NOTE

Index

(27.0)

3

Uniform Design Load Lbs kN 300 1.3 250 1.1 200 0.9

Concrete Inserts

3" (76.2)

5

Electrical Fittings

R - As shown L - Opposite hand

C

11⁄4" Framing System

III

System

2"

(50.8)

1 1⁄16"

Nuts & Hardware

Illustration

⁄8"

Spec. Metals & Fiberglass

5

General Fittings

P2491 R-L thru P2503 R-L

1 5/8" Channels

FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL

When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.

107

Return to #12 TOC

Return to Fittings TOC

Goto to Main PDF Menu

GENERAL FITTINGS

Electrical Fittings

Pipe/Conduit Supports

General Fittings

Nuts & Hardware

1 5/8" Channels

FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL

Page Flat Plate Fittings

82

Ninety Degree Fittings

86

Angular Fittings

93

“Z” Shape Fittings

94

“U” Shape Fittings

96

Wing Shape Fittings

101

Post Bases Brackets and Braces Beam Clamps Trolleys Special Application Fittings

Index

Spec. Metals & Fiberglass

13⁄16"

Framing System

11⁄4" Framing System

Concrete Inserts

End Caps Partition and Display Fittings

105 106 112 122 124 126 127

MATERIAL Fittings, unless noted, are made from hot-rolled, pickled and oiled steel plates, strip or coil, and conform to ASTM specifications A575, A576, A635, or A36. The fitting steel also meets the physical requirements of ASTM A570 GR 33. The pickling of the steel produces a smooth surface free from scale. Many fittings are also available in stainless steel, aluminum and fiberglass. Consult factory for ordering information. FINISHES Fittings are available in: PermaGreen II (GR), electro-galvanized

(EG), conforming to ASTM B633 Type III SC1; Hot-dipped galvanized (HG), conforming to ASTM A123 or A153 and plain (PL). APPLICATION All parts drawings illustrate only one application of each fitting. In most cases many other applications are possible. The channels shown in the illustrations are P1000, 15⁄8" square, except where noted otherwise. All 9⁄16" diameter holes use 1 ⁄2" x 15⁄16" hex head cap screws and 1⁄2" nuts – P1010, P4010 or P5510 – depending on the channel used. Nuts and bolts are not included with the fitting and must be ordered separately.

DESIGN BOLT TORQUE BOLT SIZE FOOT LBS. N.m

1⁄4" 20

5

⁄8"

5⁄16" 18

3⁄8" 16

1⁄2" 13

11

3⁄4" 10

6

11

19

50

100

125

8

15

25

70

135

170

DIMENSIONS Imperial dimensions are illustrated in inches. Metric dimensions are shown in parenthesis or as noted. Unless noted, all metric dimensions are in millimeters and rounded to one decimal place. DESIGN LOAD Design load data, where shown, is based on the ultimate strength of the connection with a safety factor of 2.5, unless otherwise noted.

80

Return to #12 TOC

Goto to Main PDF Menu

P1000® & P1001 CHANNELS FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL

3

⁄8"

9.5

22.2

9

⁄32"

9.5

7.1

.915" 1 .710"

1 5⁄8"

23.3 1 18.0

41.3

2

2

Pierced channels are found on pages 60 and 61.

Weight: 190 Lbs/C Ft (283 kg/100 m)

P1001

Nuts & Hardware

⁄8"

41.3

1 5⁄8" 7 ⁄8"

General Fittings

3

1 5/8" Channels

P1000

41.3

3 1⁄4"

Pipe/Conduit Supports

1 5⁄8"

82.6

1

Electrical Fittings

1

Concrete Inserts

2

2

Weight: 380 Lbs/C Ft (566 kg/100 m)

3500

11⁄4" Framing System

3000

P1000 P1001 2000 1500

⁄ Framing

LOAD (Lbs)

2500

13 16"

1000 500

36

48

60

72

84

*Maximum allowable uniform load.

Channel

Weight

Allowable Moment

96 108 120 132 144 156 168 180 192 204 216 228 240 SPAN (In)

Material Thickness

Lbs/Ft

kg/m

In-Lb

N•m

In

mm

P1000

1.90

2.8

5,080

570

.105

2.7

P1001

3.80

5.7

14,390

1630

.105

2.7

Standard Lengths 10'

20'

Other Materials

Finishes PL

GR

HG

PG

SS

EA

Index

24

Spec. Metals & Fiberglass

0

System

BEAM LOAD*

Nominal thickness of 12 gage strip steel is .105 inches.

23

Return to #12 TOC

Return to Channel TOC

Goto to Main PDF Menu

P1100TM & P1101 CHANNELS

1 5/8" Channels

FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL

P1100 1 5⁄8" 7 ⁄8"

3

⁄8"

3

⁄8"

9.5

9

⁄32"

Nuts & Hardware

41.3 22.2

.896" 1 .729"

1 5⁄8"

22.8 1 18.5

41.3

2

General Fittings

9.5

7.1

2

Pierced channels are found on pages 60 and 61.

Weight: 142 Lbs/C Ft (211 kg/100 m)

Pipe/Conduit Supports

P1101 1 5⁄8"

41.3

3 1⁄4"

82.6

1

Electrical Fittings

1

Concrete Inserts

2

2 Weight: 284 Lbs/C Ft (423 kg/100 m)

BEAM LOAD*

2000

11⁄4" Framing System

1800

Framing System

LOAD (Lbs)

1600 1400

P1100

1200

P1101

1000 800 600

13⁄16"

400 200

Spec. Metals & Fiberglass

0 24

36

48

60

72

84

96 108 120 132 144 156 168 180 192 204 216 228 240 SPAN (In)

*Maximum allowable uniform load.

Index

Channel

Weight Lbs/Ft

kg/m

P1100

1.42

2.1

P1101

2.84

4.2

Allowable Moment In-Lb

Material Thickness

N•m

In

mm

4,170

470

.075

1.9

11,470

1300

.075

1.9

Standard Lengths 10'

20'

Other Materials

Finishes PL

GR

HG

PG

SS

EA

Nominal thickness of 14 gage strip steel is .075 inches.

32

Return to #12 TOC

Return to Channel TOC

Goto to Main PDF Menu

P2000TM & P2001 CHANNELS

1 5/8" Channels

FOR 15⁄8" (41 MM) WIDTH SERIES CHANNEL

P2000 3

⁄8"

1 5⁄8" 7 ⁄8"

3

⁄8"

9.5

9

Nuts & Hardware

⁄32" .890" 1 .735"

22.6 1 18.7

41.3

2

General Fittings

9.5

7.1

1 5⁄8"

Pierced channels are found on pages 60 and 61.

41.3 22.2

2

Weight: 116 Lbs/C Ft (173 kg/100 m)

P2001 Pipe/Conduit Supports

1 5⁄8"

41.3

3 1⁄4"

82.6

1

Electrical Fittings

1

2

Concrete Inserts

2

Weight: 232 Lbs/C Ft (345 kg/100 m)

BEAM LOAD*

1400 1200

P2001

800 600

Framing System

LOAD (Lbs)

11⁄4" Framing System

P2000 1000

400

13⁄16"

200 0

Spec. Metals & Fiberglass

24

36

48

60

72

84

96 108 120 132 144 156 168 180 192 204 216 228 240

SPAN (In) *Maximum allowable uniform load.

Index

Channel

Weight

Allowable Moment N•m

Material Thickness

Lbs/Ft

kg/m

In-Lb

In

mm

P2000

1.16

1.7

3,520

400

.060

1.5

P2001

2.32

3.4

9,530

1080

.060

1.5

Standard Lengths 10'

20'

Other Materials

Finishes PL

GR

HG

PG

SS

EA

Nominal thickness of 16 gage strip steel is .060 inches.

36

Return to #12 TOC

Return to Channel TOC