NOTE: This Drawing should be used in addition to each products respective Installation Manual. (not in place of)
DISPLAY
POWER 12/24V AC/DC
The following items are part of the WC-10 package: - CX-33 Relay - CX-MDC Door Contacts - CM-400/8 Push-to-Lock switch The following items shown are required, but not included: - Door Operator - Electric Strike - (2) Activate (wall) switches - 12 / 24V power supply
Fail-Safe Electric Strike Shown
Magnetic Contact Switch
(If Fail-Secure lock is used, wire to Terminals 1 & 2) Wire MOV (supplied) directly to strike or magnet
WC-10 Washroom Package Wiring Diagram (normally unlocked) DRAWING No: DRG-CX-WC-10-7 For Normally Locked Door, see over...
FILENAME:
WC-10-7 wiring diagram.vsd
LED 1
0.0.8
2
3
4
5
6
7
8
9
LED 2
12 / 24 VDC Power For Strike
Inside Wall Switch (always unlocks & opens door)
CM-400/8 Push to Lock Switch
N/O
Door Operator
-
N.C. Contacts closed when Door is closed
PUSH TO LOCK
N/C
COM
+
C
Outside Keypad, Key switch, Prox reader or similar
N/O
N/C
COM
DOWN
Relay 3
N/O
UP
Relay 2
N/C
MENU
Relay 1 COM
- INPUT
INPUT
+ WET
LED 3 DRY 4
DRY 3
INPUT
DRY 2
INPUT
DRY 1
INPUT
CX-33
12 - 24 V AC/DC Power
1
NOTE: This Drawing should be used in addition to each products respective Installation Manual. (not in place of)
DISPLAY
POWER 12/24V AC/DC
The following items are part of the WC-10 package: - CX-33 Relay - CX-MDC Door Contacts - CM-400/8 Push-to-Lock switch The following items shown are required, but not included: - Door Operator - Electric Strike - (2) Activating devices - 12 / 24V power supply
Fail-Secure Electric Strike Shown
Magnetic Contact Switch
(If Fail-Safe lock is used, wire to Terminals 1 & 2) Wire MOV (supplied) directly to strike or magnet