Camden Door Controls CX-33 0.0.7

Report 32 Downloads 106 Views
LED 1

0.0.7

12 / 24 VDC Power For Strike

Inside Wall Switch (always unlocks & opens door)

CM-400/8 Push to Lock Switch

N/O

+ Door Operator

-

N.C. Contacts closed when Door is closed

PUSH TO LOCK

N/C

COM

N/O

N/C

COM

DOWN

Relay 3

N/O

UP

Relay 2

N/C

MENU

Relay 1 COM

- INPUT

INPUT

+ WET

DRY 4

DRY 3

LED 2 LED 3

INPUT

DRY 2

INPUT

DRY 1

INPUT

CX-33

12 - 24 V AC/DC Power

Outside Wall Switch

NOTE: This Drawing should be used in addition to each products respective Installation Manual. (not in place of)

DISPLAY

POWER 12/24V AC/DC

The following items are part of the WC-10 package: - CX-33 Relay - CX-MDC Door Contacts - CM-400/8 Push-to-Lock switch The following items shown are required, but not included: - Door Operator - Electric Strike - (2) Activate (wall) switches - 12 / 24V power supply

Fail-Safe Electric Strike Shown

Magnetic Contact Switch

(If Fail-Secure lock is used, wire to Terminals 1 & 2) Wire MOV (supplied) directly to strike or magnet

MOV

Camden Door Controls SCALE: NONE

DRAWN BY: DGW

DATE: 07/22/14

5502 Timberlea Blvd Mississauga, Ontario L4W 2T7 REVISED:

WC-10 Washroom Package Wiring Diagram (normally unlocked) DRAWING No: DRG-CX-WC-10-7 For Normally Locked Door, see over...

FILENAME:

WC-10-7 wiring diagram.vsd

LED 1

0.0.8

2

3

4

5

6

7

8

9

LED 2

12 / 24 VDC Power For Strike

Inside Wall Switch (always unlocks & opens door)

CM-400/8 Push to Lock Switch

N/O

Door Operator

-

N.C. Contacts closed when Door is closed

PUSH TO LOCK

N/C

COM

+

C

Outside Keypad, Key switch, Prox reader or similar

N/O

N/C

COM

DOWN

Relay 3

N/O

UP

Relay 2

N/C

MENU

Relay 1 COM

- INPUT

INPUT

+ WET

LED 3 DRY 4

DRY 3

INPUT

DRY 2

INPUT

DRY 1

INPUT

CX-33

12 - 24 V AC/DC Power

1

NOTE: This Drawing should be used in addition to each products respective Installation Manual. (not in place of)

DISPLAY

POWER 12/24V AC/DC

The following items are part of the WC-10 package: - CX-33 Relay - CX-MDC Door Contacts - CM-400/8 Push-to-Lock switch The following items shown are required, but not included: - Door Operator - Electric Strike - (2) Activating devices - 12 / 24V power supply

Fail-Secure Electric Strike Shown

Magnetic Contact Switch

(If Fail-Safe lock is used, wire to Terminals 1 & 2) Wire MOV (supplied) directly to strike or magnet

MOV

Camden Door Controls SCALE: NONE

DRAWN BY: DGW

DATE: 07/22/14

5502 Timberlea Blvd Mississauga, Ontario L4W 2T7 REVISED:

WC-10 Washroom Package Wiring Diagram (normally locked) DRAWING No: DRG-CX-WC-10-8 For Normally Unlocked Door, see over...

FILENAME:

WC-10-8 wiring diagram.vsd