ChiefExperts.com Contemporary House Addition Working Drawings

Report 1 Downloads 39 Views
5/12

2-1/2/12

North Elevation 1/8' = 1'0"

East Elevation 1/8' = 1'0"

South Elevation 1/8' = 1'0"

West Elevation 1/8' = 1'0"

Plans Drawn With: Chief Architect DATE: 08-12-2002 PAGE

1

of

6

DESIGN/BUILD TECHNOLOLGY, INC. 12304 JUNCTION ROAD MINNETONKA, MN 55343 800-688-0306 WWW.DBTEC.COM

PLAN DRAWN FOR:

HANSEN HOMETECH 7920 KERBER BLVD. CHANHASSEN, MN 55317 952-934-0854

ELEVATIONS AND FULL OVERVIEWS

5 6" 12'-3"

18'-3" CAN'T ABOVE

INSULATE EXTERIOR WALLS

NEW UTILITY 35 sq ft

2X4 WALLS WITH 5/8' FIRE ROCK

2'-0"

14'-8"

FURN.

5'-7"

32" MTL. FIRE DOOR 8" X 42" FLARED POST FOOTING

6'-7" EXISTING LOWER LEVEL WALLS

INSTALL 2X6 JOISTS OVER 2" DOW FOAM INSUALTION WITH FIBERGLASS INSUALTION AND 3/4" PLYWOOD FLOOR

ADD NEW STAIRS FOR THE UPPER LEVEL

GARAGE

7'-1"

688 sq ft

UP

5'11

6'-2"

5'-0"

6'-0"

6

CAN'T ABOVE

MAIN LEVEL PLAN 1/4' = 1'0"

Plans Drawn With: Chief Architect DATE: 08-12-2002 PAGE

2

of

6

DESIGN/BUILD TECHNOLOLGY, INC. 12304 JUNCTION ROAD MINNETONKA, MN 55343 800-688-0306 WWW.DBTEC.COM

PLAN DRAWN FOR:

HANSEN HOMETECH 7920 KERBER BLVD. CHANHASSEN, MN 55317 952-934-0854

MAIN FLOOR PLAN 1/4" = 1'

UPPER WINDOW RO=3'10-1/2" W x 1'5-5/8" H

5

UPPER WINDOW RO=3'10-1/2" W x 2'5-5/8" H

30'-6"

3/12 vaulted ceiling

7'-6"

UPPER WINDOW RO=3'10-1/2" W x 3'5-5/8" H

12'-4"

18'-1"

2'-5"

3'-6"

1'-7"

UPPER WINDOW RO=3'10-1/2" W x 4'5-5/8" H

RO=3'0-1/2" W x 4'5-3/8" H AR41 P4060

A351 P4060

P4045 P4060

P4035 P4060

2'-0"

CXW145

WALL BELOW

LOWER WINDOW RO=3'10-1/2" W x 5'9-5/8" H tub REMOVE WINDOWS

12'-9"

9'-9"

LOWER WINDOW RO=3'10-1/2" W x 5'9-5/8" H

6

3'-0"

2868

EXISTING

CUSTOM BUILT CIRCULAR STAIRWAY. ADD BLOCKING IN FLOOR AS PER MANUFACTURER SPECIFICATIONS

14'-9"

FAMILY ROOM BEDROOM

shower

2'-6"

double lav

6'-3"

P4035

3'-9"

2868

3'-0"

5068

12'-4"

4'-5"

DN

6'-7"

DN 2468

RO=???

3'-3"

" -5 4'

4'-5"

3'-4"

12'-9"

8

WALL BELOW

1'-8" 7" 6 20

6'-0"

7'-7"

BATH

CLOSET

6'-1"

2668

5'-1"

8'-7"

BEDROOM 9'-9"

27'-11"

5068

6'-4"

RO=4'0-1/2" W x 2'0-5/8" H

RO=4'0-1/2" W x 2'0-5/8" H

CXW145

A41

A41

A41

RO=3'0-1/2" W x 4'5-3/8" H

12'-4"

2'-7"

12'-4"

2'-7" 5'-1"

2'-5"

4'-11" 9'-10"

2'-6" 2'-9"

UPPER LEVEL PLAN 1/4' = 1'0"

Plans Drawn With: Chief Architect DATE: 08-12-2002 PAGE

3

of

6

DESIGN/BUILD TECHNOLOLGY, INC. 12304 JUNCTION ROAD MINNETONKA, MN 55343 800-688-0306 WWW.DBTEC.COM

PLAN DRAWN FOR:

HANSEN HOMETECH 7920 KERBER BLVD. CHANHASSEN, MN 55317 952-934-0854

2ND LEVEL FLOOR PLAN 1/4" = 1'

3'-1"

18'-0"

P4040 A41

LOWER WINDOW RO= 4'0-1/2" W x 4'0-1/2' H

4'-0"

UPPER WINDOW RO= 4'0-1/2" W x 2'0-5/8' H

490 sq ft

11'-11"

5'-6"

OPEN BELOW LOWER WINDOW RO= 4'0-1/2" W x 2'0-5/8' H

5'-6"

18'-9"

A41 A41

CUSTOM BUILT CIRCULAR STAIRWAY. ADD BLOCKING IN FLOOR AS PER MANUFACTURER SPECIFICATIONS. VERIFY ALL DIMENSIONS

12'-0"

3'-0"

2'-10"

2X4 FRAMED RAILINGS WITH 1/2" DRYWALL

5'-6"

7"

2'-9" KNEE WALL

A41

1'-8"

8'-9"

UPPER WINDOW RO= 4'0-1/2" W x 2'0-5/8' H

5'-6"

A41

2 X 8 FLOOR JOISTS 16" OC

28'-2"

A41

28'-2"

RO= 4'0-1/2" W x 2'0-5/8' H

7'-1"

P4040 A41

9'-5"

WALLS BELOW

3'-1"

LOWER WINDOW RO= 4'0-1/2" W x 4'0-1/2' H

1'-8"

16'-4"

P4040 A41

UPPER WINDOW RO= 4'0-1/2" W x 2'0-5/8' H

18'-0"

LOFT AREA PLAN 1/4' = 1'0"

LOFT AREA FRAMING PLAN 1/4' = 1'0"

Plans Drawn With: Chief Architect DATE: 08-12-2002 PAGE

4

of

6

DESIGN/BUILD TECHNOLOLGY, INC. 12304 JUNCTION ROAD MINNETONKA, MN 55343 800-688-0306 WWW.DBTEC.COM

PLAN DRAWN FOR:

HANSEN HOMETECH 7920 KERBER BLVD. CHANHASSEN, MN 55317 952-934-0854

3RD LEVEL FLOOR PLAN 1/4" = 1'

5

12 5/8" DRYWALL WITH VAPOR BARRIER

2 - 1-3/4" X 24' LAM BEAMS LAG BOLTED TO EXISTING WALL FRAMING

2'-0"

1/2' ROOF SHEATHING ICE AND WATER SHIELD SHINGLES TO MATCH EXISTING AS CLOSE AS POSSIBLE VENTILATION TO CODE

2.5

2 - 1-3/4" X 24' LAM BEAMS OR MANUFACTURED GIRDER TRUSSES

2 - 1-3/4" X 24' LAM BEAMS

R-38 INSULATION

1 - 1-3/4' X 24" LAM BEAM RIM JOIST

OVERHANG TO MATCH EXISTING AS CLOSE AS POSSIBLE

JOIST HANGERS PER MANUFACTURER

ADD NEW STAIRS FOR THE UPPER LEVEL

FTR-1

FTR-1

FTR-1

FTR-1

FTR-1

FTR-1

FTR-2

(VERIFY)

VERIFY EXISTING FOOTINGS UNDER GARAGE WALL AT LOAD POINTS

EXISTING LOWER LEVEL WALLS

(VERIFY)

EXISTING GARAGE

FTR-1

EXISTING GARAGE WALLS

FTR-1

24' FLOOR TRUSSES 24" OC AS PER MANUFACTURER SPECIFICATIONS

23'-11"

PLYWOOD ON BOTTOM OF CANT

FTR-1

1-3/4" X 24" LAM BEAM RIM JOIST 5/8" FIREROCK

FTR-1

3/4" T&G PLYWOOD FLOOR SHEATHING

FTR-1

CANT SUPPORT OF FLOOR TRUSSES PER MANUFACTUERE SPECIFICATIONS

EXISTING GARAGE WALLS

FURN.

FTR-2

6 2X6 WALL FRAMING 16' OC 25/32 BUILT RITE HOUSE WRAP WOOD SIDING (TO MATCH EXISTING AS CLOSE AS POSIBLE) R-19 FF INSULATION INTERIOR VAPOR BARRIER 1/2" DRYWALL

24' MANUFACTURED FLOOR TRUSSES 24' OC

2X4 INTERRIOR WALL FRAMING WITH 1/2" DRYWALL

R-38 INSULATION

FIELD VERIFY EXISTING FOOTING AT THIS POINT

5

12

UP

CROSS SECTION 1/4" = 1'0" FTR-3 1'-9" 2'-10"

7'-6"

MAIN LEVEL FRAMING PLAN 1/4" = 1'0"

3'-0"

10"

2'-0"

(VERIFY)

FTR-3

5'11

Plans Drawn With: Chief Architect DATE: 08-12-2002 PAGE

5

of

6

DESIGN/BUILD TECHNOLOLGY, INC. 12304 JUNCTION ROAD MINNETONKA, MN 55343 800-688-0306 WWW.DBTEC.COM

PLAN DRAWN FOR:

HANSEN HOMETECH 7920 KERBER BLVD. CHANHASSEN, MN 55317 952-934-0854

12

WALL BELOW

5 R-38 INSULATION 1/2' ROOF SHEATHING ICE AND WATER SHIELD SHINGLES TO MATCH EXISTING AS CLOSE AS POSSIBLE VENTILATION TO CODE

6

tub 14' LPI RAFTERS 24" OC

5/8" DRYWALL WITH VAPOR BARRIER

7'-10 1/2"

OVERHANG TO MATCH EXISTING AS CLOSE AS POSSIBLE

19'-8 1/2"

MANUFACTUERED ROOF TRUSSES 24" OC

TR-0

TR-0

TR-0

TR-0

double lav

2X4 INTERIOR WALL FRAMING WITH 1/2" DRYWALL

DN

8'-8"

12'-4"

shower

TR-0

7'-5"

TR-0

LOFT LINES

2X6 WALL FRAMING 16' OC 25/32 BUILT RITE HOUSE WRAP WOOD SIDING (TO MATCH EXISTING AS CLOSE AS POSIBLE) R-19 FF INSULATION INTERIOR VAPOR BARRIER 1/2" DRYWALL

TR-0

ROOF TRUSSES PER MANUFACTURER

DN 3/4" T&G PLYWOOD FLOOR SHEATHING

BOLT 1-3/4" LAM BEAM TO EXISTING WALL

R-38 INSULATION

24' FLOOR TRUSSES 24" OC AS PER MANUFACTURER SPECIFICATIONS

NEW FURNACE ROOM INSULATE EXISTING GARAGE WALLS IN THE FURNACE ROOM

5/8" FIREROCK ON GARAGE CEILING

WALL BELOW

2 1-3/4" X 24" LAM BEAM RIM JOISTS OR MANUFACTUER GIRDER TRUSS

2X4 WALL WITH 5/8" DRYWALL ON 2 SIDES 3/4' T&G PLYWOOD FLOORING

EXISTING GARAGE 2X8 FLOOR JOISTS 16' OC WITH R27 FF INSULATION DOUBLE 2 X 8 RIM JOISTS ON A 2X4 TREATED PLATE

2" DOW FOAM INSULATION

EXISTING CONCRETE FLOOR

UPPER LEVEL FRAMING PLAN 1/4" = 1'0"

METAL "J" BOLT 8' X 42" FLARED POST FOOTING

VERIFY EXISTING FOOTINGS UNDER GARAGE WALL AT LOAD POINTS

CROSS SECTION 1/4' = 1'0"

Plans Drawn With: Chief Architect DATE: 08-12-2002 PAGE

6

of

6

DESIGN/BUILD TECHNOLOLGY, INC. 12304 JUNCTION ROAD MINNETONKA, MN 55343 800-688-0306 WWW.DBTEC.COM

PLAN DRAWN FOR:

HANSEN HOMETECH 7920 KERBER BLVD. CHANHASSEN, MN 55317 952-934-0854