All BQ/BQH/HBQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix “L” to catalog number. Consult Siemens for any additional charge. All standard circuit breakers are calibrated for 40°C maximum ambient application. Continuous Current Rating @ 40° C

Type BQ

Type BQH

Type HBQ

10,000A IR

22,000A IR

65,000A IR

Catalog Number

Catalog Number

Catalog Number

1-Pole (120V AC)e 15 20 25 30 35 40 45 50 60 70

BQ1B015d BQ1B020d BQ1B025 BQ1B030 BQ1B035n BQ1B040 BQ1B045n BQ1B050 BQ1B060n BQ1B070n

2-Pole (Common-Trip 120/240V 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125

BQ2B015 BQ2B020 BQ2B025 BQ2B030 BQ2B035 BQ2B040 BQ2B045 BQ2B050 BQ2B060 BQ2B070 BQ2B080 BQ2B090 BQ2B100 BQ2B110 BQ2B125

2-Pole (Common-Trip 240V

1-Pole

HB2B015n HB2B020n HB2B025n HB2B030n HB2B035n HB2B040n HB2B045n HB2B050n HB2B060n HB2B070n HB2B080 HB2B090n HB2B100 HB2B110n HB2B125

— — — — — — — — — —

— — — — — — — — — —

BQ3B015H BQ3B020H BQ3B025Hn BQ3B030H BQ3B035H BQ3B040H BQ3B045H BQ3B050H BQ3B060H BQ3B070H BQ3B080Hn BQ3B090Hn BQ3B100H

HB3B015n HB3B020n HB3B025 HB3B030 HB3B035 HB3B040 HB3B045 HB3B050 HB3B060 HB3B070n HB3B080n HB3B090n HB3B100

2-Pole

3-Pole

3-Pole (Common-Trip 240V AC)g 15 20 25 30 35 40 45 50 60 70 80 90 100

BQ3B015 BQ3B020 BQ3B025n BQ3B030 BQ3B035n BQ3B040 BQ3B045n BQ3B050 BQ3B060 BQ3B070 BQ3B080 BQ3B090 BQ3B100

BQ / BQH / HBQ Internal Accessories Description 120V Shunt Trip 24V Shunt Trip 120V Auxiliary Switch

Catalog Number Field/Factory Installed add suffix...00S01n Factory add suffix...00S07n Factory add suffix...01nb Factory

n Built to order. Allow 2-3 weeks for delivery a UL

Listed for use with 60/75° wire through 40 amps, UL listed for use with 75° wire only for 50 amps and above, HACR rated.

Product Category MCCB

b 1A c UL

MOLDED CASE CIRCUIT BREAKERS

BQ2H015 BQ2H020 BQ2H030 BQ2H040n BQ2H050 BQ2H060 BQ2H070n BQ2H080n BQ2H090n BQ2H100n

BQ2B015H BQ2B020H BQ2B025Hn BQ2B030H BQ2B035Hn BQ2B040H BQ2B045Hn BQ2B050H BQ2B060H BQ2B070Hn BQ2B080Hn BQ2B090Hn BQ2B100H BQ2B110H BQ2B125H AC)cf

HB1B015nd HB1B020nd HB1B025n HB1B030n HB1B035n HB1B040n HB1B045n HB1B050n HB1B060n HB1B070n

7

15 20 30 40 50 60 70 80 90 100

BQ1B015Hd BQ1B020Hd BQ1B025Hn BQ1B030H BQ1B035Hn BQ1B040H BQ1B045Hn BQ1B050H BQ1B060Hn BQ1B070Hn AC)f

Factory Modifications Description Catalog Number Line Side Lugs add suffix...L Quick Connect Lug add suffix...QX 400Hz Calibration add suffix...Y h Marine 50˚ C Ambient add suffix...M Calibration Fungus Proofing add suffix...F

For external accessories, please refer to page 7-93

and 1B contacts. Listed for use on 3-phase grounded “B” systems ­­— 10,000 for this application. d UL Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting.

e Shipped 12 per sleeve. f Shipped 6 per sleeve. g Shipped 4 per sleeve. h UL Listed 5KA IR.

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

7-37

• Revised • 03/06/13

Molded Case Circuit Breakers DIN Rail Mounted Circuit Breakers Breaker Type

Ampere Rating

Catalog Number

Load Side Connector

1-Pole DIN Rail (120V AC) 10 15 20 25 30 35 40 45 50 60 10 15 20 25 30 35 40 45 50 60

BQXD 1-Pole 120V DIN Rail

BQ1B010QLD BQ1B015QLD BQ1B020QLD BQ1B025QLD BQ1B030QLD BQ1B035QLD BQ1B040QLD BQ1B045QLD BQ1B050QLD BQ1B060QLD BQ1B010QXD BQ1B015QXD BQ1B020QXD BQ1B025QXD BQ1B030QXD BQ1B035QXD BQ1B040QXD BQ1B045QXD BQ1B050QXD BQ1B060QXD

Selection/Dimensions Interrupting Ratings (KA) (RMS Symmetrical Amperes) Volts AC

TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TA1Q1 TA1Q1 TA1Q1 Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect

120

120/240

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

BQ1B015QLD

BQ2B015QLD

BQ1B015QXD

BQ2B015QXD

2-Pole DIN Rail (120/240V AC) 10 15 20 25 30 35 40 45 50 60 10 15 20 25 30 35 40 45 50 60

BQXD

MOLDED CASE CIRCUIT BREAKERS

7

2-Pole 120/240V DIN Rail

BQ2B010QLD BQ2B015QLD BQ2B020QLD BQ2B025QLD BQ2B030QLD BQ2B035QLD BQ2B040QLD BQ2B045QLD BQ2B050QLD BQ2B060QLD BQ2B010QXD BQ2B015QXD BQ2B020QXD BQ2B025QXD BQ2B030QXD BQ2B035QXD BQ2B040QXD BQ2B045QXD BQ2B050QXD BQ2B060QXD

TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TC1Q1 TA1Q1 TA1Q1 TA1Q1 Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect Quick-Connect

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

Lugs-For Use with BQ, BQH, HBQ Circuit Breaker Amp. Rtg. Line Side 10–40 45–125 Load Side 10 15–20 25–35 40–50 55–70 80–100 110–125

Cab. Per Lug

Lug Wire Range AWG

1 1 1 1

#16–#6 Cu #12–#6 Al #8–#1 Cu #6–#1/0 Al

2 1 1 1 1 1 1 1 1 1 1 1 1

#16 Cu #14–#10 Cu #12–#10 Al #14–#6 Cu #12–#10 Al #8–#6 Cu #8–#4 Al #8–#4 Cu #8–#2 Al #4–#1/0 Cu #2–#1/0 Al #2–#1/0 Cu #1/0–#2/0 Al

Catalog Number TC1Q1 a b TA1Q1

n Built to order. Allow 2–3 weeks for delivery. Listed for use with 60/75° wire through 40 amps, UL listed for use with 75° wire only for 50 amps and above, HACR rated.

7-38

Protects against accidental contact with lugs–1 per lug. Fits line and load end. Catalog Number

Qty

BQFS2

2

BQFS1K

1000

Enclosures Connectors are Supplied with Circuit Breaker

For inches / millimeters conversion, see Application Data section. a UL

Finger Safe Terminal Shield

Type

Catalog Number d

1

EB3100S c

3R

WB3100

bConnector

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

Dimensions (inches) L

D1

D2

BQ, BQH BQ, BQH HBQ BQXD

33⁄4 4 4 41⁄2

23⁄8 23⁄8 23⁄8 23⁄8

3 3 3 3

15–50 55–125 15–125 15–60



has steel construction. mounted indoor. If flush mounting is required, replace suffix “S” in catalog number with suffix “F”. Neutral included in enclosure. Enclosure will not accept circuit breakers with shunt trips or auxiliary switches installed. cSurface

Breaker Type Amperes

 Type

BQXD uses TA1Q1 or TC1Q1 lugs on line side of circuit breaker.

Enclosures, see Section 6 For external accessories, please refer to pages 7-93, 7-95 to 7-100

Product Category MCCB

• Revised • 09/06/12

Molded Case Circuit Breakers QJ 225A Frame Continuous Current Rating @ 40°C

Type

Selection/Dimensions

QJ22B060n QJ22B070n QJ22B080n QJ22B090n QJ22B100 QJ22B110n QJ22B125 QJ22B150 QJ22B175 QJ22B200 QJ22B225

QJ23B060 QJ23B070 QJ23B080n QJ23B090n QJ23B100 QJ23B110 QJ23B125 QJ23B150 QJ23B175 QJ23B200 QJ23B225

QJH22B060n QJH22B070n QJH22B080n QJH22B090n QJH22B100n QJH22B110n QJH22B125 QJH22B150 QJH22B175n QJH22B200 QJH22B225

QJH23B060n QJH23B070n QJH23B080n QJH23B090n QJH23B100 QJH23B110 QJH23B125 QJH23B150 QJH23B175 QJH23B200 QJH23B225

QJ22B060Hn QJ22B070Hn QJ22B080Hn QJ22B090Hn QJ22B100Hn QJ22B110Hn QJ22B125H QJ22B150H QJ22B175Hn QJ22B200H QJ22B225H

QJ23B060Hn QJ23B070Hn QJ23B080Hn QJ23B090Hn QJ23B100H QJ23B110Hn QJ23B125H QJ23B150H QJ23B175H QJ23B200H QJ23B225H

— — — — — — —

HQJ23B100s HQJ23B110s HQJ23B125s HQJ23B150s HQJ23B175s HQJ23B200s HQJ23B225s

Ordering Information Load side TA1Q300 lugs are mounted and included when circuit breaker is ordered. For line and load lugs (TA1Q300) installed at no additional charge, add suffix “L” to catalog number.

QJ2b

060 070 080 090 100 110 125 150 175 200 225

50°C Calibration - See page 7-91. 400HZ. - See page 7-91.

Shipping Weights QJ2, QJH2, QJ2H, HQJ2

Type QJH2b 060 070 080 090 100 110 125 150 175 200 225

Number per Carton

Shipping Weight (lbs.)

2 3

10 10

30 41

Lugs For 75°C Wire a Catalog Number

Lug Body

Lug Wire Range

TA1Q300 Al

(1) #6—300 kcmil Cu (1) #4—300 kcmil Al

TC1Q250

(1) #6—250 kcmil Cu

Cu

Enclosures (Neutral Included)

Type QJ2Hb 060 070 080 090 100 110 125 150 175 200 225

Number of Poles

Type

Catalog Number

1 3R (2-pole) 3R (3-pole)

EB3225(S)(F) WB2225 WB3225

UL 489 Interrupting Ratings Breaker Type QJ2 QJH2 QJ2H HQJ2

RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 240

208Y/120

10 22 42 65

— — — 100

MOLDED CASE CIRCUIT BREAKERS

3-Pole 240V AC Catalog Number

7

2-Pole 240V AC Catalog Number

Type HQJ2b 7’’

3’’ 2-pole

QJ2

4.5’’ 3-pole

Internal Accessories (Factory installed only) (3-pole only)c Add suffix to catalog number. Auxiliary Switches Control Voltage

Shunt Trip

AC

DC

Suffix

24 48

00S01n 00S07n 00S09n

120/240

n Built to order. Allow 2–3 weeks for delivery. s Built to order. Allow 6–8 weeks for delivery. Note: A page 7-81. Note: QJ breakers are UL Listed for reverse feed applications.

a See

Product Category MCCB

2A and 2B

Shunt Trip and 1A and 1B Auxiliary Switch

Suffix

Suffix

Suffix

A01n A01n A01n

A02n A02n A02n

01S01n 01S07n 01S09n

1A and 1B

b HACR

rated. accessories are not available on 2-pole QJ breakers.

c Internal

2.5 D 3’’

100 110 125 150 175 200 225

Enclosures Section 6 For external accessories, please refer to pages 7-95 to 7-100

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

7-39

Molded Case Circuit Breakers CQD 100A Frame

Selection/Dimensions Shipping Weights

Type CQD (Cable In - Cable Out) DIN Rail Mountc Continuous Current Rating @ 40°C 115 120 125 130 135 140 145 150 160 170 180 190 100

1-Pole 277V AC 125V DC Catalog Number CQD115 ab CQD120 ab CQD125 b CQD130 b CQD135bn CQD140bn CQD145bn CQD150bn CQD160n CQD170n CQD180n CQD190n CQD1100n

2-Pole 480Y/277V AC 125/250V DC Catalog Number CQD215b CQD220b CQD225b CQD230b CQD235bn CQD240b CQD245bn CQD250b CQD260 CQD270 CQD280 CQD290n CQD2100

3-Pole

Number of Poles

Number per Carton

Shipping Weight lbs. (kg)

480Y/277V AC Catalog Number CQD315b CQD320b CQD325b CQD330b CQD335b CQD340b CQD345bn CQD350b CQD360 CQD370 CQD380 CQD390 CQD3100

1 2 3

1 1 1

0.5 (0) 1.0 (0) 1.5 (1)

Lugs For 60/75°C Wire Amps

Wire Size

15–40

#14–#6 AWG Cu #12–#6 AWG Al

45–100

#8–#1 AWG Cu #6–#1/0 AWG Al

Type CQD6 (Cable In - Cable Out) CSA Certified, not UL Continuous Current Rating @ 40°C 115 120 125 130 135 140 145 150 160 170

1-Pole 347V AC 125V DC Catalog Number — CQD6120 bn CQD6125 bn CQD6130 bn CQD6135n CQD6140n CQD6145n CQD6150n CQD6160n CQD6170n

2-Pole 600Y/347V AC 125/250V DC Catalog Number CQD6215n CQD6220n CQD6225n CQD6230n CQD6235n CQD6240n CQD6245n CQD6250n CQD6260n CQD6270n

3-Pole 600Y/347V AC Catalog Number CQD6315n CQD6320n CQD6325n CQD6330n CQD6335n CQD6340n CQD6345n CQD6350n CQD6360n —

CQD, CQD6

MOLDED CASE CIRCUIT BREAKERS

7

Interrupting Ratings

RMS Symmetrical Amperes (KA)

Breaker Type

Number of Poles

Volts AC (50/60 Hz)

CQD (UL) CQD6 (CSA)

Volts DC

120

240

277

480/277

600/347

125

125/250

1 2 3

65 — —

— 65 65

14 — —

— 14 14

— — —

14 — —

— 14 —

1 2 3

65 — —

— 65 65

14 — —

— — —

10 10 10

14 — —

— 14 —

CQD, CQD6

For inches / millimeters conversion, see Application Data section. n Built to order. Allow 2–3 weeks for delivery. a SWD

rated. Note: CQD breakers are UL Listed for reverse feed applications.

7-40

b HID

rated. rated.

c HACR

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

Enclosures Section 6 Accessories pages 7-42 and 7-95 to 7-100

Product Category MCCB

• Revised • 11/15/13

Molded Case Circuit Breakers GG 125A Frame

Selection/Dimensions

GG 125A Frame (Cable In - Cable Out) Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100

1-Pole

110 125

2-Pole

3-Pole

Catalog Number

Catalog Number

Catalog Number

NGG1B015La b NGG1B020La b NGG1B025Lb NGG1B030Lb NGG1B035Lb NGG1B040Lb NGG1B045Lb NGG1B050Lb NGG1B060L NGG1B070L NGG1B080L NGG1B090L NGG1B100L

NGG2B015Lb NGG2B020Lb NGG2B025Lb NGG2B030Lb NGG2B035Lb NGG2B040Lb NGG2B045Lb NGG2B050Lb NGG2B060L NGG2B070L NGG2B080L NGG2B090L NGG2B100L

NGG3B015Lb NGG3B020Lb NGG3B025Lb NGG3B030Lb NGG3B035Lb NGG3B040Lb NGG3B045Lb NGG3B050Lb NGG3B060L NGG3B070L NGG3B080L NGG3B090L NGG3B100L

NGG1B110L NGG1B125L

NGG2B110L NGG2B125L

NGG3B110L NGG3B125L

GG

2.9

5.4

Line and load lugs are included as standard. If no lugs are required, remove the “L” suffix. HACR rated. Suitable for screws or DIN rail mounting.

Type HGG (Cable In - Cable Out) Continuous Current Rating @ 40°C

Type LGG (Cable In - Cable Out)

2-Pole

3-Pole

Catalog Number

Catalog Number

Catalog Number

HGG1B015Lb HGG1B020Lb HGG1B025Lb HGG1B030Lb HGG1B035Lb HGG1B040Lb HGG1B045Lb HGG1B050Lb HGG1B060L HGG1B070L HGG1B080L HGG1B090L HGG1B100L HGG1B110L HGG1B125L

HGG2B015Lb HGG2B020Lb HGG2B025Lb HGG2B030Lb HGG2B035Lb HGG2B040Lb HGG2B045Lb HGG2B050Lb HGG2B060L HGG2B070L HGG2B080L HGG2B090L HGG2B100L HGG2B110L HGG2B125L

HGG3B015Lb HGG3B020Lb HGG3B025Lb HGG3B030Lb HGG3B035Lb HGG3B040Lb HGG3B045Lb HGG3B050Lb HGG3B060L HGG3B070L HGG3B080L HGG3B090L HGG3B100L HGG3B110L HGG3B125L

Shipping Weights

Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125

1-Pole

2-Pole

3-Pole

Catalog Number

Catalog Number

Catalog Number

LGG1B015Lb LGG1B020Lb LGG1B025Lb LGG1B030Lb LGG1B035Lb LGG1B040Lb LGG1B045Lb LGG1B050Lb LGG1B060L LGG1B070L LGG1B080L LGG1B090L LGG1B100L LGG1B110L LGG1B125L

LGG2B015Lb LGG2B020Lb LGG2B025Lb LGG2B030Lb LGG2B035Lb LGG2B040Lb LGG2B045Lb LGG2B050Lb LGG2B060L LGG2B070L LGG2B080L LGG2B090L LGG2B100L LGG2B110L LGG2B125L

LGG3B015Lb LGG3B020Lb LGG3B025Lb LGG3B030Lb LGG3B035Lb LGG3B040Lb LGG3B045Lb LGG3B050Lb LGG3B060L LGG3B070L LGG3B080L LGG3B090L LGG3B100L LGG3B110L LGG3B125L

Lugs For 60/75°C Wire

Number of Poles

Number per Carton

Shipping Weight lbs. (kg)

1 2 3

1 1 1

.75 (0.34) 1.3 (0.59) 2.0 (0.98)

NGG Ampere Rating

Wire Size

Catalog Number

15–30A

#14–#6 AWG Cu #12–#6 AWG Al

TC1Q1 (qty. 1) 3TC1Q1 (qty. 3)

35–125A

#8–1/0 AWG Cu #8–2/0 AWG Al

3TC1GG20 (qty. 3)

15–125A

Nut Keeper plate w/ screw (for crimp terminals)

TNKG3 (qty. 3)

Interrupting Ratings (max. RMS symmetrical amperes kA) Breaker Type NGG HGG LGG

Poles 1 2,3 1 2,3 1 2,3

UL489 Volts AC 120 65 — 65 — 65 —

240

277 — 65 — 65 — 65

347 25 — 35 — 65 —

480 14 — 14 — 14 —

­ — 25 — 35 — 65

600Y/347 — 14 — 14 — 14

Volts DC 125 14 — 14 — 14 —

For inches / millimeters conversion, see Application Data section. a SWD

rated.

Product Category MCCB

b HID

rated at 15-50A 1-pole @ 277 VAC; 2 & 3-pole @ 480 VAC

125/250 — 14 — 14 — 14

IEC 60947-2 (Ics = 50%Icu) Volts AC Volts DC 240 415 125/250 25 65 14 — — 14 — — 14

Enclosures Section 6 Accessories pages 7-42 and 7-95 to 7-100

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

7-41

MOLDED CASE CIRCUIT BREAKERS

1-Pole

7

15 20 25 30 35 40 45 50 60 70 80 90 100 110 125

GG

Molded Case Circuit Breakers Accessoriesa

• Revised • 08/02/13

Selection

Shunt Trip Control Voltage V AC 120 240 277 480 600

V DC — — — — —

— — — —

012 024 048 125

BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB and LGB Catalog Number CQDST120 CQDST240s CQDST277s CQDST480s CQDST600 CQDST12 CQDST24 CQDST48 CQDST125

Auxiliary Switch Maximum Voltage

BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB and LGB Catalog Number

AC

DC

Number of Contacts

240

125

1A–1B

CQDA1

240

125

2A–2B

CQDA2

CQD with Accessory Installed

Alarm Switch Maximum Voltage AC

DC

240

125

BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB and LGB Catalog Number CQDBA

MOLDED CASE CIRCUIT BREAKERS

7

Shunt Trip and Auxiliary Switch Combinations Shunt Trip Voltage AC 24 120 240 277 480 600 — — —

DC — — — — —



BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB and LGB Catalog Number

— 12 24

CQDST24AASs CQDST120AASs CQDST240AASs CQDST277AASs CQDST480AASs CQDST600AASs CQDST12DASs CQDST24DASs

48

CQDST48DASs

125

CQDST125DASs

Alarm and Auxiliary Switch Combinations For Breaker

Catalog Number

BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB and LGB

CQDA1BAs

s Built to order. Allow 6–8 weeks for delivery. aAdds

1-pole space for accessory.

7-42

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

Product Category MCCB

• Revised • 06/20/13

Molded Case Circuit Breakers EG 125A Frame

Selection/Dimensions

Type NEG (Cable In - Cable Out) Continuous Ampere Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125

1-Pole

2-Pole

3-Pole

4-Pole

Catalog Number

Catalog Number

Catalog Number

Catalog Number

NEG2B015Lb NEG2B020Lb NEG2B025Lb NEG2B030Lb NEG2B035Lb NEG2B040Lb NEG2B045Lb NEG2B050Lb NEG2B060L NEG2B070L NEG2B080L NEG2B090L NEG2B100L NEG2B110L NEG2B125L

NEG3B015L NEG3B020L NEG3B025L NEG3B030L NEG3B035L NEG3B040L NEG3B045L NEG3B050L NEG3B060L NEG3B070L NEG3B080L NEG3B090L NEG3B100L NEG3B110L NEG3B125L

NEG4B015L NEG4B020L NEG4B025L NEG4B030L NEG4B035L NEG4B040L NEG4B045L NEG4B050L NEG4B060L NEG4B070L NEG4B080L NEG4B090L NEG4B100L NEG4B110L NEG4B125L

NEG1B015La b NEG1B020La b NEG1B025Lb NEG1B030Lb NEG1B035Lb NEG1B040Lb NEG1B045Lb NEG1B050Lb NEG1B060L NEG1B070L NEG1B080L NEG1B090L NEG1B100L NEG1B110L NEG1B125L

HEG

Type HEG (Cable In - Cable Out) 1-Pole

2-Pole

3-Pole

4-Pole

Catalog Number

Catalog Number

Catalog Number

Catalog Number

HEG2B015Lb HEG2B020Lb HEG2B025Lb HEG2B030Lb HEG2B035Lb HEG2B040Lb HEG2B045Lb HEG2B050Lb HEG2B060L HEG2B070L HEG2B080L HEG2B090L HEG2B100L HEG2B110L HEG2B125L

HEG3B015L HEG3B020L HEG3B025L HEG3B030L HEG3B035L HEG3B040L HEG3B045L HEG3B050L HEG3B060L HEG3B070L HEG3B080L HEG3B090L HEG3B100L HEG3B110L HEG3B125L

HEG4B015L HEG4B020L HEG4B025L HEG4B030L HEG4B035L HEG4B040L HEG4B045L HEG4B050L HEG4B060L HEG4B070L HEG4B080L HEG4B090L HEG4B100L HEG4B110L HEG4B125L

HEG1B015La b HEG1B020La b HEG1B025Lb HEG1B030Lb HEG1B035Lb HEG1B040Lb HEG1B045Lb HEG1B050Lb HEG1B060L HEG1B070L HEG1B080L HEG1B090L HEG1B100L HEG1B110L HEG1B125L

3.0

5.5

NEG, HEG

7

Continuous Ampere Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125

Shipping Weights

MOLDED CASE CIRCUIT BREAKERS

Line and load lugs are included as standard. HACR rated. Suitable for screw mounting.

Lugs For 60/75°C Wire

Number of Poles

Number per Carton

Shipping Weight lbs. (kg)

1 2 3 4

1 1 1 1

1.1 2.0 3.1 3.9

NEG/HEG

(0.5) (0.9) (1.4) (1.8)

Ampere Rating

Wire Size

15–125A

#14 – 3/0 AWG Cu (steel lugs) 3TW1EG30 (qty. 3)

Catalog Number

15–125Ad

#14 – 1/0 AWG Cu #14 – 1/0 AWG Al

3TA1EG10 (qty. 3)

15–125Ad

#6 - 3/0 AWG Cu #6 - 3/0 AWG AI

3TA1EG30 (qty. 3)

15–125A

Nut Keeper plate w/ screw (for crimp terminals)

TNKE3 (3-Pole) TNKE4 (4-Pole)

Interrupting Ratings UL 489 AIR RMS Symmetrical Amperes (KA) Number Volts AC(50/60Hz) Volts DC Breaker of Type Poles 240 277 347 480 600/347 125 125/250 01 085 35 22 — — 35 — NEG — 35 2, 3, 4 085 — — 35 22c 01 0100 65 25 — — 42 — HEG — 42 2, 3, 4 0100 — — 65 25c

IEC 60947-2 Volts AC (50/60Hz) 220/240 380/415 lcu lcs lcu 85 43 — 85 43 40 100 50 — 100 50 70

lcs — 20 — 35

Volts DC 125 125/250 35 — — 35 42 — — 42

For inches / millimeters conversion, see Application Data section. a SWD b HID

rated. rated 277 VAC.

Product Category MCCB

c Applies

to 3 & 4-pole breakers only. lugs for NEG and HEG breakers.

d Optional

Accessories pages 7-44 and 7-95 to 7-100

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

7-43

Molded Case Circuit Breakers Internal Accessories for NEG and HEG 125A Frame

• Revised • 04/09/12

Selection

Shunt Trip

Control Voltage



V AC

V DC

NEG, HEG, NEB, HEB Catalog Number



110-240 — 380-600 24-60

— 125 — 24-60

STRER240A STRED125D STREV600 STREM60D

Auxiliary Switch Maximum Voltage AC

DC

Number of Contacts

240 240

125 125

1A–1B 2A–2B

NEG, HEG, NEB, HEB Catalog Number ASKE2 ASKE3

Alarm Switch Maximum Voltage AC

DC

Number of Contacts

240 240

125 125

1A–1B 2A–2B

NEG, HEG, NEB, HEB Catalog Number ASKE1 ASKE5

MOLDED CASE CIRCUIT BREAKERS

7

Undervoltage Trip

Control Voltage



AC



24



60

UVREM60s



120

UVREN120



240

UVRER240



480

UVREU480s



600

UVREV600s

DC

NEG, HEG, NEB, HEB Catalog Number UVREB24A

UVREB24D



24



48



125

UVRED125Ds



250

UVREE250Ds

UVREC48Ds

Alarm and Auxiliary Switch Combinations

For Breaker



NEG, HEG

Catalog Number ASKE6

s Built to order. Allow 6–8 weeks for delivery.

7-44

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

Product Category MCCB