Low-Voltage Enclosure Low-voltage enclosures may be either surface-mounted or flush-mounted in an electrical closet or equipment room. Both the number of enclosures and the types of components within them are customized to fit the size, lighting plan, and design of a home. Low-voltage enclosures can be distributed throughout the home near the rooms they are controlling, to provide maximum flexibility during installation of the low-voltage wiring. Low-voltage enclosures cannot house remote power modules (RPMs). 21-inch Low-Voltage Enclosure (Model # HQ-LV21-120) The twenty-one-inch low-voltage enclosure provides a compact housing for mounting up to two HomeWorks QS processors or up to two system interfaces and up to five wire landing boards (QS-WLB). The enclosure accepts one 120 V~ feed to power the panel, which is self-contained in an enclosed area, thus allowing access to only the low-voltage connections when the enclosure cover is removed.

Low-Voltage Enclosure (HQ-LV21-120)

Model Number HQ-LV21-120

Low-Voltage Enclosure

Low-Voltage Enclosure Cover (HQ-LV21-120)

www.lutron.com

Lutron® | 1

product specifications

369-381a

03.09.11

Low-Voltage Enclosure Specifications Model Number

HQ-LV21-120

Power

120 V~ Power Input 50 / 60 Hz 2 A

Regulatory Approvals

UL, CSA, NOM

Environment

Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C) Ambient operating humidity: 0-90% humidity, non-condensing. Indoor use only.

Mounting

Enclosure may be surface-mounted or recess-mounted. Enclosure fits between standard 16 in (41 cm) on-center stud framing. Mount the enclosure so that line-voltage wiring will be at least 6 feet (1.8 m) from audio or electronic equipment and wiring. Mount Enclosure using one of the following methods (mounting hardware is not pro­vid­ed): a. S  urface Mount – Use keyholes with bolts sufficient for 100 lb (45 kg) load, 1/4 in (M6) bolts rec­om­mend­ed. b. R  ecess Mount – Use screws sufficient for 100 lb (45 kg) through the corners of the enclosure. Mount enclosure fully into the stud bay, with the back flush against the inner wall surface. Enclosure is 4.088 in (104 mm) deep past cover mounting tabs (including pedestal). Enclosure cover dimensions are 21.5 in x 15.386 in (546 mm x 391 mm). NOTICE: This equipment is air-cooled. Mount in a location where the vented cover will not be blocked. 12 in (305 mm) of clearance in front of the vents is required. NOTICE: Power supply will hum slightly and internal relays will click while in use. Mount in a location where such noise is acceptable.

Dimensions

Enclosure: 21 in (533 mm) x 14.375 in (365 mm) x 4.088 in (104 mm) Cover: 21.5 in (546 mm) x 15.386 in (391 mm)

Construction

Enclosure: 16-gauge powder coated sheet metal. Cover: 16-gauge powder coated metal cover. Cover is attached using four philips-head screws.

Capacity

Enclosure can accomodate two processors or system interface devices and five wire landing boards (QS-WLB). Examples: 1 Processor and 1 System Interface or 2 Processors or 2 Interfaces

Line-Voltage Connections

Use copper wire only, supply conductors rated at 167 ºF (75 °C). Use supplied wire connections to connect to corresponding power supply harnesses.

Warranty

8 Year Limited Warranty. http://www.lutron.com/resiinfo

2 | Lutron®

24/7 Technical Support—800.523.9466

product specifications

03.09.11

369-381a

Low-Voltage Enclosure Dimensions and Mounting 14.375 (365) 13.285 (337)

Measurements shown as: in (mm)

7.750 (197)

Terminal Shield

Surface Mounting Pedestal (4x)

Line voltage wiring entry (non-IEC PELV / NEC® Class 2)

Power Supply DIN rail End Stop (5x)

Input Power Switch

-7°

+7° 18.0 (457)

21 (533)

0.312 (7.9)

20.0 (508)

0.430 (10.9) 0.624 (15.8)

11.5 (292)

www.lutron.com

PELV / Class 2 ONLY

Lutron® | 3

product specifications

369-381a

03.09.11

Low-Voltage Enclosure Configuration

L(+) N(-)

120 - 240 V Input / Entrada / Entrée

L(+) N(-)

24 V Output / Salida / Sortie

QSPS-DH-1-60

120 - 240 V Input / Entrada / Entrée

Power Supply QSPS-DH-1-60 (up to 2)

24 V Output / Salida / Sortie

QSPS-DH-1-60

22.5 - 25 V

22.5 - 25 V

HomeWorks QS Processor HQP6-2-120 (up to 2)

QS Wire Landing Board QS-WLB (up to 5, 1 included)

Power Draw Information Power Supply

Power Draw Units Supplied

QSPS-DH-1-60

75 PDU

Device

Power Draw Units Required (per device)

Processor HQP6-2-120

8 PDU

QSE-CI-NWK-E

2 PDU

QSE-IO

3 PDU

4 | Lutron®

24/7 Technical Support—800.523.9466