6 Series - Rutherford Controls

Report 3 Downloads 204 Views
6 Series

INSTALLATION

Electric Strikes

Instructions The L65 Low Profile version accepts 1/2” or 5/8” latch projection (perfect for narrow stile aluminum frames). The S65 Standard version is ideal when you require 3/4” latch projection. 1. Determine the vertical centerline of the door lock face and the horizontal centerline of the latch. IMPORTANT: When determining the horizontal centerline observe the following: FOR MORTISE LOCKS: Align the angled ramps of the lip bracket with the deadlock trigger of the mortise latch. FOR CYLINDRICAL LOCKS: Align the center of the latch with the center of the strike opening.**

4. If required, install the ‘no weld’ mounting brackets per page 4.

2. Transfer both the horizontal and vertical centerlines to the doorframe.**

7. Install the door strike in the doorframe using the screws provided.

5. Attach the strike faceplate to the lip bracket with the selftapping screws provided. (It may be desirable to leave these screws slightly loose to facilitate insertion into the doorframe. 6. Connect the incoming wiring from the power supply (see wiring instructions).

3. Prepare the doorframe for cutting as shown in the appropriate drawing.

A 1-1/4 1.250 31.75

X

.375

9.53

.125*

3.18*

D

Vertical Vertical Vertical

Vertical Centerline C/L C/L of Door**



Door

R 5/32

Door

M 12-24

B

K

M

F

CL



C

Door



R

E

E 3/8

.375

9.53

F

.125*

3.18*

1/8*

Vertical Vertical Vertical

Vertical Centerline C/L C/L of Door**

X C/L

Door

R 5/32 A

D

G 1-11/16 1.688 42.86

G

G

0.156 3.97

K 4-1/8 4.125 104.78

M

D 1-3/32 1.094 27.78

G 1-11/16 1.688 42.86 X C/L

METRIC mm

C 3-3/8 3.375 85.73

R

E

D 1-3/16 1.188 30.16 1/8*

X

B 4-7/8 4.875 123.83

C 3-3/8 3.375 85.73

F

CL

A 1-1/4 1.250 31.75

M

B 4-7/8 4.875 123.83

E 3/8

DECIMAL INCHES

MEASUREMENT

METRIC mm

DECIMAL INCHES

FRACTIONAL INCHES

MEASUREMENT

CL

FRACTIONAL INCHES

L6504 Aluminum Frames, 1-1/16” Insert Depth Modular AL65 with B604 faceplate

S6504 Aluminum Frames, 1-3/16” Insert Depth Modular AS65 with B604 faceplate

Door

B

K

CL

G C G

Door

0.156 3.97

K 4-1/8 4.125 104.78 M 12-24

M

F



A



NOTE: Specifications subject to change without notice. * Dimension F is measured from face of mounting tab to face of frame. ** Dimension X on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be necessary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness to Dimension X to relocate the vertical centerline an appropriate distance on the frame.

IS6A

       © 2014 Rutherford Controls Int’l | A DORMA Group Company www.rutherfordcontrols.com • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]

PCN14014 R06/14TG

6 Series Installation Instructions (Continued)

X

A 1-1/8 1.125 28.58

M

R

B 5-7/8 5.875 149.23

E

1/4

0.250 6.35

F

1/8*

.125*

3.18*

Vertical Vertical Vertical Vertical Centerline X Door Door Door

of Door**

R 5/32

.156

G

K

G

METRIC mm

DECIMAL INCHES

FRACTIONAL INCHES

1/4

0.250 6.35

F

1/8*

.125*

X

Vertical Centerline C/L C/L C/L of Door** .156

G

K

C

B G

Door Door Door

R 5/32

M

3.97

K 5-3/8 5.375 136.53

A

M 12-24† — —

D

3.18*

Vertical Vertical Vertical

M

K 5-3/8 5.375 136.53

E

G 1-11/16 1.688 42.86 C

B

3.97

E

D 1-3/32 1.094 27.78

D

M

R

C 3-3/8 3.375 85.73

E

G 1-11/16 1.688 42.86

X

A 1-1/8 1.125 28.58 B 5-7/8 5.875 149.23

C 3-3/8 3.375 85.73 D 1-3/16 1.188 30.16

L6505 Aluminum & Wood Frames, 1-1/16” Insert Depth Modular AL65 with B605 faceplate MEASUREMENT

METRIC mm

DECIMAL INCHES

FRACTIONAL INCHES

MEASUREMENT

S6505 Aluminum & Wood Frames, 1-3/16” Insert Depth Modular AS65 with B605 faceplate

A

M 12-24 — —

X

A 1-1/4 1.250 31.75 B 6-7/8 6.875 174.63 C 3-3/8 3.375 85.73 D 1-3/16 1.188 30.16 E 3/8 0.375 9.53 F

1/8*

.125*

M R

E

3.18*

VerticalC/L Centerline C/L of Door**

B K

Door Door Door

R 5/32

.156

C G

M

M 12-24† — —

METRIC mm

E D

3.18*

VerticalC/L Centerline C/L of Door**

CL B K

Door Door Door .156

G C

F

X C/L

R 5/32 A

.125*

Vertical Vertical Vertical

3.97

K 6-1/8 6.125 155.58

1/8*

M R

G 1-11/16 1.688 42.86

G

F

X C/L

X

F CL

CL

A 1-1/4 1.250 31.75 B 6-7/8 6.875 174.63 C 3-3/8 3.375 85.73 D 1-3/32 1.094 27.78 E 3/8 0.375 9.53

D

G 1-11/16 1.688 42.86 Vertical Vertical Vertical

DECIMAL INCHES

CL

FRACTIONAL INCHES

MEASUREMENT

METRIC mm

DECIMAL INCHES

L6507 Aluminum & Wood Frames, 1-1/16” Insert Depth Modular AL65 with B607 faceplate

FRACTIONAL INCHES

S6507 Aluminum & Wood Frames, 1-3/16” Insert Depth Modular AS65 with B607 faceplate MEASUREMENT



G

M

3.97

K 6-1/8 6.125 155.58 M 12-24† — —

A

NOTE: Specifications subject to change without notice. * Dimension F is measured from face of mounting tab to face of frame. ** Dimension X on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be necessary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness to Dimension X to relocate the vertical centerline an appropriate distance on the frame. † For wood frame door installations, substitute #12 wood screws for dimension M.

2

       © 2014 Rutherford Controls Int’l | A DORMA Group Company www.rutherfordcontrols.com • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]

X

A 1-7/16 1.438 36.51

M

R

C 3-3/8 3.375 85.73

.125*

3.18*

Vertical Vertical Vertical

Vertical Centerline C/L C/L of Door**

G

K

C

B G

X C/L

Door Door Door

R 5/32

.156

A

MEASUREMENT

DECIMAL INCHES

FRACTIONAL INCHES

MEASUREMENT

METRIC mm

E

G 1-11/16 1.688 42.86 X

Vertical Centerline C/L C/L C/L of Door**

M 12-24





DECIMAL INCHES

METRIC mm

G

Door Door Door .156

M

3.97

A

CL M

X

B

K

C 3-3/8 3.375 85.73

M F

E

D 1-3/32 1.094 27.78

D

CL

G C G

E

3/8

.375

9.53

F

1/8*

.125*

3.18*

G 1-11/16 1.688 42.86 Vertical Vertical Vertical X

Door Door Door

K 4-1/8 4.125 104.78

Vertical Centerline C/L C/L of Door**

C

B

B 4-7/8 4.875 123.83

D 1-3/16 1.188 30.16

Vertical Vertical Vertical

Vertical Vertical Vertical

G

K

A 1-1/4 1.250 31.75

C 3-3/8 3.375 85.73

3.18*

3.18*

L6514 Hollow Metal Frames, 1-1/16” Insert Depth Modular AL65 with B614 faceplate

B 4-7/8 4.875 123.83

.125*

.125*

M

X

A 1-1/4 1.250 31.75

1/8*

1/8*

G 1-11/16 1.688 42.86

M 12-24† — —

CL

F

F

D

K 7-7/16 7.438 188.91

S6514 Hollow Metal Frames, 1-3/16” Insert Depth Modular AS65 with B614 faceplate

9.53

0.250 6.35

R 5/32

M 12-24† — —

.375

1/4



K 7-7/16 7.438 188.91

3/8

E

X C/L

M

3.97

E

M

METRIC mm

1/8*

G 1-11/16 1.688 42.86

E

DECIMAL INCHES

F

R

D 1-3/32 1.094 27.78

D

FRACTIONAL INCHES

0.250 6.35

A 1-7/16 1.438 36.51 C 3-3/8 3.375 85.73

E

D 1-3/16 1.188 30.16 1/4

X

B 7-15/16 7.938 201.61

B 7-15/16 7.938 201.61

E

FRACTIONAL INCHES

MEASUREMENT

METRIC mm

DECIMAL INCHES

L6508 Aluminum & Wood Frames, 1-1/16” Insert Depth Modular AL65 with B608 faceplate

FRACTIONAL INCHES

S6508 Aluminum & Wood Frames, 1-3/16” Insert Depth Modular AS65 with B608 faceplate MEASUREMENT

6 Series Installation Instructions (Continued)

A

Vertical Centerline C/L C/L C/L of Door**

B

D

K

M F

CL

G C G

Door Door Door

K 4-1/8 4.125 104.78 M 12-24





A

NOTE: Specifications subject to change without notice. * Dimension F is measured from face of mounting tab to face of frame. ** Dimension X on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be necessary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness to Dimension X to relocate the vertical centerline an appropriate distance on the frame. † For wood frame door installations, substitute #12 wood screws for dimension M.

      © 2014 Rutherford Controls Int’l | A DORMA Group Company www.rutherfordcontrols.com • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]

3

6 Series Installation Instructions (Continued)

Mounting Tab Kit Instructions Mounting Tab (2 incl.)

Mounting tab kit is for use with aluminum and steel frames that do not have factory installed mounting tabs for electric strike installation. 1. Prepare the frame as shown in the approximate drawing. Fasten the mounting tab to the faceplate of the strike, selecting the appropriate shims for the installation.

Self-Adhesive Mounting Shim (8 incl.)

12-24 Machine Screws (2 per tab)

2. Using the assembled strike and tabs as a template, place against the frame and mark the mounting hole locations. Remove and drill a 3/16” hole in frame for each mounting tab and countersink the frame. 3. Remove the tabs from the faceplate and install in the frame using the 12-24 x 3/8” machine screws supplied. Tabs are zinc plated and drilled and tapped for this purpose. 4. Make final electrical connections per wiring instructions and mount strike to the tabs with the 12-24 x 3/8” machine screws.

Frame

Trim Plate Instructions 1. Position the Trim Plate on the frame cut-out to verify fit and coverage. 2. Adjust cut-out if required. 3. Bend the four tabs to hold the Trim Plate onto the frame. 4. For a tighter fit, pre-bend the two long flange tabs before sliding onto the frame where space allows. 5. Secure the strike to the frame as per strike installation instructions.

4

    © 2014 Rutherford Controls Int’l | A DORMA Group Company www.rutherfordcontrols.com • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]

6 Series Installation Instructions (Continued) Wiring Instructions

Fail Unlocked Rotate the adjustment screw so the dimple is fully rotated to opposite the faceplate side of the strike (fully counter clockwise). Your strike is now fail unlocked and requires power to lock. See Fig. 1.

NOTE: Overheated or Burnt Coils caused by incorrect input voltage / wire harness combinations will not be covered under warranty. Use 12VDC wire harness for 12VDC or 12-24VAC input power. Use 24VDC wire harness for 24VDC input power only. Attach the red wire to (+) positive of the power supply. Attach the black wire to the (–) negative of the power supply (see Fig. 4). If using AC power, polarity is not observed.

Fig. 1 Fail Unlocked = screw fully counter clockwise

NOTE: If a suppression diode is required for access control, observe proper polarity.

Fail Locked Rotate the adjustment screw so the dimple is fully rotated to the faceplate side of the strike (fully clockwise). Your strike is now fail locked and requires power to unlock the door. See Fig 2.

24VDC Terminal 12VDC 12-24VAC Terminal

Red Black +–

Red Black +–

Fig. 2

Fail Locked = screw fully clockwise

Optional LMKM

N NC O C

Lip Bracket Adjustment If your door or latch is out of adjustment, the insert can be adjusted forward or back as required for proper alignment to the latch. See Fig. 3 1. Remove the strike from the frame. 2. Remove the faceplate from the strike. 3. 2 screws secure the lip bracket to the main insert. 4. Loosen these screws approximately 1-1/2 to 2 full turns to allow the insert to move forward or backward as required. 5. Once the adjustment is made tighten all screws and reinstall the strike in the frame. Lip Bracket Screw

Faceplate Removed

Latch Monitor

Adjustment Direction

Keeper Monitor

C N NO C

Fig. 4 Wiring the 6 Series electric strike

Latch Monitor Wires Black

= Common (C)

Blue

= Normally Close (NC)

Orange = Normally Open (NO)

Keeper Monitor Wires Black

= Common (C)

Yellow = Normally Closed (NC) Green

= Normally Open (NO)

When using LMKM option: If the lockset on the door has a 1/2” or 5/8” latch projection, The L65 model is appropriate.

Keeper

If the lockset on the door has a 3/4” latch projection, you must use the S65 model. Lip Bracket

Strike Insert

NOTE: Contacts are indicated with the keeper in a closed and locked condition, with no latch present.

Fig. 3 Lip bracket adjustment   © 2014 Rutherford Controls Int’l | A DORMA Group Company www.rutherfordcontrols.com • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]

5

6 Series Troubleshooting Problem 1. Strike will not lock or

Possible Causes

Solution

No power to the insert

Using a multimeter, confirm that you have the correct output voltage at the power supply.

unlock properly

Using a multimeter, confirm that you have the correct input voltage at the strike. Confirm that all connections are tight and secure. Incorrect voltage used

Confirm that the insert and power supply are the proper voltage.

Strike is binding

Confirm that the strike keeper functions when the door is open. If the strike operates correctly, adjust door or strike to eliminate any backpressure. Confirm that the strike cavity depth is compatible with the lock set.

2. Strike releases but

Improper power supply

Replace the power supply with a correct voltage AC power supply, and the 12V connector. If this cannot be done, a DC piezo buzzer can be installed.

3. Strike makes a buzzing

Improper power supply

Replace the power supply with a correct voltage DC power supply.

Improper application

A strike connected to an AC power supply will buzz unless a rectifier is installed.

Improper voltage

Confirm that you have the correct output voltage at the power supply.

Improper installation

Confirm that the correct connector was used when installing the strike 12V for 12VDC & 12-24VAC, 24V for 24VDC only.

won’t buzz

sound

4. Insert has a burnt smell

Confirm that all connections are tight and secure.

5. Mortise lock not dead latching

Improper Installation

Check alignment of dead latch and lip bracket ramp.

Door has sagged

Adjust door alignment.

6.

Cylindrical deadlatching not working

Improper Installation / Door has warped

Adjust the strike horizontal adjustment. (See Installation Instructions).

7.

Door won’t latch

Door has warped or sagged creating excessive back pressure

Re-align door in frame or replace.

8.

Monitor switch is not functioning

Short in wiring

Confirm that all connections are tight and secure. Using a multimeter confirm continuity of the N/O & N/C sides of the switch.

Latch or keeper are not functioning properly

6

Confirm that the keeper is closing properly and that the lever in the strike cavity is operating freely.

    © 2014 Rutherford Controls Int’l | A DORMA Group Company www.rutherfordcontrols.com • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: [email protected]