6500 Series Installation Instructions - Dynalock

Report 8 Downloads 278 Views
SERIES #6500 - DOUBLE GANG HIGH VISIBILITY PUSH PLATE

DynaLock

705 Emmett Street Bristol, CT 06010 Phone:(860)582-4761 Fax:(860)585-0338

INSTALLATION INSTRUCTIONS

OVERVIEW

The 6500 Series Pushplate mounts to a standard 2-gang electrical box. Illuminated display uses electroluminescent blue lamp which requires high voltage AC. An inverter is included to convert regulated 12 or 24 VDC (as specified) to the necessary AC voltage. The inverter must remain inside the box to which the pushplate is being mounted. Pushplate activates the switch when completely depressed. Sensitivity can be adjusted by altering the depth of the switch.

CAUTION! INVERTER PRODUCES HIGH VOLTAGE AC. READ ALL INSTRUCTIONS PRIOR TO INSTALLATION.

INSTALLATION STEPS 1. 2. 3. 4. 5.

Connect gray leads coming from the lamp to the white leads on inverter cube. Polarity not observed. Connect low voltage DC to red and black leads on inverter cube (see reverse). Connect switch wiring. See reverse for schematic according to style ordered. Make sure all wiring is clear of the four shoulder bolts. Mounting screws are accessed through the four holes on the front face of the pushplate. Using included Allen wrench, start threads on each screw. 6. Tighten mounting screws evenly by alternating each corner, until the faceplate is flush with the wall. EL LAMP LEADS 4-9/16”

13/16”

13/16”

1-1/8”

1”

4-1/2”

DynaLock MOUNTING SCREW ACCESS HOLE

PTD SWITCH FACEPLATE

SHOULDER BOLT MO1, MO2, AA1, AA2 SWITCH

MISCELLANEOUS Lamp Life: Indefinite. Optimal brightness - first 10,000 hours, continuous use. Field replacements available. Temperature Range: 15 to 120°F - Interior use only. 6500 MANUAL - FORM 6500-002

Page 1

10/06

SERIES #6500 - DOUBLE GANG HIGH VISIBILITY PUSH PLATE

DynaLock

705 Emmett Street Bristol, CT 06010 Phone:(860)582-4761 Fax:(860)585-0338

INSTALLATION INSTRUCTIONS

INVERTER WIRING WHITE WHITE AC OUT: WIRE TO GRAY LAMP LEADS (polarity not observed) Voltage: 220 VAC Frequency: 650 Hz

RED (+) BLACK (-)

• SWITCH DC VOLTAGE TO TURN LAMP ON AND OFF (NEVER SWITCH LAMP ON AC SIDE). • DO NOT APPLY POWER WITHOUT LAMP CONNECTED. • USE REGULATED DC POWER SUPPLY OR PLUG-IN ONLY.

5/8” 7/8”

DC IN: WIRE TO DC VOLTAGE (12 or 24VDC as specified) Current Draw: 30mA @ 12 or 24 VDC

1”

SWITCH WIRING SWITCH STYLE: MO1

SWITCH STYLE: AA1 BLACK

WHITE (NC) (C) (NO)

GREEN

SWITCH STYLE: PTD

(NC) (C)

RED

(NO)

YELLOW GRAY

YELLOW RED

YELLOW RED

SPDT MOMENTARY CONTACTS RATED 6 AMPS @ 125VAC

SPDT ALTERNATE-ACTION CONTACTS RATED 6 AMPS @ 125VAC

MOMENTARY TIME DELAYED CONTACTS RATED 10 AMPS @ 12OVAC PTD / FORM Z

SWITCH STYLE: MO2

SWITCH STYLE: AA2

TIME DELAY ADJUSTMENT

BLACK

WHITE (NC) (C) (NO) (NC) (C) (NO)

GREEN

(NC) (C)

RED

WHITE GREEN

(NO) (NC) (C) (NO)

6500 MANUAL - FORM 6500-002

BOTTOM VIEW

GRAY

YELLOW

TURN CW TO INCREASE TURN CCW TO DECREASE

GRAY

TIME DELAY ADJUSTMENT RANGE = 2 - 60 SECONDS

BLACK

RED

DPDT MOMENTARY CONTACTS RATED 6 AMPS @ 125VAC

YELLOW

TIME DELAY ADJUSTMENT KNOB

DPDT ALTERNATE-ACTION CONTACTS RATED 6 AMPS @ 125VAC Page 2

10/06