Accucore HPLC Columns for Biomolecule ... - Thermo Fisher Scientific

Report 1 Downloads 100 Views
Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

Ultimate Core Performance

to Maximize Your Investment

Core Enhanced Technology – for Biomolecules The range of Accucore™ HPLC columns packed with 150 Å pore diameter particles allow biomolecule separations to benefit from the superb resolution and high speed enabled by the Core Enhanced Technology™ that Accucore is based on.

The key components of Core Enhanced Technology are: Solid Core Particles

Tight Control of Particle Diameter

2.6 µm diameter particles with a solid core generate high speed, high resolution separations without excessive backpressure

Enhanced selection process keeps particle size distribution to a minimum and produces high efficiency columns

Automated Packing Process

Advanced Bonding Technology

Enhanced automated procedures ensure that all columns are packed with the highest quality

Optimized phase bonding creates a series of high coverage, robust phases

Fast Separations High Peak Capacity Increased Sensitivity Lower Pressure Good Loading Capacity Reproducible Chromatography Long Lifetime Peptide and Protein Analysis

150 Å Solid Core Particles

Tight Control of Particle Diameter

Advanced Bonding Technology

Automated Packing Process

• • • •

• • • • • • •

• • •

• • • • • • •

• •

• • • •

The table above shows how the components of Core Enhanced Technology with 150 Å pore diameter particles contribute to the outstanding features of Accucore HPLC columns for biomolecule separations.

Table of Contents Why Core Enhanced Technology Works

2

150 Å Pore Diameter Particles

3

Column Formats

4

Analytical and Micro Columns. . . . . . . . . . . . . . . . . . . . 4 Defender Guard Cartridges . . . . . . . . . . . . . . . . . . . . . 4 nanoViper Columns . . . . . . . . . . . . . . . . . . . . . . . . . 4 Biomolecule Phases 5 Accucore 150-C18 Column

6

Peptide Separations

6

High Peak Capacity . . . . . . . . . . . . . . . . . . . . . . . . . 7 Reproducible Separations . . . . . . . . . . . . . . . . . . . . . . 7 Excellent Loading Capacity . . . . . . . . . . . . . . . . . . . . . 8 9 Accucore 150-C4 Column Protein Separation

9

Excellent Resolution . . . . . . . . . . . . . . . . . . . . . . . . 10 Reproducible Results . . . . . . . . . . . . . . . . . . . . . . . 10 Proven Loading Capacity. . . . . . . . . . . . . . . . . . . . . . 11 Thermo Scientific nanoViper Column Separations 12 Ordering Information Accucore HPLC Columns. . . . . . . . . . . . . . . . . . . . . . 13 Accucore Defender Guard Cartridges . . . . . . . . . . . . . . . 13

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

1

Why Core Enhanced Technology Works Two factors that strongly affect chromatographic efficiency are mass transfer and eddy diffusion, the C and A terms respectively from the Van Deemter equation.

H=A+

B + Cu u

H Height equivalent to theoretical plate (column length/efficiency)

A B C u

Eddy diffusion Longitudinal diffusion Resistance to mass transfer

Resistance to mass transfer is minimized by the solid core design of Accucore particles as the diffusional path of analytes is limited by the depth of the outer porous layer.

Mobile phase linear velocity

Material

Accucore 2 6 μm

Particle Size Distribution (D90/10)

1 15

The tight control of particle diameter and automated packing process used for Accucore columns result in a tight, highly uniform packed bed that minimizes eddy diffusion.

Lower Backpressure L h F dp2 dc2

Column length (cm) Mobile phase viscosity (cP) Flow rate (mL/min) Particle diameter (μm)

DP ~

250LhF dp2dc2

Column diameter (cm)

The equation above shows how backpressure is related to particle diameter. The tightly controlled 2.6 µm diameter of Accucore particles also results in lower backpressures than typically seen with sub-2 µm materials.

2

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

150 Å Pore Diameter Particles The 150 Å pore diameter solid core particles used in the Accucore 150-C18 and 150-C4 columns are designed specifically to provide the optimum combination of retention and resolution for peptides and proteins. The chromatograms below show the improved resolution and peak shapes achieved with Accucore 150-C18 compared to a C18 solid core phase with an 80 Å pore diameter.

Accucore 150-C18

1.12

3.76

7.09

8.74

13.46

8.91 11.20

Conventional Solid Core C18

1.01 8.52 6.98

3.60

13.13 10.84

Improved resolution Improved peak shape

Peak Capacity

150

Peak Capacity Comparison

140 130 120 110 100 90

Sharper peaks result in a significantly higher peak capacity for 150-C18 compared to the conventional solid core C18 column.

80 70 60 Accucore 150-C18

Conventional Solid Core C18

Stationary Phase

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

3

Column Formats Accucore HPLC columns for biomolecules are offered in both analytical, micro and nano formats. Optimum conditions and backpressure ratings are shown in the table below.

Format

Column ID

Optimum Flow Rate

Optimum Backpressure Injection Volume Rating

Temperature Rating

Nano

75 μm

300 nL/min

1 μL

800 bar

70 °C

Micro

2.1 mm

400 μL/min

1 μL

1000 bar

70 °C

Analytical

3.0 mm

800 μL/min

3 μL

1000 bar

70 °C

Analytical

4.6 mm

1800 μL/min

5 μL

1000 bar

70 °C

Analytical and Micro Columns Accucore HPLC columns are packed into our high pressure hardware. These stainless steel columns are engineered to the highest quality and have a pressure rating of 1000 bar.

Thermo Scientific Defender Guard Cartridges Guard columns are designed to protect your column from particulates introduced from the matrix or instrument and from any strongly retained components in the injected sample. Defender™ Guard Cartridges have been designed specifically to work with high speed, high efficiency separations.

nanoViper Columns The nanoViper fingertight connection system for nanoLC connections eliminates the assembly of PEEK sleeve connections. It is preassembled and fingertight to maximize ease-of-use. The nanoViper fitting is capable of withstanding pressures up to a 1000 bar and is compatible with third party valves and unions. Accucore nanoViper columns are available in 150 and 500 mm lengths – for ultra-high peak capacity.

4

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

Biomolecule Phases Like all other Accucore products, the 150 Å pore size particles and the phases based on them are fully characterized using the suite of tests shown below.

Silica Support Properties

Bonded Phase Properties

Hydrophobic Interactions

Secondary Interactions

Acidic Interactions

Surface Area

Carbon load

Hydrophobic retention

Base activity

Acid interaction

HR

BA

Hydrophobic selectivity

Pore Size

Particle Size

Steric selectivity

C

IEX(2.7)

Ion exchange capacity (pH 7.6)

SS Particle Size Distribution

Ion exchange capacity (pH 2.7)

Chelation

HS

AI

IEX(7.6)

Hydrogen bonding capacity

HBC

Details, including the phase characterization, are given below for the Accucore biomolecule phases. HR/10 AI

HS

IEX (2.7)

SS

C

HBC

Phase characteristics are designed for the separation of peptides

IEX (7.6)

BA

Accucore 150-C18

HR/10 AI

HS

IEX (2.7)

SS

Accucore 150-C4 C

HBC

BA

IEX (7.6)

Lower hydrophobic retention, optimal retention of proteins and larger peptides

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

5

Accucore 150-C18 HR/10

Hydrophobicity

AI

Low

HS

pH Range 0

1 to 11

14

IEX (2.7)

Pore Size 0

150 Å

SS

300

Carbon Load (%)

C 0

7

HBC

25

Particle Size 2.6 µm

USP L1

BA



Designed for the separation of peptides



Outstanding resolution

IEX (7.6)

Peptide Separations Accucore 150-C18

240000 220000 200000 180000 160000

mAU

140000 1

120000 100000 80000

2

60000

4

3

Mobile phase A: 0.1 % TFA in 10:90 acetonitrile:water

7

5

Mobile phase B: 0.1 % TFA in 70:30 acetonitrile:water

6

40000

Gradient:

0-50 % B over 15 min; hold for 2 min; drop to 0 % in 0.1 min; hold at 0 % B for 5 min

Flow:

300 µL/min

Temperature:

35 °C

Column:

Accucore 150-C18 2.6 µm, 100 x 2.1 mm

Injection:

5 µL

Detection:

UV (220 nm)

20000 0 -20000 -40000 0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Time (min)

Peak Number

6

15

tR/min

Peptide

MW

1

1.12

Glycine-Tyrosine

238.24 Da

2.0

2

3.76

Valine-Tyrosine-Valine

379.45 Da

17.0

3

7.09

Met-Enkephalin

573.66 Da

21.0

4

8.74

Angiotensin III

931.09 Da

15.0

5

8.91

Leu-Enkephalin

569.65 Da

21.0

6

11.20

Ribonuclease A

~ 13700 Da

42.5

7

13.46

Insulin

5733.49 Da

30.0

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

Concentration (µg/mL)

High Peak Capacity Higher peak capacities facilitate increased peptide identifications. Accucore 150-C18 provides much narrower peak widths, therefore significantly higher peak capacity than a column packed with < 2 µm wide pore fully porous C18. Accucore 150-C18 Backpressure: 175 bar

146

Peak Capacity

Conventional Solid Core C18 Backpressure: 170 bar

Peak Capacity Comparison

144 142 140 138 136 134 132 Accucore 150-C18

< 2 µm Wide Pore Fully Porous C18

Stationary Phase

< 2 µm Wide Pore Fully Porous C18 Backpressure: 320 bar

uAU

100000

nc = 1 +

50000 0 -50000 2

4

6

8

10

12

14

Time (min)

tg

(w )

nc Peak capacity tg Gradient time w Average peak width 10% height

Reproducible Separations Precision of retention times is critical for reliable analysis. The Accucore 150-C18 column exhibits excellent retention time reproducibility.

13.0

Peak Number 7

13.5

14.0

Peptide

tR (min)

% RSD

Insulin

13.58

0.11

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

7

Excellent Loading Capacity The data below demonstrates the impact on peak capacity of increasing the load of peptides on the Accucore 150-C18 column. Only for loads exceeding 2 µg on the column are significant decreases in peak capacity observed. 2200 2000 1800 1600

mAU

1400 1200 1000

13.1 µg

800

6.7 µg

600

3.4 µg

400

1.7 µg

200

0.8 µg

0 -200 0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

Time (min)

Loading Capacity

200

Peak Capacity

150

100

50

0 0

2

4

6

8

10

Total Load on Column /µg

8

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

12

14

Total Load on Column (µg)

Peak Capacity

0.8

159.24

1.7

152.75

3.4

142.31

6.7

128.87

13.1

107.76

15

Accucore 150-C4 HR/10

Hydrophobicity

AI

Low

HS

pH Range 0

2 to 9

14

IEX (2.7)

Pore Size 0

150 Å

SS

300

Carbon Load (%)

C 0

2

HBC

25

Particle Size 2.6 µm

USP L26

BA



Significantly lower hydrophobic retention than C18



Ideal for retention of proteins and larger peptides

IEX (7.6)

Intact Protein Separation 130000 120000 110000

5

100000 90000 3

80000

mAU

70000

Mobile phase A: 0.1 % TFA in 30:70 acetonitrile:water Mobile phase B: 0.1 % TFA in 98:2 acetonitrile:water

60000 2

50000

6

Gradient:

0-30 % B over 8 mins 30-95 % B over 2 mins 95 % B hold for 1 min 0 % B hold for 4 mins

Flow:

400 µL/min

Temperature:

40 °C

Column:

Accucore 150-C4 2.6 µm, 100 x 2.1 mm

Injection:

2 µL 10 pmol/µL solution

Detection:

UV (214 and 280 nm)

40000 1

30000

*

20000 10000

4

0 -10000 0

1

2

3

4

5

6

7

8

9

10

Time (min) Peak Number

tR/min

Protein

MW

Concentration (µg/mL)

1

1.54

Insulin

6 kDa

40

2

2.66

Cytochrome C

12 kDa

80

3

4.42

Lysozyme

14 kDa

100 120

4

7.38

Myoglobin

18 kDa

5

7.88

Carbonic anhydrase

30 kDa

200

6

7.88

Ovalbumin

45 kDa

300

*

Carbonic anhydrase impurity

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations | Technical Guide

9

Excellent Resolution Accucore 150-C4 provides significantly sharper and higher peaks than a column packed with 5 µm wide pore fully porous C4 – thus offering better resolution and sensitivity. The Accucore 150-C4 also performs better than a column packed with < 2 µm wide pore fully porous C4 and generates only a fraction of the backpressure.

uAU

Accucore 150-C4

Accucore 150-C4 Backpressure: 185 bar

100000

100000

80000

80000

60000

60000

*

40000

20000

0

0 0

2

4

*

40000

20000

6

8

0

10

2

uAU

5 µm wide pore fully porous C4 80000

80000

60000

60000

40000

40000

20000

20000

0

0 0

2

4

6

8

6

8

*

2

4

6

8

Time (min)

Time (min)

Reproducible Results The Accucore 150-C4 column exhibits excellent peak shape and retention time reproducibility.

Protein

9.2

9.4

Time (min)

10

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

Ovalbumin (45 kDa)

Mean tR / min % RSD 9.30

Data From Six Injections

10

< 2 µm wide pore fully porous C4 Backpressure: 320 bar

0

10

4

0.06

Mean peak width at half height / min

Mean asymmetry

0.05

1.14

10

Proven Loading Capacity As the load on the Accucore 150-C4 column increases up to 1200 pmoles (25 µg) peak shapes remain very sharp as shown by the peak capacity plot.

Loading Capacity 140

120

100

Peak Capacity

1200 pmoles 600000 600 pmoles

mAU

500000 400000

300 pmoles

300000

120 pmoles

200000

80

60

40

60 pmoles

20

100000 30 pmoles 0

0

0

1

2

3

4

5

Time (min)

6

7

8

9

10

0

200

400

600

800

1000

1200

Total Load on Column (total pmoles)

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

11

nanoViper Column Separations Protein separation using formic acid as an MS compatible mobile phase additive 20 4

15

5 2

Mobile phase A: 0.1 % formic acid in water Mobile phase B: 0.1 % formic acid in acetonitrile

mAU

1 10

Gradient:

3

0-30 % B over 1 min 30-60 % B over 10 mins 60-95 % B over 1 min 95 % B hold for 3 mins

5

* 0

7

6

8

9

10

11

12

13

Flow:

300 nL/min

Temperature:

40 °C

Column:

Accucore 150-C4, 2.6 µm, 150 x 75 µm

Backpressure:

204 bar (100 % A)

Injection:

0.25 µL 2 pmol/µL solution

Detection:

UV (214 nm)

14

Time (min) Peak Number 1

tR /min

Protein

6.89

Cytochrome C (12 kDa)

2

7.34

Insulin (6 kDa)

3

8.77

Myoglobin (18 kDa)

4

9.57

Carbonic anhydrase (30 kDa)

5

11.02

Ovalbumin (45 kDa)

*

Carbonic anhydrase impurity

Base peak 50 fmol loading of BSA digest 18.40

100 90 80

Relative Abundance

Mobile phase A: 0.1 % formic acid in water

22.56 23.81

18.02

70

Mobile phase B: 90 % acetonitrile in water

19.10

16.14

Gradient:

60 22.43

50

24.98

27.39

95 % B hold for 2 mins

26.68

40

28.77

30

20.05

14.80

20.16

14.36

20 6.42

10

2.00

3.89

31.64

35.33

22.18

32.10

5.74

37.80

0 0

2

4

6

8

10

12

14

16

18

20

Time (min)

12

Flow:

300 nL/min

Temperature:

not controlled

Column:

Accucore 150-C18, 2.6 µm, 150 x 75 µm

Backpressure:

198 bar (100 % A)

Injection:

Direct on-column loading of 1 µL of BSA digest, 50 fmol/µL in water + 0.1% formic acid

Detection:

Thermo Scientific LTQ Orbitrap XL Mass Spectrometer coupled with a Proxeon Nano Spray Flex Ion Source

36.03

6.60 6.69 9.55 11.21 11.49 7.57 11.92

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

22

24

26

28

4-40 % B over 30 mins 40-95 % B over 2 mins

30.07

30

32

34

36

Ordering Information Accucore HPLC Columns Description

Particle Size

Accucore 150-C18

2.6 µm

Accucore 150-C4

2.6 µm

Length (mm)

2.1 mm ID

3.0 mm ID

4.6 mm ID

30 50 100 150 30 50 100 150

16126-032130 16126-052130 16126-102130 16126-152130 16526-032130 16526-052130 16526-102130 16526-152130

16126-033030 16126-053030 16126-103030 16126-153030 16526-033030 16526-053030 16526-103030 16526-153030

16126-034630 16126-054630 16126-104630 16126-154630 16526-034630 16526-054630 16526-104630 16526-154630

Accucore Defender Guard Columns (4/pk) Description Accucore 150-C18 Accucore 150-C4

Particle Size

Length (mm)

2.1 mm ID

3.0 mm ID

4.6 mm ID

2.6 µm 2.6 µm

10 10

16126-012105 16526-012105

16126-013005 16526-013005

16126-014005 16526-014005

UNIGUARD Direct-Connection Guard Cartridge Holders Description UNIGUARD Drop-In Guard Cartridge Holder Standard Replacement Tip

2.1 mm ID

3.0 mm ID

4.6 mm ID

852-00 850-RT

852-00 850-RT

850-00 850-RT

Accucore nanoViper Columns Description

Particle Size

Accucore 150-C18

2.6 µm

Accucore 150-C4

2.6 µm

Length (mm)

75 µm ID

150 500 150 500

16126-157569 16126-507569 16526-157569 16526-507569

Ultimate Core Performance

to Maximize Your Investment • 150 Å pore size solid core particles for fast biomolecule separations • Superb resolution of peptides and intact proteins at low backpressures • Exceptionally rugged and easy to use analytical and nano scale columns

Thermo Scientific Accucore HPLC Columns for Biomolecule Separations

13

Resources

for Chromatographers Thermo Scientific Chromatography Columns and Consumables Catalog This extensive catalog offers 600 pages of proven chromatography tools and product selection guides. Available online, with a robust search tool and optimized for your iPad®. Visit www.thermoscientific.com/catalog

Chromatography Resource Center Our web-based resource center provides technical support, applications, technical tips and literature to help move your separations forward. Visit www.thermoscientific.com/crc

For more information visit: www.thermoscientific.com/accucore © 2012 Thermo Fisher Scientific Inc. All rights reserved. iPad is a registered trademark of Apple Inc., registered in the US and other countries. Agilent is a registered trademark of Agilent Technologies Inc. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.

USA and Canada +1 800 332 3331 France +33 (0)1 60 92 48 34 Germany +49 (0) 2423 9431 20 or 21 United Kingdom +44 (0)1928 534110 Japan +81 3 5826 1615

China +86 21 68654588 +86 10 84193588 +86 20 83145199 800 810 5118 India +91 22 6742 9494 +91 27 1766 2352 Australia 1 300 735 292 (free call domestic) New Zealand 0800 933 966 (free call domestic) All Other Enquiries +44 (0) 1928 534 050

Technical Support

North America +1 800 332 3331 Outside North America +44 (0) 1928 534 440 TG20502_E 05/12S