AdaptaBeacon® Heavy Duty Strobe - Edwards Signaling

Report 16 Downloads 62 Views
VISUAL SIGNALS

AdaptaBeacon® Heavy Duty Strobe Single and Double Flash 94 & 94DF Series FEATURES > Weatherproof

The Edwards 94 Series AdaptaBeacon Heavy Duty strobe lights are

> Optically designed fresnel lens > Easily cleaned shatter resistant polycarbonate dust cover

for use where more frequent and longer lasting signaling cycles may be required. They are designed to maximize the strobe tube brilliance. This is accomplished with a series of complementing fresnels that cause the dome to "fill" with light each time the strobe

> Six lens colors available

flashes. This design feature increases the AdaptaBeacon "on-time",

> Immune to shock and vibration

thus improving viewer perception. These strobes are also available

> Cast base may be used as a junction box AGENCY APPROVALS

in "double flash" versions that double the on-time (50 double flashes per minute). The 94 Series' trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced as it is

> UL 1638 Listed

necessary to replace only the strobe tube.

> cUL Listed

The 94 Series is also ideally suited for installations where high ambient light levels make traditional rotating or flashing lights difficult to distinguish. The gasketed weatherproof design assures installation acceptability in most industrial and commercial locations. They are often used to signal equipment malfunctions,

3-44

D-04

security intrusions, or pinpointing problem locations.

90 Fieldstone Court | Ph: 203.699.3300 |

Cheshire, CT 06410 Fx: 203.699.3108

www.edwards-signals.com

© Copyright 2004 Edwards

VISUAL SIGNALS TECHNICAL INFORMATION

7 7/8" (200mm)

3/4" (19mm) conduit hole 8 1/16" (205mm)

Cat. No. 94R-N5 94A-N5 94B-N5 94G-N5 94M-N5 94C-N5 94R-R5 94A-R5 94B-R5 94G-R5 94M-R5 94C-R5 94DFR-N5 94DFA-N5 94DFB-N5 94DFG-N5 94DFM-N5 94DFC-N5 94DFR-R5 94DFA-R5 94DFB-R5 94DFG-R5 94DFM-R5 94DFC-R5

Lens Color

Type Flash

Replacement Lens

Electrical Ratings

Replacement Strobe Tube

Peak Candlepower

Replacement Dome

Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear

Single 65 FPM

93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC

120V 50/60 Hz 0.10 Amp

92-ST 3,000 hour*

800,000 cd

94-DC

240V 50/60 Hz 0.05 Amp

92-ST 3,000 hour*

800,000 cd

94-DC

120V 50/60 Hz 0.10 Amp

92-ST 3,000 hour*

1,100,000 cd

94-DC

240V 50/60 Hz 0.05 Amp

92-ST 3,000 hour*

1,100,000 cd

94-DC

Single 65 FPM

Double 50 DFPM

Double 50 DFPM

*Calculated at operating power to 75% efficiency.

D-04

90 Fieldstone Court | Ph: 203.699.3300 |

Cheshire, CT 06410 Fx: 203.699.3108

www.edwards-signals.com

3-45