A STRO 2 HOT WATER R E- CIRCU L ATIO N SYSTEM |
File No: 10.585 Date: july 14, 2015 Supersedes: 10.585 Date: april 4, 2011
S U B M I T TA L Job: Representative: Ordered by: Engineer:
Submitted by: Date:
Contractor: Approved by:
quantity
Date:
tag no.
model no.
flow (USgpm)
t ec h n i c a l data Power connection: 6.0 ft (1.8 m) power cord, molded duplex plug with ground Environment: Indoor use only Max. working pressure: 150 psi (1034 kpa) Ambient temperature: 39°f (4°c) to 104°f (40°c) Max. water temperature: 230°f ( 110°c) Low temperature switchpoint1 : 85°f (29°c) ± 10%
head (feet)
Date:
comments
h ot wat e r r e- c i rcu l at i o n s yst em a ppli c at i o n s Armstrong Astro 2 hot water re-circulation systems automatically circulate water through domestic hot water distribution pipes. This helps to ensure that everyone in the household has 'instant' hot water at the tap when they need it, while also helping to conserve water and save water heating energy costs. All systems are assembled, wired, tested and then shipped from the factory, ready for installation.
High temperature switchpoint1 : 105°f (40°c) ± 10% Clock/timer: 12 hour analog clock with am/pm indication Timer settings: Individual mechanical toggles for each 15 minute interval over 24 hours Manual override: 3 position slide switch, on/off/auto Approvals:
Pump casing: Lead free bronze* (bs models), Stainless steel* (ss models) Pump shaft: Ceramic
certified
note: 1
listed
m at e r ia l s o f co n st ru c t i o n
(Wetted parts)
High/low temperature switchpoints are as measured on pipe surface with the Aquastat (ta models only).
Impeller: Noryl Bearings: Ceramic note:
* Complies with section 116875 at the California Health and Safety/Code and Vermont Act 193 (Lead content of wetted surface is 0.25% or less)
s u bmit tal
Astro 2 Hot water re-circulation systems
2
dimensions model
a
b
c
d
e
f
a stro 2 25bs
5 . 0 0 (127)
5 . 4 6 (13 9)
4 . 59 (117)
2 .72 (69)
1 . 87 (4 8)
5 . 4 3 (13 8)
a stro 2 20/ 2 25 ssu
5 .9 8 (152)
5 . 62 (14 3)
4 . 3 8 (111)
2 .72 (69)
1 . 87 (4 8)
5 . 4 3 (13 8)
a stro 2 3 0/ 250ss
6 . 3 8 (162) 6 . 49 (16 5)
4 . 52 (115)
2 .72 (69)
1 . 8 2 (4 6)
5 . 4 3 (13 8)
note: All dimensions are in inches (mm)
astro 225bs f
e
b
d a
c
astro 220/225ssu f
b
e
d a
c
astro 230/250ss f
e
b
d a
c
Astro 2 Hot water re-circulation systems
subm i tta l 3
item
model
connection size
cord timer aquastat electrical data
weight
11 02 2 3 b- 140
a stro 2 20ssu 0 50s-ta* Sweat
½"
ü
ü
ü
115 Vac, 60 Hz, 0.29 A, 33W
7. 5 0 (3 . 4 0)
11 02 2 3 b- 141
a stro 2 20ssu 075 s-ta* Sweat
¾"
ü
ü
ü
115 Vac, 60 Hz, 0.29 A, 33W
7. 5 0 (3 . 4 0)
11 02 2 3 b- 14 2
a stro 2 25bs0 50s-ta
Sweat
½"
ü
ü
ü
115 Vac, 60 Hz, 0.64 A, 75W
7. 0 0 (3 .18)
11 02 2 3b- 143
a stro 2 25bs075 s-ta
Sweat
¾"
ü
ü
ü
115 Vac, 60 Hz, 0.64 A, 75W
7. 0 0 (3 .18)
11 02 2 3b- 14 4
a stro 2 20ssu -ta
npsm union
1¼"
ü
ü
ü
115 Vac, 60 Hz, 0.29 A, 33W
7. 5 0 (3 . 4 0)
11 02 2 3b- 145
a stro 2 25 ssu -ta
npsm union
1¼"
ü
ü
ü
115 Vac, 60 Hz, 0.69 A, 83W
7. 5 0 (3 . 4 0)
11 02 2 3b- 14 8
a stro 2 3 0ss-ta
2 bolt flange
2 bolt flange
ü
ü
ü
115 Vac, 60 Hz, 0.81 A, 97W
10 . 0 0 (4 . 54)
11 02 2 3b- 149
a stro 250ss-ta
2 bolt flange
2 bolt flange
ü
ü
ü
115 Vac, 60 Hz, 0.98 A, 117W 10 . 0 0 (4 . 54)
11 02 2 3b-2 40
a stro 2 20ssu 0 50s-t*
Sweat
½"
ü
ü
—
115 Vac, 60 Hz, 0.29 A, 33W
7. 5 0 (3 . 4 0)
11 02 2 3b-2 41
a stro 2 20ssu 075 s-t*
Sweat
¾"
ü
ü
—
115 Vac, 60 Hz, 0.29 A, 33W
7. 5 0 (3 . 4 0)
11 02 2 3b-2 4 2
a stro 2 25bs0 50s-t
Sweat
½"
ü
ü
—
115 Vac, 60 Hz, 0.64 A, 75W
7. 0 0 (3 .18)
11 02 2 3b-2 43
a stro 2 25bs075 s-t
Sweat
¾"
ü
ü
—
115 Vac, 60 Hz, 0.64 A, 75W
7. 0 0 (3 .18)
11 02 2 3b-2 4 4
a stro 2 20ssu -t
npsm union
1¼"
ü
ü
—
115 Vac, 60 Hz, 0.29 A, 33W
7. 5 0 (3 . 4 0)
11 02 2 3b-2 45
a stro 2 25 ssu -t
npsm union
1¼"
ü
ü
—
115 Vac, 60 Hz, 0.69 A, 83W
7. 5 0 (3 . 4 0)
11 02 2 3b-2 4 8
a stro 2 3 0ss-t
2 bolt flange
2 bolt flange
ü
ü
—
115 Vac, 60 Hz, 0.81 A, 97W
10 . 0 0 (4 . 54)
11 02 2 3b-2 49
a stro 250ss-t
2 bolt flange
2 bolt flange
ü
ü
—
115 Vac, 60 Hz, 0.98 A, 117W 10 . 0 0 (4 . 54)
11 02 2 3 -3 40
a stro 2 20ssu 0 50s-lc* Sweat
½"
ü
—
—
115 Vac, 60 Hz, 0.29 A, 33W
7. 0 0 (3 .18)
11 02 2 3 -3 41
a stro 2 20ssu 075 s-lc* Sweat
¾"
ü
—
—
115 Vac, 60 Hz, 0.29 A, 33W
7. 0 0 (3 .18)
11 02 2 3 -3 4 2
a stro 2 25bs0 50s-lc
Sweat
½"
ü
—
—
115 Vac, 60 Hz, 0.64 A, 75W
6 . 5 0 (2 .9 5)
11 02 2 3 -3 43
a stro 2 25bs075 s-lc
Sweat
¾"
ü
—
—
115 Vac, 60 Hz, 0.64 A, 75W
6 . 5 0 (2 .9 5)
11 02 2 3 -3 4 4
a stro 2 20ssu - lc
npsm union
1¼"
ü
—
—
115 Vac, 60 Hz, 0.29 A, 33W
7. 0 0 (3 .18)
11 02 2 3 -3 45
a stro 2 25 ssu -lc
npsm union
1¼"
ü
—
—
115 Vac, 60 Hz, 0.69 A, 83W
7. 0 0 (3 .18)
11 02 2 3 -3 4 8
a stro 2 3 0ss-lc
2 bolt flange
2 bolt flange
ü
—
—
115 Vac, 60 Hz, 0.81 A, 97W
9. 0 0 (4 . 0 8)
11 02 2 3 -3 49
a stro 250ss-lc
2 bolt flange
2 bolt flange
ü
—
—
115 Vac, 60 Hz, 0.98 A, 117W 9. 0 0 (4 . 0 8)
note: All weights are in lbs. (kg) *Union model with sweat hardware kit.
performance curve astro 220ss
astro 225ss
5.5
14
5
10
2
head - feet
head - feet
4
1
3 2 1 0
3 2
12
3
1
8 6 4 2 0
0
2
4
6 8 flow - usgpm
10
12
0
2
4
6
8
flow - usgpm
10
12
14
Astro 2 Hot water re-circulation systems
s u bmit tal 4
astro 225bs
12
astro 230ss 20
3
18
2
10
16
2
14
8 head - feet
head - feet
1
6 4
3
12
1
10 8 6 4
2
2
0
0
1
2
3
4
5
6
7
8
0
9
0
2
4
6
flow - usgpm
8
10
12
14
16
18
14
16
18
flow - usgpm astro 250ss 25 3 20 head - feet
2 15 10
1
5 0 0
2
4
toronto
buffalo +1 716 693 8813
birmingham +44 (0) 8444 145 145
manchester +44 (0) 8444 145 145
bangalore +91 (0) 80 4906 3555
+86 21 3756 6696
8
10
12
flow - usgpm
+1 416 755 2291
shanghai
6
a r m s t r o n g f lu i d t e c h n o lo g y established 1934
a r m s t r o n g f lu i d t e c h n o lo g y. c o m