Flamelite (S) Pte Ltd
CIDB Registered Contractor Grade : L3 Type : CR 16 CSN No. 199205533R-PTE-01 GST Reg. No. M2-0109914-5
No. 29 Mandai Industrial Estate #01 -05 hmovation Place, Tower 3 Singapore 729932 Tel: 6468 3166 Fax: 6468 7266 Email Address :
[email protected] Website: www.flamelite.com. sg
80--la:l~~ M) ~ i$ ~
Compartment-Lite : Total concept structural safety fire rated glass system. (Impact resistance, anti shattering and fire resistance) 1. For Specification :To ensure quality and reliability, please specify "Compartment-Lite" structural safety laminated fire resistance glass system by "Fiamelite (S) Pte Ltd .. ..... .. ........ ".
2. Introduction :Compartment-Lite structural fire rated glass screen system consists of fire rated glass fixed screen and door system. The system was developed to meet fire resistance requirement ofBS476 pt 22-23 from half hour to four hours in term of stability, integrity and insulation. This system used laminated safety glass aimed at preventing cutting injuries and prohibiting forced entry.
3. Types Of Fixed Screen System
Rating System
1 Hour
2 Hours
4 Hours -
Fixed Glass Panel Glass Thickness Size l(mm) I(Per Panel) SlO SOl S04 S02
12 11 17 12
1220 X 2440 1220 X 2440 1400 X 3000 1220 X 2440
S06 Sl2 SlO S07 Sll
12 56 12 11 43
1220 X 2440 1700 X 2700 1220 X 2440 1220 X 2440 1220 X 2440
Frame Size (TxW)
Remarks
50 X 75 Frameless 67 X 75 Horizontial 142 X 100 74 X 100 107 X 100 50 X 75 55 X 100 92 X 100
Non-Insulated Non-Insulated Insulated Glass Non-Insulated Non-Insulated Insulated Glass Smoke Screen Non-Insu lated Non-Insulated 4 hrs. Integrity & 2 hrs. Insulated
4. Types Of Doors
Rating System
1 Hour
Glass Panel Glass Thickness (mm)
D03 DOl
12 21
2 Hours
D04
4 Hours
DOS
Panel's Door Remarks Size Frame Size Frame (Per Panel) (TxW) Size 1004 1018
X
2440 2216
50 X 75 68 X 100
50 68
X
X
X
35 50
Non-Insulated Glass Insulated Glass
12
1220
X
2567
74
X
100
92
X
50
Non-Insu lated Glass
11
1220
X
2572
55
X
100
55
X
59
Non-Insulated Glass
5. Glass Glass used in Compartment-Lite system is made of high temperature resistance glass bonded with special resin against impact and cutting injuries. This structural safety glass will be shatter proof. It will deter forced/unauthorized instruction due to its toughened membrance. The glass is highly polished. Its optical clarity is equivalent to that of clear float glass. The glass has been tested to withstand mechanical impact and BS6206, AS2208 & BS 5544. It has passed the test without penetration. It is safety glass because it will not cut when broken. The glass used can be laminated in colour, texture or sand blasted. The glass has been subjected to boi ling test. This test will ensure the lamination will not form bubbles when subject to solar radiation and effect of inclement weather.
!
Flamelite (S) Pte Ltd No. 29 Mandai Industrial Estate #01-05 Innovation Place, Tower 3 Singapore 729932 Tel: 6468 3166 Fax: 6468 7266 Email Address :
[email protected] Website: www.flamelite.com.sg
CIDB Registered Contractor Grade : L3 Type : CR 16 CSN No. 199205533R-PTE-01 GST Reg. No. M2-0109914-5
IG il
_,~
l·l~
6.Frame The framing used is structural framing. It consists of a structural steel core and cladded with fire rated materials. In some systems, solid timber framing is used. All the framing system has been tested and passed the requirement stipulated under the bye-laws and regulations.
7. Finishes The glass can be sandblasted, curved or etched. The frame can be cladded with :- I ) Aluminium in coating II ) timber veneer III) Stainless steel IV) Others
8. Bye Laws And Regulations a) Fire Safety I II III IV
) BS 476 pt 22- 23 for stability, integrity and insulation. ) Singapore standard 332 : 2007 for fire resistance door. ) Cyclic movement test. ) FSB I PSB certification and listing.
b) Mechanical Test I ) BS 6206 classification A against mechanical impact of 600N. II ) As 2208 - resistance against shattering. III) BS 5544: 1978 specification for Anti-Bandit glazing with boiling test.
c) Hose Stream Test The glass shall be able to take thermal shock by hose stream test. The water presure is 45 psi at the rate of 1 sf per 3 sec. No breakage or through opening shall be developed.
9. Consulatancy Our fire safety experts will offer advice and consultation on :I ) Product approval. II ) FSB application. III ) PSB labeling. IV ) FSB certification for CSC application. V ) Interpretation of code of fire precaution 1997.
FLAME LITE (S) PTE LTD No. 29 Mandai Industrial Estat #01-05 Innovation Place, Tower 3 Singapore 729932 Tel : 6468 3166 Fax : 6468 7266 Email Address :
[email protected] Website: www.flamelite.com.sg
CIDB Registered Contractor Grade : L3 Type : CR 16 CSN No. 199205533R-PTE-01 GST Ree. No. M2-0109914-5
r ·~
O l '-~ J
.
l ,;
lGI ~ B;:! ;a:t ~ ~ ~ ~
Compartment-Lite Fire Rated Double Leaves Glass Door
C=-o
XL;":·.o
FLAMELITE (S) PTE LTD No. 29 Mandai Industrial Estate #01-05 Innovation Place, Tower 3 Singapore 729932 Tel : 6468 3166 Fax : 6468 7266 Email Address :
[email protected] Website: www.flamelite.com.sg
CIDB Registered Contractor Grade : L3 Type : CR 16 CSN No. 199205533R-PTE-01 GST Reg. No. M2-0109914-5 a=> :a:.~~
..e ..... ~ ~
Compartment-Lite Fire Rated Unequal Leave Glass Door
FLAMELITE (S) PTE LTD No. 29 Mandai Industrial Estate #01-05 Innovation Place, Tower 3 Singapore 729932 Tel : 6468 3166 Fax : 6468 7266 Email Address :
[email protected] Website : www.tlamelite.com.sg
,.,!B
8