T30 Series NAMUR Fixed-Field Sensors For Intrinsically Safe Operation in Hazardous Areas
Features • Intrinsically safe sensors featuring EZ-BEAM® technology; the specially designed optics and electronics provide reliable sensing without the need for adjustments • “T” style plastic housing with 30 mm threaded lens • Completely epoxy-encapsulated to provide superior durability, even in harsh sensing environments rated to IP69K • Innovative dual-indicator system takes the guesswork out of sensor performance monitoring • Advanced diagnostics to warn of marginal sensing conditions or output overload • 5 to 15V dc; constant current output
Models Far-Limit Cutoff
Models
LED
Supply Voltage
Excess Gain
Performance based on use of a 90% reflectance white test card.† 1000
T30AD9FF150 (2 m cable) 150 mm (6") T30AD9FF150Q (4-pin Euro-style QD fitting)
Infrared 880 nm
5 to 15V dc
E X C E S S G A I N
T30 NAMUR Fixed-Field
100
†Using
18% gray test card: Cutoff distance will be 95% of value shown. †Using 6% black test card: Cutoff distance will be 90% of value shown.
10
1 1 mm (0.04")
10 mm (0.4")
100 mm (4")
1000 mm (40")
DISTANCE
* A model with a QD connector requires a mating cable; see page 11.
WARNING . . . Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Series — NAMUR Fixed-Field Sensors Fixed-Field Mode Overview T30 Series self-contained fixed-field sensors are small, powerful, infrared diffuse mode sensors with far-limit cutoff (a type of background suppression). Their high excess gain and fixed-field technology allow them to detect objects of low reflectivity, while ignoring background surfaces.
Receiver Elements Near R1 Detector
Cutoff Distance Object B or Background
Object A Lenses
Far R2 Detector
The cutoff distance is fixed. Backgrounds and background objects must always be placed beyond the cutoff distance.
Fixed-Field Sensing – Theory of Operation
The T30FF compares the reflections of its emitted light beam (E) from an object back to the sensor’s two differently aimed detectors, R1 and R2 (see Figure 1). If the near detector (R1) light signal is stronger than the far detector (R2) light signal (see object A, closer than the cutoff distance), the sensor responds to the object. If the far detector (R2) light signal is stronger than the near detector (R1) light signal (see object B, beyond the cutoff distance), the sensor ignores the object.
Emitter
E Sensing Range Object is sensed if amount of light at R1 is greater than the amount of light at R2
Figure 1. Fixed-field concept
The cutoff distance for model T30FF NAMUR sensors is fixed at 150 millimeters (6"). Objects lying beyond the cutoff distance are usually ignored, even if they are highly reflective. However, it is possible to falsely detect a background object, under certain conditions (see Background Reflectivity and Placement). In the drawings and discussion on these pages, the letters E, R1, and R2 identify how the sensor’s three optical elements (Emitter “E”, Near Detector “R1”, and Far Detector “R2”) line up across the face of the sensor. The location of these elements defines the sensing axis (see Figure 2). The sensing axis becomes important in certain situations, such as those illustrated in Figures 5 and 6.
Sensor Setup Sensing Reliability
For highest sensitivity, position the target object for sensing at or near the point of maximum excess gain. The excess gain curve for this product is shown in the models table. Maximum excess gain occurs at a lens-to-object distance of about 40 mm (1.5"). Sensing at or near this distance will make maximum use of each sensor’s available sensing power. The background must be placed beyond the cutoff distance. (Note that the reflectivity of the background surface also may affect the cutoff distance.) Following these two guidelines will improve sensing reliability.
R1 R2
Sensing Axis
E
Background Reflectivity and Placement
Avoid mirror-like backgrounds that produce specular reflections. False sensor response will occur if a background surface reflects the sensor’s light more strongly to the near detector, or “sensing” detector (R1), than to the far detector, or “cutoff” detector (R2). The result is a false ON condition (Figure 3). To cure this problem, use a diffusely reflective (matte) background, or angle either the sensor or the background (in any plane) so the background does not reflect light back to the sensor (see Figure 4). Position the background as far beyond the cutoff distance as possible.
As a general rule, the most reliable sensing of an object approaching from the side occurs when the line of approach is parallel to the sensing axis.
Figure 2. Fixed-field sensing axis
An object beyond the cutoff distance, either stationary (and when positioned as shown in Figure 5), or moving past the face of the sensor in a direction perpendicular to the sensing axis, can cause unwanted triggering of the sensor if more light is reflected to the near detector than to the far detector. The problem is easily remedied by rotating the sensor 90° (Figure 6). The object then reflects the R1 and R2 fields equally, resulting in no false triggering. A better solution, if possible, may be to reposition the object or the sensor.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Series — NAMUR Fixed-Field Sensors Color Sensitivity
The effects of object reflectivity on cutoff distance, though small, may be important for some applications. It is expected that at any given cutoff setting, the actual cutoff distance for lower reflectance targets will be slightly shorter than for higher reflectance targets (see Figure-of-Merit information on page 1). This behavior is known as color sensitivity. For example, an excess gain of 1 for an object that reflects 1/10 as much light as the 90% white card is represented by the horizontal graph line at excess gain = 10. An object of this reflectivity results in a far limit cutoff of approximately 130 mm (5"), for example; thus 130 mm represents the cutoff for this sensor and target. These excess gain curves were generated using a white test card of 90% reflectance. Objects with reflectivity of less than 90% reflect less light back to the sensor, and thus require proportionately more excess gain in order to be sensed with the same reliability as more reflective objects. When sensing an object of very low reflectivity, it may be especially important to sense it at or near the distance of maximum excess gain.
Cutoff Distance
Cutoff Distance
Reflective Background
R1 = Near Detector R2 = Far Detector E = Emitter T30FF R1 R2 E
T30FF
Strong Direct Reflection to R1
Core of Emitted Beam
Reflective Background
Fixed Sensing Field
R1 R2 E
Fixed Sensing Field
Core of Emitted Beam
Strong Direct Reflection Away From Sensor
R1 = Near Detector R2 = Far Detector E = Emitter
Figure 3. Reflective background – problem
Cutoff Distance
Cutoff Distance
T30FF
Figure 4. Reflective background – solution
T30FF
R1 R2
E, R2, R1
E
Fixed Sensing Field R1 = Near Detector R2 = Far Detector E = Emitter
Fixed Sensing Field Reflective Background or Moving Object
A reflective background object in this position or moving across the sensor face in this axis and direction may cause false sensor response.
Figure 5. Object beyond cutoff – problem
E = Emitter R2 = Far Detector R1 = Near Detector
Reflective Background or Moving Object
A reflective background object in this position or moving across the sensor face in this axis will be ignored.
Figure 6. Object beyond cutoff – solution
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Series — NAMUR Fixed-Field Sensors Specifications Supply Voltage and Current
5 to 15V dc (provided by the amplifier to which the sensor is connected)
Output
Constant current output; ≤1.2 mA in the “dark” condition and ≥2.1 mA in the “light” condition
Output Response Time
10 ms on/off (does not include amplifier response)
Sensing Beam
Infrared (880 nm)
Cutoff Distance
150 mm (6"), referenced to a 90% reflectance white test card. See excess gain curve.
Indicators
Red indicator LED on rear panel lights when the sensor sees a “light” condition.
Construction
Yellow PBT enclosure, PBT rear cover. Acrylic lens. M30xl,5 threaded lens housing with two mounting nuts supplied. Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 6, 6P, 12, and 13. IEC IP67.
Connections
2 m (6.5') attached PVC covered cable or 4-pin Euro-style quick-disconnect (QD) fitting, depending on model. QD cable must be purchased separately; see page 5.
Operating Conditions
Temperature: -40° to +70° C (-40° to +158° F)
Vibration and Mechanical Shock
Meets Mil. Std. 202F requirements. Method 201A (Vibration: frequency 10 to 60 Hz max., double amplitude 0.06-inch, maximum acceleration 10G). Method 213B conditions H & I (Shock: 75G with unit operating; 100G for non-operation).
Design Standards
T30AD9 sensors comply with the following standards: DIN 19 234 NAMUR, EN 50 014 Part L 1977, EN 50 020 Part 7. 1977, Factory Mutual Research 3610, Factory Mutual Research 3611, CSA-22.2 No. 157-92 NOTE: If sensors with output characteristics according to DIN 19 234 (e.g., T30AD9 Series NAMUR sensors) are used in hazardous areas, they must be used with approved switching amplifers with intrinsically safe input circuits.
Certifications
Approvals KEMA:
EN50014, EN50020 DIN 19234 NAMUR II 1 G EEx ia IIC T6 KEMA No. EX95.C.3442 Ta -40 C° .. 70 C° 03ATEX1441X
Dimensions ø 40.0 mm (1.57")
Cabled Models
QD Models
Jam Nut (Supplied) M30 x 1.5 Thread
ø 15 mm (0.59")
45.0 mm (1.77") Red LED Alignment Indicator 51.5 mm (2.03") 11.5 mm (0.45")
66.5 mm (2.62")
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Series — NAMUR Fixed-Field Sensors Hookups Cabled Models Hazardous Area
Entity Parameters
Non-hazardous Area
NAMUR Sensor
Associated Apparatus 1
br
2
bu
3
+
+ Sensor Power – Input
–
≤ 15V dc
4 Output
Quick-Disconnect Models Hazardous Area NAMUR Sensor
bu
Voc ≤ 15V dc Isc ≤ 35 mA Ca ≥ *C (cable) + Ci La ≥ *L (cable) + Li
Vmax = 15V dc Imax = 35 mA Ci = 0 Li = 0 Pi = 131
*C(cable) = 60 pF/ft
*L(cable) = 0.2 uH/ft
Associated apparatus may include amplifiers and barriers to monitor apparatus supply current which is the apparatus output signal. Associated apparatus must limit both supply voltage and supply current in the event of failures.
Non-hazardous Area
Power + Sensor – Input
Sensor Apparatus
HAZARDOUS AREA APPLICATION:
Associated Apparatus
br
Associated Apparatus
+ –
≤ 15V dc
Output
Quick-Disconnect (QD) Cables Style 4-pin Euro-style Straight
Model
Length
MQD9-406 MQD9-415
2 m (6.5') 5 m (15')
Dimensions
Pinout ø 15 mm (0.6")
44 mm max. (1.7")
M12 x 1
Blue Wire Brown Wire
38 mm max. (1.5")
4-pin Euro-style Right-angle
MQD9-406RA MQD9-415RA
2 m (6.5') 5 m (15')
38 mm max. (1.5")
M12 x 1 ø 15 mm (0.6")
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Series — NAMUR Fixed-Field Sensors Mounting Brackets T30 Series sensors may also be mounted in a 30 mm clearance hole up to 15 mm (0.6") deep, using the supplied jam nut(s). • 30 mm 12-gauge, 304 stainless steel, right-angle mounting bracket with a curved mounting slot for versatility and orientation
SMB30A
• 30 mm swivel bracket • Black reinforced thermoplastic polyester
SMB30SC
• Includes stainless steel mounting and swivel locking hardware
• Clearance for M6 (1/4") hardware
38.5 mm (1.52")
45 mm (1.8")
61 mm (2.40")
30
R 40 mm (1.58")
ø 6.3 mm (0.25")*
69 mm (2.70") 6.3 mm (0.25")*
7.6 mm (0.30")
ø 30.5 mm (1.20")
Clearance for M6 (1/4") mounting hardware (not included) 50.8 mm (2.00")
M30 x 1.5 internal thread
12.7 mm (0.50")
58.7 mm (2.31") 30.0 mm (1.18")
* Use 5 mm (#10) screws to mount bracket. Drill screw holes 40.0 mm (1.58") apart. 66.5 mm (2.62")
29.0 mm (1.14")
SMB3OA BRACKET
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 41685 rev. A
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Sensors – ac-Voltage Series Self-contained ac-operated sensors
Features • F eaturing EZ-BEAM® technology, the specially designed optics and electronics provide reliable sensing without the need for adjustments • “ T”-style plastic housing with 30 mm threaded lens in opposed, retroreflective or fixed-field modes • C ompletely epoxy-encapsulated to provide superior durability, even in harsh sensing environments rated to IP69K • Innovative dual-indicator system takes the guesswork out of sensor performance monitoring • 20 to 250V ac (3-wire hookup); SPST solid-state switch output, maximum load 300 mA
Models Sensing Mode
Range
LED
Output –
Opposed
Polarized Retroreflective
60 m (200')
6 m (20')
Infrared 950 nm
Visible Red 680 nm
200 mm (8") cutoff
Fixed-Field
400 mm (16") cutoff
600 mm (24") cutoff
Infrared 880 nm
Model* T303E
LO
T30AW3R
DO
T30RW3R
LO
T30AW3LP
DO
T30RW3LP
LO
T30AW3FF200
DO
T30RW3FF200
LO
T30AW3FF400
DO
T30RW3FF400
LO
T30AW3FF600
DO
T30RW3FF600
* Standard 2 m (6.5') cable models are listed. • For 9 m (30') cable: add suffix “W/30” (e.g., T303E W/30). • For 4-pin Micro-style integral QD: add suffix “Q1” (e.g., T303EQ1). A model with a QD connector requires a mating cable; see page 7.
WARNING . . . Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Sensors – ac-Voltage Series Fixed-Field Mode Overview
T30 Series self-contained fixed-field sensors are small, powerful, infrared diffuse mode sensors with far-limit cutoff (a type of background suppression). Their high excess gain and fixed-field technology allow them to detect objects of low reflectivity, while ignoring background surfaces. The cutoff distance is fixed. Backgrounds and background objects must always be placed beyond the cutoff distance.
Fixed-Field Sensing – Theory of Operation
The T30FF compares the reflections of its emitted light beam (E) from an object back to the sensor’s two differently aimed detectors, R1 and R2 (see Figure 1). If the near detector (R1) light signal is stronger than the far detector (R2) light signal (see object A, closer than the cutoff distance), the sensor responds to the object. If the far detector (R2) light signal is stronger than the near detector (R1) light signal (see object B, object beyond the cutoff distance), the sensor ignores the object. The cutoff distance for model T30FF sensors is fixed at 200, 400 or 600 millimeters (8", 16", or 24"). Objects lying beyond the cutoff distance are usually ignored, even if they are highly reflective. However, it is possible to falsely detect a background object, under certain conditions (see Background Reflectivity and Placement). In the drawings and discussion on these pages, the letters E, R1, and R2 identify how the sensor’s three optical elements (Emitter “E”, Near Detector “R1”, and Far Detector “R2”) line up across the face of the sensor. The location of these elements defines the sensing axis (see Figure 2). The sensing axis becomes important in certain situations, such as those illustrated in Figures 5 and 6.
Receiver Elements Near R1 Detector
Cutoff Distance Object B or Background
Object A Lenses
Far R2 Detector
Emitter
E Sensing Range Object is sensed if amount of light at R1 is greater than the amount of light at R2
Figure 1. Fixed-field concept
Sensor Setup Sensing Reliability
For highest sensitivity, position the target object for sensing at or near the point of maximum excess gain. The excess gain curves for these sensors are shown on page 5. Maximum excess gain for all models occurs at a lens-to-object distance of about 40 mm (1.5"). Sensing at or near this distance will make maximum use of each sensor’s available sensing power. The background must be placed beyond the cutoff distance. (Note that the reflectivity of the background surface also may affect the cutoff distance.) Following these two guidelines will improve sensing reliability.
R1 R2
Sensing Axis
E
Background Reflectivity and Placement
Avoid mirror-like backgrounds that produce specular reflections. False sensor response will occur if a background surface reflects the sensor’s light more strongly to the near detector, or “sensing” detector (R1), than to the far detector, or “cutoff” detector (R2). The result is a false ON condition (Figure 3). To cure this problem, use a diffusely reflective (matte) background, or angle either the sensor or the background (in any plane) so the background does not reflect light back to the sensor (see Figure 4). Position the background as far beyond the cutoff distance as possible. An object beyond the cutoff distance, either stationary (and when positioned as shown in Figure 5), or moving past the face of the sensor in a direction perpendicular to the sensing axis, can cause unwanted triggering of the sensor if more light is reflected to the near detector than to the far detector. The problem is easily remedied by rotating the sensor 90° (Figure 6). The object then reflects the R1 and R2 fields equally, resulting in no false triggering. A better solution, if possible, may be to reposition the object or the sensor.
As a general rule, the most reliable sensing of an object approaching from the side occurs when the line of approach is parallel to the sensing axis.
Figure 2. Fixed-field sensing axis
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Sensors – ac-Voltage Series Color Sensitivity
The effects of object reflectivity on cutoff distance, though small, may be important for some applications. It is expected that at any given cutoff setting, the actual cutoff distance for lower reflectance targets will be slightly shorter than for higher reflectance targets (see Figure-of-Merit information on page 5). This behavior is known as color sensitivity. For example, an excess gain of 1 (see page 5) for an object that reflects 1/10 as much light as the 90% white card is represented by the horizontal graph line at excess gain = 10. An object of this reflectivity results in a far limit cutoff of approximately 190 mm (7.5") for the 200 mm (8") cutoff model, for example; thus 190 mm represents the cutoff for this sensor and target. These excess gain curves were generated using a white test card of 90% reflectance. Objects with reflectivity of less than 90% reflect less light back to the sensor, and thus require proportionately more excess gain in order to be sensed with the same reliability as more reflective objects. When sensing an object of very low reflectivity, it may be especially important to sense it at or near the distance of maximum excess gain.
Cutoff Distance
Cutoff Distance
Reflective Background
R1 = Near Detector R2 = Far Detector E = Emitter T30FF R1 R2 E
T30FF
Strong Direct Reflection to R1
Core of Emitted Beam
Reflective Background
Fixed Sensing Field
R1 R2 E
Fixed Sensing Field
Core of Emitted Beam
Strong Direct Reflection Away From Sensor
R1 = Near Detector R2 = Far Detector E = Emitter
Figure 3. Reflective background – problem
Figure 4. Reflective background – solution Cutoff Distance
Cutoff Distance
T30FF
T30FF R1 R2
E, R2, R1
E
Fixed Sensing Field R1 = Near Detector R2 = Far Detector E = Emitter
Reflective Background or Moving Object
Fixed Sensing Field E = Emitter R2 = Far Detector R1 = Near Detector
Reflective Background or Moving Object
A reflective background object in this position or moving across the sensor face in this axis and direction may cause false sensor response.
A reflective background object in this position or moving across the sensor face in this axis will be ignored.
Figure 5. Object beyond cutoff – problem
Figure 6. Object beyond cutoff – solution
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Sensors – ac-Voltage Series Specifications Supply Voltage and Current
20 to 250V ac (50/60 Hz) Average current: 20 mA Peak current: 200 mA @ 20V ac, 500 mA @ 120V ac, 750 mA @ 250V ac
Supply Protection Circuitry
Protected against transient voltages
Output Configuration
SPST solid-state ac switch; three-wire hookup; light operate or dark operate, depending on model Light Operate: Output conducts when sensor sees its own (or the emitter’s) modulated light Dark Operate: Output conducts when the sensor sees dark
Output Rating
3 00 mA maximum (continuous) Fixed-Field models: derate 5 mA/°C above +50° C (+122° F) Inrush capability: 1 amp for 20 milliseconds, non-repetitive OFF-state leakage current: < 100 microamps ON-state saturation voltage: 3V @ 300 mA ac; 2V @ 15 mA ac
Output Protection Circuitry
Protected against false pulse on power-up
Output Response Time
Opposed mode: 16 milliseconds ON, 8 milliseconds OFF Other models: 16 milliseconds ON and OFF NOTE: 100 millisecond delay on power-up; outputs do not conduct during this time.
Repeatability
Opposed mode: 2 milliseconds Other models: 4 milliseconds Repeatability and response are independent of signal strength.
Indicators
Two LEDs (Green and Yellow) Green ON steady: power to sensor is ON Yellow ON steady: sensor sees light Yellow flashing: excess gain marginal (1 to 1.5x) in light condition
Construction
PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
2 m (6.5') attached cable, or 4-pin Micro-style quick-disconnect fitting
Operating Conditions
Temperature: -40° to +70° C (-40° to +158° F) Maximum relative humidity: 90% at 50° C (non-condensing)
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06" acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)
Certifications
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Sensors – ac-Voltage Series Performance Curves
Opposed Mode
100
Opposed Mode
500 mm
20"
250 mm
10"
0
G A I N
E X C E S S G A I N
0 10"
500 mm
20"
750 mm
30" 0
1m (3.3')
10 m (33')
DISTANCE
1000
Polarized Retro††
30"
250 mm
10
1 0.1 m (0.33')
††
T30 Series
750 mm
100 m (330')
45 m (150')
60 m (200')
75 m (250')
T30 Series
150 mm
6"
Polarized Retro
100 mm
Polarized Retro
30 m (100')
DISTANCE
T30 Series
100
15 m (50')
4"
50 mm
2"
0
with BRT-3 Reflector 10
0
with BRT-3 Reflector
50 mm
2"
100 mm
4"
150 mm 1 0.01 m (0.033')
6" 0
0.1 m (0.33')
1m (3.3')
DISTANCE
10 m (33')
1.5 m (5')
3.0 m (10')
4.5 m (15')
6.0 m (20')
7.5 m (25')
DISTANCE
Performance based on use of a model BRT-3 retroreflector (3" diameter). Actual sensing range may be more or less than specified, depending on the efficiency and reflective area of the retroreflector used.
Fixed-Field – 200 mm
T30 Series
Performance based on use of a 90% reflectance white test card.†
Fixed-Field – 400 mm
Opposed
1000
E X C E S S
Excess Gain
Beam Pattern
Fixed-Field – 600 mm
Excess Gain
1000
E X C E S S
T30 Series
Ø 16 mm spot size @ 35 mm focus Ø 20 mm spot size @ 200 mm cutoff
100 Fixed-field mode with 200 mm far limit cutoff
G A I N
†Using
18% gray test card: cutoff distance will be 95% of value shown. †Using 6% black test card: cutoff distance will be 90% of value shown.
10
1 1 mm (0.04")
10 mm (0.4")
1000
E X C E S S
100 mm (4")
DISTANCE
1000 mm (40")
T30 Series
Ø 17 mm spot size @ 35 mm focus Ø 25 mm spot size @ 400 mm cutoff
100 Fixed-field mode with 400 mm far limit cutoff
G A I N
†Using
18% gray test card: cutoff distance will be 90% of value shown. †Using 6% black test card: cutoff distance will be 85% of value shown.
10
1 1 mm (0.04")
10 mm (0.4")
1000
E X C E S S G A I N
100 mm (4")
DISTANCE
1000 mm (40")
T30 Series
Ø 17 mm spot size @ 35 mm focus Ø 30 mm spot size @ 600 mm cutoff
100 Fixed-field mode with 600 mm far limit cutoff
†Using
18% gray test card: cutoff distance will be 85% of value shown. †Using 6% black test card: cutoff distance will be 75% of value shown.
10
1 1 mm (0.04")
10 mm (0.4")
100 mm (4")
DISTANCE
1000 mm (40")
Focus and spot sizes are typical.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Sensors – ac-Voltage Series Dimensions QD Models
Cabled Models ø 40.0 mm (1.57") Jam Nut (Supplied) M30 x 1.5 Thread 45.0 mm (1.77")
ø 15 mm (0.59")
Green LED Power Indicator 51.5 mm (2.03")
Yellow LED Output Indicator 66.5 mm (2.62")
11.5 mm (0.45")
Hookups Cabled Emitters
QD Emitters (4-pin Micro-Style) rd/bk
bn
rd/wh 20-250V ac
bu
No connection
gn
All Other Cabled Models
All Other QD Models (4-pin Micro-Style) rd/bk
bn 20-250V ac
bu bk
20-250V ac
rd
Load
rd/wh rd gn
20-250V ac
Load
No Connection
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] T30 Sensors – ac-Voltage Series
Quick-Disconnect (QD) Cables Style 4-pin Micro-style Straight
Model MQAC-406 MQAC-415 MQAC-430
Length 2 m (6.5') 5 m (15') 9 m (30')
Dimensions
Pinout ø15 mm (0.6")
44 mm max. (1.7")
ø 1/2-20UNF-2B
38 mm max. (1.5")
4-pin Micro-style Right-angle
MQAC-406RA MQAC-415RA MQAC-430RA
2 m (6.5') 5 m (15') 9 m (30')
Green Wire Red Wire Red/White Wire
Red/Black Wire
38 mm max. (1.5")
1/2-20UNF-2B ø 15 mm (0.6")
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 121523
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] EZ-BEAM® "S2" Series Sensors Designed for use on Sensor BUS Networks
Description
Features • Low cost and easy to use; no adjustments are necessary • Sensor selection is simply a matter of choosing a housing style and sensing mode • Models available for opposed (through-beam), polarized retroreflective, and fixed-field diffuse modes • Advanced self-diagnostics with separate alarm output; dual LED system indicates sensor performance • Solid-state outputs for direct connection to a BUS system network junction such as a Banner BUS DEPOT® • 4-pin quick disconnect connector for standard euro-style extension cables • Epoxy-encapsulated circuitry; leakproof IP67 (NEMA 6P) rating for harsh sensing environments • Brackets available for several mounting options
"S2" Series EZ-BEAM sensors are designed to connect directly to a "smart" BUS system network junction, such as the Banner BUS-DEPOT®. S2 Series sensors are internally wired to take advantage of the EZ-BEAM's marginal signal ALARM output. The ALARM output is normally open (N.O.) and conducts whenever the sensor's excess gain drops to between 1X and 1.5X in the light condition. The sensing signal output is also normally open, which means that the output conducts when light is sensed (i.e. - light operate). In order to take advantage of the second ALARM output, S2 sensors require the use of BUS DEPOT junctions which offer two channels per input. Both sensor outputs are PNP (current sourcing) for direct connection to a BUS network junction using standard 4-pin euro-style extension cables. S2 Series sensors offer all of the features and powerful sensing performance that EZBEAMs offer. The innovative dual-indicator system takes the guesswork out of sensor performance monitoring. Housings are tightly sealed and the sensor circuitry is epoxy-encapsulated for reliable duty in wet or oily sensing environments. Models are available for opposed (through-beam), polarized retroreflective and fixed-field diffuse sensing (see chart on page 2, for available ranges). As the chart on page 2 shows, there are three basic housing styles. The "S" style is a threaded barrel which is available in 18 mm or 30 mm diameters. The "Q" style offers either 25 mm or 40 mm right-angle rectangular housings. Finally, the "T" style is a patented† right-angle design available with either an 18 mm or 30 mm threaded lens. The "T" style combines the mounting ease of a barrel sensor with the low-profile advantage of a right-angle design. Several mounting options are offered, including angled brackets and split-clamp brackets. S2 series sensors may also be simply mounted through suitable clearance holes. See page 7 for more information. †
U.S. Patent #5087838
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] S2 Series Available Sensing Modes and Ranges Family
Sensor Package
Opposed
Retro
18 mm barrel
20 m (60 ft)
2 m (79 in)
Fixed-field
S18 50 mm (2 in) 100 mm (4 in)
S30 200 mm (8 in) 30 mm barrel
60 m (200 ft)
6 m (20 ft) 400 mm (16 in)
Q25 50 mm (2 in) 25 mm rectangular
20 m (60 ft)
2 m (79 in) 100 mm (4 in)
Q40 200 mm (8 in) 40 mm rectangular
60 m (200 ft)
6 m (20 ft) 400 mm (16 in)
T18 50 mm (2 in) 18 mm right-angle
20 m (60 ft)
2 m (79 in) 100 mm (4 in)
T30 200 mm (8 in) 30 mm right-angle
60 m (200 ft)
6 m (20 ft) 400 mm (16 in)
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] S2 Series Opposed Mode Emitter (E) and Receiver (R) Models
Range
Cable
Supply Voltage
Output Type
S186EQ S18S2P6RQ Q256EQ Q25S2P6RQ
Excess Gain
Effective Beam: 13 mm (0.5")
1000
20 m (66 ft)
4-pin Euro QD
10-30V dc
PNP
E X C E S S G A I N
S18, Q25 and T18 Series
S18, Q25 and T18 Series
1500 mm
60 in
Opposed Mode
Opposed Mode
100
1000 mm
40 in
500 mm
20 in
0 10
0
500 mm
20 in
1000 mm
40 in
1500 mm 1 .1 m .33 ft
T186EQ T18S2P6RQ
60 in 0
1m 3.3 ft
10 m 33 ft
100 m 330 ft
5m 16 ft
10 m 32 ft
15 m 48 ft
20 m 64 ft
25 m 80 ft
DISTANCE
DISTANCE
Effective Beam: 23 mm (0.9")
S306EQ S30S2P6RQ Q406EQ Q40S2P6RQ
Beam Pattern
1000
60 m (200 ft)
4-pin Euro QD
10-30V dc
PNP
E X C E S S G A I N
T306EQ T30S2P6RQ
100
S30, Q40 and T30 Series
S30, Q40 and T30 Series
750 mm
Opposed Mode
60 in
Opposed Mode
500 mm
40 in
250 mm
20 in
0 10
0
250 mm
20 in
500 mm
40 in
750 mm 1 .1 m .33 ft
1m 3.3 ft
10 m 33 ft
60 in 0
100 m 330 ft
15 m 50 ft
30 m 100 ft
DISTANCE
45 m 150 ft
60 m 200 ft
75 m 250 ft
DISTANCE
Retroreflective Mode Models
Range
Cable
Supply Voltage
Output Type
Beam Pattern
1000
S18S2P6LPQ
Q25S2P6LPQ
Excess Gain
2m (79 in)
4-pin Euro QD
10-30V dc
PNP
S18, Q25 and T18 Series
E X C E S S
S18, Q25 and T18 Series
150 mm
6 in
Polarized Retro 100 mm
Polarized Retro
100
4 in
50 mm
2 in
0 with BRT-3 Reflector
G A I N
10
1 .01 m .033 ft
T18S2P6LPQ
50 mm
2 in
100 mm
4 in
150 mm
6 in 0
.1 m .33 ft
1m 3.3 ft
0
with BRT-3 Reflector
.5 m 1.6 ft
1.0 m 3.2 ft
10 m 33 ft
1.5 m 4.8 ft
2.0 m 6.4 ft
2.5 m 8.0 ft
DISTANCE
DISTANCE
1000
S30S2P6LPQ
Q40S2P6LPQ
6m (20 ft)
T30S2P6LPQ
4-pin Euro QD
10-30V dc
PNP
E X C E S S G A I N
S30, Q40 and T30 Series
6 in
Polarized Retro 100
100 mm
4 in
50 mm
10
1 .01 m .033 ft
2 in
0
with BRT-3 Reflector
1m 3.3 ft
10 m 33 ft
0
with BRT-3 Reflector
50 mm
2 in
100 mm
4 in
150 mm
6 in 0
.1 m .33 ft
DISTANCE
Banner Engineering Corporation Clearwater Tech - Phone:
S30, Q40 and T30 Series
150 mm
Polarized Retro
1.5 m 5 ft
3.0 m 10 ft
4.5 m 15 ft
6.0 m 20 ft
7.5 m 25 ft
DISTANCE
800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] 3
S2 Series Fixed-field Mode Models
Range
Cable
Supply Voltage
Output Type
Excess Gain Performance based on 90% reflectance white test card
50 mm far limit cutoff
1000
S18, Q25 and T18 Series
E X C E S S
S18S2P6FF50Q
Q25S2P6FF50Q
50 mm (2 in)
4-Pin Euro QD
10-30V dc
PNP
Fixed-field mode with 50 mm far limit cutoff
100
10
G A I N
1 .1 mm .004 in
T18S2P6FF50Q
1 mm .04 in
10 mm .4 in
100 mm 4 in
DISTANCE
100 mm far limit cutoff
1000
S18, Q25 and T18 Series
E X C E S S
S18S2P6FF100Q
Q25S2P6FF100Q
100 mm (4 in)
4-Pin Euro QD
10-30V dc
PNP
Fixed-field mode with 100 mm far limit cutoff
100
G A I N
10
1 .1 mm .004 in
T18S2P6FF100Q
1 mm .04 in
10 mm .4 in
100 mm 4 in
DISTANCE
200 mm far limit cutoff
1000
S30, Q40 and T30 Series
E X C E S S
S30S2P6FF200Q
Q40S2P6FF200Q
200 mm (8 in)
4-Pin Euro QD
10-30V dc
PNP
G A I N
100 Fixed-field mode with 200 mm far limit cutoff 10
1 1 mm .04 in
T30S2P6FF200Q
10 mm .4 in
100 mm 4 in
1000 mm 40 in
DISTANCE
400 mm far limit cutoff
1000
S30, Q40 and T30 Series
E X C E S S
S30S2P6FF400Q
Q40S2P6FF400Q
T30S2P6FF400Q
400 mm (16 in)
4-Pin Euro QD
10-30V dc
PNP
G A I N
100 Fixed-field mode with 400 mm far limit cutoff 10
1 1 mm .04 in
10 mm .4 in
100 mm 4 in
1000 mm 40 in
DISTANCE
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email:
[email protected] S2 Series Product Specifications Supply Voltage and Current Opposed Mode Emitter Opposed Mode Receiver Polarized Retro Fixed-field
10 to 30V dc (10% maximum ripple); Supply current (exclusive of load current): 25 mA 20 mA 30 mA 35 mA
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
Sensing Output: PNP (current sourcing), light operated
Alarm Output: PNP (current sourcing), normally open and conducts whenever the sensor's excess gain drops to between 1X and 1.5X in the light condition
Output Rating
150 mA maximum (each); the total load may not exceed 150 mA; Off-state leakage current