cable mounted plugs panel front mounted panel rear mounted

Report 10 Downloads 61 Views
Body style selection

CORE SERIES

FISCHER CORE SERIES BRASS – GENERAL INFORMATION

PLUGS CABLE MOUNTED BODY STYLES S SC SOV SA SV SS Locking system Sealing Design

BODY STYLES Locking system Sealing Design

Push-pull IP50 / IP68 Standard

Quick-release IP50 / IP68 Standard

Non-locking IP50 / IP68 Standard

Locking system Sealing Design

B  2

Push-pull Push-pull IP50 / IP68 IP50 / IP68 Tamperproof Short/Overmolding

SSC WSO Quick-release Push-pull IP50 / IP68 IP50 / IP68 Short/Overmolding Right-angle

PANEL FRONT MOUNTED BODY STYLES

Push-pull IP50 / IP68 Lanyard

PANEL REAR MOUNTED SF

SFU SFE

BODY STYLES

Non-locking Non-locking IP50 IP68 Hermetic Front-projecting Front-projecting

SFPU SFPE

Locking system Non-locking Sealing IP68 Hermetic Design Front-projecting

Technical Specifications www.avtic.com [email protected]

tel. +31 (0)40 2088088 fax +31 (0)40 2088099

www.givatec.com [email protected]

tel. +32 (0)16 400500 fax +32 (0)16 401010

RECEPTACLES

RECEPTACLES & FEEDTHROUGH

CABLE MOUNTED

SPECIAL DESIGN

BODY STYLES Sealing Design

K KE

KS KSE

IP50 IP68 IP50 IP68 Standard Short/Overmolding

BODY STYLES Sealing Design

DG DGP IP50 IP50 Completely threaded Solder/Crimp PCB

CORE SERIES

GENERAL INFORMATION – FISCHER CORE SERIES BRASS

Body style selection

WDE Hermetic Bulkhead feedthrough

PANEL FRONT MOUNTED BODY STYLES Sealing Design

D IP50 Rear-projecting

DB

DEU DEE

DBEU DBEE

IP50 IP68 Hermetic IP68 Hermetic Front-projecting Rear-projecting Front-projecting

DK

DKE

IP50 Cable mounted

IP68 Cable mounted

PANEL REAR MOUNTED BODY STYLES Sealing Design

DBP

DBPC

IP50 Rear-projecting

IP50 Right-angle PCB

DBPU DBPE

DBPLU DBPLE

IP68 Hermetic Rear-projecting

IP68 Hermetic Front-projecting

DKBE IP68 Cable mounted

B  3 www.avtic.com [email protected]

tel. +31 (0)40 2088088 fax +31 (0)40 2088099

www.givatec.com [email protected]

tel. +32 (0)16 400500 fax +32 (0)16 401010

Size selection

CORE SERIES

FISCHER CORE SERIES BRASS – GENERAL INFORMATION

Multipole low voltage

CONNECTOR SIZE VERSUS CABLE DIAMETER

Series

Min Cable ø

Max Cable ø

Nbr of Contacts

102

1.5

4.7 2) (4.3)

2-9

103

1.7

6.7 2) (6.2)

2-12

1031

2.2

7.2 2) (6.7)

10-19

104

2.9

8.7

2-27

105

1.5

10.7

2-27

106

4.2

19.2

3-24

107

5.7

22.7

4-55

Pictures represent standard S plug, but values can be extended to all cable mounted plugs, except for SS/SSC body styles. 1)

For max cable ø, values in parenthesis are valid for sealed connectors (IP68). 2)

mm B  6

100

50

0

For more information see Multipole low voltage section, page B 1-39

Technical Specifications www.avtic.com [email protected]

tel. +31 (0)40 2088088 fax +31 (0)40 2088099

www.givatec.com [email protected]

tel. +32 (0)16 400500 fax +32 (0)16 401010

CORE SERIES

GENERAL INFORMATION – FISCHER CORE SERIES BRASS

Size selection

LV = Low Voltage HV = High Voltage Multipole high voltage Min cable ø

Max cable ø

Nbr of contacts

Coax low voltage

Triax

Coax high voltage

Mixed high voltage

Min cable ø

Max cable ø

Min cable ø

Max cable ø

Min cable ø

Max cable ø

1.5

4.7 (4.3)

1.5

4.7 (4.3)

1.5

4.7 (4.3)

1.7

6.7 (6.2)

1.7

6.7 (6.2)

1.7

6.7 (6.2)

Min cable ø

Max cable ø

2.9

8.7

4 HV

2.9

8.7

2.9

8.7

2.9

8.7

3.2

10.7

3-5 HV

3.2

10.7

3.2

10.7

3.2

10.7

4.2

19.2

6-7 HV

4.2

19.2

5.7

22.7

7 HV

For more information see Multipole high voltage section, page B 2-10

5.7

For more information see Coax low voltage section, page B 3-22

Nbr of contacts

1 LV 2 HV

1-10 LV 1-4 HV

Mixed coax Min cable ø

Max cable ø

2.9

8.7

3.2

10.7

Nbr of contacts

1 Coax 1-4 LV

1 Coax 1-9 LV

6 LV 2 HV

22.7

For more information see Coax high voltage section, page B 4-7

For more information see Triax section, page B 5-17

For more information see Mixed high voltage section, page B 6-7

For more information see Mixed coax section, page B 7-15

B  7 www.avtic.com [email protected]

tel. +31 (0)40 2088088 fax +31 (0)40 2088099

www.givatec.com [email protected]

tel. +32 (0)16 400500 fax +32 (0)16 401010

Electrical & contact configurations

BRASS MULTIPOLE LOW VOLTAGE

FISCHER CORE SERIES BRASS – MULTIPOLE LOW VOLTAGE

102 SERIES

Contact to body

Contact to contact

Contact to body

Contact to contact

● 7)



PEEK

0.9

max ø0.79mm AWG21 [1] AWG22 [7/30]

max ø0.83mm min ø0.48mm AWG22-26

1.3

1.7

1.8

2.4

250

9.2



PEEK

0.9

max ø0.79mm AWG21 [1] AWG22 [7/30]



1.3

1.3

1.8

1.6

250

8.2

[A]

Crimp contacts

DC

AC r.m.s

3)

PCB

Wire size 2)

Current rating

Crimp 6)

Rated voltage 4) r.m.s [V]

Contact ø [mm]

Solder contacts 1)

Contact types

Solder

Test voltage 5) [kV] in mated position

Insulating material

Number of contacts

Pin layout

Reference

● = Standard ❍ = Option

102 A 051 Z

2



102 A 052 Z

3



102 A 053 Z

4







PEEK

0.7

max ø0.79mm AWG21 [1] AWG22 [7/30]

max ø0.62mm min ø0.38mm AWG24-28

1.2

1.2

1.7

1.8

200

5.5

102 A 054 Z

5







PEEK

0.7

max ø0.79mm AWG21 [1] AWG22 [7/30]

max ø0.62mm min ø0.38mm AWG24-28

0.8

1.0

1.3

1.8

160

5.2

102 A 056 Z

7







PEEK

0.5

max ø0.43mm AWG26 [1] AWG28 [19/40]

max ø0.43mm min ø0.20mm AWG28-32

0.8

1.0

1.3

1.8

160

4.0

102 A 059 Z

9





PEEK

0.5

max ø0.43mm AWG26 [1] AWG28 [19/40]



0.8

1.1

1.2

1.8

160

3.1

1)

Stranding values are in brackets.

2)

For a given AWG, the diameter of some stranded conductor designs could exceptionally be larger than the hole diameter of the barrel. Testing may be required.

3)

Recommended max. operating current per contact at 40°C temperature rise measured according to IEC 60512-5-2-5b.

4)

Recommended operating voltage at sea level measured according to IEC 60664-1.

5)

Measured with S plug and D receptacle. Please contact us for ratings for WSO right-angle plugs and WDE bulkhead feedthroughs.

6)

Plug with crimp contacts must be used with unshielded clamps only. See page B 1-41.

7)

Only available for A polarity plugs.

B 1 - 27 www.avtic.com [email protected]

tel. +31 (0)40 2088088 fax +31 (0)40 2088099

www.givatec.com [email protected]

tel. +32 (0)16 400500 fax +32 (0)16 401010

Cable clamp sets

BRASS MULTIPOLE LOW VOLTAGE

FISCHER CORE SERIES BRASS – MULTIPOLE LOW VOLTAGE

102 SERIES S SHIELDED Sleeve

Cable dia. range

Clamp

Ø

Shielded cable clamp with sleeve and clamp.

Collet Ø

Cable clamp set 1)

1.5 - 2.1

2.1

E32 102.1/2.1 + A

2.1 - 2.6

2.6

E32 102.1/2.6 + A

2.6 - 3.1

3.1

E32 102.1/3.1 + A

3.1 - 3.6

3.6

E32 102.1/3.6 + A

3.6 - 4.1

4.1

E32 102.1/4.1 + A

4.1 - 4.3

4.3

E32 102.1/4.3 + A

4.3 - 4.7

4.7

E3 102.248 + A

Collet Ø

Cable clamp set1)

2.0

E3 102.5/2.0

U UNSHIELDED Cable dia. range

Clamp

Unshielded, one-piece cable clamp.

1.4 - 2.0

E ENVIRONMENTAL Washer Sleeve

1)

2.7

E3 102.5/2.7

3.5

E3 102.5/3.5

3.5 - 4.2

4.2

E3 102.5/4.2

4.2 - 4.7

4.7

E3 102.5/4.7

Collet Ø

Cable clamp set1)

1.5 - 2.1

2.1

E31 102.2/2.1 + B

2.1 - 2.6

2.6

E31 102.2/2.6 + B

2.6 - 3.1

3.1

E31 102.2/3.1 + B

3.1 - 3.6

3.6

E31 102.2/3.6 + B

3.6 - 4.1

4.1

E31 102.2/4.1 + B

4.1 - 4.3

4.3

E31 102.2/4.3 + B

Cable dia. range

Seal Clamp

Ø

Environmentally sealed clamp for use with shielded or unshielded cables.

2.0 - 2.7 2.7 - 3.5

For ordering information see page B 1-40.

B 1 - 41 www.avtic.com [email protected]

tel. +31 (0)40 2088088 fax +31 (0)40 2088099

www.givatec.com [email protected]