Body style selection
CORE SERIES
FISCHER CORE SERIES BRASS – GENERAL INFORMATION
PLUGS CABLE MOUNTED BODY STYLES S SC SOV SA SV SS Locking system Sealing Design
BODY STYLES Locking system Sealing Design
Push-pull IP50 / IP68 Standard
Quick-release IP50 / IP68 Standard
Non-locking IP50 / IP68 Standard
Locking system Sealing Design
B 2
Push-pull Push-pull IP50 / IP68 IP50 / IP68 Tamperproof Short/Overmolding
SSC WSO Quick-release Push-pull IP50 / IP68 IP50 / IP68 Short/Overmolding Right-angle
PANEL FRONT MOUNTED BODY STYLES
Push-pull IP50 / IP68 Lanyard
PANEL REAR MOUNTED SF
SFU SFE
BODY STYLES
Non-locking Non-locking IP50 IP68 Hermetic Front-projecting Front-projecting
SFPU SFPE
Locking system Non-locking Sealing IP68 Hermetic Design Front-projecting
Technical Specifications www.avtic.com
[email protected] tel. +31 (0)40 2088088 fax +31 (0)40 2088099
www.givatec.com
[email protected] tel. +32 (0)16 400500 fax +32 (0)16 401010
RECEPTACLES
RECEPTACLES & FEEDTHROUGH
CABLE MOUNTED
SPECIAL DESIGN
BODY STYLES Sealing Design
K KE
KS KSE
IP50 IP68 IP50 IP68 Standard Short/Overmolding
BODY STYLES Sealing Design
DG DGP IP50 IP50 Completely threaded Solder/Crimp PCB
CORE SERIES
GENERAL INFORMATION – FISCHER CORE SERIES BRASS
Body style selection
WDE Hermetic Bulkhead feedthrough
PANEL FRONT MOUNTED BODY STYLES Sealing Design
D IP50 Rear-projecting
DB
DEU DEE
DBEU DBEE
IP50 IP68 Hermetic IP68 Hermetic Front-projecting Rear-projecting Front-projecting
DK
DKE
IP50 Cable mounted
IP68 Cable mounted
PANEL REAR MOUNTED BODY STYLES Sealing Design
DBP
DBPC
IP50 Rear-projecting
IP50 Right-angle PCB
DBPU DBPE
DBPLU DBPLE
IP68 Hermetic Rear-projecting
IP68 Hermetic Front-projecting
DKBE IP68 Cable mounted
B 3 www.avtic.com
[email protected] tel. +31 (0)40 2088088 fax +31 (0)40 2088099
www.givatec.com
[email protected] tel. +32 (0)16 400500 fax +32 (0)16 401010
Size selection
CORE SERIES
FISCHER CORE SERIES BRASS – GENERAL INFORMATION
Multipole low voltage
CONNECTOR SIZE VERSUS CABLE DIAMETER
Series
Min Cable ø
Max Cable ø
Nbr of Contacts
102
1.5
4.7 2) (4.3)
2-9
103
1.7
6.7 2) (6.2)
2-12
1031
2.2
7.2 2) (6.7)
10-19
104
2.9
8.7
2-27
105
1.5
10.7
2-27
106
4.2
19.2
3-24
107
5.7
22.7
4-55
Pictures represent standard S plug, but values can be extended to all cable mounted plugs, except for SS/SSC body styles. 1)
For max cable ø, values in parenthesis are valid for sealed connectors (IP68). 2)
mm B 6
100
50
0
For more information see Multipole low voltage section, page B 1-39
Technical Specifications www.avtic.com
[email protected] tel. +31 (0)40 2088088 fax +31 (0)40 2088099
www.givatec.com
[email protected] tel. +32 (0)16 400500 fax +32 (0)16 401010
CORE SERIES
GENERAL INFORMATION – FISCHER CORE SERIES BRASS
Size selection
LV = Low Voltage HV = High Voltage Multipole high voltage Min cable ø
Max cable ø
Nbr of contacts
Coax low voltage
Triax
Coax high voltage
Mixed high voltage
Min cable ø
Max cable ø
Min cable ø
Max cable ø
Min cable ø
Max cable ø
1.5
4.7 (4.3)
1.5
4.7 (4.3)
1.5
4.7 (4.3)
1.7
6.7 (6.2)
1.7
6.7 (6.2)
1.7
6.7 (6.2)
Min cable ø
Max cable ø
2.9
8.7
4 HV
2.9
8.7
2.9
8.7
2.9
8.7
3.2
10.7
3-5 HV
3.2
10.7
3.2
10.7
3.2
10.7
4.2
19.2
6-7 HV
4.2
19.2
5.7
22.7
7 HV
For more information see Multipole high voltage section, page B 2-10
5.7
For more information see Coax low voltage section, page B 3-22
Nbr of contacts
1 LV 2 HV
1-10 LV 1-4 HV
Mixed coax Min cable ø
Max cable ø
2.9
8.7
3.2
10.7
Nbr of contacts
1 Coax 1-4 LV
1 Coax 1-9 LV
6 LV 2 HV
22.7
For more information see Coax high voltage section, page B 4-7
For more information see Triax section, page B 5-17
For more information see Mixed high voltage section, page B 6-7
For more information see Mixed coax section, page B 7-15
B 7 www.avtic.com
[email protected] tel. +31 (0)40 2088088 fax +31 (0)40 2088099
www.givatec.com
[email protected] tel. +32 (0)16 400500 fax +32 (0)16 401010
Electrical & contact configurations
BRASS MULTIPOLE LOW VOLTAGE
FISCHER CORE SERIES BRASS – MULTIPOLE LOW VOLTAGE
102 SERIES
Contact to body
Contact to contact
Contact to body
Contact to contact
● 7)
●
PEEK
0.9
max ø0.79mm AWG21 [1] AWG22 [7/30]
max ø0.83mm min ø0.48mm AWG22-26
1.3
1.7
1.8
2.4
250
9.2
●
PEEK
0.9
max ø0.79mm AWG21 [1] AWG22 [7/30]
–
1.3
1.3
1.8
1.6
250
8.2
[A]
Crimp contacts
DC
AC r.m.s
3)
PCB
Wire size 2)
Current rating
Crimp 6)
Rated voltage 4) r.m.s [V]
Contact ø [mm]
Solder contacts 1)
Contact types
Solder
Test voltage 5) [kV] in mated position
Insulating material
Number of contacts
Pin layout
Reference
● = Standard ❍ = Option
102 A 051 Z
2
●
102 A 052 Z
3
●
102 A 053 Z
4
●
●
●
PEEK
0.7
max ø0.79mm AWG21 [1] AWG22 [7/30]
max ø0.62mm min ø0.38mm AWG24-28
1.2
1.2
1.7
1.8
200
5.5
102 A 054 Z
5
●
●
●
PEEK
0.7
max ø0.79mm AWG21 [1] AWG22 [7/30]
max ø0.62mm min ø0.38mm AWG24-28
0.8
1.0
1.3
1.8
160
5.2
102 A 056 Z
7
●
●
●
PEEK
0.5
max ø0.43mm AWG26 [1] AWG28 [19/40]
max ø0.43mm min ø0.20mm AWG28-32
0.8
1.0
1.3
1.8
160
4.0
102 A 059 Z
9
●
●
PEEK
0.5
max ø0.43mm AWG26 [1] AWG28 [19/40]
–
0.8
1.1
1.2
1.8
160
3.1
1)
Stranding values are in brackets.
2)
For a given AWG, the diameter of some stranded conductor designs could exceptionally be larger than the hole diameter of the barrel. Testing may be required.
3)
Recommended max. operating current per contact at 40°C temperature rise measured according to IEC 60512-5-2-5b.
4)
Recommended operating voltage at sea level measured according to IEC 60664-1.
5)
Measured with S plug and D receptacle. Please contact us for ratings for WSO right-angle plugs and WDE bulkhead feedthroughs.
6)
Plug with crimp contacts must be used with unshielded clamps only. See page B 1-41.
7)
Only available for A polarity plugs.
B 1 - 27 www.avtic.com
[email protected] tel. +31 (0)40 2088088 fax +31 (0)40 2088099
www.givatec.com
[email protected] tel. +32 (0)16 400500 fax +32 (0)16 401010
Cable clamp sets
BRASS MULTIPOLE LOW VOLTAGE
FISCHER CORE SERIES BRASS – MULTIPOLE LOW VOLTAGE
102 SERIES S SHIELDED Sleeve
Cable dia. range
Clamp
Ø
Shielded cable clamp with sleeve and clamp.
Collet Ø
Cable clamp set 1)
1.5 - 2.1
2.1
E32 102.1/2.1 + A
2.1 - 2.6
2.6
E32 102.1/2.6 + A
2.6 - 3.1
3.1
E32 102.1/3.1 + A
3.1 - 3.6
3.6
E32 102.1/3.6 + A
3.6 - 4.1
4.1
E32 102.1/4.1 + A
4.1 - 4.3
4.3
E32 102.1/4.3 + A
4.3 - 4.7
4.7
E3 102.248 + A
Collet Ø
Cable clamp set1)
2.0
E3 102.5/2.0
U UNSHIELDED Cable dia. range
Clamp
Unshielded, one-piece cable clamp.
1.4 - 2.0
E ENVIRONMENTAL Washer Sleeve
1)
2.7
E3 102.5/2.7
3.5
E3 102.5/3.5
3.5 - 4.2
4.2
E3 102.5/4.2
4.2 - 4.7
4.7
E3 102.5/4.7
Collet Ø
Cable clamp set1)
1.5 - 2.1
2.1
E31 102.2/2.1 + B
2.1 - 2.6
2.6
E31 102.2/2.6 + B
2.6 - 3.1
3.1
E31 102.2/3.1 + B
3.1 - 3.6
3.6
E31 102.2/3.6 + B
3.6 - 4.1
4.1
E31 102.2/4.1 + B
4.1 - 4.3
4.3
E31 102.2/4.3 + B
Cable dia. range
Seal Clamp
Ø
Environmentally sealed clamp for use with shielded or unshielded cables.
2.0 - 2.7 2.7 - 3.5
For ordering information see page B 1-40.
B 1 - 41 www.avtic.com
[email protected] tel. +31 (0)40 2088088 fax +31 (0)40 2088099
www.givatec.com