city of takoma park, maryland

Report 6 Downloads 168 Views
MONTGOMERY COUNTY, MARYLAND

DEPARTMENT OF PUBLIC WORKS

CITY OF TAKOMA PARK

KIRKLYNN AND KENEWICK BIORETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM ( OPTION-2)

PORJECT NAME:

NTS

DATE APPROVED:

PORJECT TITLE:

SCALE:

APPROVED BY:

TITLE AND GENERAL NOTES

A. Khalilian, P.E.

DRAWN BY:

BIORETENTION WITH OVERFLOW DRAINAGE SYSTEM

Sept 18,2017

A. Khalilian, P.E. Z. Mathewos

DESIGNED BY: PORJECT TYPE:

SW-1A

DRAWING NUMBER

CITY OF TAKOMA PARK, MARYLAND No. 1 OF 11

SHEET

MONTGOMERY COUNTY, MARYLAND

DEPARTMENT OF PUBLIC WORKS

CITY OF TAKOMA PARK

KIRKLYNN AND KENEWICK BIORETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM ( OPTION-2)

PORJECT NAME:

SCALE:

NTS

DATE APPROVED:

PORJECT TITLE:

TITLE AND GENERAL NOTES

A. Khalilian, P.E.

APPROVED BY:

Mar. 23,2017

A. Khalilian, P.E. Z. Mathewos DRAWN BY:

DESIGNED BY:

PORJECT TYPE:

BIORETENTION WITH OVERFLOW DRAINAGE SYSTEM

SW-1B

DRAWING NUMBER

No. 2 OF 11

SHEET

N

B

A

D

D

A

B

D

NEW 48" MH

D

1 SW-2

DRAINAGE AREA PLAN-1 1" = 200'-0"

TABLE-1

SUMMARY OF DRAINAGE AREA PER INDIVIDUAL STURUCTUE/FACILITY DA#1

DRAINAGE AREA (ACRES) DA PER IMP 0.83 1.93 1.10

DA#2

1.51

0.23

1.74

SD-2 / A-5 INLET

DA#3

0.98

0.52

1.56

SD-3 / A-5 INLET

DA#4

0.52

0.03

0.55

SD-4 / DROP INLET

DA#5

0.05

0.02

0.07

SD-5 / A-4 INLET

DA#6

0.36

0.00

0.36

SD-6 / A-5 INLET

DA#7

3.56

0.50

4.06

SD-7 / A-5 INLET

DA#8

0.71

0.09

0.80

SD-8 / A-5 INLET

AD #

PORJECT NAME:

KIRKLYNN AND KENEWICK BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM (OPTION-2) CITY OF TAKOMA PARK DEPARTMENT OF PUBLIC WORKS

MONTGOMERY COUNTY, MARYLAND

STRUCTURE # / FACILITY BIORETENTION FACILITY

PORJECT TYPE:

DESIGNED BY:

BIO RETENTION FACILITY AND OVERFLOW DRAINAGE SYSTEM DRAWN BY:

APPROVED BY: PORJECT TITLE:

DRAINAGE AREA PLAN-1

REMARKS

A. Khalilian, P.E. Z. Mathewos

A. Khalilian, P.E.

DATE APPROVED: Feb. 27, 2017 SCALE:

DRAWING NUMBER

1" = 200'-0"

SW-2

SHEET

No. 3 OF 11

N

B

X

1 SW-8

A

X

X D

D

A 1 SW-7

B

D

NEW 48" MH

D

1 SW-3

DRAINAGE AREA PLAN-2 1" = 100'-0" PORJECT NAME:

KIRKLYNN AND KENEWICK BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM (OPTION-2) CITY OF TAKOMA PARK DEPARTMENT OF PUBLIC WORKS MONTGOMERY COUNTY, MARYLAND

PORJECT TYPE:

DESIGNED BY:

BIO RETENTION FACILITY AND OVERFLOW DRAINAGE SYSTEM DRAWN BY:

APPROVED BY: PORJECT TITLE:

DRAINAGE AREA PLAN-1

A. Khalilian, P.E. Z. Mathewos

A. Khalilian, P.E.

DATE APPROVED: Feb. 27, 2017 SCALE:

DRAWING NUMBER

1" = 100'-0"

SW-3

SHEET

No. 4 OF 11

1 SW-4 D

S

S S

S S

S

1" = 40'-0" P-1, NE W S

91.5

S

201.5' @ 1.3 % S

B P-2

A P-2 40.6 ' .0% @2

6' @ 2.0%

D

S

NEW 48" MH

D

BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM PLAN A. Khalilian, P.E.

Z. Mathewos

SCALE:

1" = 40'-0"

DATE APPROVED: Sept 18, 2017

B

MONTGOMERY COUNTY, MARYLAND

S

78.1'' @ 5.4 %

A. Khalilian, P.E.

1 SW-7

EXISTING BIO RETENTION FACILITY AND NEW OVERFLOW DRAINAGE SYSTEM PLAN

S

P-6

CITY OF TAKOMA PARK DEPARTMENT OF PUBLIC WORKS

A

PORJECT TITLE:

2.0%

APPROVED BY:

DPE

DESIGNED BY:

'@

KIRKLYNN AND KENEWICK BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM (OPTION-2)

X

PORJECT TYPE:

32.0

D

BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM DRAWN BY:

P-11 , NE WH

PORJECT NAME:

4

S

P-

S 1 SW-8

P-5

B

P-3

A

P-7

P-8

P-9

X X

SW-4

DRAWING NUMBER

No. 5 OF 11

SHEET

No. 6 OF 11

SHEET

1" = 10'-0"

SW-5 MONTGOMERY COUNTY, MARYLAND

CITY OF TAKOMA PARK DEPARTMENT OF PUBLIC WORKS

BIO RETENTION FACILITY EXISTING CONDITIONS AND DEMOLITION PLAN

SCALE:

DATE APPROVED: Feb. 27, 2017

PORJECT TITLE:

APPROVED BY:

A. Khalilian, P.E.

DRAWING NUMBER A. Khalilian, P.E. PORJECT TYPE:

Z. Mathewos

KIRKLYNN AND KENEWICK BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM (OPTION-2)

BIORETENTION FACILITY EXISTING CONDITIONS AND DEMOLITION PLAN 1 SW-5 1" = 10'-0"

PORJECT NAME:

* REMOVE EX PVC PIPE RE USE IF IN GOOD CONDITION * SAVE EX RIVER JACK ROCK AND RE USE LATER * REMOVE AND DISPOSE OF PLANTS AND BIO-SOIL * REMOVE EX PERFORATED PVC W/ CLEAN OUT AND SAVE FOR LATER USE IF IN GOOD CONDITION * SAVE EX WASHED STONE (M-43) FOR RE-USE AND AVOID CONTAMINATION.

DESIGNED BY:

APPROX. LOCATION OF GAS LINE; (CONTACTOR IS RESPONSIBLE TO LOCATE EXACT LOCATION BEFORE EXCAVATION)

BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM DRAWN BY:

EX CONC. CHANNEL AND CURB INLET TO REMAIN

EX STONE PAVER TO REMAIN REMOVE EX CURB OPENING AND REPLACE W/ NEW CURB TO MATCH EXISTING LIMIT OF EXCAVATION NECESSARY TO INSTALL A-5 INLET EX STONE PAVER TO BE RESTORED AFTER INSTALLATION OF NEW INLET REMOVE EX CONCRETE CHANNEL AND REPLACE W/ STONE PAVER TO MATCH EX PAVER

1" = 10'-0"

NEW SITECAST RISER STR

S SOLID, SCH 40, 6" S OBSERVATION WELL

S NEW SCHEDUL 40, 6" S PERFORATED PVC CONN. TO INLET

BIORETENTION FACILITY WITH INLET STRUCTURE PLAN S

S

S GA MONTGOMERY COUNTY, MARYLAND

B GAS

CITY OF TAKOMA PARK DEPARTMENT OF PUBLIC WORKS

1 SW7 DESIGNED BY:

BIO RETENTION FACILITY WITH INLET STRUCTURE PLAN

PORJECT TITLE:

A. Khalilian, P.E.

SCALE:

1" = 10'-0"

DATE APPROVED: Feb. 27, 2017

APPROVED BY:

Z. Mathewos

A. Khalilian, P.E.

A BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM DRAWN BY:

RESTORE STONE PAVER

KIRKLYNN AND KENEWICK BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM (OPTION-2)

SOLID SCHEDULE 40, 6" DIA. PVC CLEAN OUT

PORJECT TYPE:

NEW MODIFIED DROP INLET W/ INCLINED GRATE (STR#2)

PORJECT NAME:

S GA

1 SW-6

B 1 SW-8

SOLID SCHEDULE 40, 6" DIA. PVC CLEAN OUT

A

NEW 12" HDPE

SW-6

DRAWING NUMBER

No. 7 OF 11

SHEET

No. 8 OF 11

SHEET SCHE 40, 6" PVC OBSERVATION WELL

12" BIO-SOIL

EL 202.30' TOP OF CURB

4" # 8 STONE

12" # 57 STONE

EL 200.33' TOP OF RISER

SCHEDULE 40 PERFORATED PVC

SW-7

DRAWING NUMBER

EL 201.33' INV. INTO POND

3" MULCH

EL 199.58' TOP OF POND EL 200.33' TOP OF PONDING

RESTORE EX STONE PAVER

1.00'

PORJECT TYPE:

2" 2" 6"

BIO-SOIL

2% MIN. SL

2'-6"

3.00'

SCHEDULE 40 PERFORATED PVC # 57 STONE

3 SW-7

DETAIL AT INFLOW CURB OPENING 1" = 1'-6"

PORJECT NAME:

#8 STONE

DETAIL AT BIORETENTION OUTFALL 2 SW-7 1" = 1'-6"

AS INDICATED SCALE:

OPE

MONTGOMERY COUNTY, MARYLAND

RESTORE STONE VAVER

CROSS SECTIONS AND DETAILS OF BIORETENTION FACILITY

#4 BARS @ 12" O.C EA WAY

DATE APPROVED: Mar 3, 2017

CLOSE EX CURB OPENING

CITY OF TAKOMA PARK DEPARTMENT OF PUBLIC WORKS

NEW RIVER JACK ROCK RIP RAP

REVERSIBLE FRAME & GRATE, NEW

NEW MH TOP TO MATCH STONE PAVER

SITECAST CONC. RISER STR

APPROVED BY:

6" SCHEDULE 40 CLEAN OUT

DESIGNED BY:

FLOW LINE OF CONC. CHANNEL AT CURB OPENING

NEW TYPE A-5 INLET

KIRKLYNN AND KENEWICK BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM (OPTION-2)

EX CURB OPENING, CONC. CHANNEL, AND STONE PAVER TO REMAIN

MODIFIED DROP INLET W/ BRICK WALLS BEYOND

PROVIDE 3:1 SLOPE BET. BACK OF CURB AND TOP OF POND

BIO RETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM DRAWN BY:

12" RCP, INV 199.20' BEYOND

PORJECT TITLE:

1" = 4'-0"

A. Khalilian, P.E.

A. Khalilian, P.E.

SECTION THROUGH BIORETENTION FACILITY (LINE A-A)

1 SW-7

Z. Mathewos

INV EL 198.38'

#42, EL 201.83'

6" BRICK MASONRY INLET WALL

REVERSIBLE FRAME & GRATE MODEL R-1878-A10G

#17, EL 201.34'

6" REINFORCED CONC. CHANNEL @ CURB OPENING W/ (3) #4 EW

#41, EL 201.85'

15" RCP, OUT

INV 199.20'

6" REINFORCED CONC. INLET BASE W/ (3) # 4 EW

GRATE

SECTION THRU (B-B) STR#2, OPTION-2 SCALE: 3/4" = 1'-0"

1 SW-8 FRAME

95% COMPACTED FILL OR 85% IN GREE AREA 15" HDPE OR RCP

#57 STONE

2 SW-8

SECTION THRU REVERSIBLE FRAME & GRATE ( R-1878-A10G)

TYPICAL. PIPE AND TRENCH SECTION SCALE: 3/4" = 1'-0" PORJECT NAME:

KIRKLYNN AND KENNEWICK AVE BIORETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM CITY OF TAKOMA PARK DEPARTMENT OF PUBLIC WORKS MONTGOMERY COUNTY, MARYLAND

3 SW-8

SCALE: 3/4" = 1'-0" PORJECT TYPE:

DESIGNED BY:

A. Khalilian, P.E.

BIORETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM

DRAWN BY:

Z. Mathewos

APPROVED BY:

A. Khalilian, P.E.

PORJECT TITLE:

DATE APPROVED:

CROSS SECTIONS B-B AND FRAME & GRATE

SCALE:

Mar 23, 2017

3/4" = 1'-0"

SHEET 9 OF 11

NEW SD-1B

205.00'

NEW SD-1A

205.00' NEW SD-2A

TOP OF POND

EL 202.13'

EX GRADE

EL 199.88'

32' @ 2.7%

200.00'

200.00'

EL 198.75'

201.50' @1.

P11,12" HDPE INV. EL 199.20' STA. 0+00

INV. EL 198.21' STA. 0+30.84'

3%

INV. EL 198.38' STA. 0+00

P1,15" RCP

195.00'

195.00'

GAS LINE CROSSING

INV. EL 195.60' STA. 2+35.40'

INV. EL 193.57' 20" RCP @ 2.0%

48" MH

190.00'

190.00' 0+00

0+25

0+50

0+75

1+00

1+25

SD-1B TO SD-1A, SD-1A TO SD-2A STORM DRAIN PIPE PROFILE SCALE:

1" = 20'-0" (H)

1" = 5'-0" (V)

PORJECT NAME:

KIRKLYNN AND KENNEWICK AVE BIORETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM CITY OF TAKOMA PARK DEPARTMENT OF PUBLIC WORKS MONTGOMERY COUNTY, MARYLAND

PORJECT TYPE:

BIORETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM PORJECT TITLE:

PROPOSED STORM DRAIN PROFILE

DESIGNED BY: DRAWN BY: APPROVED BY:

A. Khalilian, P.E.

Sept 18, 2017

AS INDICATED

1+75

2+00

2+25

1 SW-9

A. Khalilian, P.E. Z. Mathewos

DATE APPROVED: SCALE:

1+50

2+50

STORM DRAIN PROFILE

SHEET 10 OF 11

TABLE-2

TABLE-3 STORM DRAIN PIPE SCHEDULE

STORM DRAIN STRUCTURE SCHEDULE STR #

DESCRIPTION

INTERIOR DIMENSION (FT)

Ex.SD-3

202.13

5.00' x 3.00'

SD-1 Ex. SD-2

Ex. "A-5" CMU Inlet

Ex. "A-5" brick Inlet

5.00' x 3.00'

199.88

Ex. Drop Inlet

4.00' x 3.00'

Ex.SD-5

Ex. Conc. Inlet

4.00' x 3.00'

Precast conc. type "A-5"

5.00' x 3.00'

Ex.SD-7

Brick type "A-5"

5.00' x 3.00'

Ex.SD-8

Brick type "A-5"

5.00' x 3.00'

Ex.SD-9

Brick, Box Manhole

Ex.SD-10

SHA, Drop Inlet

198.20

N: 1075139.65' E: 14164491.75'

SD PIPE No.

INV. EL @ STR # AT AT PIPE IN PIPE OUT

P-11

SD-1B @ 199.20 SD-1A @ 198.38

198.38

A-5 Inlet to be installed near gas line. Contractor shall locate gas line before excavation

In/ (P1)15" RCP In/ 8" Cast Iron R.D

194.38

RCP #1 to be connected to ex inlet STR EX SD-2. Contractor shall verify invert elevation and make adjustments if necessary.

N: 1075139.65' E: 14164491.75'

P-1

SD-1A @ 198.38 SD-2A@ 195.60

All pipes and STR are existing. No improvement needed. This information is for design purpose only.

N: 1075451.33' E: 14164429.52'

P-2A

SD-2 @ 194.36

P-2B

196.53

PIPE INFORMATION LENGTH (ft) 32.00'

SLPOE (%) SIZE/TYPE 2.7

12" HDPE

196.12 194.03

201.50'

1.3

40.60'

2.0

20" RCP

Out/ (P5) 15" RCP

194.03

SD-2A @ 193.41 SD-9 @ 191.72

91.60

2.0

20" RCP

SD-2A @ 193.57

NEW PIPE TO BE INSTALLED PIPE IS CONNECTED TO NEW DROP INLET

15" RCP

194.36

In/ (P4) 15" RCP

REMARKS

ADJACENT TO SD-6 INLET EX. RCP TO BE CONNECTED TO A NEW 48" CONC. MH EX. RCP TO BE CONNECTED TO A NEW 48" CONC. MH

198.20

Out/ (P3) 6" PVC

196.35

P-6

SD-6 @ 197.00

SD-9 @ 192.81

78.01

5.4

15" HDPE

199.11

Out/ (P4) 15" RCP

194.94

All pipes and STR are existing. No improvement needed. This information is for design purpose only. But Inlet was clogged with sediment. It needs cleaning.

N: 1075480.60' E: 14164399.93'

P-3

SD-4 @ 196.35

SD-3 @ 196.12

4.50

5.1

6" PVC

EXISTING PIPE TO REMAIN

N: 1075251.35' E: 14164510.86'

N: 1075445.63' E: 14164418.48'

EXISTING PIPE TO REMAIN

199.10

Out/ (P6) 15" HDPE

197.00

All pipes and STR are existing. No improvement needed. This information is for design purpose only.

P-4

SD-5 @ 194.94

SD-3 @ 194.03

35.00

2.6

15" RCP

EXISTING PIPE TO REMAIN

197.20

Out/ (P8) 15" RCP

192.03

All pipes and STR are existing. No improvement needed. This information is for design purpose only.

N: 1075231.60' E: 14164536.40'

P-5

SD-3 @ 194.03

SD-9 @ 192.93

68.20

1.6

15" RCP

EXISTING PIPE TO REMAIN

In/ (P8) 18" RCP In/ (P7) 20" RCP Out/ (P9) 24" RCP In/ (P2) 20" RCP In/ (P6) 15" HDPE In/ (P5) 15" RCP Out/ (P7) 22" RCP

189.91 191.17 189.41

All pipes and STR are existing. No improvement needed. This information is for design purpose only.

N: 1075430.79' E: 14164511.77'

P-7

SD-9 @ 191.67

SD-8 @ 191.17

17.35

2.9

20" RCP

EXISTING PIPE TO REMAIN

191.72 192.81 192.93 191.67

All pipes and STR are existing. No improvement needed. This information is for design purpose only.

N: 1075424.99' E: 14164495.45'

P-8

SD-7 @ 192.03

SD-8 @ 189.91

197.94

1.1

18" RCP

EXISTING PIPE TO REMAIN

In/ (P9) 22" RCP Out / (P10) 60" RCP

186.57 186.24

All pipes and STR are existing. No improvement needed. This information is for design purpose only. N: 1075424.67' E: 14164594.44'

P-9

SD-8 @ 189.41

SD-10 @ 186.07

98.54

3.4

22" RCP

EXISTING PIPE TO REMAIN

P-10

SD-1 @ 186.24

N/A

N/A

2.0

60" RCP

EXISTING PIPE TO REMAIN

197.20

5.50' x 5.00'

LOCATION

All pipes and STR are existing. No improvement needed. This information is for design purpose only.

196.91

10.00' x 4.30'

ADDITIONAL NOTES

Out/ (P1)15" RCP

Out/ (P2) 20" RCP In/(P3) 6" PVC

5.00' x 3.00'

Ex.SD-4

Ex.SD-6

INVERTS MC DOT TOP/RIM ELEV. (ft) STR # PIPE #, IN/OUT ELEVATION (ft)

192.32

PORJECT NAME:

KIRKLYNN AND KENNEWICK AVE BIORETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM CITY OF TAKOMA PARK DEPARTMENT OF PUBLIC WORKS MONTGOMERY COUNTY, MARYLAND

PORJECT TYPE:

BIORETENTION FACILITY WITH OVERFLOW DRAINAGE SYSTEM

DESIGNED BY: DRAWN BY:

A. Khalilian, P.E.

Z. Mathewos

APPROVED BY:

A. Khalilian, P.E.

PORJECT TITLE:

DATE APPROVED:

Sept 18, 2017

PROPOSED AND EXISTING STRUCTURE AND PIPE SCHEDULES

SCALE:

AS INDICATED

STORM DRAIN SCHEDUALE

SHEET 11 OF 11