Covers and Frames Ductile Iron Covers and Frames
262
Ductile Iron Covers and Frames – E600
263
Ductile Iron Covers and Frames – D400
264
Ductile Iron Covers and Frames – B125
267
GripTop – D400
268
Gully Grates – D400
269
Surface Boxes
270
Steel Covers and Frames
273
261
Ductile Iron Covers and Frames
Ductile Iron Covers and Frames – E600 Double Triangular
Standard classifications Ductile Access covers and gully grates installed in the UK should meet the requirements of the European Standard BS EN 124. This applies to all situations, road and off-road, and to all materials. Products designed to BS EN 124 are grouped and classified depending on their place of installation. It is the responsibility of the engineer to ensure that the correct product is specified: “The appropriate class of access covers top or gully top to be used depends upon the place of installation. The selection of the appropriate class is the responsibility of the designer. Where there is any doubt the stronger class should be selected.” Clause 5 BS EN 124.
Markings and badging All covers, gratings and frames shall bear: BS
EN 124 and the appropriate class
The
name and/or identification mark of the manufacturer and the place of manufacture, which may be in code
The
mark of a certification body
Additional
markings required by the customer
Production Access
Recommended for use in trunk roads carrying fast-moving traffic and industrial areas subject to exceptionally heavy traffic eg. dual carriageways, docks and container areas.
identification, i.e. name or reference
covers are offered badged to suit your requirements.
Features: Double
triangular
Non-rock Frame
Loading specifications
design
lifting points
LTS
installation and durability features
HA
104/2 compliant
Sewers for Adoption 6 compliant.
Options: Badging
BS EN124 Loading Class
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Cover Mass (kg)
Total Mass (kg)
610 x 610
815 x 815
150
80*
130
610 x 610
815 x 815
150
79*
130
Open Keyways E600 Closed Keyways E600
options.
* Cover mass per pair.
Recommended for use in trunk roads carrying fast-moving traffic and industrial areas subject to exceptionally heavy traffic eg. dual carriageways, docks and container areas.
Features: Double
Options: triangular
Non-rock HA
design
Badging
options
Security
locking option.
104/2 compliant
Sewers
for Adoption 6 compliant
BS EN 124 Applications
Quality control
Group 1 (min Class A15)
Companies wishing to comply with BS EN 124 must either be independently certified to BS EN 29001 or meet strict quality control procedures stipulated within the standard.
Areas which can only be used by pedestrians and pedal cyclists
Group 2 (min Class B125)
Footways, pedestrian areas and comparable areas, car parks or parking decks
Group 3 (min Class C250)
Full gully tops installed in the area of kerbside channels of roads which when measured from the kerb edge extend a maximum of 0.5m into the carriageway and a maximum of 0.2m into the footway
Group 4 (min Class D400)
Carriageway of roads (including pedestrian streets), hard shoulders and parking areas for all types of road vehicles
Group 5 (min Class E600)
Areas imposing high wheel loads e.g. docks and aircraft pavements
BS EN 124
BS EN 124
Class
Test Load
F900
900kN
E600
600kN
D400
400kN
C250
250kN
B125
125kN
A15
15kN Group 6 (min Class F900)
Areas imposing particularly high wheel loads e.g. aircraft pavements
BS EN 124 Loading Class
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Cover Mass (kg)
Total Mass (kg)
E600
1210 x 685
1375 x 850
150
82*
260
E600
1825 x 685
1985 x 850
150
82*
383
E600
1210 x 685
1375 x 850
150
83*
267
E600
1825 x 685
1985 x 850
150
83*
384
Open Keyways
Closed Keyways
* Cover mass per pair.
262
Utilities | Covers and Frames
The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.
Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.
Utilities | Covers and Frames
263
Ductile Iron Covers and Frames – D400
Ductile Iron Covers and Frames – D400
Hinged Double Triangular
Centre Hinged Double Triangular
Recommended for use in city roads where hinged security is required.
Features: Double
Non-rock
Features: Double
triangular
Hinged
cover design
Frame
lifting points
design
Automatic
cover security locking
Semi-ergonomic
hinging design
LTS
installation and durability features
LTS
installation and durability features
HA
triangular
HA
104/02 compliant
Sewers for Adoption 6 compliant.
104/2 compliant
Options:
Sewers for Adoption 6 compliant.
Badging
Options:
options.
security locking option (including high security version)
BS EN 124 Loading Class
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Cover Mass (kg)
Total Mass (kg)
D400N
600 x 600
806 x 806
100
25▲
82.5
D400N
600 x 600
806 x 806
150
25▲
92.5
Retro-fit
Badging Safety
▲
Heaviest cover.
options
grid options.
100mm deep units BS EN 124 Loading Class
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Cover Mass (kg)
Total Mass (kg)
D400N
600 x 450
800 x 650
100
22.3†
83.5
D400N
600 x 600
800 x 800
100
26.2†
96
D400N
675 x 675
875 x 875
100
40†
127
D400N
750 x 600
940 x 745
100
39†
118
D400N
750 x 750
905 x 940
100
43.3†
131
D400N
900 x 600
1100 x 800
100
40.7†
142
D400N
1060 x 700
1210 x 850
100
51.4†
170
D400N
1220 x 685
1380 x 885
100
38†
217
D400N
1200 x 750
1350 x 945
100
39†
217
D400N
1500 x 750
1660 x 940
100
43†
243
D400N
1800 x 750
1955 x 940
100
39†
317
BS EN 124 Loading Class
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Cover Mass (kg)
Total Mass (kg)
D400N
600 x 600
800 x 800
150
*
*
D400N
675 x 675
875 x 875
150
*
*
D400N
900 x 600
1100 x 800
150
*
*
D400N
1220 x 685
1380 x 885
150
*
*
Site Start Up
Geotechnics
Manhole Solutions
Concrete Pipe and Culvert
Clay Drainage
Plastic Drainage
Surface Water Drainage
Flexible Couplings
Stormwater Management
Rainwater Harvesting
Off Mains Drainage and Separators
PE and Barrier Pipe Systems
Specialist Chemicals
Hard Landscaping – Flag and Kerb
Cable Protection and Access Boxes Reinforcement and Ground Movement Damp Proof and Barrier Membranes
† Heaviest hinged cover.
150mm deep units
Linear Channel Drainage
Access Covers and Gully Gratings
Street Furniture
* Available on request.
Download a copy of our Civils and Drainage Guide at www.keyline.co.uk 264
Utilities | Covers and Frames
The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.
Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.
Utilities | Covers and Frames
265
Ductile Iron Covers and Frames – D400
Ductile Iron Covers and Frames – D400
Double Triangular
Double Triangular
Recommended for use in city roads carrying heavy traffic.
Recommended for use in city roads carrying heavy traffic.
Features:
Features:
Double
triangular
Non-rock
Double
design
Non-rock
LTS
Installation and durability features
HA
HA
design
104/2 compliant
Sewers for Adoption 6 compliant.
104/2 compliant
Options:
Sewers for Adoption 6 compliant.
Options: Security
triangular
Badging
options
Security
locking option.
locking option
Ventilated
option
Safety
grid option on certain units.
150mm deep units BS EN 124 Loading Class
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Cover Mass (kg)
Total Mass (kg)
D400N
600 x 600
803 x 803
150
45*
84
D400N
600 x 600
820 x 770
150
45*
92
D400N
600 dia
820 x 770
150
50*
97
D400N
675 x 675
880 x 830
150
70*
124
D400N
675 x 675
880 x 830
150
69*
122
D400N
750 x 600
960 x 810
150
70*
120
BS EN 124 Loading Class
266
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Cover Mass (kg)
450 x 450
600 x 600
100
32*
53
D400N
600 x 450
800 x 650
100
41*
71
D400N
600 x 600
800 x 800
100
45*
74
D400N
600 x 600
800 x 800
100
49*
82
D400N
600 dia
800 x 800
100
50*
87
D400N
600 dia
800 x 800
100
49*
86
D400N
675 x 675
850 x 830
100
70*
107
D400N
675 x 675
850 x 830
100
69*
106
D400N
675 dia
830 x 830
100
70*
108
D400N
675 dia
830 x 830
100
69*
107
D400N
750 x 600
950 x 800
100
70*
106
D400N
750 x 750
1005 x 1005
100
48
151
D400N
750 x 750
1005 x 1005
100
47
150
D400N
900 x 600
1100 x 800
100
44
131
Depth E (mm)
Cover Mass (kg)
Total Mass (kg)
D400N
1210 x 685
1375 x 850
100
69*
208
D400N
1825 x 685
1985 x 850
100
69*
307
D400N
1210 x 685
1375 x 850
150
69*
241
D400N
1825 x 685
1985 x 850
150
69*
354
D400N
1210 x 685
1375 x 850
100
73*
215
D400N
1825 x 685
1985 x 850
100
73*
318
D400N
1210 x 685
1375 x 850
150
73*
248
D400N
1825 x 685
1985 x 850
150
73*
365
Closed Keyways
Total Mass (kg)
D400N
Over Base C x D (mm)
Open Keyways
100mm deep units BS EN 124 Loading Class
Clear Opening A x B (mm)
* Cover mass per pair.
Ductile Iron Covers and Frames – B125 Slide Out Single Seal Access Cover Suited for use in pedestrian areas, walkways, footpaths, platforms and stations.
Ergonomic
cover operation
Locking
options available
Badging
options available.
Valiant
D400N
900 x 600
1100 x 800
100
43
129
BS EN124 Class
Clear Opening (mm)
Overbase (mm)
Frame Depth (mm)
Total Mass (kg)
D400N
900 x 900
1163 x 1155
125
74
223
B125
600 x 450
750 x 605
75
53
D400N
1250 x 675
1500 x 875
100
70*
201
B125
600 x 600
750 x 750
75
63
D400N
1250 x 675
1500 x 875
100
69*
199
B125
900 x 600
1070 x 770
75
89
Utilities | Covers and Frames
The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.
Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.
Utilities | Covers and Frames
267
Ductile Iron Covers and Frames – B125
Gully Grates – D400
Slide Out Access Cover
Hinged Gully Grates
Suited for use in pedestrian areas, walkways, footpaths, platforms and stations.
For use in heavy and medium duty applications.
Rapide BS EN 124 Class
Clear Opening (mm)
Overbase (mm)
Frame Depth (mm)
Total Mass (kg)
B125
380 x 230
480 x 330
40
14
B125
550 x 325
650 x 425
40
25
Non-rock
Single-piece
B125
450 x 450
550 x 550
40
24
B125
600 x 450
700 x 550
40
31
B125
600 x 600
700 x 700
40
39
B125
750 x 600
850 x 700
40
49
B125
900 x 600
1000 x 700
50
69
B125
1000 x 675
1100 x 775
50
80
B125
1310 x 610
1410 x 710
50
90
Features: Captive
Ergonomic
hinged grating design grating.
cover operation
Locking
options available
Badging
options available.
Description
BS EN 124 Loading Class
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Waterway Area (cm2)
HA102 Reference
Total Mass (kg)
Left Hand Opening
D400
360 x 310
510 x 410
100
765
S
29
GripTop – D400
Left Hand Opening
D400
400 x 430
550 x 520
100
1223
Q
38
Left Hand Opening
D400
500 x 350
645 x 440
100
1080
R
46
High Friction Anti-Skid and Anti-Slip Access Cover Range
Recommended for use in city roads carrying continuous heavy traffic, with the addition of captive hinge for ease of maintenance.
Available in a large range of clear opening sizes, Rapide offers ease and speed of use while promoting operator safety through a cover slide out feature reducing the risk of injury while lifting even for light duty applications.
GripTop is a permanent high friction solution for access cover installations that due to their location pose a slip or skid risk to pedestrians or vehicles.
Features: Captive
GripTop
268
BS EN 124 Class
Clear Opening (mm)
Overbase (mm)
Frame Depth (mm)
Total Mass (kg)
E600
610 x 610
815 x 815
150
126
D400
600 x 600
800 x 800
100
74
D400
600 x 600
800 x 800
150
83
D400
675 x 675
880 x 830
100
94
675 x 675
880 x 830
150
104
D400
600 x 600
806 x 806
100
96
Proven
Demonstrates
D400
600 x 600
806 x 806
150
119
D400
675 x 675
880 x 830
100
109
D400
675 x 675
880 x 830
150
130
D400
600 x 600
800 x 800
100
95
D400
600 x 600
800 x 800
150
106
D400
675 x 675
875 x 875
100
120
D400
675 x 575
875 x 875
150
142
D400
900 x 600
1100 x 800
100
135
D400
900 x 600
1100 x 800
150
144
D400
1220 x 685
1380 x 885
100
214
D400
1220 x 685
1380 x 885
150
249
D400
1830 x 685
2000 x 885
150
354
Utilities | Covers and Frames
Non-rock
Features a patented factory applied high friction treatment which combines high performance bonding agents with a bauxite aggregate applied to a recessed ductile iron cover section.
D400
hinged grating design
Single-piece
grating.
Options: Security
locking option.
in service durability
an industry leading PSRV of > 75.
The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.
Description
BS EN 124 Loading Class
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Waterway Area (cm2)
HA102 Reference
Total Mass (kg)
Kerb Hinging
D400
370 x 430
575 x 630
100
980
R
48
Kerb Hinging
D400
370 x 430
525 x 590
100
980
R
41
Left Hand Opening
D400
370 x 430
575 x 525
100
1020
R
41
Right Hand Opening
D400
370 x 430
575 x 525
100
1020
R
41
Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.
Utilities | Covers and Frames
269
Gully Grates – D400
Surface Boxes
Double Triangular Gully Grate
Grade A Surface Box – Wide Flange
Large waterway area provides efficient water removal in areas subject to high water run-off eg. catchpits, motorway verges, between verges and valleys, cuttings etc.
Recommended for use in city and trunk roads carrying heavy traffic.
Features:
Features:
Double
Non-rock Large
Wider
flange to prevent lateral movement
triangular grating design
Non-rock
waterway area
design
Single-piece
LTS
installation and durability features.
Options:
cover
Badging
options
Security
chain option.
Three
or four flanged frame option.
Description
BS EN 124 Loading Class
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Waterway Area (cm2)
Double Triangular
D400
600 x 600
800 x 800
100
2000
Double Triangular
D400
600 x 600
720 x 800
100
2000
Double Triangular
D400
600 dia
800 x 800
100
Double Triangular
D400
600 x 600
820 x 770
150
HA102 Reference
Grating Mass (kg)
Total Mass (kg)
57*
89
57*
86
2000
57*
92
2000
57*
99
P
BS5834 Grade
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Total Mass (kg)
A
380 x 230
535 x 385
125
27
* Grating mass per pair.
Surface Boxes
Grade A Double Triangular Surface Box Traditional double triangular design for use in city roads carrying heavy traffic.
Grade A Surface Box Recommended for use in city and roads carrying heavy traffic.
Features: Double
triangular
Non-rock
Features: Non-rock
design
Single-piece
270
design
Badging
options
Security
chain option.
cover
Badging
options
Security
chain option.
BS5834 Grade
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Total Mass (kg)
A
150 x 150
225 x 225
100
8.5
A
150 x 150
260 x 245
225
14
A
225 x 225
325 x 325
100
14
A
300 x 300
400 x 400
100
20
A
380 x 230
505 x 355
125
26
A
380 x 230
505 x 355
125
26
Utilities | Covers and Frames
The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.
BS5834 Grade
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Total Mass (kg)
A
430 x 280
550 x 400
100
38
Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.
Utilities | Covers and Frames
271
Surface Boxes
Steel Covers and Frames
Grade A Solid Top Surface Box
Engineered Steel Products
Recommended for use in areas subject to heavy loading but not subject to fast-moving through traffic. Fabricated steel covers provide a highly versatile solution to a large range of access requirements. Keyline is able to supply an extensive range to fulfil even the most demanding specifications.
2 Part Flush Cover
3 Part Flush Cover
Whatever the application, Keyline can provide the solution you need. Recessed
block pavior covers
Recessed
covers for screed infill
Stainless
steel edge or brass edge covers
Hinged
– spring assisted
Manual
handling compliant
Protection MOD
4 Part Recessed
from falling
approved
Security
covers
Ducting
runs
Complete
stainless steel or aluminium
covers Features: Solid
top cover.
BS5834 Grade
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Total Mass (kg)
A
100 x 100
190 x 190
100
6
Grade A Hinged Pavement Surface Box
Kitemarked
precinct range.
All bespoke items are manufactured in accordance to FACTA (Fabricated Access Covers Trading Association) specifications.
Recommended for use in pavements and other pedestrian areas where hinged access is required.
Suggested suitable carrying capacities for standard steel covers and frames* Features: Single-piece
cover
Hinged Badging
272
Ref. A Gross Plated Weight 2.5T. For pedestrian use only.
Ref. E Gross Plated Weight 25T. Will support a slow moving wheel load of 6.25T. Pedestrian precincts, commercial delivery access and emergency services.
Ref. B Gross Plated Weight 5T. Will support a slow moving wheel load of 1.25T. Especially recommended for domestic driveway applications.
Ref. F Gross Plated Weight 38T. Will support a slow moving wheel load of 9.5T. Petrol forecourt and articulated lorries.
Ref. C Gross Plated Weight 10T. Will support a slow moving wheel load of 2.5T. Restricted access and service areas.
Other Traffic Keyline must be notified if inspection covers ordered are to carry vehicles with non pneumatic tyres eg. forklifts, mobile cranes, short wheel trollies etc. plus aircraft or any abnormal traffic.
options.
Utilities | Covers and Frames
BS5834 Grade
Clear Opening A x B (mm)
Over Base C x D (mm)
Depth E (mm)
Spigot I/D F (mm)
Total Mass (kg)
Medium
135 x 125
215 dia
75
4.2
Medium
180 dia
275 x 275
60
7.6
Medium
180 dia
240 x 240
110
202
8.5
Medium
180 dia
240 x 240
110
202
8.5
The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.
Ref. D Gross Plated Weight 17T. Will support a slow moving wheel load of 4.25T. Small rigid commercial vehicles.
Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.
Utilities | Covers and Frames
273
Steel Covers and Frames
Steel Covers and Frames
Hinged Access Covers
Access Covers
Upstanding Single
skin and water shedding
Internal
fixings for increased security
Shrouded
hasp and staple for use with Utility padlocks
Upstanding access covers and frames are designed for use on a variety of projects containing chambers that are opening frequently and are not subject to vehicular traffic. The upstanding range incorporates torsion spring assistance for ease of opening by one person and are frequently used over wet wells, valve and screen chambers, but are not limited to this application. This range is particularly useful on refurbishment sites that require an economical solution that will be easily installed within existing conditions.
Precinct Designed
Kitemarked
as standard with single hinged safety grids
Depth
Torsion
Solid
spring assisted for one person operation
Covers
Slide
from 6mm material.
to suit 65mm blocks
base flange to ensure stability under load
incorporate safety stays to prevent accidental closure
Anti-Slip
in accordance to BSEN124
class B125 Manufactured
Supplied
Galvanised
in accordance with BT spec
LN593
Mild steel high quality access covers are available to suit a multitude of applications and infill materials. These ranges are fabricated to the highest standards to ensure continued performance under operation and load.
Hot
to BSEN ISO1461
out design for easy removal
dip galvanized to BS EN ISO 1461
Available
in a range of sizes to suit chamber references 2,4,5,6,10,11 & JC1
and powder coatings are available.
Size Range Available in a multitude of sizes from 300 x 300mm, to suit any chamber opening dimensions.
Non
kitemarked ranges of paviour units are also available.
Cover configuration include Single Twin – In line hinged Twin – End hinged Triple – In line hinged Triple – End and mid hinged Multiple configurations. Biomass Multiple
Stamplock Flush
fitting access cover
Internal
fixings for increased security
Recessed
Stamp-Lock locking for use with Utility padlocks
Supplied
as standard with single hinged safety grids
The Keyline range of flush fitting access covers and frames include the unique Stamp-Lock locking device as standard. The Stamp-Lock devices allow for the padlock to be contained within the locking device and is extremely easy to open and close. The range has been designed for use for use on a variety of projects containing chambers that are opened frequently and are subject to slow moving vehicular traffic. The range incorporates torsion spring assistance for ease of opening by one person. Stamp-Lock products, are frequently used over wet wells, valve and screen chambers, but are not limited to these applications. They also include sealed and unsealed variations, with differing frame depths for ease of installation.
gas ram and spring assisted single person operation
Galvanised
to BSEN ISO1461.
Keyline provide access solutions for high profile schemes that use heating systems, which are powered by Biomass fuel. To continue to provide up to date cost effective solutions for varying applications, Steelway now have available a light duty gas assisted hinged access cover for storage facilities that are not subject to vehicular access. The new product compliments the existing range of large opening modular cladded buildings and extremely popular flush fitting hydraulic fuel storage covers.
Torsion
spring assisted for one person operation
Covers
incorporate safety stays to prevent accidental closure
Galvanised Anti-Slip
™
to BSEN ISO1461
and powder coatings are available.
Size Range Available in a multitude of sizes from 300 x 300mm, to suit any chamber opening dimensions. Cover configuration include Single Twin – In line hinged Twin – End hinged Triple – In line hinged Triple – End and mid hinged Multiple configurations.
274
Utilities | Covers and Frames
The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.
Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.
Utilities | Covers and Frames
275
Steel Covers and Frames
Steel Covers and Frames
High Security Access Covers
Galvanised Steel Solid Top Access Covers
Sentry Moated
twin skin high security access cover and frame
Specific
products and configurations are LPS1175 SR4 certified
Internal
fixings for increased security
Our range of Sentry High Security access covers and frames include products designed and fabricated in line with LPS1175 SR4 specification. The range has been designed for use on a variety of projects including clean water reservoir chambers. The range incorporates torsion spring assistance for ease of opening by one person. On projects which require non standard sizes and products which sit outside of the scope of the specification, we have the flexibility to design and fabricate in line with the same requirements but note that they will not be certified.
Supplied
as standard with single hinged safety grids
5T GPW
17T GPW
spring assisted for one person operation
Clear Opening (mm)
Overall Size (mm)
300 x 300
363 x 363
450 x 450
513 x 513
600 x 450
663 x 513
600 x 600
663 x 663
600 x 450
663 x 513
600 x 600
663 x 663
Torsion
Please contact Keyline for advice should you require units slightly over the specifications shown. Gross vehicle plated weight expressed as the gross weight of road vehicles with pneumatic tyres and four points of road contact.
Covers
incorporate safety stays to prevent accidental closure
Galvanised
to BSEN ISO1461.
Loads to FACTA classes can be supplied on request.
Size Range Available in a multitude of sizes from 300 x 300mm, to suit any chamber opening dimensions. Covers configurations include Single Twin – In line hinged Twin – End hinged Multitude configurations and bespoke layouts with lift off units.
Chequer Plate Covers
Finishes include Galvanised mild steel Self colour stainless steel Powder coated to all available RAL colours Non slip coating.
5T GPW
Loadings Pedestrian duty for use in areas not subjected to vehicular traffic.
276
Utilities | Covers and Frames
38T GPW
The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.
Clear Opening (mm)
Overall Size (mm)
Overall Depth (mm)
600 x 450
656 x 506
50
600 x 600
656 x 656
50
750 x 600
824 x 674
50
900 x 600
974 x 674
50
450 x 450
510 x 510
50
600 x 450
660 x 510
50
600 x 600
660 x 660
50
600 x 510
656 x 506
50
Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.
Utilities | Covers and Frames
277
Steel Covers and Frames
Steel Covers and Frames Square-to-Round Recessed Cover
Recessed Access Covers Internal Recessed Type Sealed and Locking Clear Opening (mm)
Overall Size (mm)
300 dia
440 x 440
5 Tonne GPW
450 dia
580 x 580
600 x 450
740 x 590
600 x 450
740 x 590
600 x 600
740 x 590
750 x 600
850 x 700
750 x 750
850 x 850
900 x 600
1000 x 700
Square-to-Round Recessed Cover Quick
and easy to install
Cover
can be turned to match direction of paving
Clear Opening (mm)
Circular
opening in frame fits all major PPIC inspection chambers
Guaranteed Galvanised
interchangeability
to BS EN 1461.
Eliminates
the need to cut paving round a circular opening
Depth (mm)
Overall Size (mm)
Loading GPW
300
80
438 x 438 x 93
Driveway
450
80
580 x 580 x 88
Driveway
450
43.5
580 x 580 x 54
Driveway
Recessed Access Covers Internal Recessed Type Sealed and Locking (treated to 1 metre head of pressure)
5 Tonne GPW
Block
Clear Opening (mm)
Overall Size (mm)
450 x 450
550 x 550
600 x 450
700 x 550
600 x 600
700 x 700
750 x 600
850 x 700
750 x 750
850 x 850
900 x 600
1000 x 700
Cover
Frame
CLKS 450SR
Recessed Access Covers Standard 450mm dia PPIC chamber
Paviour Type Clear Opening (mm)
Overall Size (mm)
300 dia
438 x 438
450 dia
580 x 580
600 x 450
695 x 545
600 x 450
695 x 545
600 x 450
700 x 650
600 x 600
690 x 690
600 x 600
700 x 700
750 x 600
850 x 700
750 x 750
850 x 850
10 Tonne GPW
38 Tonne GPW
278
900 x 600
1000 x 700
900 x 900
1000 x 1000
1200 x 600
1300 x 700
600 x 600
800 x 800
750 x 600
950 x 800
750 x 750
950 x 950
900 x 900
1100 x 1100
1200 x 600
1400 x 800
Utilities | Covers and Frames
See our Geotechnics Guide for more information
The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.
Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent. Keyline Utilities reserve the right to change product specifications without further notification.
Utilities | Covers and Frames
279
Utilities Stock Range
Visit www.keyline.co.uk to find out more information on specialist utilities products now in stock. 280
Utilities | Covers and Frames
The information in this brochure is to the best of our knowledge true and accurate, but all recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Keyline disclaim any liability for loss or damage suffered from the use of these data or suggestions.