Counter Rotating Fan 60mm
60
Counter Rotating Fan ■ Features
High static pressure Maximum static pressure is increased by approx. 1.8 times*2 compared with our conventional product*1.
Energy-saving Power consumption is reduced to approx. 72%*2, 3 compared with our conventional product *1.
*1: Our conventional product is the 60sq.×76mm thick. San Ace 60, Model No. 9CR0612S001. *2: Specification of Model No. 9CRA0612P0G001. *3: When air flow and static pressure is almost identical.
60×60×76mm
CRA type
■ Specifications Model No.
Operating Rated Voltage Voltage Range [V] [V]
PWM Duty Cycle [%]
Note1)
100
9CRA0612P0G001 12
10.8 to 13.2
9CRA0612P0S001
0 100 0
Rated Current Rated Input Rated Speed[min-1] Max. Air Flow [A] [W] Inlet Outlet [m3/min] [CFM]
2.3
27.6
0.22
2.7
1.5
18.0
0.17
2.1
16,500 13,000 3,600
2,800
14,000 11,000 3,200
2,500
2.0
70.6
0.43
15.1
1.7
60.0
0.38
13.4
MAX. Static Pressure SPL [Pa] [inchH2O] [dB(A)]
1,000 47.6 720 37.6
4.0
66
0.19
32
2.89
63
0.15
29
Operating Temperature [℃]
Expected Life Note2) [h]
−10 to +70
40,000/60℃ (70,000/40℃)
Note1 : PWM Frequency:25kHz Note2: Expected life at 40 degreeC ambient is just reference value.
■ Common Specifications □ Material ・・・・・・・・・・・・・・・・・・・・・・・・・・ Frame, Impeller : Plastics (Flammability: UL94V-0) □ Expected Life ・・・・・・・・・・・・・・・・・・・・・ Varies for each model (L10: Survival rate: 90% at 60℃, rated voltage, and continuously run in a free air state) □ Motor Protection System ・・・・・・・・・・ Current blocking function and Reverse polarity protection □ Dielectric Strength ・・・・・・・・・・・・・・・・ 50/60 Hz, 500VAC, 1 minute (between lead conductor and frame) □ Sound Pressure Level (SPL) ・・・・・・・・ Expressed as the value at 1m from air inlet side □ Storage Temperature ・・・・・・・・・・・・・・ −30℃ to +70℃ (Non-Condensing) +Red ○ ーBlack Sensor: Yellow Control: Brown □ Lead Wire ・・・・・・・・・・・・・・・・・・・・・・・・ Inlet : ○ Outlet : ○ +Orange ○ ーGray Sensor: Purple Control: White
□ Mass ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Approx. 270g
60mm
□ Operating Temperature ・・・・・・・・・・・・ Varies for each model (Non-condensing)
60 ■ Air Flow - Static Pressure Characteristics ・ PWM Duty Cycle
・ Operating Voltage Range
PWM Duty Cycle 100%
1,000
4.0
(inch H2O)(Pa) 5.0 1,200
DC 12V
800
3.0
600 2.0 400 50%
1.0
PWM Duty Cycle 100% 13.2V
→ Static pressure
→ Static pressure
(inch H2O(Pa) ) 5.0 1,200
4.0
12V
3.0
800
600 2.0
10.8V
400 1.0
200
1,000
200
0%
0
0.5 10
1
1.5
2
2.5 (m3 /min)
0
(CFM)
20 30 40 50 60 70 80
10
→ Air flow
9CRA0612P0G001
4.0
3.0
1,000 PWM Duty Cycle 100%
600 2.0
50%
400 1.0
(CFM)
20 30 40 50 60 70 80
→ Air flow
(inch H2O)(Pa) 5.0 1,200
DC 12V
800
2.5 (m3 /min)
2
1.5
9CRA0612P0G001
→ Static pressure
→ Static pressure
(inch H2O)(Pa) 5.0 1,200
1
0.5
4.0
3.0
1,000
13.2V
800 12V
600 2.0
10.8V
400 1.0
200
PWM Duty Cycle 100%
200
0% 0
0.5 10
1
1.5
2
2.5 (m3 /min)
0
(CFM)
20 30 40 50 60 70 80
1
0.5 10
1.5
2.5 (m3 /min)
2
20 30 40 50 60 70 80
→ Air flow
→ Air flow
9CRA0612P0S001
9CRA0612P0S001
(CFM)
■ PWM Duty - Speed Characteristics Example Voltage:DC12V PWM Frequency:25kHz
Voltage:DC12V PWM Frequency:25kHz
18,000
18,000 16,500 min-1
16,000
16,000
12,000 10,000
3,600min-1
8,000
Outlet Side
6,000
0
Inlet Side
12,000
11,000 min-1
10,000 8,000
3,200min-1
6,000
Outlet Side
4,000
4,000 2,000
14,000 min-1
14,000
13,000 min-1
Inlet Side
Speed(min-1)
Speed(min-1)
14,000
2,800min-1
0%
PWM Duty Cycle(%)
9CRA0612P0G001
2,500min-1
2,000 100%
0
0%
PWM Duty Cycle(%)
9CRA0612P0S001
100%
60×60×76mm ■ PWM Input Signal Example Input Signal Wave Form
VIH=4.75V to 5.25V VIL=0V to 0.4V
VIH
T1 T ×100 PWM Frequency 25(kHz)= 1 T Source Current(Isource): 5mA Max. at control voltage 0V PWM Duty Cycle(%)=
VIL
Sink Current(Isink): 5mA Max. at control voltage 5.25V
T1
Control Terminal Voltage : 5.25V Max. (Open Circuit) When the control lead wire is open, speed is same as one at 100% PWM duty cycle.
T
This fan speed should be controlled by PWM input signal of either TTL input or open collector, drain input.
■ Connection Schematic
80×8 Inside of DC fan
DC fan input voltage
+ ○
PWM Input Signal Control Isource Isink
− ○
■ Specifications for Pulse Sensors Output circuit : Open collector
VCE=+13.8V MAX. Ic=5mA MAX.[VOL=VCE(SAT)=0.6V MAX.]
Inside of DC fan + ○
Sensor
Pull-up resistor VCE Ic
Sensor output − ○
Output waveform (Need pull-up resistor) T1∼4≒(1/4)T0
In case of steady running (One revolution)
N=Fan speed(min-1)
T0 T1 VOH VOL 0V
T2
T1∼4≒(1/4)T0=60/4N(sec)
T3
T4
■ Dimensions (unit : mm) Outlet Side
+50
4-Ø4.5±0.3
60±0.5
300 0
Mounting Hole
(10)
(4)
76±0.5
50±0.3
(4)
50±0.3
(10) +50 300 0
Lead Wire AWG26 UL1430
60±0.5
Inlet Side
4-Ø4.5±0.3 Mounting Hole
Rotating Direction
Air Flow Direction
Rotating Direction
■ Reference dimension of mounting holes and vent opening (unit : mm) Inlet Side , Outlet Side 59 50±0.3 29.7
59
50±0.3
29.7
62
.7
4-Ø4.5
●The products shown in the catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited. ●To protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. 1-15-1, Kita-otsuka, Toshima-ku,Tokyo 170-8451, Japan. PHONE :+ 81 3 3917 5151
http://www.sanyodenki.com