CV-800EP Serial to Wiegand Converter Installation ... - ELVESsupply

Report 14 Downloads 92 Views
CV-800EP Serial to Wiegand Converter Installation Instructions Compatible with Viscount Enterphone 2000 ™ and any access control system utilizing 26 bit wiegand format card records.

Description The CV-800EP is a Serial to Wiegand Converter for the Viscount Enterphone 2000 ™ Telephone Entry System (firmware version 2.4 or higher is required). It captures the code a visitor enters into the lobby panel, converts it to a 26 bit Wiegand Format, then sends it to an Access Control System only when the Resident that was called, enters a “9” or a “6”. The CV-800EP also has a connection for the Postal Lock Switch. When the normally open postal lock switch is activated, the CV-800 will send “9999” in 26 bit Wiegand format to the Access Control System.

To install the CV-800EP > Step One Connect the Male DB9 Connector to J11 of the Enterphone 2000™ Central Control Unit.

to access control panel reader port.

> Step Two

Red Reader +12 Volts Black Reader 0 Volts Green Reader Data 0 White Reader Data 1 Blue Postal Lock Switch Orange Postal Lock Switch

Connect the 22/6 conductor cable to your Access Control Panel as follows: a) Red wire to Access Control Reader input +12V. b) Black wire to Access Control Reader input 0V. c) G  reen wire to Access Control Reader input Data 0. d) White wire to Access Control Reader Input Data 1. e) Orange wire to Postal Lock Switch Common. f) B  lue wire to Postal Lock Switch Normally Open.

> Step Three

The Baud Rate must be set to 9600 (see the Enterphone 2000 Manual for Instructions)

www.camdencontrols.com Toll Free: 1.877.226.3369

RS 232

22/6c stranded shielded

CV-800EP Wiegand Interface for Enterphone 2000(tm)

Format: 26 bit Wiegand Facility Code-0 DB9 —> J11 Control Unit Red —> Reader +12V Baud Rate: 9600 Black —> Reader 0V Green —> Reader Data 0 Postal Lock N/O Switch White —> Reader Data 1 Orange —> Postal Lock (N/O) Blue —> Postal Lock (N/0) *** Postal Lock when activated sends card #9999 ***

To J11 of Enterphone 2000™ Central Control Unit

NOTE: The CV-800EP can only be used with Single Lobby Panel Systems, Multi Lobby Panel Systems will be supported at a later date.

Discover the best in door activating and locking products!

CV-800EP Revised: Feb 17, 2009 Part No: 40-82B095

CV-800EP Serial To Wiegand Converter Installation Instructions

From Enterphone 2000 Manual

Specifications

K.7 Extracting Usage Data from an Enterphone System

Output Format:

K.7.1 Setting up Communications with the Common Control Unit (CCU)

26 bit Wiegand

Only software version 2.4 and up provides the data output capability. Earlier software versions will not work. To find the software version, check the label on top of IC U9 inside the CCU. 1. Two baud rates are available, either 1200 or 9600, and are selectable with jumper W3, from inside the CCU. The top position is 1200 baud and the lower position is 9600 baud.



Facility Code: 0 (zero)

Power Supply: 9/14VDC (Linear Power Supply Recommended)

Maximum Current Requirements: Average 7mA, Peak 10mA.

Cable Distance: 300 Feet (90 Metres) Recommended cable (22AWG) 6 conductor Stranded with overall shield.

Warranty: 3 Year Warranty against defects in materials and workmanship.

(TM) Enterphone 2000 is a registered trademark of Viscount Communications and Control Systems Inc.

Push Buttons

Key Pads

www.camdencontrols.com Toll Free: 1.877.226.3369

Strikes

Magnetic Locks

Key Switches

Relays & Timers

Discover the best in door activating and locking products!

Access Control