D-Series Size 3

Report 5 Downloads 39 Views
D-Series Size 3

Catalog Number

LED Flood Luminaire

Notes

Type

Hit the Tab key or mouse over the page to see all interactive elements.

Introduction

Specifications EPA: Depth: Width:

W

The D-Series Size 3 Flood features precision optics to beautifully illuminate a variety of applications as its sleek, compact styling blends seamlessly with its environment.

D

1.4 ft2

The D-Series Flood reflector systems and cuttingedge chip-on-board LED technology produce low field-to-beam ratios for minimal spill light and incredible photometric performance. It’s the ideal long-life replacement for 250 - 400W metal halide floods, with typical energy savings of 67% and expected service life of over 100,000 hours.

(0.13 m2)

5” (12.7 cm)

H

13” (33.0 cm)

Height:

13-5/8”

Overall Height

17-1/2”

Weight:

21 lbs

OH

(34.6 cm) (44.5 cm) (9.5 kg)

Ordering Information

EXAMPLE: DSXF3 LED 8 A530/40K FL MVOLT THK DDBXD

DSXF3 LED Series DSXF3 LED

Light Engines 6 8

Six COB engines Eight COB engines

Performance Package

Distribution

530 mA options: A530/30K 3000K A530/40K 4000K A530/50K 5000K

NSP MSP MFL

Voltage

Narrow spot Medium spot Medium flood FL Flood WFL Wide flood WFR Wide flood, rectangular HMF Horizontal medium flood

MVOLT 1 120 1 208 1 240

1

277 1 347 480

Mounting Shipped included THK Knuckle with 3/4” NPT threaded pipe YKC62 Yoke with 16-3 SO cord IS Integral slipfitter (fits 2-3/8” O.D. tenon) Shipped separately 2 FTS CG6

FRWB DDBXD U

Radius wall bracket, 2-3/8” OD tenon (specify finish)

FSPB DDBXD U

Steel square pole bracket, 2-3/8” OD tenon (specify finish)

Shipped installed PER DMG DCR

DDBXD NEMA twist-lock receptacle only (no controls) 0-10V dimming driver (no controls) Dimmable and controllable via ROAM® (no controls) 3 Single fuse (120, 277, 347V) 4 Double fuse (208, 240, 480V) 4 Utility terminal block

DBLXD DNAXD DWHXD

Dark bronze Black Natural aluminum White

SF DF WTB Shipped separately 2 UBV Upper/bottom visor (universal) FV Full visor VG Vandal guard WG Wire guard SC

Shorting cap 5

DLL127F 1.5 JU DLL347F 1.5 CUL JU

Photocell - SSL twist-lock (120277V) 5 Photocell - SSL twist-lock (347V) 5

DLL480F 1.5 CUL JU

Photocell - SSL twist-lock (480V) 5

1

Ordered and shipped separately.

Slipfitter for 2-3/8” to 2-7/8” OD tenons; mates with yoke mount (specify finish)

Tenon slipfitter (fits 2-3/8” to 2-7/8” O.D. tenon. YKC62 required)

Finish (required)

NOTES

Accessories FTS CG6 DDBXD U

Options

DSXF3UBV DDBXD U Upper/bottom visor accessory (specify finish) DSXF3FV DDBXD U

Full visor accessory (specify finish)

DSXF3VG U

Vandal guard accessory

DSXF3WG U

Wire guard accessory

For more mounting options, visit our Floodlighting Accessories pages. For more control options, visit DTL and ROAM online.

2 3

4 5

MVOLT driver operates on any line voltage from 120-277V. Specify 120, 208, 240 or 277 options only when ordering with fusing (SF, DF options). Also available as separate accessories; see Accessories information at left. Specifies a ROAM® enabled luminaire with 0-10V dimming capability; PER option required. Not available with 347 or 480V. Additional hardware and services required for ROAM® deployment; must be purchased separately. Call 1-800-442-6745 or email: [email protected]. Single fuse (SF) requires 120, 277 or 347 voltage option. Double fuse (DF) requires 208, 240 or 480 voltage option. Requires luminaire to be specified with PER option. Ordered and shipped as a separate line item.

One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • Fax: 770.918.1209 • www.lithonia.com © 2012-2013 Acuity Brands Lighting, Inc. All rights reserved.

Performance Data Lumen Ambient Temperature (LAT) Multipliers

Lumen Output

Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F).

Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Actual performance may differ as a result of end-user environment and application. Actual wattage may differ by +/- 8% when operating between 120-480V +/- 10%. Contact factory for performance data on any configurations not shown here.

Light Engines

Drive Current (mA)

6

Performance Package

530

8

530

Dist. Type

System Watts

A530/--K

°H

NSP MSP MFL FL WFL WFR HMF NSP MSP MFL FL WFL WFR HMF

115W

A530/--K

Field Angle

158W

40K (4000K, 70 CRI)

Beam Angle

Ambient

50K (5000K, 67 CRI)

°V

°H

°V

Max Cd

Lumens

LPW

Max Cd

Lumens

LPW

48 49 50 48 60 60 85 84 106 106 107 88 100 62 48 49 50 48 60 60 85 84 106 106 107 88 100 62

19 24 47 63 71 85 80 19 24 47 63 71 85 80

19 23 46 62 72 64 13 19 23 46 62 72 64 13

39,299 36,284 15,104 9985 7488 7460 6779 51,658 47,694 19,854 13,125 9843 9805 8911

7471 8373 8948 9730 10,230 10,461 3301 9820 11,006 11,761 12,790 13,448 13,751 4338

65 73 78 85 89 91 29 62 70 74 81 85 87 27

39,177 36,171 15,057 9954 7465 7436 6758 51,496 47,546 19,792 13,084 9812 9775 8883

7448 8347 8920 9700 10,199 10,429 3290 9790 10,971 11,725 12,750 13,406 13,708 4325

65 73 78 84 89 91 29 62 69 74 81 85 87 27

Lumen Multiplier

0°C

32°F

1.05

10°C 20°C 25°C 30°C 40°C

50°F 68°F 77°F 86°F 104°F

1.03 1.01 1.00 0.99 0.97

Projected LED Lumen Maintenance Data references the extrapolated performance projections for the DSXF LED 8 A530 platform in a 25°C ambient, based on 8400 hours of LED testing (tested per IESNA LM-8008 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Operating Hours

0

25,000

50,000

100,000

Lumen Maintenance Factor

1.0

0.94

0.90

0.84

Electrical Load Current (A)

Photometric Diagrams

Light Engines

Drive Current (mA)

System Watts

120

208

240

277

347

480

6

530

115W

1.06

0.61

0.53

0.46

0.37

0.27

8

530

158W

1.46

0.84

0.73

0.63

0.51

0.37

To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s D-Series Flood Size 3 homepage.

-40°

-20°



20°

40°

60°

80°

10%

60°

20%

40°

30%

20°

40%



50%

-20°

60%

-40°

75%

-60°

90%

-80°

MSP

-80°

-60°

-40°

-20°



20°

40°

60°

80°

80° 60° 40° 20° 0° -20° -40° -60°

FL

-80°

-80°

-60°

-40°

-20°



20°

40°

60°

80°

80° 60° 40° 20° 0° -20° -40° -60° -80°

WFL

-80°

-60°

-40°

-20°



20°

40°

60°

80° 60° 40° 20° 0° -20° -40° -60°

HMF

-80°

80°

Test No. LTL22159P12 tested in accordance with IESNA LM-79-08.

-60°

Test No. LTL22174P12 tested in accordance with IESNA LM-79-08.

-80° 80°

Test No. LTL22153P12 tested in accordance with IESNA LM-79-08.

(% Max cd)

Test No. LTL22173P12 tested in accordance with IESNA LM-79-08.

Isocandela plots for the DSXF3 LED 8 A530/40K. LEGEND

FEATURES & SPECIFICATIONS

CONSTRUCTION Die-cast aluminum housing has integral heat sink fins to optimize thermal management through conductive and convective cooling. The LED driver is mounted in direct contact with the casting to promote low operating temperature and long life. Housing is completely sealed against moisture and environmental contaminants (IP65). Low EPA (1.4 ft2) for optimized wind loading.

ELECTRICAL Light engines consist of chip-on-board (COB) LEDs directly coupled to the housing to maximize heat dissipation and promote long life (100,000 hrs at 25°C, L84). Class 1 electronic driver has a power factor >90%, THD