Item Quantity
LoH2O
CSI Section 11400
™
Approval Date
Models
LoH2O™
Project
LoH 2O (JFT)
Options Blower dryer Additional wash section Additional load module Additional unload module 25’ (8m) wash down hose - mounted Electrical connection with circuit breakers Dual point electrical connection Low profile doors Flanged feet Multiple conveyor peg choice Drain at load or unload end Prison Package
Standard Features • Uses 58 gallons (219.5 liters) of water per hour with sanitizing hot water rinse • All tanks and hoods constructed from 16 gauge 304 stainless steel with a No. 3 finish and heliarced welded • Stainless steel frame, legs and feet • Two tank rackless conveyor shall have a maximum capacity of 11,094 dishes per hour at a belt speed of 6.7 (2.0 M) feet per minute. At 5.3 feet (1.6 M) per minute capacity will be 8,772 dishes per hour • Belt width of 29” (737 mm) and a maximum clearance of 25” (635 mm) throughout the machine • Rear enclosure panels, hood and doors are stainless steel and double-wall insulated to reduce heat dissipation, outside surface temperatures, and noise pollution • Insulated access doors for easy access, cleaning and servicing • Sloped tank(s) design to increase visibility and accessibility for cleaning as well as ensure complete tank draining • Heated power rinse zone uses fresh rinse water a second time to provide pristine results
• Exclusive Rainbow Rinse™ features an arched, removable upper rinse arm that provides superior rinse action while reducing water usage • A sequential digital temperature readout of each tank housed in the door of the electrical control panel. The readouts will constantly display the temperature of the pre-wash, wash, power rinse and final rinse in 5 second intervals • A ball valve in the drain line of each tank and interconnected to a common machine drain connection at the load end of the machine • Each tank will be automatically filled and maintained by a dual water level float. Water will be automatically added to the machine when required • Block manifold wash arms are easy to remove, clean, and replace with nonclogging convex wash arm jet • Large, removable scrap screens • Pre-wash includes a deep-well removable scrap basket in addition to a large removable scrap screen • Self draining stainless steel pumps, impellers, and housings are readily accessible and serviceable • Service access from front of machine
SHIPPING ADDRESS
MAILING ADDRESS
Tel: 1-888-800-5672
6209 North U.S. Highway 25E
P.O. Box 1060
Fax: 606-523-1799
Gray, KY 40734
Barbourville, KY 40906
[email protected] • Conveyor belt drive operates at two speeds and is protected by an overload safety device and an automatic shut-down actuator • Each door is equipped with a safety switch. If a door is opened during operation the switch will immediately shut down the pumps and belt • Operator activated start-stop switches on both the load and unload ends and the control panel • Belt tension adjustment • Removable insulated panels to enclose the unit down to the base frame on both the front and rear of the machine • A single, built-in 18” square (457 mm x 457 mm) indirect vent connection with a 0.19 hp exhaust fan mounted in a cleanable cross duct on the machine for exhaust steam removal and indirect vent connection • 3” minimum wall clearance
www.jacksonmsc.com
1 of 8
1'-23 4" [375mm] 3" [76mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)
5
2 1
4
3 3' [914mm]
3' [914mm]
3' [914mm]
3' [914mm]
3' [915mm]
1" [1943mm] 6'-42 Control Cabinet Door Open
1" [972mm] 3'-24
6
3' [914mm]
7
12'-7" [3836mm]
2'-33 4" [706mm]
2'-53 8" [746mm] 2'-43 8" [721mm] 1" [234mm] 94
1" [743mm] 2'-54
1" [1048mm] 3'-54 1" [971mm] 3'-24
3'-10" [1168mm]
1" [486mm] 1'-78
1" [4712mm] 15'-52 13'-6" [4115mm]
9" [229mm] 1" [486mm] 1'-78
Electric
3" [76mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)
3'-6" [1067mm]
18'-6" [5639mm]
DIRECTION OF OPERATION
3" [72mm] Deep
3' [914mm] 1" [129mm] 58 TYPICAL 6
13'-6" [4115mm] 1" [4712mm] 15'-52
Steam Vapor Exhaust Duct Minimum 18" Square (Cross Section 324 Sq. In.) Provided by HVAC Contractor
Exhaust Requirements - 1200 CFM
Condensate duct to extended into duct pan.
Condensate duct pan mounted on top of dishmachine electrical section.
Legend 1 - 2" NPT Machine Drain Connection (Floor drain - optional to either end) 2 - *Wash Tank Electrical Connection 3 - *Rinse Tank Electrical Connection 4 - *Booster Heater Electrical Connection 5 - *Motor Controls Electrical Connection 6 - 3/4" NPT Incoming Water Connection 7 - Vent Connection - See Detail *See Table For Amp Draw
Note: The steam vapor removal system built into the dishmachine consists of a fan that will remove 1200 CFM. A single steam vapor connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 1200 CFM from the area.
2 of 8
Visit us at www.jacksonmsc.com or call us at 1-888-800-5672
6'-10" [2083mm] Top of Exhaust Fan Housing
7
5'-43 4" [1644mm]
5
103 4" [273mm]
1
6'-10" [2083mm] A.F.F.
4
6" [152mm]
12'-7" [3836mm]
18" [457mm] I.D. Square
3
6" [152mm]
87 8" [226mm]
3' [914mm]
6'-1" [1855mm]
7'-6" [2286mm] Optional - Short Doors In The Open Position
8'-8" [2642mm] Doors In The Open Postion
2
9'-0" [2743mm] Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
Power Connections Inside Control Panel
1" [743mm] 2'-54
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)
1" [234mm] 94
5
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)
2 1
4
3
3'-6" [1067mm]
3' [915mm]
3' [914mm]
3' [914mm]
3' [914mm]
1" [1048mm] 3'-54
2'-53 8" [746mm] 2'-43 8" [721mm]
3'-10" [1168mm]
7
1" [971mm] 3'-24
12'-7" [3836mm]
6
1'-23 4" [375mm]
1" [486mm] 1'-78
9" [229mm]
13'-6" [4115mm]
2'-33 4" [706mm]
3' [914mm]
1" [972mm] 3'-24
3' [914mm]
18'-6" [5639mm]
DIRECTION OF OPERATION
3' [914mm] 6" [152mm]
1" [129mm] 58 Typical
1 12'-7" [3836mm] 13'-6" [4115mm]
6
1" [4711mm] 15'-52
Jackson Electric Rackless Conveyor
Jackson Electric Rackless Conveyor with Blower Dryer
Wash, Power Rinse & Final Rinse
Wash, Power Rinse & Final Rinse
Electrical requirements with booster*
Electrical requirements with booster* Heater kW
Pump HP
Wash Heater & Pump Section
24
3
75.5
63.5
31.8
Power Rinse Heater & Pump Section
33
3
100.5
84.3
42.1
-
3
11.4
10.4
5.4
Pre-Wash Pump, Motors & Controls Booster*
8'-8" [2642mm] Doors In The Open Position
2
7'-6" [2286mm] Optional - Short Doors In The Open Position
3
7
6'-1" [1855mm]
4
3' [914mm] 103 4" [273mm]
5'-43 4" [1644mm]
6'-10" [2083mm] Top of Exhaust Fan Housing
5
9'-0" [2743mm] Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
Power Connections Inside Control Panel
6" [152mm] 87 8" [226mm]
1" [1943mm] 6'-42 Control Cabinet Door Open
1" [486mm] 1'-78
1" [4712mm] 15'-52
18†
Totals *70° F rise booster †208V booster is 17.2kW
208V
230V
Heater kW
Pump HP
Wash Heater & Pump Section
24
3
75.5
63.5
31.8
Power Rinse Heater & Pump Section
33
3
100.5
84.3
42.1
Pre-Wash Pump, Motors, Blower Dryer Heater & Controls
9
3
43.6
39.4
19.9
460V
47.7
41.5
20.8
Booster*
235.1
199.7
100.1
Totals
18†
208V
230V
460V
47.7
41.5
20.8
267.3
228.7
114.6
*70° F rise booster †208V booster is 17.2kW
JFT (electric) comes standard with 4-point electrical hookup. For other variations, please contact the factory. If water hardness exceeds 3 grains, a water softener is required We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.
3 of 8
Load
Pre-Wash Tank
Wash Tank
A “start/stop” switch is located at the load end of the machine for the operator’s convenience.
The pre-wash tank features a stainless steel manifold system with stricturefree jets to optimize pressure for soil removal and to provide easy access for removal and cleaning.
The wash tank features a stainless steel manifold system with stricture-free jets to optimize pressure for soil removal and to provide easy access for removal and cleaning.
A 3.0 hp, 1725 RPM motor and pump is horizontally mounted. The pump housing is stainless steel and self-draining. A stainless steel strainer with a removable basket is included. The pre-wash tank features a sloped design to ensure complete tank draining and to minimize soil build-up.
A 3.0 hp, 1725 RPM motor and pump is horizontally mounted. The pump housing is stainless steel and self-draining. A stainless steel strainer with a removable basket is included. The pre-wash tank features a sloped design to ensure complete tank draining and to minimize soil build-up.
Load platform is 12 gauge stainless steel.
Power Rin
Stainless steel pow stricture-free jets m below the wares ar for cleaning.
A 3.0 hp, 1725 R stainless steel housi included. Power ri sloped design to en draining and to min
Machine Dimensions Load
Pre-Wash Tank
Wash Tank
Power Ri
Height
Depth
Length
Height
Depth
Length
Height
Depth
Length
Height
Dep
36” (914.4 mm)
38-1/4” (972 mm)
36” (914.4 mm)
73” (1854 mm)
46” (1168 mm)
36” (914 mm)
73” (1854 mm)
46” (1168 mm)
36” (914 mm)
73” (1854 mm)
46 (1168
Shipping Dimensions Load/Unload (Shipped Together)
Wash Tank
Power Ri
Height
Depth
Length
Height
Depth
Length
Height
Depth
Length
Height
71” (1803 mm)
48” (1219 mm)
60” (1524 mm)
79” (2007 mm)
48” (1219 mm)
60” (1524 mm)
79” (2007 mm)
48” (1219 mm)
60” (1524 mm)
79” (2007 mm)
Weight: 621 lbs (282 kg)
4 of 8
Pre-Wash Tank
Weight: 642 lbs (291 kg)
Weight: 642 lbs (291 kg)
Dep
48 (1219
Weight: 627
Final Rinse
Blower Dryer
Unload
wer rinse arms with mounted above and re easily removable
nse Tank
Rainbow Rinse™ features an arched, removable upper rinse arm that provides superior rinse action while reducing water usage.
A “start/stop” switch is located at the unload end of the machine for the operator’s convenience.
RPM motor with a ing and impeller are inse tank features a nsure complete tank nimize soil build-up.
The final rinse water will cascade back to the power rinse, wash, then the pre-wash tanks.
A stainless steel tunnel incorporated into the discharge section of the machine. The blower dryer keeps the operating personnel from removing the wares before they reach the end of the unload section. An industrial fan-type with a squirrel cage driven by a 0.6 hp direct drive motor dries the wares as they exit the machine.
Unload platform is 14 gauge stainless steel. The drive wheel shaft is supported by two heavy-duty grease-lubricated ball bearings in pillow blocks.
*The Blower Dryer is an option and must be specified at time of order.
nse Tank
Final Rinse
Blower Dryer
Unload
pth
Length
Height
Depth
Length
Height
Depth
Length
Height
Depth
Length
6” 8 mm)
36” (914 mm)
82” (2083 mm)
46” (1168 mm)
36” (914 mm)
88” (2235 mm)
38-1/4” (972 mm)
36” (914 mm)
36” (914 mm)
38-1/4” (972 mm)
42” (1067 mm)
nse Tank
Final Rinse
Blower Dryer
Unload
pth
Length
Height
Depth
Length
Height
Depth
Length
8” 9 mm)
60” (1524 mm)
88” (2235 mm)
48” (1219 mm)
60” (1524 mm)
93” (2362 mm)
48” (1219 mm)
60” (1524 mm)
7 lbs (284 kg)
Weight: 635 lbs (288 kg)
Shipped with Load End
Weight: 504 lbs (229 kg)
5 of 8
Steam 1" [4712mm] 15'-52 14'-6" [4420mm] 13'-6" [4115mm] 7
1" [3840mm] 12'-74
3' [915mm]
3' [913mm]
2
3' [914mm]
3' [914mm]
1" [1945mm] 6'-42 Control Cabinet Door Open
1" [486mm] 1'-78
3' [914mm]
6
1" [972mm] 3'-24
3"[76mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.) 1'-23 4" [375mm]
4
5
3'-05 8" [930mm]
1
1" [724mm] 2'-42
2'-33 4" [705mm]
1" [486mm] 1'-78
9" [229mm]
3
7'-8" [2335mm] 2'-53 8" [745mm] 2'-43 8" [719mm]
3' [914mm]
1" [972mm] 3'-24
1" [1048mm] 3'-54
3'-10" [1168mm]
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)
10" [254mm]
8
10'-8" [3250mm]
3'-6" [1067mm]
18'-6" [5639mm]
CONTROL CABINET
3' [915mm] 3
1" [343mm] 1'-12
4
1" [3843mm] 12'-74
103 4" [273mm]
10'-8" [3250mm] 1
85 8" [219mm]
5
6" [152mm]
6 7'-8" [2335mm]
6'-10" [2084mm] Top of Condensate Duct Pan
POWER RINSE SECTION
87 8" [226mm] 6" [152mm]
WASH SECTION
8
5'-43 4" [1644mm]
PREWASH SECTION 10" [253mm]
6'-1" [1855mm]
7'-6" [2286mm] Optional - Short Doors In The Open Position
8'-8" [2642mm]
Doors In The Open Position
2
7
13'-6" [4115mm] 14'-6" [4420mm] 1" [4712mm] 15'-52
3" [72mm] Deep
18" [457mm] I.D. Square
Steam Vapor Exhaust Duct Minimum 18" Square (Cross Section 324 Sq. In.) Provided by HVAC Contractor
Exhaust Requirements - 1200 CFM
Condensate duct to extended into duct pan.
6'-10" [2083mm] A.F.F.
Condensate duct pan mounted on top of dishmachine electrical section.
6 of 8
Legend 1 - 2" NPT Machine Drain Connection (Floor drain - optional to either end) 2 - Electrical Connection - See Table for Amp Draw 3 - 3/4" NPT Incoming Water Connection 4 - 1-1/2" NPT Steam Connection 5 - 3/4" NPT Wash Section Condensate Return 6 - 3/4" NPT Power Rinse Section Condensate Return 7 - 3/4" NPT Booster Heater Condensate Return 8 - Vent Connection - See Detail
Note: The steam vapor removal system built into the dishmachine consists of a fan that will remove 1200 CFM. A single steam vapor connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 1200 CFM from the area.
Visit us at www.jacksonmsc.com or call us at 1-888-800-5672
9'-0" [2743mm] Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
DIRECTION OF OPERATION
1" [4712mm] 15'-52 14'-6" [4420mm] 13'-6" [4115mm]
7
1" [3840mm] 12'-74
3' [914mm]
3'-10" [1168mm]
2'-43 8" [719mm]
1" [1048mm] 3'-54
7'-8" [2335mm] 2'-53 8" [745mm]
1" [743mm] 2'-54 1" [972mm] 3'-24
1" [486mm] 1'-78
9" [229mm]
10" [254mm]
1" [486mm] 1'-78
10'-8" [3250mm]
3
2'-33 4" [705mm]
3'-05 8" [930mm]
1" [972mm] 3'-24
1" [1944mm] 6'-42 Control Cabinet Door Open
1" [724mm] 2'-42
8
1'-23 4" [375mm] 1
4
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)
2
3'-6" [1067mm]
3' [914mm]
1" [240mm] 92
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)
5
6
3' [914mm]
3' [915mm] 18'-57 8" [5637mm]
3' [914mm]
3' [913mm]
8
4
6
5
7'-8" [2335mm]
9'-0" [2743mm]
8'-8" [2642mm] Door In The Open Position
7'-6" [2286mm] Optional - Short Doors In The Open Position
87 8" [226mm]
6" [152mm] 6" [152mm]
85 8" [219mm]
103 4" [273mm]
1" [343mm] 1'-12
3' [915mm]
3
10" [253mm]
PREWASH SECTION
WASH SECTION
POWER RINSE SECTION
6'-1" [1855mm]
CONTROL CABINET 5'-43 4" [1644mm]
6'-10" [2084mm] Top Of Condensate Duct Pan
2
Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
DIRECTION OF OPERATION
1
10'-8" [3250mm]
7
1" [3843mm] 12'-74 13'-6" [4115mm] 14'-6" [4420mm] 1" [4712mm] 15'-52
Jackson Steam Rackless Conveyor
Jackson Steam Rackless Conveyor with Blower Dryer
Wash, Power Rinse & Final Rinse
Wash, Power Rinse & Final Rinse
Steam tank heat electrical requirements with booster
Steam tank heat electrical requirements with booster
Pump HP
208V
230V
460V
Wash Section
3
8.9
8.2
4.1
Power Rinse Section
3
8.9
8.2
Pre-Wash/Drive/Exhaust
3
11.4
10.4
29.2
26.8
13.6
Totals
Pump HP
208V
230V
460V
Wash Section
3
8.9
8.2
4.1
4.1
Power Rinse Section
3
8.9
8.2
4.1
5.4
Pre-Wash/Drive/Exhaust/Blower Dryer
3
18.6
16.9
8.4
36.4
33.3
16.6
Totals
JFT (steam) comes standard with a 2-point electrical hookup. For other variations, please contact the factory. If water hardness exceeds 3 grains, a water softener is required We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.
7 of 8
LoH2O™
ELECTRICAL An electromechanical control system for increased reliability mounted in a stainlesssteel control cabinet on the front of the machine. A step-down transformer is included to provide 115 volt, 60 cycles, 1 phase operation for controls including solenoid valves, timers, etc. Wiring is 105C, 600-volt thermoplastic insulated wire and routed through UL approved conduit. Low watt density tubular heating elements are mounted inside the wash and power rinse tanks and are easily removable from the exterior of the unit. Heaters are protected by a water level float switch control and a high limit overload. Tank water temperature is maintained by a fast reacting thermostat which will control the heating element.
STEAM Stainless steel tubular steam coils mounted inside the wash and power rinse tanks below the optimum water level and protected by a water level float switch control. An external “Y” strainer and high temperature steam solenoid to regulate the flow of steam through the coil. Tank temperature is controlled and maintained by a fast reacting thermostat that will control the operation of the steam solenoid. A float and thermostatic steam trap to remove the condensate from the coil are included. Steam coils will require a15-30 PSI flowing steam pressure. BOOSTER HEATERS - ELECTRIC An internally mounted 18 kW electric booster heater sized to raise incoming 110˚F (43˚C) water supply to 184˚F (84˚C) minimum for sanitizing rinse. The electric booster heater will have the capacity to heat 58 GPH from 110˚F (43˚C) to 184˚F (84˚C) minimum. The tank is designed for a working pressure 150 PSI and hydrostatically tested at 300 PSI. The heater is complete with all plumbing, including NPT pipe and fittings from inlet and outlet. Electric heating elements are metal sheathed controlled by a close tolerance immersion thermostat. The booster is protected with a high temperature limit switch and low water cut-off. BOOSTER HEATERS - STEAM An internally mounted steam booster heater sized to raise incoming 110˚F (43˚C) water supply to 184˚F (84˚C) minimum for sanitizing rinse. The steam booster heater will have the capacity to heat 58 GPH from 110˚F (43˚C) to184˚F (84˚C) minimum. The tank is designed for a working pressure 150 PSI and hydrostatically tested at 300 PSI. The heater is complete with all plumbing, including NPT pipe and fittings necessary to meet all installation requirements.
DIMENSION REQUIREMENTS
STEAM REQUIREMENTS
Wall Clearance (Minimum)
3” (19 mm) 25”H x 30”W (635 mm x 762 mm)
Inside Clearance
OPERATING CAPACITY Dishes per Hour - Belt Speed 5.3 FPM (1.6 MPM)
8,772
Dishes per Hour - Belt Speed 6.7 FPM (2.0 MPM)
11,094
15-30
Consumption @110˚F Incoming Water Temp (Tanks only)
200 lbm/hr
Consumption @110˚F Incoming Water Temp (70° F Rise Booster)
68 lbm/hr
Consumption with blower dryer
34 lbm/hr
WATER REQUIREMENTS Inlet Tempterature Gallons per Hour
OPERATING TEMPERATURES
110˚F (43˚C) 58 gal (219.5 L)
Pre-Wash (Recommended)
140˚F (60˚C)
Waterline Size IPS (Minimum-inches)
3/4” (19 mm)
Wash (Minimum)
152˚F (67˚C)
Drainline Size IPS (Minimum-Inches)
2” (51 mm)
Rinse (Minimum)
162˚F (72˚C)
Flow Pressure (PSIG)
Final Rinse
184˚F (84˚C)
TANK CAPACITY
MOTORS
15
Pre-Wash Tank
36 gal (136 L)
Pre-Wash Pump Motor
3.0 hp
Wash Tank
36 gal (136 L)
Wash Pump Motor
3.0 hp
Power Rinse Tank
36 gal (136 L)
Power Rinse Pump Motor
3.0 hp
Conveyor Drive Motor
1/4 hp
HOW TO SPECIFY: LoH2O JFT
8 of 8
Steam Flow Pressure (PSIG)
PUMP CAPACITY Pre-Wash Pump
260 GPM (984 LPM)
Wash Pump
260 GPM (984 LPM)
Power Rinse Pump
260 GPM (984 LPM)
SHIPPING ADDRESS
MAILING ADDRESS
Tel: 1-888-800-5672
www.jacksonmsc.com
6209 North U.S. Highway 25E
P.O. Box 1060
Fax: 606-523-1799
07610-003-94-17 (07/30/12)
Gray, KY 40734
Barbourville, KY 40906
[email protected]