Options Blower dryer Additional wash section Additional load module Additional unload module 25’ (8m) wash down hose - mounted Electrical connection with circuit breakers Dual point electrical connection Low profile doors Flanged feet Multiple conveyor peg choice Drain at load or unload end Prison Package

Standard Features • Uses 58 gallons (219.5 liters) of water per hour with sanitizing hot water rinse • All tanks and hoods constructed from 16 gauge 304 stainless steel with a No. 3 finish and heliarced welded • Stainless steel frame, legs and feet • Two tank rackless conveyor shall have a maximum capacity of 11,094 dishes per hour at a belt speed of 6.7 (2.0 M) feet per minute. At 5.3 feet (1.6 M) per minute capacity will be 8,772 dishes per hour • Belt width of 29” (737 mm) and a maximum clearance of 25” (635 mm) throughout the machine • Rear enclosure panels, hood and doors are stainless steel and double-wall insulated to reduce heat dissipation, outside surface temperatures, and noise pollution • Insulated access doors for easy access, cleaning and servicing • Sloped tank(s) design to increase visibility and accessibility for cleaning as well as ensure complete tank draining • Heated power rinse zone uses fresh rinse water a second time to provide pristine results

• Exclusive Rainbow Rinse™ features an arched, removable upper rinse arm that provides superior rinse action while reducing water usage • A sequential digital temperature readout of each tank housed in the door of the electrical control panel. The readouts will constantly display the temperature of the pre-wash, wash, power rinse and final rinse in 5 second intervals • A ball valve in the drain line of each tank and interconnected to a common machine drain connection at the load end of the machine • Each tank will be automatically filled and maintained by a dual water level float. Water will be automatically added to the machine when required • Block manifold wash arms are easy to remove, clean, and replace with nonclogging convex wash arm jet • Large, removable scrap screens • Pre-wash includes a deep-well removable scrap basket in addition to a large removable scrap screen • Self draining stainless steel pumps, impellers, and housings are readily accessible and serviceable • Service access from front of machine

SHIPPING ADDRESS

MAILING ADDRESS

Tel: 1-888-800-5672

6209 North U.S. Highway 25E

P.O. Box 1060

Fax: 606-523-1799

Gray, KY 40734

Barbourville, KY 40906

[email protected]

• Conveyor belt drive operates at two speeds and is protected by an overload safety device and an automatic shut-down actuator • Each door is equipped with a safety switch. If a door is opened during operation the switch will immediately shut down the pumps and belt • Operator activated start-stop switches on both the load and unload ends and the control panel • Belt tension adjustment • Removable insulated panels to enclose the unit down to the base frame on both the front and rear of the machine • A single, built-in 18” square (457 mm x 457 mm) indirect vent connection with a 0.19 hp exhaust fan mounted in a cleanable cross duct on the machine for exhaust steam removal and indirect vent connection • 3” minimum wall clearance

www.jacksonmsc.com

1 of 8

1'-23 4" [375mm] 3" [76mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)

5

2 1

4

3 3' [914mm]

3' [914mm]

3' [914mm]

3' [914mm]

3' [915mm]

1" [1943mm] 6'-42 Control Cabinet Door Open

1" [972mm] 3'-24

6

3' [914mm]

7

12'-7" [3836mm]

2'-33 4" [706mm]

2'-53 8" [746mm] 2'-43 8" [721mm] 1" [234mm] 94

1" [743mm] 2'-54

1" [1048mm] 3'-54 1" [971mm] 3'-24

3'-10" [1168mm]

1" [486mm] 1'-78

1" [4712mm] 15'-52 13'-6" [4115mm]

9" [229mm] 1" [486mm] 1'-78

Electric

3" [76mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)

3'-6" [1067mm]

18'-6" [5639mm]

DIRECTION OF OPERATION

3" [72mm] Deep

3' [914mm] 1" [129mm] 58 TYPICAL 6

13'-6" [4115mm] 1" [4712mm] 15'-52

Steam Vapor Exhaust Duct Minimum 18" Square (Cross Section 324 Sq. In.) Provided by HVAC Contractor

Exhaust Requirements - 1200 CFM

Condensate duct to extended into duct pan.

Condensate duct pan mounted on top of dishmachine electrical section.

Legend 1 - 2" NPT Machine Drain Connection (Floor drain - optional to either end) 2 - *Wash Tank Electrical Connection 3 - *Rinse Tank Electrical Connection 4 - *Booster Heater Electrical Connection 5 - *Motor Controls Electrical Connection 6 - 3/4" NPT Incoming Water Connection 7 - Vent Connection - See Detail *See Table For Amp Draw

Note: The steam vapor removal system built into the dishmachine consists of a fan that will remove 1200 CFM. A single steam vapor connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 1200 CFM from the area.

2 of 8

Visit us at www.jacksonmsc.com or call us at 1-888-800-5672

6'-10" [2083mm] Top of Exhaust Fan Housing

7

5'-43 4" [1644mm]

5

103 4" [273mm]

1

6'-10" [2083mm] A.F.F.

4

6" [152mm]

12'-7" [3836mm]

18" [457mm] I.D. Square

3

6" [152mm]

87 8" [226mm]

3' [914mm]

6'-1" [1855mm]

7'-6" [2286mm] Optional - Short Doors In The Open Position

8'-8" [2642mm] Doors In The Open Postion

2

9'-0" [2743mm] Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]

Power Connections Inside Control Panel

1" [743mm] 2'-54

3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)

1" [234mm] 94

5

3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)

2 1

4

3

3'-6" [1067mm]

3' [915mm]

3' [914mm]

3' [914mm]

3' [914mm]

1" [1048mm] 3'-54

2'-53 8" [746mm] 2'-43 8" [721mm]

3'-10" [1168mm]

7

1" [971mm] 3'-24

12'-7" [3836mm]

6

1'-23 4" [375mm]

1" [486mm] 1'-78

9" [229mm]

13'-6" [4115mm]

2'-33 4" [706mm]

3' [914mm]

1" [972mm] 3'-24

3' [914mm]

18'-6" [5639mm]

DIRECTION OF OPERATION

3' [914mm] 6" [152mm]

1" [129mm] 58 Typical

1 12'-7" [3836mm] 13'-6" [4115mm]

6

1" [4711mm] 15'-52

Jackson Electric Rackless Conveyor

Jackson Electric Rackless Conveyor with Blower Dryer

Wash, Power Rinse & Final Rinse

Wash, Power Rinse & Final Rinse

Electrical requirements with booster*

Electrical requirements with booster* Heater kW

Pump HP

Wash Heater & Pump Section

24

3

75.5

63.5

31.8

Power Rinse Heater & Pump Section

33

3

100.5

84.3

42.1

-

3

11.4

10.4

5.4

Pre-Wash Pump, Motors & Controls Booster*

8'-8" [2642mm] Doors In The Open Position

2

7'-6" [2286mm] Optional - Short Doors In The Open Position

3

7

6'-1" [1855mm]

4

3' [914mm] 103 4" [273mm]

5'-43 4" [1644mm]

6'-10" [2083mm] Top of Exhaust Fan Housing

5

9'-0" [2743mm] Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]

Power Connections Inside Control Panel

6" [152mm] 87 8" [226mm]

1" [1943mm] 6'-42 Control Cabinet Door Open

1" [486mm] 1'-78

1" [4712mm] 15'-52

18†

Totals *70° F rise booster †208V booster is 17.2kW

208V

230V

Heater kW

Pump HP

Wash Heater & Pump Section

24

3

75.5

63.5

31.8

Power Rinse Heater & Pump Section

33

3

100.5

84.3

42.1

Pre-Wash Pump, Motors, Blower Dryer Heater & Controls

9

3

43.6

39.4

19.9

460V

47.7

41.5

20.8

Booster*

235.1

199.7

100.1

Totals

18†

208V

230V

460V

47.7

41.5

20.8

267.3

228.7

114.6

*70° F rise booster †208V booster is 17.2kW

JFT (electric) comes standard with 4-point electrical hookup. For other variations, please contact the factory. If water hardness exceeds 3 grains, a water softener is required We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.

3 of 8

Load

Pre-Wash Tank

Wash Tank

A “start/stop” switch is located at the load end of the machine for the operator’s convenience.

The pre-wash tank features a stainless steel manifold system with stricturefree jets to optimize pressure for soil removal and to provide easy access for removal and cleaning.

The wash tank features a stainless steel manifold system with stricture-free jets to optimize pressure for soil removal and to provide easy access for removal and cleaning.

A 3.0 hp, 1725 RPM motor and pump is horizontally mounted. The pump housing is stainless steel and self-draining. A stainless steel strainer with a removable basket is included. The pre-wash tank features a sloped design to ensure complete tank draining and to minimize soil build-up.

A 3.0 hp, 1725 RPM motor and pump is horizontally mounted. The pump housing is stainless steel and self-draining. A stainless steel strainer with a removable basket is included. The pre-wash tank features a sloped design to ensure complete tank draining and to minimize soil build-up.

Load platform is 12 gauge stainless steel.

Power Rin

Stainless steel pow stricture-free jets m below the wares ar for cleaning.

A 3.0 hp, 1725 R stainless steel housi included. Power ri sloped design to en draining and to min

Machine Dimensions Load

Pre-Wash Tank

Wash Tank

Power Ri

Height

Depth

Length

Height

Depth

Length

Height

Depth

Length

Height

Dep

36” (914.4 mm)

38-1/4” (972 mm)

36” (914.4 mm)

73” (1854 mm)

46” (1168 mm)

36” (914 mm)

73” (1854 mm)

46” (1168 mm)

36” (914 mm)

73” (1854 mm)

46 (1168

Shipping Dimensions Load/Unload (Shipped Together)

Wash Tank

Power Ri

Height

Depth

Length

Height

Depth

Length

Height

Depth

Length

Height

71” (1803 mm)

48” (1219 mm)

60” (1524 mm)

79” (2007 mm)

48” (1219 mm)

60” (1524 mm)

79” (2007 mm)

48” (1219 mm)

60” (1524 mm)

79” (2007 mm)

Weight: 621 lbs (282 kg)

4 of 8

Pre-Wash Tank

Weight: 642 lbs (291 kg)

Weight: 642 lbs (291 kg)

Dep

48 (1219

Weight: 627

Final Rinse

Blower Dryer

Unload

wer rinse arms with mounted above and re easily removable

nse Tank

Rainbow Rinse™ features an arched, removable upper rinse arm that provides superior rinse action while reducing water usage.

A “start/stop” switch is located at the unload end of the machine for the operator’s convenience.

RPM motor with a ing and impeller are inse tank features a nsure complete tank nimize soil build-up.

The final rinse water will cascade back to the power rinse, wash, then the pre-wash tanks.

A stainless steel tunnel incorporated into the discharge section of the machine. The blower dryer keeps the operating personnel from removing the wares before they reach the end of the unload section. An industrial fan-type with a squirrel cage driven by a 0.6 hp direct drive motor dries the wares as they exit the machine.

Unload platform is 14 gauge stainless steel. The drive wheel shaft is supported by two heavy-duty grease-lubricated ball bearings in pillow blocks.

*The Blower Dryer is an option and must be specified at time of order.

nse Tank

Final Rinse

Blower Dryer

Unload

pth

Length

Height

Depth

Length

Height

Depth

Length

Height

Depth

Length

6” 8 mm)

36” (914 mm)

82” (2083 mm)

46” (1168 mm)

36” (914 mm)

88” (2235 mm)

38-1/4” (972 mm)

36” (914 mm)

36” (914 mm)

38-1/4” (972 mm)

42” (1067 mm)

nse Tank

Final Rinse

Blower Dryer

Unload

pth

Length

Height

Depth

Length

Height

Depth

Length

8” 9 mm)

60” (1524 mm)

88” (2235 mm)

48” (1219 mm)

60” (1524 mm)

93” (2362 mm)

48” (1219 mm)

60” (1524 mm)

7 lbs (284 kg)

Weight: 635 lbs (288 kg)

Shipped with Load End

Weight: 504 lbs (229 kg)

5 of 8

Steam 1" [4712mm] 15'-52 14'-6" [4420mm] 13'-6" [4115mm] 7

1" [3840mm] 12'-74

3' [915mm]

3' [913mm]

2

3' [914mm]

3' [914mm]

1" [1945mm] 6'-42 Control Cabinet Door Open

1" [486mm] 1'-78

3' [914mm]

6

1" [972mm] 3'-24

3"[76mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.) 1'-23 4" [375mm]

4

5

3'-05 8" [930mm]

1

1" [724mm] 2'-42

2'-33 4" [705mm]

1" [486mm] 1'-78

9" [229mm]

3

7'-8" [2335mm] 2'-53 8" [745mm] 2'-43 8" [719mm]

3' [914mm]

1" [972mm] 3'-24

1" [1048mm] 3'-54

3'-10" [1168mm]

3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)

10" [254mm]

8

10'-8" [3250mm]

3'-6" [1067mm]

18'-6" [5639mm]

CONTROL CABINET

3' [915mm] 3

1" [343mm] 1'-12

4

1" [3843mm] 12'-74

103 4" [273mm]

10'-8" [3250mm] 1

85 8" [219mm]

5

6" [152mm]

6 7'-8" [2335mm]

6'-10" [2084mm] Top of Condensate Duct Pan

POWER RINSE SECTION

87 8" [226mm] 6" [152mm]

WASH SECTION

8

5'-43 4" [1644mm]

PREWASH SECTION 10" [253mm]

6'-1" [1855mm]

7'-6" [2286mm] Optional - Short Doors In The Open Position

8'-8" [2642mm]

Doors In The Open Position

2

7

13'-6" [4115mm] 14'-6" [4420mm] 1" [4712mm] 15'-52

3" [72mm] Deep

18" [457mm] I.D. Square

Steam Vapor Exhaust Duct Minimum 18" Square (Cross Section 324 Sq. In.) Provided by HVAC Contractor

Exhaust Requirements - 1200 CFM

Condensate duct to extended into duct pan.

6'-10" [2083mm] A.F.F.

Condensate duct pan mounted on top of dishmachine electrical section.

6 of 8

Legend 1 - 2" NPT Machine Drain Connection (Floor drain - optional to either end) 2 - Electrical Connection - See Table for Amp Draw 3 - 3/4" NPT Incoming Water Connection 4 - 1-1/2" NPT Steam Connection 5 - 3/4" NPT Wash Section Condensate Return 6 - 3/4" NPT Power Rinse Section Condensate Return 7 - 3/4" NPT Booster Heater Condensate Return 8 - Vent Connection - See Detail

Note: The steam vapor removal system built into the dishmachine consists of a fan that will remove 1200 CFM. A single steam vapor connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 1200 CFM from the area.

Visit us at www.jacksonmsc.com or call us at 1-888-800-5672

9'-0" [2743mm] Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]

DIRECTION OF OPERATION

1" [4712mm] 15'-52 14'-6" [4420mm] 13'-6" [4115mm]

7

1" [3840mm] 12'-74

3' [914mm]

3'-10" [1168mm]

2'-43 8" [719mm]

1" [1048mm] 3'-54

7'-8" [2335mm] 2'-53 8" [745mm]

1" [743mm] 2'-54 1" [972mm] 3'-24

1" [486mm] 1'-78

9" [229mm]

10" [254mm]

1" [486mm] 1'-78

10'-8" [3250mm]

3

2'-33 4" [705mm]

3'-05 8" [930mm]

1" [972mm] 3'-24

1" [1944mm] 6'-42 Control Cabinet Door Open

1" [724mm] 2'-42

8

1'-23 4" [375mm] 1

4

3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)

2

3'-6" [1067mm]

3' [914mm]

1" [240mm] 92

3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)

5

6

3' [914mm]

3' [915mm] 18'-57 8" [5637mm]

3' [914mm]

3' [913mm]

8

4

6

5

7'-8" [2335mm]

9'-0" [2743mm]

8'-8" [2642mm] Door In The Open Position

7'-6" [2286mm] Optional - Short Doors In The Open Position

87 8" [226mm]

6" [152mm] 6" [152mm]

85 8" [219mm]

103 4" [273mm]

1" [343mm] 1'-12

3' [915mm]

3

10" [253mm]

PREWASH SECTION

WASH SECTION

POWER RINSE SECTION

6'-1" [1855mm]

CONTROL CABINET 5'-43 4" [1644mm]

6'-10" [2084mm] Top Of Condensate Duct Pan

2

Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]

DIRECTION OF OPERATION

1

10'-8" [3250mm]

7

1" [3843mm] 12'-74 13'-6" [4115mm] 14'-6" [4420mm] 1" [4712mm] 15'-52

Jackson Steam Rackless Conveyor

Jackson Steam Rackless Conveyor with Blower Dryer

Wash, Power Rinse & Final Rinse

Wash, Power Rinse & Final Rinse

Steam tank heat electrical requirements with booster

Steam tank heat electrical requirements with booster

Pump HP

208V

230V

460V

Wash Section

3

8.9

8.2

4.1

Power Rinse Section

3

8.9

8.2

Pre-Wash/Drive/Exhaust

3

11.4

10.4

29.2

26.8

13.6

Totals

Pump HP

208V

230V

460V

Wash Section

3

8.9

8.2

4.1

4.1

Power Rinse Section

3

8.9

8.2

4.1

5.4

Pre-Wash/Drive/Exhaust/Blower Dryer

3

18.6

16.9

8.4

36.4

33.3

16.6

Totals

JFT (steam) comes standard with a 2-point electrical hookup. For other variations, please contact the factory. If water hardness exceeds 3 grains, a water softener is required We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.

7 of 8

LoH2O™

ELECTRICAL An electromechanical control system for increased reliability mounted in a stainlesssteel control cabinet on the front of the machine. A step-down transformer is included to provide 115 volt, 60 cycles, 1 phase operation for controls including solenoid valves, timers, etc. Wiring is 105C, 600-volt thermoplastic insulated wire and routed through UL approved conduit. Low watt density tubular heating elements are mounted inside the wash and power rinse tanks and are easily removable from the exterior of the unit. Heaters are protected by a water level float switch control and a high limit overload. Tank water temperature is maintained by a fast reacting thermostat which will control the heating element.

STEAM Stainless steel tubular steam coils mounted inside the wash and power rinse tanks below the optimum water level and protected by a water level float switch control. An external “Y” strainer and high temperature steam solenoid to regulate the flow of steam through the coil. Tank temperature is controlled and maintained by a fast reacting thermostat that will control the operation of the steam solenoid. A float and thermostatic steam trap to remove the condensate from the coil are included. Steam coils will require a15-30 PSI flowing steam pressure. BOOSTER HEATERS - ELECTRIC An internally mounted 18 kW electric booster heater sized to raise incoming 110˚F (43˚C) water supply to 184˚F (84˚C) minimum for sanitizing rinse. The electric booster heater will have the capacity to heat 58 GPH from 110˚F (43˚C) to 184˚F (84˚C) minimum. The tank is designed for a working pressure 150 PSI and hydrostatically tested at 300 PSI. The heater is complete with all plumbing, including NPT pipe and fittings from inlet and outlet. Electric heating elements are metal sheathed controlled by a close tolerance immersion thermostat. The booster is protected with a high temperature limit switch and low water cut-off. BOOSTER HEATERS - STEAM An internally mounted steam booster heater sized to raise incoming 110˚F (43˚C) water supply to 184˚F (84˚C) minimum for sanitizing rinse. The steam booster heater will have the capacity to heat 58 GPH from 110˚F (43˚C) to184˚F (84˚C) minimum. The tank is designed for a working pressure 150 PSI and hydrostatically tested at 300 PSI. The heater is complete with all plumbing, including NPT pipe and fittings necessary to meet all installation requirements.

DIMENSION REQUIREMENTS

STEAM REQUIREMENTS

Wall Clearance (Minimum)

3” (19 mm) 25”H x 30”W (635 mm x 762 mm)

Inside Clearance

OPERATING CAPACITY Dishes per Hour - Belt Speed 5.3 FPM (1.6 MPM)

8,772

Dishes per Hour - Belt Speed 6.7 FPM (2.0 MPM)

11,094

15-30

Consumption @110˚F Incoming Water Temp (Tanks only)

200 lbm/hr

Consumption @110˚F Incoming Water Temp (70° F Rise Booster)

68 lbm/hr

Consumption with blower dryer

34 lbm/hr

WATER REQUIREMENTS Inlet Tempterature Gallons per Hour

OPERATING TEMPERATURES

110˚F (43˚C) 58 gal (219.5 L)

Pre-Wash (Recommended)

140˚F (60˚C)

Waterline Size IPS (Minimum-inches)

3/4” (19 mm)

Wash (Minimum)

152˚F (67˚C)

Drainline Size IPS (Minimum-Inches)

2” (51 mm)

Rinse (Minimum)

162˚F (72˚C)

Flow Pressure (PSIG)

Final Rinse

184˚F (84˚C)

TANK CAPACITY

MOTORS

15

Pre-Wash Tank

36 gal (136 L)

Pre-Wash Pump Motor

3.0 hp

Wash Tank

36 gal (136 L)

Wash Pump Motor

3.0 hp

Power Rinse Tank

36 gal (136 L)

Power Rinse Pump Motor

3.0 hp

Conveyor Drive Motor

1/4 hp

HOW TO SPECIFY: LoH2O JFT

8 of 8

Steam Flow Pressure (PSIG)

PUMP CAPACITY Pre-Wash Pump

260 GPM (984 LPM)

Wash Pump

260 GPM (984 LPM)

Power Rinse Pump

260 GPM (984 LPM)

SHIPPING ADDRESS

MAILING ADDRESS

Tel: 1-888-800-5672

www.jacksonmsc.com

6209 North U.S. Highway 25E

P.O. Box 1060

Fax: 606-523-1799

07610-003-94-17 (07/30/12)

Gray, KY 40734

Barbourville, KY 40906

[email protected]