STAPLER FOLDER DBM-120 Sheet by Sheet INSTALLATION MANUAL Specialized person only

TO SERVICING PERSONNEL Do not leave this Installation Manual at the installation site after installation. Furthermore, do not leave tools used for the installation, at the installation site. Retain this Installation Manual for future reference as it will be needed for subsequent maintenance such as relocation.

TABLE OF CONTENTS 1.

2.

Points to Note in Installation .......................... 1 1-1.

Before Installing ....................................... 1

1-2.

Installation Location ................................. 1

1-3.

Power Supply ........................................... 1

1-4.

Output Connector .................................... 1

Installation Procedure ..................................... 2 2-1.

Standard Accessories .............................. 2

2-2.

Connecting the DSF-2000 ....................... 4

2-3.

Attaching the Accessories ....................... 6

2-4.

Connecting the Earth Wire ....................... 7

2-5.

Connecting the Power Supply ................. 7

2-6.

Checking the Installation Position ............ 7

2-7.

When Connecting the DBM-120T (Checking the Product Number) .............. 8

2-8.

When Connecting the DBM-120T (Connecting the Connecting Cable) ......... 8

1. POINTS TO NOTE IN INSTALLATION 1-1. Before Installing Turn off the unit, then unplug its power cord from the AC outlet. Make sure that the power supply voltage and frequency in your area match the power requirements indicated on the main name plate of the unit.

1-2. Installation Location Install the equipment in a place where the floor is strong enough to bear the mass of the unit, which is as follows: 91 kg (200.44 lb)

Requirements for installation space are as follows: Width × Depth = 1280 × 550 mm (50.39 × 21.65")

Install the equipment in a horizontal and stable position. Do not install the equipment near heaters or other heat-emitting appliances. Install and use the equipment in an environment: – where the temperature range is between 5 and 35°C, – where the humidity range is between 20 and 85% RH (no dew condensation), – which is not subject to direct sunlight, – which is subject to little or no vibration,

– – – –

where there are no harmful chemicals, which is reasonably free from dust, which is free from air-borne salt, and where the equipment will not be exposed to water.

1-3. Power Supply This equipment shall be installed near the socket-outlet where the plug on the power supply cord is easily accessible. When you power other appliances from the same AC outlet, make sure that the combined power consumption does not exceed the power supply capacity.

1-4. Output Connector Connector for connecting cable: DC +5 V Max.

Connector for connecting cable

D-PORT connector: DC +6 V Max. D-PORT connectors

1

2. INSTALLATION PROCEDURE 2-1. Standard Accessories Check that you have the following parts. q

w

t

y

!1

!2

!5

u

i

!7

@1

STAPLER FOLDER

STAPLER FOLDER

DBM-120 Sheet by Sheet

DBM-120 Sheet by Sheet

INSTRUCTION MANUAL

INSTALLATION MANUAL

Please store th s manual in a safe place for future reference.

r

o

!3

!6

@0

2

e

Specialized person only

!0

!4

!8

!9

2. INSTALLATION PROCEDURE

No.

Name

Qty.

No.

Name

Qty.

q

Saddle-stapled paper stacker

1

!2

Connecting cable 2

1

w

Side-stapled paper stacker

1

!3

Power cord (only 220 to 240 V AC)

1

e

Belt stacker

1

!4

Power cord (only 120 V AC)

1

r

Paper guide roller unit

1

!5

Earth wire 1

1

t

Corner-stapling side jogger (right)

1

!6

Earth wire 2

1

y

Tool for moving clincher

1

!7

Cable clamp

3

u

Guide unit

2

!8

Connecting plate

1

i

Paper holding guide unit

1

!9

Screw (MSKW5 × 10)

4

o

Paper holder

1

@0

Instruction manual

1

!0

Corner-stapling guide

1

@1

Installation manual

1

!1

Connecting cable 1

1

3

2. INSTALLATION PROCEDURE

2-2. Connecting the DSF-2000

1

Release the locks securing the bottom plate of this unit and movable unit together (2 each at the front and back). Fixing plate

Loosen the two screws of the fixing plate, and move the fixing plate down and secure it. NOTE : Be sure to complete above work before turning on the power, or the unit may damage.

2

Temporarily secure the connecting plate provided to the DBM-120 cabinet.

Movable unit

DBM-120 Sheet by Sheet

> Connecting plate !8 ............................................ 1 Screw (MSKW5 × 10) !9 ................................... 2

DBM-120 cabinet Connecting plate

3

Temporarily secure the connecting plate to the DSF-2000.

Connecting plate

Screws

DSF-2000 Screws

> Screw (MSKW5 × 10) !9 ................................... 2

4 5

Tighten the screws temporarily secured in step 2, and secure the connecting plate. Check that the distance between the paper in-feed slot of this unit and the paper ejection guide of the DSF-2000 is 3 to 7 mm (0.12" to 0.28").

DBM-120 Sheet by Sheet Paper ejection guide of DSF-2000 Guide

NOTE : As the above range will not be satisfied if the ground is not flat, check that the ground is flat. 3 to 7 mm (0.12" to 0.28")

4

2. INSTALLATION PROCEDURE

6

Check that the paper in-feed slot of this unit and the center of the paper ejection guide of the DSF-2000 are of the same height.

DBM-120 Sheet by Sheet Paper ejection guide of DSF-2000 Guide

NOTE : As the above range will not be satisfied if the ground is not flat, check that the ground is flat.

7

Insert one plug of the connecting cable 1 provided into D-PORT connector 2 of the DSF-2000, and the other end into D-PORT connector 1 of this unit. NOTE : Use the DUPLO connecting cable (marked STYLE 20276) only.

D-PORT connector 2



Connecting cable 1

D-PORT connector 1 Connecting cable 1

> Connecting cable 1 !1 ........................................ 1

5

2. INSTALLATION PROCEDURE

2-3. Attaching the Accessories NOTE : When connecting the DBM-120T, refer to its installation manual.

Attach the following q to u parts to this unit. q Side-stapled paper stacker ................................... 1 w Guide unit ............................................................ 2 e Paper holding guide unit ...................................... 1 r Paper holder ......................................................... 1 t Belt stacker .......................................................... 1 y Paper guide roller unit ......................................... 1 u Saddle-stapled paper stacker ............................... 1

1

For q, insert the screws attached to this unit into the holes and tighten. Place w and e on the side-stapled paper stacker as shown in the figure. For r, adjust the Z collars attached to this unit to the holes and insert.

w Guide units e Paper holding guide unit q Side-stapled paper stacker

r Paper holder

2

6

For t, adjust the Z collars to the holes on this unit and insert, and then insert the plug of the cable into the connector of this unit. For y, adjust the shaft to the hole on this unit, insert, and rotate it by 90°. For u, adjust the Z collars attached to the belt stacker to the holes and insert.

y Paper guide roller unit u Saddle-stapled paper stacker

t Belt stacker

2. INSTALLATION PROCEDURE

2-4. Connecting the Earth Wire

1

Connect the earth wires 1 and 2 provided to this unit and the DSF-2000. Earth wire 1

DSF-2000

Earth wire 2

DBM-120 Sheet by Sheet

DSF-2000

DBM-120 Sheet by Sheet

2-5. Connecting the Power Supply

1

Insert the power plug into the outlet.

NOTE : Move the DBM-120 Sheet by Sheet unit to and fro when changing the paper size. Move aside the power cord so that it does not touch the DBM-120 Sheet by Sheet at this time.

2-6. Checking the Installation Position

2

Turn on the power supply of this unit, and set to the A3 size. Refer to “6-1. Basic Operation” in the instruction manual of this unit for details on setting the paper size. Adjust at the long holes of the connecting plate so that the notch of the paper ejection guide of the DSF-2000 aligns with the A3 mark on the indication label of this unit, and tighten the screws temporarily secured in step 3 of the section “2-2.” to secure the connecting plate and DSF-2000.

Notch of paper ejection guide of DSF-2000

A3

1

Indication label of DBM-120 Sheet by Sheet

7

2. INSTALLATION PROCEDURE

2-7. When Connecting the DBM-120T (Checking the Product Number)

1

Check the product number of the DBM-120T to be connected. If the product number is “0009XXXXX” or less, the DBM-120T will not operate normally.



Product number

2-8. When Connecting the DBM-120T (Connecting the Connecting Cable)

1

When connecting the DBM-120T, use the connecting cable 2 provided. Insert one plug of the connecting cable 2 into D-PORT connector 2 of this unit, and the other end into D-PORT connector 1 of the DBM-120T.





D-PORT connector 1 D-PORT connector 2 Connecting cable 2

Connecting cable 2

NOTE : Use the DUPLO connecting cable (marked STYLE 20276) only. > Connecting cable 2 !2 ........................................ 1

2

Fix the connecting cable 2 to the DBM-120/120T cabinets using the cable clamps provided as shown in the figure. > Cable clamp !7 ................................................... 3

DBM-120 cabinet

Cable clamps

DBM-120T cabinet

This ends the installation procedure.