Duplo DSF-2000 Sheet Feeder
Installation Manual
Provided By
http://www.MyBinding.com
http://www.MyBindingBlog.com
SHEET FEEDER DSF-2000 INSTALLATION MANUAL Specialized person only
TO SERVICING PERSONNEL Do not leave this Installation Manual at the installation site after installation. Furthermore, do not leave tools used for the installation, at the installation site. Retain this Installation Manual for future reference as it will be needed for subsequent maintenance such as relocation.
TABLE OF CONTENTS 1.
Points to Note in Installation .......................... 1 1-1.
Before Installing ....................................... 1
1-2.
Installation Location ................................. 1
1-3.
Power Supply ........................................... 1
2.
Standard Accessories ..................................... 2
3.
Installation of DSF-2000 .................................. 4 3-1.
Preparations for DSF-2000 ...................... 4
3-2.
Connecting the Power Supply ................. 5
3-3.
Selecting the Downstream Processing Unit .......................................................... 6
1. POINTS TO NOTE IN INSTALLATION 1-1. Before Installing Turn off the unit, then unplug its power cord from the AC outlet. Make sure that the power supply voltage and frequency in your area match the power requirements indicated on the main name plate of the unit.
1-2. Installation Location Install the equipment in a place where the floor is strong enough to bear the mass of the unit, which is as follows: 136 kg (299.56 lb)
Requirements for installation space are as follows: Width × Depth = 1100 × 750 mm (43.31 × 29.53")
Install the equipment in a horizontal and stable position. Do not install the equipment near heaters or other heat-emitting appliances. Install and use the equipment in an environment: – where the temperature range is between 5 and 35°C, – where the humidity range is between 20 and 85% RH (no dew condensation), – which is not subject to direct sunlight, – which is subject to little or no vibration,
– – – –
where there are no harmful chemicals, which is reasonably free from dust, which is free from air-borne salt, and where the equipment will not be exposed to water.
1-3. Power Supply This equipment shall be installed near the socket-outlet where the plug on the power supply cord is easily accessible. When you power other appliances from the same AC outlet, make sure that the combined power consumption does not exceed the power supply capacity.
1
2. STANDARD ACCESSORIES Confirm that the following parts are provided. q
w
r
t
o
y
u
!0
!5
SHEET FEEDER
DSF-2000
DSF-2000
INSTRUCTION MANUAL
INSTALLATION MANUAL Specialized person only
2
i
!1
!6
SHEET FEEDER
e
!2
!3
!4
2. STANDARD ACCESSORIES
No.
Name
Qty.
No.
Name
Qty.
q
Bridge
1
o
Power cord (only 120 V AC)
1
w
Upper bridge guide
1
!0
Connecting plate
1
e
Lower bridge guide
1
!1
Auxiliary paper feed plate A
1
r
Front bracket
1
!2
Screw (HSKW5 × 12)
6
t
Rear bracket
1
!3
Screw (MSKW4 × 8)
4
y
Auxiliary stack guide A
1
!4
Screw (MSKW3 × 6)
4
u
Stack guide B
3
!5
Instruction manual
1
i
Power cord (only 220 to 240 V AC)
1
!6
Installation manual
1
3
3. INSTALLATION OF DSF-2000 3-1. Preparations for DSF-2000
1
Attach the auxiliary paper feed plate A. Refer to “15. STACKING PAPER ON THE PAPER FEEDER A AND ADJUSTING PAPER FEED” in the instruction manual. Auxiliary paper feed plate A
2
Attach the front bracket, rear bracket, upper bridge guide, and lower bridge guide to the bridge.
Bridge
q Attach the front and rear brackets to the bridge using the screws (MSKW4 × 8) provided. Rear bracket
Front bracket
w Attach the upper and lower bridge guides to the front and rear brackets using the screws (MSKW3 × 6) provided.
Upper bridge guide
Lower bridge guide
4
3. INSTALLATION OF DSF-2000
3
Attach the bridge. Hook the holes on the bridge to the stepped collars on this unit, and secure the bridge using the four screws (HSKW5 × 12) provided. To avoid the parts of this unit, attach the bridge as shown in the figure. Connect the bridge cable to the connector of this unit. Stepped collars
Parts of this unit
Screws (HSKW5 × 12)
Bridge
Bridge cable
4
Attach the connecting plate to the DSF-2000 as shown in the figure. (Use the screws (HSKW5 × 12) provided.)
Connecting plate
5
Adjust the angle of the ejection guide. Normally use horizontally (in the shipped state). After installing, adjust only if necessary according to the using state.
When connecting the downstream processing unit, refer to its installation manual, instruction manual, and the installation manual for the cabinet.
3-2. Connecting the Power Supply Insert the power cord plug of the DSF-2000 into the outlet.
5
3. INSTALLATION OF DSF-2000
3-3. Selecting the Downstream Processing Unit Set the downstream processing unit to be connected on the maintenance menu. Display (LCD)
Stop button
Start button Power ON indicator Clear
Escape
button
button Jog dial
Function
button
1 2
Turn on the power of this unit. Enter the maintenance menu. Press the escape button once on the initial screen of the control panel. Turn the jog dial by three clicks towards the right, and press the clear button once. A beep will be sounded. Turn the jog dial by 5 clicks towards the left, and press the clear button once. Two beeps are sounded and “Maintenance Menu” will be displayed. Press the jog dial here to enter the maintenance menu. If pressed incorrectly halfway through, press the escape button several times, and repeat from the beginning at the initial screen.
Maintenance Menu
3
Select M. Mode ROM Version
Turn the jog dial to display “Finisher Setting”, and press the jog dial to confirm. Finisher Setting None
4
Select the downstream processing unit to be connected. When connecting the DBM-120 Sheet by Sheet Turn the jog dial and select “DBM120” if connecting only the DBM-120 Sheet by Sheet, or “DBM120+120T” if connecting also the DBM-120T, and press the jog dial to confirm.
Finisher Setting DBM12O+12OT
6
3. INSTALLATION OF DSF-2000
When connecting the DBM-400 Sheet by Sheet Turn the jog dial to select “DBM400”, and press the jog dial to confirm.
Finisher Setting DBM4OO
Perform the following settings. q Turn the jog dial to display “Feed Speed”, and press the jog dial to confirm.
Feed Speed 135O[mm/sec]
w Turn the jog dial to set the value to “145”, and press the jog dial to confirm.
Feed Speed 145O[mm/sec]
e Match the contents registered with the DBM-400 Sheet by Sheet memory number to this unit.
→ Memory number 1 : L = 420.0 mm W = 297.0 mm Saddle-stapling (16.54") (11.69") A4 → Memory number 2 : L = 297.0 mm W = 210.0 mm Saddle-stapling (11.69") (8.27") 11 × 17 → Memory number 3 : L = 431.8 mm W = 279.4 mm Saddle-stapling (17") (11") LTR → Memory number 4 : L = 279.4 mm W = 215.9 mm Saddle-stapling (11") (8.5") A3SR → Memory number 5 : L = 450.0 mm W = 320.0 mm Saddle-stapling (17.72") (12.60") Custom 1 (Initial setting: B4) → Memory number 6 : L = 364.0 mm W = 257.0 mm Saddle-stapling (14.33") (10.12") Custom 2 (Initial setting: B4) → Memory number 7 : L = 364.0 mm W = 257.0 mm Saddle-stapling (14.33") (10.12") Custom 3 (Initial setting: B4) → Memory number 8 : L = 364.0 mm W = 257.0 mm Saddle-stapling (14.33") (10.12") A3
5
Folding Folding Folding Folding Folding Folding Folding Folding
Turn off the power of this unit.
This ends the setting of the downstream processing unit. This setting will be effective from the next time the power is turned on.
This ends the installation procedure. 7
99T-90191-01070030M-0