EM

Report 18 Downloads 507 Views
TYPE

QTY

MANUFACTURER

CATALOG #

L1

24

SELUX

M1DI-2T8-OD-XX-C-004-WH-277V-DM-CN16001-4'

L4

4

SELUX

M10-1T8-OD-SF1-004-WH-277V-1FW-4'

L5

4

FOCAL POINT

FSM6L-FL-625LF-1C-277V-LD1-G3-WH-8'

L5A

12

FOCAL POINT

FSM6L-FL-625LF-1C-277V-LD1-G3-WH-6'

L6A

2

PEERLESS

NRW9-1-54T5H0-WHR-FST-4FT-R4-277V-GEB10-SCT-L/LP-C041

L8

30

FOCAL POINT

FEQ-14-B-2T8-D7-277V-ST-G3-WH

P1

10

RICH BRILLIANT LTG

DELTA-DE-I-FINISH-120V

P2

6

RICH BRILLIANT LTG

DELTA-DE-IV-FINISH-120V

P3

9

RICH BRILLIANT LTG

DELTA-DE-VII-FINISH-120V

P4

13

FABBIAN

F07-A05-A-01

P5

5

FABBIAN

F07-A07-A-01

P6

1

BIRCHWOOD

ERI-LED-325S-SLO-****-F-LSFM-12'X16'-SC-UNV-EB-CSS-36-X-STD-X

P7

5

ARTEMIDE

EMPATIA-16-SUSPENSION

P8

2

FINELITE

HP4-WW-D-K-8'-SO-3500K-277V-FA/FM-X-X

P8A

1

FINELITE

HP4-WW-D-K-4'-SO-3500K-277V-FA/FM-X-X

R1

33

LITHONIA

EVO-35/20-4AR-WD-LSS-MVOLT-EZ1

R2

9

LITHONIA

EVO-WW-35/20-4AR-WD-LSS-MVOLT-EZ1

R3

2

AXIS

DIA-22-VL-T5-2-W-UNV-ERS-1-TB15

S2

2

BARTCO

BDS850-32/4-UNV

S4-150'

1

AION

8924-27-LE

S4-225'

1

AION

8924-27-LE

S5-15'

2

AION

8924-27-LE

S4/S5

27

AION

AC-A24

S4/S5

27

AION

D100-DC-24

L9

1

FINELITE

HP4-WW-D-K-8'-SO-3500K-277V-X-X-X

L9A

1

FINELITE

HP4-WW-D-K-4'-SO-3500K-277V-X-X-X

OSC1

6

GREENGATE

OAC-DT-1000-R/SP20-MV

OSC2

7

GREENGATE

OAC-DT-0501-R/SP20-MV

OSW1

9

GREENGATE

ONW-D-1001-MV-W

OSW2

13

GREENGATE

VNW-D-1001-MV-W

DIM

14

GREENGATE

SF10-PW

EM

1

GREENGATE

CEPC-1-D

EM

1

GREENGATE

RRU-1-120

LVS

7

GREENGATE

GMDS-W

LCP

9

COOPER

LK8

EBR

5

BODINE

GTD20A

Submitted by Reflex Lighting Group, Inc,

Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY

Catalog Number: SF10P-W

Type:

Notes: QUOTING (1) FOR SINGLE AND (2) FOR 3-WAY DIMMING

SD BOST16-86147

Greengate

Technical Data

0-10V Slide Dimmer Wallstation Catalog#

Prepared by

Project

Date

Comments

Type

Overview The 0-10 Volt Slide Dimmer provides full-range classic linear-slide dimming for 0-10V compatible dimmable light sources. These units are ideal for light commercial applications and are compatible with decorator style devices and wallplates. The preset “ON/OFF” switch automatically returns controlled light(s) to a preset level without disturbing the brightness level. The device is designed for both Single-pole (one location) and 3-way (multi-location) applications.

Features Preset feature allows user to return to previous light level when turning lights ON Integrated full-slide control for easy, precise operation Can be wired as Single-pole or 3-way Neutral is not required for installation of device Adjustable high-level trim setting for optimal lamp compatibility

DIMMERS 6B28

Submitted by Reflex Lighting Group, Inc,

Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY

Catalog Number: SF10P-W Notes: QUOTING (1) FOR SINGLE AND (2) FOR 3-WAY DIMMING



Specifications Switch Type Dimming Control

Single-pole and 3-way 0-10 VDC: 200mA Sink Sink Dimming

Electrical Ratings

120 VAC: Max. Load: 10 amps, 1200W, 60 Hz 277 VAC: Max Load: 6 amps, 1660W, 60 Hz Full-range, continuously variable dimming Adjustable High-level trim setting

Light Intensity Control Power Failure Memory Wiring Type

Light returns to same level prior to power interruption Back & side wiring terminals; 12-14 AWG (Copper wire) 0-10V wire leads; 16 AWG Meets UL 94 requirements, V2 rated -4°F to 158°F (-20°C to 70°C)

Flammability Temperature

Wiring Diagrams FIGURE 1: SINGLE-POLE WIRING DIAGRAM Green or Bare Black Thumbwheel

TOP

BK VT

Hot

YL Line 120 VAC - 60 Hz

Gray

Violet

Black Slider

GY

LOAD

White

FIGURE 2: 3-WAY WIRING DIAGRAM

Neutral

*

Black Thumbwheel

Green or Bare

TOP

Gray

VT Violet

SD BOST16-86147

0-10V Slide Dimmer Wallstation  

December 2015

BK

YL

3-WAY SWITCH

DIMMER

YL

Tag BK

GY

Travellers

YL

Black YL

Hot

Slider Line 120 VAC - 60 Hz

LOAD White

*Can be installed on load or line side in 3-way applications Visit our website for additional wiring details at www.eaton.com/lightingsystems

2

Type:

www.eaton.com/lightingsystems

Neutral

Submitted by Reflex Lighting Group, Inc,

Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY

Catalog Number: SF10P-W

Type:

Notes: QUOTING (1) FOR SINGLE AND (2) FOR 3-WAY DIMMING



SD BOST16-86147

0-10V Slide Dimmer Wallstation  

December 2015

Ordering *Wallplate not included This is an accessory for the Greengate Lighting Control System. When ordering, specify the 0-10V slide dimming wallstation as a separate system accessory. Catalog #

Description

SF10P-LA SF10P-BK SF10P-GY SF10P-V SF10P-W

Dimmer Dimmer Dimmer Dimmer Dimmer

Slider Slider Slider Slider Slider

Colors

0-10V, 0-10V, 0-10V, 0-10V, 0-10V,

120/277 VAC 120/277 VAC 120/277 VAC 120/277 VAC 120/277 VAC

Light Almond Black Gray Ivory White

* Refer to Screwless Wallplate Spec Sheet for ordering information at www.eaton.com/lightingsystems. NNote: Custom engraving is not available on 0-10V dimming wallstations.

Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Lighting systems 203 Cooper Circle Peachtree City, GA 30269 www.eaton.com/lightingsystems © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD503061EN December 8, 2015

Eaton is a registered trademark. All other trademarks are property of their respective owners.

Submitted by Reflex Lighting Group, Inc,

Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY

Technical Data

Catalog Number: CEPC-1-D

Type:

EM

Notes:

BOST16-86147

Effective September 30, 2014

CEPC – Emergency Power Control Catalog#

Prepared by

Project

Date

Comments

Type

CEPC-1

CEPC-D-F-S-120

Overview The Eaton's Cooper Controls Emergency Power Control (CEPC) device allows the control of emergency lighting in iLumin architectural dimming systems.

Submitted by Reflex Lighting Group, Inc,

Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY

Catalog Number: CEPC-1-D Notes:

CEPC – Emergency Power Control  

September 2014

General

Electrical Data

Mechanical:

Mounting:

Environment: Interfacing:

Eliminates energy waste by allowing emergency lighting to be switched and dimmed Fail safe operation Visible emergency power LED Visible regular power LED Integral test switch Senses local circuit power loss UL 924 listed, meets NEC, OSHA and NFPA safety codes Connections: Normal Power Sensing/Control: 120V or 277V Emergency Power: 120V or 277V Load Ratings: 20A Ballast Load Rating 1800W Incandescent Load Rating at 120V 1500W Incandescent Load Rating at 277V (CEPC-1 only) Size: CEPC-1 Body Size: 2-7/8” x 1-3/4” x 1-3/4” Flushmount size: 4-3/4”x2-3/4”x 1/4” CEPC-D-F-S-* Surface mount size: 6”x6”x2-1/4” CEPC-1 mounts to a 4-11/16” Junction box with single gang plater ring UL94-5VA Rated Plastic Color: CEPC-1 = White, CEPC-D-F-S-* = Black Weight: CEPC-1 = 8oz, CEPC-D-F-S-* = 16oz Ambient Temp Rating: 32°F - 140°F (0°C - 60°C) Compatibility: CEPC-1: iLumin SC-RP, SC-RPB and Greengate Occupancy Sensors CEPC-D-F-S-*: iLumin SC-UN, SC-UN-FT

Standards

2

www.coopercontrol.com

EM BOST16-86147

Technical Data 

Specifications

Type:

Operation The CEPC senses a local single normal power circuit. As long as normal power is present the CEPC permits normal and emergency switching and dimming of the lighting load from the iLumin architectural dimming system. If normal power is lost for any reason, the CEPC will force the connected emergency fixtures to full ON. The CEPC can be wired as either a control device along with a relay panel and occupancy sensor, or as a shunt to bypass line voltage switching devices when normal power fails. The CEPC-D-F-S is a universally compatible device that allows control of 2, 3, and 4-wire emergency dimming loads. When normal power is lost the CEPC-D-F-S will force the emergency fixtures to the full bright condition. Both CEPC models include a test switch feature for verifying proper functionality. In addition the CEPC-1 model also provides an automatic test feature. Under normal operation, when the controlled load is turned OFF, the emergency lighting will remain on an additional 2.5 seconds, providing safety and convenience while leaving the area and eliminating the need of special equipment to test the emergency control of the device.

Installation The CEPC can be installed down line of the iLumin panels. The CEPC should be located next to the emergency fixture it is controlling.

Submitted by Reflex Lighting Group, Inc,

Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY

Catalog Number: CEPC-1-D

Type:

EM

Notes:

BOST16-86147

Technical Data

CEPC – Emergency Power Control  

September 2014

Wiring Diagram Wiring Diagram for 3-Wire Dimming Loads

CEPC-1-D

Emergency Power

3 4

20A

Test

Emergency Panel

5 6 7

8 9 10

Test

7 EM Neutral

20A

Emergency Lighting Load

Test

Emergency Panel

Emergency Lighting Load

6 EM Load RED

Test

(Violet 0-10V)

Utility Power

Blue

X1 X2

(Violet 0-10V)

1 2

3

Utility Power

Emergency Power

5 EM Hot

1 or 2 4

CEPC-D-F-S

Regular Neutral

0-10V Gray wire

Regular Line Hot (Sensing Circuit)

iLumin SC-UN Power Card Load

Hot Switched Hot Dimmed Hot

Line

CK4A or Room Controller Relay

Neutral

3-Wire Dimming

CEPC-D-F-S CEPC-D-F-S Wire## Wire

3 - Wire Dimming

VIOGRY 1 1

Description Description

iLumin Connection Connection iLumin

4-Wire Dimming

1

1

Regular HotHot Regular

iLumin Power CardCard (L) iLumin Power

(L)

2

2

Regular Neutral Regular Neutral

iLumin Power CardCard (N) iLumin Power

(N)

3

3

Emergency HotHot Emergency

4

4

Emergency Neutral

5 6 7 8 9

CK4A or Room Controller 0-10V outputs

Emergency Neutral

CEPC-1-D Wire #

Color

Description

iLumin Connection

1

Black

Regular Hot (120V)

Constant Hot and Relay Line

2

Orange

Regular Hot (277V)

Constant Hot and Relay Line Relay Load

5

Switched Hot

iLumin Power Card (S)

6

Dimmed Hot

iLumin Power Card (D)

3

Red

Switched Hot

7

Regular Neutral

iLumin Power Card (N)

4

White

Regular Neutral

8

To Load Hot

5

blue

Emergency Hot

6

Yellow

Emergency Load Hot

7

White/Blue

Emergency Neutral

Switched Hot

iLumin Power Card (S)

Dimmed Hot

iLumin Power Card (D)

Regular Neutral

iLumin Power Card (N)

9

Load Hot Hot ToTo Load Dimmed

10

Load Dimmed Hot ToTo Load Neutral

10 X1

ToNot Load Do CutNeutral

X1 X2

Do Not Do Not CutCut

Blue

Dimmer Violet (0-10V +)

Do Not Cut

Red

To Load Violet (0-10V +)

Black

Cap Off

X2

Panel Dimmer Output Violet

Wiring Diagram for 2-Wire Dimming Loads CEPC-D-F-S

Emergency Panel

5 6 7

Test

Emergency Lighting Load

X1 X2

Test

Emergency Panel

Yellow

Red

iLumin SC-UN Power Card

Switchleg

Regular Line Hot (iLumin SC-RP transformer power) (or other constant hot circuit)

Load

20A

Neutral

CEPC-D-F-S CEPC-D-F-S # Wire Wire #

Regular Neutral (iLumin SC-RP Neutral wire)

iLumin SC-RP Relay Card

Hot Switched Hot Dimmed Hot

2-Wire Dimming 2 - Wire Dimming

Emergency Lighting Load

Blue/ White

Test

Utility Power

1 2

Utility Power

CEPC Emergency Power

Blue Blue/ White

20A

White

Test

8 9 10

Black/ Orange

20A

Wiring Diagram for 2-Wire Non Dimmed Loads

Emergency Power

3 4

Line

Normal Panel

Description

iLumin Connection

Description

iLumin Connection

2 - Wire Non Dimmed 2-Wire Non Dimmed

1 1 2 2

Regular Hot Regular Hot

iLuminCard Power iLumin Power (L) Card (L)

CEPCCEPC Wire #

Description

Regular Regular Neutral Neutral

iLuminCard Power iLumin Power (N) Card (N)

Blue

Emergency Hot

3 3

Emergency Hot Emergency Hot

Yellow

Emergency Switchleg

4 4

Emergency Emergency Neutral Neutral

Blue/White

Emergency Neutral

5 5

Dimming Hot Dimming Hot

6 6

Not Used Not Used

Black/Orange Hot(Sensing) (Sensing) Regular Hot Black/Orange Regular

Transformer Power (or Transformer Power other constant hot circuit

7 7

Regular Regular Neutral Neutral

Red

Switchleg

Relay Load Terminal Block

8 8 9

Regular Neutral Regular Neutral

Transformer Neutral Wire Transformer Neutral wire

Not Used

9

To LoadTo Hot Load Hot

10

To Load Neutral Do Not Cut

X2

Do Not Cut

X1 X2

Blue

Yellow

iLuminCard Power iLumin Power (D) Card (D) iLumin Power (N) Card (N) iLuminCard Power

Blue/White

Red

White White

Description

iLumin Connection

iLumin Connection

Emergency Hot

Emergency Switchleg

Emergency Neutral

Switchleg

(or other constant hot circuit)

Relay Load Terminal Block

Not Used

X1

10

Wire #

To Load Neutral Do Not Cut Do Not Cut

www.coopercontrol.com

3

Submitted by Reflex Lighting Group, Inc,

Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY

Catalog Number: CEPC-1-D

Type:

EM

Notes:

BOST16-86147

Technical Data 

CEPC – Emergency Power Control  

September 2014

Ordering Catalog #

Descriptoin

Rating

CEPC-1 CEPC-D-F-S-120 CEPC-D-F-S-277

Emergency Power Control 120V/277V Emergency Power Control 120V Emergency Power Control 277V

120V or 277V (Switching) 120V (2-wire, 3-wire, 4-wire dimming loads) 277V (2-wire, 3-wire, 4-wire dimming loads)

CEPC-1-D

Emergency Power Control 120V/277V 0-10V

120V or 277V (0-10 dimming loads)

CEPC-1-CUL

Emergency Power Control for Canada 120V/277V

120V or 277V (Switching)

CEPC-D-F-S-120V-CUL

Emergency Power Control for Canada 120V

120V (2-wire, 3-wire, 4-wire dimming loads)

CEPC-D-F-S-277V-CUL

Emergency Power Control for Canada 277V

277V (2-wire, 3-wire, 4-wire dimming loads)

CEPC-1-D-CUL

Emergency Power Control for Canada 120V/277V 0-10V

120V or 277V (0-10 dimming loads)

Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, GA 30269 coopercontrol.com © 2014 Eaton All Rights Reserved Printed in USA Publication No. ACC140950 September 30, 2014

Eaton is a registered trademark. All other trademarks are property of their respective owners.

Submitted by Reflex Lighting Group, Inc,

Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY

Catalog Number: RRU-1-120

Type:

EM

Notes:

BOST16-86147

Greengate

Technical Data

RRU-1 – UL 924 Remote Relay Unit Catalog#

Prepared by

Project

Date

Comments

Type

Overview The Remote Relay Unit (RRU-1) is available in 120 VAC and 277 VAC input voltage configurations. The RRU-1 is designed to force all outputs in the lighting control panel to an emergency scene regardless of the control panel’s programmed output status. This allows the override of outputs during loss of normal (grid) power to allow an alternate power source to drive the lighting loads (Once the RRU-1 senses the normal power returning, the control panel will return to the normal programmed operating mode).

Features UL 924 Listed Accessory Detects loss of normal power and automatically sends signal to lighting control panel Allows Greengate panels to be listed as UL 924 when RRU-1 is connected

Submitted by Reflex Lighting Group, Inc,

Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY

Catalog Number: RRU-1-120

Type:

EM

Notes:

BOST16-86147

RRU-1 – UL 924 Remote Relay Unit July 2015

Features General Electrical Data Mechanical Data Compatibility Standards

Operation UL 924 Listed Connects to normal power Lighting Control Panels must be fed from alternate power ControlKeeper M, ControlKeeper MB UL Approved UL 924 Listed

The RRU-1 provides a dry contact closure to the ControlKeeper M and MB panels when normal (grid) power is lost. This contact closure forces a hardware override of all relays in the enclosure to the ON state. This override condition takes priority over any relay commands from the system controller and will remain in effect until the contact closure from the RRU-1 is opened.

Installation The RRU-1 can be installed next to the lighting control panel enclosure.

2

www.eaton.com/lightingsystems

Submitted by Reflex Lighting Group, Inc,

Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY

Catalog Number: RRU-1-120 Notes:

Type:

EM BOST16-86147

RRU-1 – UL 924 Remote Relay Unit July 2015

Wiring Diagram +

SH

RS485

RS485

MOR/LRM

Off

R35

The RRU-1 needs to provide a dry contact maintained closure to the On and +24 terminals on the ControlKeeper M motherboard MOR connector.

On

+24V

CAN-H

232 OPT

+24

ON

+24

MOR/RIM OFF

CAN-L

SHIELD

GND

USB USB HOST DEVICE

TB2

TO CCM

RS-232

For Emergency panel configurations, ensure the ControlKeeper M lighting control panel is fed from an emergency power source.

ETHERNET

+

-

J14

-

SH

CCM PWR

NET-RX

LED7

DISPLAY

ALL-OFF ALL-ON

NET NET HEART TX

LED6

LEFT RELAYS

1

RIGHT RELAYS

J9

S1

1

RESET A

J11

B

C

1

J7

C67

U35

J6

U37 SW2

SW4

SW3

1

SW6

MOR/LRM

D U34

SW5

A

B

HEART BEAT U32

RS232 Boot Mode

NET ADDRESS

+5

R25

On

C158A

PG

GND

8 16 32 64 128

+24

4

GND

J15

2

+24

LED11

SCM PWR

C149

1

Off

SW1

5001-000006-05

To override On: Connect dry contact between the On terminal and the +24 VDC terminal. When contact closes, all relays are forced ON. Contacts within the RRU-1 will automatically close when normal power is lost

Red (14 AWG) NC

Black (14 AWG)

C

SPST Relay

C Neutral = White (16 AWG)

Hot 120 VAC = Black Hot 277 VAC = Orange

To Normal Power Source (16 AWG) To Normal Power Circuit

Ordering This is an accessory for the ControlKeeper M and ControlKeeper MB lighting control panels. When ordering, specify the RRU-1 as a separate system accessory. Catalog #

Descriptoin

Rating

RRU-1-120V RRU-1-277V

UL924 Remote Relay Unit UL924 Remote Relay Unit

120 VAC 277 VAC

Note: Note: for 347 VAC Applications please see Model LRM-347

Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Lighting systems 203 Cooper Circle Peachtree City, GA 30269 www.eaton.com/lightingsystems © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD503029EN July 27, 2015

Eaton is a registered trademark. All other trademarks are property of their respective owners.

In cooperation with: LVS,Inc.

Recommend Documents