Epoca Glenoid Wall Chart (PDF)

Report 4 Downloads 103 Views
19766-J9331A_FR:Layout 1

5/20/09

5:50 PM

Page 1

Epoca Shoulder Arthroplasty System– Glenoid Replacement. Total arthroplasty for fracture and degenerative conditions.

Quick Reference Chart

Synthes (USA) 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 Fax: (610) 251-9056 © 2009 Synthes, Inc. or its affiliates. All rights reserved.

Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185

Epoca and Synthes are trademarks of Synthes, Inc. or its affiliates.

www.synthes.com Printed in U.S.A. 5/09 J9331-A

19766-J9331A_BA:Layout 1

5/23/09

1:16 AM

Page 1

Epoca Shoulder Arthroplasty System–Glenoid Replacement. Total arthroplasty for fracture and degenerative conditions.

1

2

3

4

Approach and exposure

Locate center point

Introduce K-wire

Ream glenoid

– Protect prepared humerus with a protection cover – Glenoid exposure must permit use of straight instruments

– Center point is slightly inferior to the midpoint of Saller‘s line

– Introduce a K-wire using the drill guide

– Ream clockwise – Correct inclination in the horizontal plane – Correct inclination in the frontal plane

5

6

7

8

Drill peg holes

Introduce trial glenoid

Implant all-poly glenoid

Insert glenoid

– Drill the distal hole first, using a shorter (150 mm) drill – Depth of drill hole depends on glenoid type – Leave drill in place for rotational stability

– Glenoid size must match size of humeral head implant

– Introduce a small amount of bone cement into the two drill holes – Avoid cement under the faceplate

– Impact the glenoid implant with light taps of the 350 g hammer on the glenoid impactor

Epoca Shoulder Prosthesis Glenoid Instrument Set (01.401.004) Graphic Case 60.401.004 Graphic Case for Epoca Glenoid Instruments Instruments E5115-7 E5211-2 E5211-3 E5211-4L E5211-4R E5211-6K E5211-6L E5211-8 E5211-8E E5211-9 E5211-10 E5211-28 E5211-32

Head Impactor Rigid Guide Extension 10 mm Wrench, 2 ea. Drill Guide, left Drill Guide, right 7.4 mm Drill Bit, 150 mm 7.4 mm Drill Bit, 200 mm Glenoid Clamp Trial Glenoid Clamp Thorn for Reamer Glenoid Impactor 28 mm Reamer for Glenoid 32 mm Reamer for Glenoid

E5213-42 E5213-46 E5213-50 E5213-54

Trial Glenoids size 42 size 46 size 50 size 54

292.75

2.5 mm Kirschner Wire with Thread, 150 mm, with trocar point, 10/pkg.

Please refer to technique guide for indications and complete instructions for use.

19766-J9331A_FR:Layout 1

5/20/09

5:50 PM

Page 1

Epoca Shoulder Arthroplasty System– Glenoid Replacement. Total arthroplasty for fracture and degenerative conditions.

Quick Reference Chart

Synthes (USA) 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 Fax: (610) 251-9056 © 2009 Synthes, Inc. or its affiliates. All rights reserved.

Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185

Epoca and Synthes are trademarks of Synthes, Inc. or its affiliates.

www.synthes.com Printed in U.S.A. 5/09 J9331-A