G XV VAND 001

Report 3 Downloads 131 Views
Oldroyd Finishing Profile

Vandex BB75E/Cemelast (2 Coats)

Vandex Super power trowelled onto top of slab

Vandex BB75E/Cemelast (2 Coats)

Unimortar1 fillet

Oldroyd Xv membrane Closed Cell Insulation e.g. Knauf

Basement Wall Oldroyd Xs membrane Closed Cell Insulation e.g. Knauf Oldroyd Xv Black membrane Shingle - 40mm S.S. Wrapped With Oldroyd Tp Filter Fleece Perforated Land Drain (Geotextile wrapped) NOTES:

All SAFEGUARD CAD drawings show typical applications and our Technical Department should be consulted before they are used for specification purposes. Product applicators should refer to the manufacturer's application/installation guidelines.

System Drg. Nos:

G-XV-VAND-001(5).tcw (TurboCAD) G-XV-VAND-001(5).dwg (Autocad) G-XV-VAND-001(5).pdf (Acrobat)

DATE

JDF, CBS

31/03/2008

CHK. BY

APP. BY MOD. BY JDF, CBS

DATE 09/07/2008

CHK. BY

APP. BY MOD. BY

Safeguard Europe Ltd.

CONTRACT No:

The land drain should be permanently maintainable and discharge to an appropriate point.

MOD. BY

CLIENT:-

DATE

CHK. BY

DRAWN DATE SCALE (A3) APP. BY CHECKED APPROVED

JDF, CBS 25th February 2005 Not To Scale

TITLE: Oldroyd Xv + Vandex + External Insulation

DRG. No. G/XV/VAND-001

Safeguard Europe Ltd, Redkiln Close, Redkiln Way, Horsham, West Sussex, RH13 5QL Tel: 01403 210204 Fax: 01403 217529 www.safeguardeurope.com