Hamilton® Syringes

Report 12 Downloads 81 Views
general chromatography

Hamilton® Syringes

700 Series Microliter™ Syringes General Purpose Syringe, 5μL to 500μL

1000 Series Gastight® Syringes Gas and Liquid Tight, 1mL to 100mL

s¬0LUNGERS¬ARE¬NOT¬ INTERCHANGEABLE¬OR¬REPLACEABLE s¬!CCURATE¬TO¬¬OF ¬THE¬SYRINGE¬VOLUME

s¬04&% TIPPED¬PLUNGERS s¬2EPLACEABLE¬BARRELS¬AND¬PLUNGERS

Hamilton® 700 Series Microliter™ Syringes Model

Hamilton® 1000 Series Gastight® Syringes Model

Volume

Gauge

Pt. Style

Repl. Needle Part No.

Removable Needle Syringes (RN), 2" Needle Length 1001 1.0mL 22 2 7779-01 1002 2.5mL 22 2 7779-01 1005 5.0mL 22 2 7779-01 1010 10.0mL 22 2 7779-01 PTFE Luer Lock Syringes (TLL), 2" Needle Length 1001 1.0mL — — * 1002 2.5mL — — * 1005 5.0mL — — * 1010 10.0mL — — * 1025 25.0mL — — * 1050 50.0mL — — * 1100 100.0mL — — *

Part No.

81330 81430 81530 81630 81320 81420 81520 81620 82520 85020 86020

6ISIT¬OUR¬WEBSITE¬FOR¬A¬COMPLETE¬LISTING¬OF ¬REPLACEMENT¬NEEDLES

1700 Series Gastight® Syringes Gas and Liquid Tight, 10μL to 500μL s¬04&% TIPPED¬PLUNGERS s¬2EPLACEABLE¬BARRELS¬AND¬¬ PLUNGERS Hamilton® 1700 Series Gastight® Syringes Model

Volume

Gauge

Pt. Style

Repl. Needle Part No.

Part No.

6ISIT¬OUR¬WEBSITE¬FOR¬A¬COMPLETE¬LISTING¬OF ¬REPLACEMENT¬NEEDLES

Gauge

Repl. Needle Part No.

Pt. Style

Qty.

Part No.

ea ea ea ea ea ea ea ea ea ea ea ea ea ea ea

87900 87919 80300 803830 80339 80400 80465 80439 80500 80565 80665 80700 80765 80800 80865

ea ea ea ea ea

87930 80330 80530 80630 808301

ea ea ea ea

80301 80501 80601 80701

Cemented Needle Syringes (N), 2" Needle Length 75 5μL 26s 2 — 5μL 26s 3 — 701 10μL 26s 2 — 10μL 26s 3 — 10μL 26s 5 — 702 25μL 22s 2 — 25μL 22s 3 — 25μL 22s 5 — 705 50μL 22s 2 — 50μL 22s 3 — 710 100μL 22s 3 — 725 250μL 22s 2 — 250μL 22s 3 — 750 500μL 22 2 — 500μL 22 3 — Removable Needle Syringes (RN), 2" Needle Length 75 5μL 26s 2 7758-02 701 10μL 26s 2 7758-02 705 50μL 22s 2 7758-03 710 100μL 22s 2 7758-03 750 500μL 22 2 7779-01 Luer Tip Syringes (LT) 701 10μL — — * 705 50μL — — * 710 100μL — — * 725 250μL — — *

6ISIT¬OUR¬WEBSITE¬FOR¬A¬COMPLETE¬LISTING¬OF ¬REPLACEMENT¬NEEDLES

best value

Save Money on Model 701 with Multi-Packs

syringes

Removable Needle Syringes (RN), 2" Needle Length 1701 10μL 26s 2 7758-02 800300 1702 25μL 22s 2 7758-03 80230 1705 50μL 22s 2 7758-03 80930 1710 100μL 22s 2 7758-03 81030 1725 250μL 22s 2 7779-03 81130 1750 500μL 22 2 7779-01 81230 PTFE Luer Lock Syringes (TLL)/Without Slots 1725 250μL — — * 81120 1750 500μL — — * 81220 For Rheodyne®, Valco® VISF-2, Beckman®/Altex, SSI (RNR) Valves, 2" Needle Length 1705 50μL 22s 3 7770-01 80965 1710 100μL 22s 3 7770-01 81065 1725 250μL 22 3 7780-04 81165 1750 500μL 22 3 7780-04 81265

Volume

s¬%CONOMICAL ˆ SYRINGES¬COST¬LESS¬IN¬SIX¬PACKS s¬%ASY¬IDENTIlCATION ˆ SIX¬NUMBERED¬DOTS¬ PROVIDE¬QUICK¬SYRINGE¬IDENTIlCATION Hamilton® 700 Series Six-pack Syringes (2" Needle Length) Model

Volume

Gauge

Repl. Needle Part No.

Pt. Style

Cemented Needle Syringes (N), 2" Needle Length 701N 10μL 26s 2 — 701RN 10μL 26s 2 7758-02

Qty.

Part No.

6 6

80366 80336

Autosampler Syringes For the Agilent 7673 and 7683 Autosamplers s¬3TANDARD¬NEEDLE¬LENGTH¬IS¬



SampleLock Syringes

Syringes for the Agilent 7673 and 7683 Autosamplers

s¬¬AND¬¬3ERIES¬ SYRINGES¬WITH¬TWIST¬VALVE¬

Model

Hamilton® SampleLock™ Syringes Model

Volume

Gauge

Pt. Style

SampleLock™ Syringes, 2" Needle Length 1705 50μL 22s 1710 100μL 22s 1001 1mL 22 1005 5mL 22 1025 25mL 22

2 2 2 2 2

Repl. Needle Part No.

Part No.

7779-03 7779-03 7779-01 7779-01 7779-01

80956 81056 81356 81556 863260

Volume

Gauge

Cemented Needle Syringes (ASN) 75 5μL 23s 5μL 26s 5μL 23s-26s 5μL 23s-26s 701 10μL 23s 10μL 23s 10μL 23s 10μL 23s-26s 10μL 23s-26s

Pt. Style

Qty.

Part No.

AS AS AS AS AS AS 2 AS AS

6 6 ea 6 ea 6 ea ea 6

87990 87989 87993 87994 803871 803901 80398 80393 803911

www.discoverysciences.com

69

general chromatography

SGE® Syringes Plunger Protection Syringes

Autosampler Syringes

General Purpose Syringes with Reinforced Plunger, 5μL and 10μL s¬)NCLUDES¬CERTIlCATE¬OF ¬CONFORMANCE¬TO¬.)34 SGE® Plunger Protection Syringes Volume

Gauge

Length

SGE® Autosampler Syringes

Pt. Style

Fixed Needle Syringes 5μL 26 5cm 10μL 26 5cm 10μL 26 5cm 10μL 26 5cm Removable Needle Syringes 5μL 26 5cm 10μL 26 5cm 10μL 26 5cm

Repl. Needle Part No.

Qty.

Part No.

2 2 2 2

— — — —

ea ea 6 10

85184 85056 85190 85400

2 2 2

85272 85294 85294

ea ea 6

85186 85050 85194

Micro Syringes s¬0LUNGER IN NEEDLE ¬«,¬TO¬«, s¬,IQUID¬AND¬GAS¬TIGHT¬TO¬¬ATMOSPHERES

SGE® Microvolume Syringes

syringes

Volume

Gauge

Length

Pt. Style

Repl. Needle/Plunger Part No.

Part No.

— 85235 85268 85284 85243 85245 — —

85028 85209 85000 85030 85211 85213 85215 85032

85268 85284 85245 — —

85223 85225 — 85229 85231

Standard Barrel — 8mm o.d. 0.5μL 23 7cm 1 0.5μL 23 7cm 2 1μL 23 5cm 1 1μL 23 7cm 1 1μL 23 7cm 2 1μL 26 7cm 1 5μL 23 5cm 1 5μL 23 7cm 1 Standard Barrel with Repeating Adapter 1μL 23 5cm 1 1μL 23 7cm 1 1μL 26 7cm 1 5μL 23 5cm 1 5μL 23 7cm 1

5SE¬A¬REPEATING¬ADAPTER¬TO¬PREVENT¬PLUNGER¬BLOW OUT¬AT¬ELEVATED¬PRESSURES

Gas Tight Syringes Gas and Liquid Tight, 10μL to 10mL

Volume

Gauge

Pt. Style

Repl. Needle Part No.

For Agilent 7673 Autosamplers Fixed Needle 5μL 23 1 — 5μL 23 1 — 5μL 26 1 — 5μL 26 1 — 10μL 23 1 — 10μL 23 1 — 10μL 26 1 — 10μL 26 1 — For PerkinElmer ® Autosystem Fixed Needle 5μL 23 1 — 5μL 26 1 — 50μL 23 1 — Gas Tight Fixed Needle 5μL 23 1 — 5μL 26 1 — Removable Needle 0.5μL 23 1 — 0.5μL 26 1 85306 For Shimadzu® Autosamplers Models AOC14 and 17—Removable Needle 0.5μL 26 1 — 10μL 26 1 85316 For Varian® Autosamplers Model 8000—Removable Needle 10μL 25 5 — Models 8035, 8100, 8200—Removable Needle 10μL 25 5 85173 For CTC/Fisons AS200 and AS800 Autosamplers Fixed Needle (50mm) 10μL 26 1 — 25μL 26 1 — Fixed Needle (80mm) 10μL 26 1 — Gas Tight Fixed Needle (50mm) 10μL 23 1 — 25μL 23 1 —

Qty.

Part No.

ea 6 ea 6 ea 6 ea 6

85014 85140 85136 85138 85144 85036 85142 85034

ea ea ea

85069 85067 85419

ea ea

85160 85158

ea ea

85156 85154

ea ea

85166 85172

ea

85176

ea

85180

ea ea

85297 85401

ea

85398

ea ea

85399 85402

Guided Plunger Syringes Extended Barrel Syringes, 5μL and 10μL

SGE® Gas Tight Syringes, Needles included Volume

Gauge

Removable Needle 10μL 26 25μL 25 50μL 25 100μL 25 250μL 25 500μL 25 1mL 23 2.5mL 23 5mL 23 10mL 23

Length

Pt. Style

Repl. Needle Part No.

5cm 5cm 5cm 5cm 5cm 5cm 5cm 5cm 5cm 5cm

2 2 2 2 2 2 2 2 2 2

85294 85274 85274 85274 85274 85274 85276 85276 — —

s¬2EINFORCED¬PLUNGER Part No.

85004 85331 85070 85072 85074 85076 85078 85117 85086 85090

more info For more information about additional syringes and adapters, visit our website.

70

SGE® Guided Plunger Syringes Volume

Gauge

Length

Fixed Needle Syringes 5μL 26 5cm 10μL 26 5cm Removable Needle Syringes 5μL 26 5cm 10μL 26 5cm 10μL 26 7cm

Pt. Style

Repl. Needle Part No.

Part No.

2 2

— —

85022 85038

2 2 2

85272 85294 85163

85016 85018 85159