HomeWorks® QS Designer RF Maestro® Local Controls HomeWorks® QS RF Maestro® local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where single circuits of lighting need to be dimmed or switched. Local fan speed controls are useful in locations where control of a single ceiling paddle fan is needed. HomeWorks® QS RF Maestro® dimmers incorporate advanced features such as fade on / fade off, delayed long fade to off, and rapid full on. HomeWorks® QS RF Maestro® local controls include a Front Accessible Service Switch (FASSTM) for safe lamp replacement. HomeWorks® QS RF Maestro® local controls install in single-pole or multi-location applications. Remote dimmers / switches are available for multi-location control. Use Lutron® Designer (Claro® or Satin Colors®) wallplates or designer-style wallplates from other manufacturers. Wallplates are sold separately. Lutron® Claro® and Satin Colors® wallplates snap on with no visible means of attachment. HomeWorks® QS RF Maestro® local controls support color change kits.
www.lutron.com
1
Dimmer
Switch
Remote Dimmer
Remote Switch
Fan Speed
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Model Numbers Dimmers HQRD-6CL-XX HQRD-6D-XX HQRD-6ND-XX HQRD-10D-XX HQRD-10ND-XX HQRD-6NA-XX HQRD-F6AN-DV-XX
600 W / VA (Incandescent / Halogen / MLV) or 150 W (CFL / LED) Two-Wire Dimmer* 600 W Two-Wire Dimmer 600 W Neutral Wire Dimmer 1000 W Two-Wire Dimmer 1000 W Neutral Wire Dimmer 600 W Neutral Phase Adaptive Dimmer 6 A Fluorescent/LED 3-Wire Dimmer
Switches HQRD-8ANS-XX HQRD-8S-DV-XX
Neutral Wire Electronic Switch Two-Wire Electronic Switch
Fan Speed Control (single ceiling paddle fan only [120 V~]) HQRD-2ANF-XX 2 A Fan Speed Control Remotes (for multi-location installations) HQD-RD-XX Remote Dimmer (120 V~) HQD-RS-XX Remote Switch (120 V~) HQD-RD-277-XX Remote Dimmer (277 V~) (for use with -F6AN-DV only) HQD-RS-277-XX Remote Switch (277 V~) (for use with -8S-DV only) Color Change Kits RK-D-XX RK-S-XX RK-AD-XX RK-AS-XX RK-F-XX *
Dimmers (-6CL, -6D, -10D, -10ND, -6NA, -F6AN-DV) Switches (-8ANS and -8S-DV) Remote Dimmer (-RD) Remote Switch (-RS) Fan Speed Control (-2ANF)
Go to www.lutron.com/LEDtool to see all compatible CFL/LED lamps. Note: “XX” in the model number represents color/finish code. See Colors and Finishes at end of document.
www.lutron.com
2
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Specifications Model Numbers
Power Typical Power Consumption
Regulatory Approvals Environment
Dimmer: HQRD-6CL, HQRD-6D, HQRD-6ND, HQRD-10D, HQRD-10ND, HQRD-6NA, HQRD-F6AN-DV Switch: HQRD-8ANS, HQRD-8S-DV Fan Speed Control: HQRD-2ANF Remote: HQD-RD, HQD-RS, HQD-RD-277, HQD-RS-277 Color Change Kits: RK-D, RK-S, RK-AD, RK-AS 120 V~ 50 / 60 Hz: -6CL,-6D, -10D, -10ND, -6NA, -2ANF, -8ANS, -RD, -RS 120 – 277 V~ 50 / 60 Hz: -F6AN-DV, -8S-DV Dimmer / Switch / Fan Speed Control: 0.6 W Test conditions: load is off and nightlight mode is enabled. Remote Dimmer / Switch: 0 W Test conditions: load is off. UL, CSA (all except -6CL, -6NA), cUL (-6CL, -6NA only), NOM, FCC, IC, COFETEL
Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only. Communications Dimmers and switches communicate with the HomeWorks® system through Radio Frequency (RF) and must be located within 30 ft (9 m) of a repeater. Remote dimmers / switches are not required to be within a specific range of a repeater. ESD Protection Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2. Surge Protection Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits. Power Failure Power failure memory: should power be interrupted, the control will return to its previous state when power is restored. Mounting Requires a U.S. wallbox. 3 ½ in (89 mm) deep recommended, 2 ¼ in (57 mm) deep minimum. Wiring Uses conventional 3-way and 4-way wiring. Warranty www.lutron.com/TechnicalDocumentLibrary/warranty.pdf
www.lutron.com
3
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Design Features • • • •
•
Dimmer On a single-tap, lights fade ON or OFF. On a double-tap, lights go to full ON. When ON, press and hold the tapswitch to engage the delayed long fade to OFF. Light levels can be fine-tuned by pressing and holding the dimming rocker until the desired light level is reached. Neutral and two-wire dimmers available.
Switch • On a single-tap, lights or motors turn ON or OFF. • Neutral and two-wire switches available. • •
•
• • •
Fan Speed Control On a single-tap, fan turns ON or OFF. Fan speeds can be selected by pressing and holding the fan speed control rocker until the desired fan speed is reached. Controls one paddle-type ceiling fan (Permanent split-capacitor motor) up to 2 A. Not for use with shaded-pole type motors (e.g., bath exhaust fans). Provides 4 quiet speeds plus OFF. Not for use with fans that have integrated fan speed and/or light control modules. Requires a neutral connection.
www.lutron.com
4
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Dimensions All dimensions are shown as: in (mm) Front View
Side View
Side View
Side View
-2ANF only
-RD-277 and -RS-277 only
4 11⁄16 (119)
2 15⁄16 (75)
5/16 (8)
1 1⁄8 (30)
5/16 (8)
1 11⁄16 (43)
1 3 ⁄8 (35)
5/16 (8)
Mounting and Parts Identification
Control Mounting Screws Adapter Mounting Screws
Wallbox
Control
Wallplate Adapter
Wallplate
Wallplate Adapter / Wallplate purchased separately
www.lutron.com
5
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Ganging and Derating When combining controls in the same wallbox, derating is required (see Load Type and Capacity). No derating is required for remote dimmers, remote switches, or fan speed controls. -8ANS, -RD-277, and -RS-277 have fins that need to be removed for multigang installations.
Load Type and Capacity Do not remove outside fins on ends of ganged controls (shaded areas) A
Load Type
Minimum Load
A Not Ganged
B
B
B
C
B
B C Neutral End of Gang Middle of Gang Connection
HQRD-6CL1 Incandescent/Halogen/CFL/LED see Mixing Lamp Types, page 8 2,3 50 W/ VA 450 W/600 VA 400 W/500 VA 300 W/400 VA MLV
1
2
3 4
No
HQRD-6D1 Incandescent/Halogen MLV2
50 W 600 W 50 W/ VA 450 W/600 VA
500 W 400 W 400 W/500 VA 300 W/400 VA
No
HQRD-6ND1,4 Incandescent/Halogen MLV2
10 W 600 W 10 W/ VA 450 W/600 VA
500 W 400 W 400 W/500 VA 300 W/400 VA
Yes
HQRD-10D1 Incandescent/Halogen MLV2
50 W 1000 W 800 W 650 W 50 W/ VA 800 W/1000 VA 600 W/800 VA 500 W/650 VA
No
HQRD-10ND1,4 Incandescent/Halogen MLV2
10 W 1000 W 800 W 650 W 10 W/ VA 800 W/1000 VA 600 W/800 VA 500 W/650 VA
Yes
Dimmer Load Type: • -6D, -6ND,-10D, -10ND: designed for use with permanently-installed incandescent, magnetic low-voltage, or tungsten halogen only. • -6CL: designed for use with permanently-installed incandescent, magnetic low-voltage, tungsten halogen, CFL, or LED only. Note: Do not install dimmers to control receptacles or motor-operated appliances. Low-Voltage Applications: -6CL, -6D, -6ND, -10D -10ND: use with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low-voltage transformers. Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following: • Do not operate low-voltage circuits without operative lamps in place. • Replace burned-out lamps as soon as possible. • Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent. Do not mix CFL and LED loads with MLV loads. Power Boosters / Load Interfaces: -6ND and -10ND can be used to control power boosters / load interfaces. For a list of compatible power boosters / load interfaces see Compatible Power Boosters and Load Interfaces, page 8.
www.lutron.com
6
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Load Type and Capacity (continued) Do not remove outside fins on ends of ganged controls (shaded areas below) A
Load Type
Minimum Load
HQRD-6NA1,2 Incandescent/Halogen/ELV 5 W MLV3 5 W/ VA
B
A Not Ganged
B
B End of Gang
B
C
B
C Neutral Middle of Gang Connection
600 W 500 W 450 W/600 VA 400 W/500 VA
400 W 300 W/400 VA
Yes
0.05 A 1 ballast
6A 60 ballasts
5A 50 ballasts
3.5 A 35 ballasts
Yes
HQRD-2ANF6 Ceiling Fan
0.083 A
2A
2A
2A
Yes
HQRD-8ANS3,7 Lighting Motor
10 W 0.08 A
8A 6.5 A 1/4 HP 5.8 A 1/4 HP 5.8 A
5A 1/6 HP 4.4 A
Yes
HQRD-F6AN-DV3,4,5 Fluorescent/LED
HQRD-8S-DV7,8
1 2 3
4
5 6
7
8
Lighting
40 W/ VA 8 A
Motor
0.4 A
8 A (2-gang); 7 A (3-gang)
7A
No
1/10 HP 3 A
Note: Do not install dimmers to control receptacles or motor-operated appliances. Dimmer Load Type: -6NA: designed for use with permanently-installed incandescent, electronic low-voltage, magnetic low-voltage, or tungsten halogen only. Power Boosters / Load Interfaces: -6NA, -F6AN-DV, -8ANS can be used to control power boosters / load interfaces. For a list of compatible power boosters / load interfaces see Compatible Power Boosters and Load Interfaces, page 8. Low-Voltage Applications: -6NA: use with electronic (solid-state) or magnetic (core and coil) transformers. Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following: • Do not operate low-voltage circuits without operative lamps in place. • Replace burned-out lamps as soon as possible. • Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent. Fluorescent Dimmer Load Type: -F6AN-DV: designed for use with permanently installed 3-wire 120 V~ or 277 V~ line voltage control fluorescent ballasts or LED drivers. Use with only Hi-lume®, Hi-lume® 3D, Compact SETM, Eco-10®, or EcoSystem® (H3D-, FDB-, ECO-, HL3-, EC5-, L3D). Do NOT use with any other ballasts or drivers. Do not install to control receptacles or motor-operated appliances. Maximum Load: The maximum load for the -F6AN-DV is either the derated load or the number of ballasts, whichever is LESS. Ceiling Fan Application: -2ANF • Use to control one paddle-type ceiling fan (permanent split-capacitor). • Use the ceiling fan’s pull chain to set its speed to the highest setting. • Do not use to control fans that use shaded-pole motors (e.g., bath exhaust fans). • Do not use to control fans that have integrated fan speed controls (e.g., fans that have a remote control), unless the integrated control is removed from the ceiling fan. • Do not connect to any other motor-operated appliance or to any lighting load type. • Do not use to control a fan lighting load (e.g., light kit). Switch Load Type: • -8ANS and -8S-DV: designed for use with permanently installed 120 V~ incandescent, magnetic low-voltage, electronic low-voltage, tungsten halogen, fluorescent, CFL, LED, or motor loads. • -8S-DV can also be used with permanently installed 277 V~ magnetic low-voltage or fluorescent loads. Shunt Capacitor: Some -8S-DV installations may require the use of a shunt capacitor; this is especially necessary for load types sensitive to leakage current (e.g., fluorescent ballasts). If load flickers, install a shunt capacitor. Optional shunt capacitor must be installed inside the load fixture or in a separate J-box. For shunt capacitor installation see Wiring Diagram 4, 9, or 10.
www.lutron.com
7
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Mixing Lamp Types Mixing lamp types (using a combination of CFL/LED, and Incandescent/Halogen bulbs) and ganging with other dimmers or electronic switches may reduce maximum wattage as shown in the chart below. Example: If fins from one side of dimmer are removed and you have two 24 W bulbs installed (total CFL Wattage = 48 W), you may add up to 300 W of incandescent or halogen lighting. Do not remove outside fins on ends of ganged controls (shaded areas below) A
Total CFL/LED Wattage
HQRD-6CL1,2 0W 1 W – 25 W 26 W – 50 W 51 W – 75 W 76 W – 100 W 101 W – 125 W 126 W – 150 W 1 2
B
B
B
C
B
Total Incandescent/Halogen Wattage A B C Neutral Not Ganged End of Gang Middle of Gang Connection
+ + + + + + +
50 W – 600 W 0 W – 500 W 0 W – 400 W 0 W – 300 W 0 W – 200 W 0 W – 100 W 0W
Or Or Or Or Or Or Or
50 W – 500 W 0 W – 400 W 0 W – 300 W 0 W – 200 W 0 W – 100 W 0 W – 50 W 0W
Or Or Or Or Or Or Or
50 W – 400 W 0 W – 300 W 0 W – 200 W 0 W – 100 W 0 W – 50 W 0W 0W
No
Dimmer Load Type -6CL is designed for use with permanently-installed incandescent, CFL, LED, magnetic low-voltage, or tungsten halogen only. Do not install dimmers to control receptacles or motor-operated appliances. Do not mix CFL and LED loads with MLV loads.
Compatible Power Boosters and Load Interfaces Some local controls can be used to control power boosters or load interfaces. Up to three power boosters or load interfaces can be used with one control. See table below for a list of controls and compatible power boosters and load interfaces. Control
HQRD-6ND HQRD-10ND HQRD-6NA HQRD-F6AN-DV1
Phase Adaptive Power Modules: PHPM-PA-120-WH; PHPM-PA-DV-WH
9 9 9 9
3-wire Fluorescent Switched Power 0 – 10 V Interface and Power Modules: Module: Switching Module: PHPM-3F-120-WH; PHPM-SW-DV-WH GRX-TVI PHPM-3F-DV-WH
9 9 9 9
9 9 9 9 9
HQRD-8ANS 1
Only the GRX-TVI is compatible with the HQRD-F6AN-DV at 277 V~. All other power modules are 120 V~ only.
www.lutron.com
8
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Operation Dimmer Status LEDs (not on Remote Dimmers) Indicate light level; glow softly as night light when light is off Tapswitch Tap on / off Dimming Rocker Press to brighten Press to dim
FASSTM Front Accessible Service Switch
Switch Status LED (not on Remote Switches) Indicates load status; glows softly as night light when light is off Tapswitch Tap on / off
FASSTM Front Accessible Service Switch
Or
RD-277 and RS-277 only OFF
ON
Fan Speed Control Status LEDs Indicate speed level; glow softly as night light when fan is off Tapswitch Tap on / off Speed Control Rocker Press to increase speed Press to decrease speed
FASSTM Front Accessible Service Switch
www.lutron.com
9
Important Notice FASSTM: Front Accessible Service Switch To replace bulb, remove power by pulling the FASSTM switch out fully on all controlling devices. After replacing bulb(s), push the FASSTM switch(es) back in fully to restore power to the control(s). Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Wiring Diagrams Wiring Diagram 1 Single-Location Installation without Neutral1 -6CL, -6D, -10D
Wiring Diagram 2 Single-Location Installation with Neutral1 -6ND, -10ND, -6NA, -2ANF, -8ANS
Dimmer
Dimmer/Switch/Fan Speed Control Blue1
Brass
Blue1
Brass Silver Black
Black Hot/Live
Hot/Live Green
Green
120 V~ 50/60 Hz
120 V~ 50/60 Hz
Load
Ground
Ground
Neutral
Neutral
Wiring Diagram 3 Single-Location Fluorescent Dimmer Installation1 -F6AN-DV with Lutron® Ballast/LED Driver
Wiring Diagram 4 Single-Location 2-Wire Switch Installation1 -8S-DV with Optional Shunt Capacitor2
Dimmer
Switch Blue1
Brass Silver Black
Orange
Black
Brass
Lutron® Orange Ballast/LED White Driver
Optional
Hot/Live Green
Green 120 –277 V~ 50/60 Hz
120 –277 V~ 50/60 Hz
Black Ground
Lutron® Ballast/LED White Driver
Orange
Load
Shunt Capacitor2
Ground
Neutral
2
Blue1
Black
Hot/Live
1
Load
Neutral
Note: Bolded lines in diagrams indicate leads on products. When using controls in single-location installations, tighten the blue terminal. Do not connect the blue terminal to any other wiring or to ground. Optional Shunt Capacitor must be installed inside the load fixture or in a separate J-box.
Continued on next page...
www.lutron.com
10
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Wiring Diagrams (continued) Wiring Diagram 5 Multi-Location Installation without Neutral1 -6CL, -6D, and -10D with HQD-RD Remote Dimmer or Dimmer
Remote Dimmer or Dimmer
Dimmer or Remote Dimmer Note: Dimmer can be installed in any location in the circuit.
Brass
Blue
Black
Brass
Blue
Black
Brass
Blue
Black
Hot/Live Green
Green
Green
120 V~ 50/60 Hz
Load
Ground
Ground
Ground
Neutral
Wiring Diagram 6 Multi-Location Installation with Neutral1,2 -6ND, -10ND, -6NA, and -2ANF with HQD-RD; -8ANS with HQD-RS Remote Dimmer or Remote Switch
Brass
Blue
Black
Remote Dimmer or Remote Switch
Brass
Blue
Dimmer/Switch/Fan Speed Control2
Brass
Blue
Silver Black
Black
Hot/Live Green
Green
Green
120 V~ 50/60 Hz
Load
Ground
Ground
Ground
Neutral
1 2
Note: Bolded lines in diagrams indicate leads on products. Up to 9 Remote Dimmers/Remote Switches may be connected to the Dimmer/Switch/Fan Speed Controls. Total blue terminal wire length may be up to 250 ft (76 m). Neutral-Wire Dimmers/Switches/Fan Speed Controls must be connected on the Load side of a multi-location installation.
Continued on next page...
www.lutron.com
11
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Wiring Diagrams (continued) Wiring Diagram 7 Multi-Location Fluorescent Dimmer Installation1,2 (120 V~) -F6AN with HQD-RD and Lutron® Ballast/LED Driver Remote Dimmer
Brass
Blue
Black
Dimmer2
Remote Dimmer
Brass
Blue
Brass
Blue
Silver Black
Black
Black Lutron® Ballast/LED White Driver
Orange Orange
Hot/Live Green
Green
Green
120 V~ 50/60 Hz
Black Ground
Ground
Ground
Lutron® Ballast/LED White Driver
Orange
Neutral
Wiring Diagram 8 Multi-Location Fluorescent Dimmer Installation1,2 (277 V~) -F6AN with HQD-RD-277 and Lutron® Ballast/LED Driver Remote Dimmer
Red
Blue
Black
Dimmer2
Remote Dimmer
Red
Blue
Brass Silver Black
Black
Blue
Black Lutron® Ballast/LED White Driver
Orange Orange
Hot/Live Green
Green
Green
277 V~ 50/60 Hz
Black Ground
Ground
Ground
Lutron® Ballast/LED White Driver
Orange
Neutral
1 2
Note: Bolded lines in diagrams indicate leads on products. Up to 9 Remote Dimmers/Remote Switches may be connected to the Dimmer/Switch/Fan Speed Controls. Total blue terminal wire length may be up to 250 ft (76 m). Neutral-Wire Dimmers/Switches/Fan Speed Controls must be connected on the Load side of a multi-location installation.
Continued on next page...
www.lutron.com
12
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Wiring Diagrams (continued) Wiring Diagram 9 Multi-Location 2-Wire Switch Installation1 (120 V~) -8S-DV with HQD-RS and Optional Shunt Capacitor Remote Switch or Switch
Remote Switch or Switch
Switch or Remote Switch Note: Switch can be installed in any location in the circuit.
Brass
Blue
Black
Brass
Blue
Black
Brass
Blue
Black Optional
Hot/Live Green
Green
Green
120 V~ 50/60 Hz
Load
Ground
Ground
Shunt Capacitor2
Ground
Neutral
Wiring Diagram 10 Multi-Location 2-Wire Switch Installation1 (277 V~) -8S-DV with HQD-RS-277 and Optional Shunt Capacitor Remote Switch or Switch
Remote Switch or Switch
Switch or Remote Switch Note: Switch can be installed in any location in the circuit.
Red/Brass
Blue Red/Brass
Blue Brass/Red
Black
Black
Black
Blue
Optional
Hot/Live Green
Green
Green
277 V~ 50/60 Hz
Load
Ground
Ground
Shunt Capacitor2
Ground
Neutral
1 2
Note: Bolded lines in diagrams indicate leads on products. Up to 9 Remote Dimmers/Remote Switches may be connected to the Dimmer/Switch/Fan Speed Controls. Total blue terminal wire length may be up to 250 ft (76 m). Optional Shunt Capacitor must be installed inside the load fixture or in a separate J-box.
www.lutron.com
13
Technical Support — 800.523.9466 (USA)
product specifications
369305d
06.03.14
HomeWorks® QS Designer RF Maestro® Local Controls Colors and Finishes Gloss Finishes
Satin Finishes
White WH
Ivory IV
Hot HT
Merlot MR
Plum PL
Turquoise TQ
Almond AL
Light Almond LA
Taupe TP
Eggshell ES
Bizcocho BI
Snow SW
Gray GR
Brown BR
Palladium PD
Midnight MN
Sienna SI
Terracotta TC
Greenbriar GB
Bluestone BG
Mocha Stone MS
Goldstone GS
Desert Stone DS
Stone ST
Limestone LS
Black BL
• Due to printing limitations, colors and finishes shown cannot be guaranteed to perfectly match actual product colors. • Color chip keychains are available for more precise color matching: Gloss Finishes: DG-CK-1 Satin Finishes: SC-CK-1
Metal Finish (wallplate only) When using Stainless Steel wallplates, it is recommended that you order the control in Midnight (MN). Stainless Steel SS
www.lutron.com
14
Technical Support — 800.523.9466 (USA)