In-Line Fans

Report 0 Downloads 44 Views
Architectural & Engineering Specifications July 2011

In-Line Fans

DESCRIPTION • Remotely mounted fan reduces noise in occupied areas. • Use with adjustable inlet grilles to control flow for any situation.

MODELS ILF360, ILF530

• Remote mounting provides flexibility in system design. • High quality external rotor motor features long life, efficiency and quiet operation. • Easy mounting to rafters or joist. • Backward inclined centrifugal fan for strong air delivery with minimal noise.

DESIGN FEATURES Air Delivery:

Model ILF360: 360 cfm (170 L/s) at 0.2” Ps Model ILF530: 530 cfm (250 L/s) at 0.2” Ps

Sound Level:

N/A - unit is remotely mounted

TYPICAL INSTALLATION

Housing: Durable polycarbonate plastic Motor: External rotor, ball bearing, 115 VAC, 60Hz

ROOF CAP

Blower Wheel: Backward inclined centrifugal Duct Size:

Model ILF360: 8” (203 mm) diameter Model ILF530: 10” (254 mm) diameter

INSTALLATION • Not for use in cooking areas. • Not for use in wet locations. • Suitable for use over a tub or shower when connected to a GFCI-protected branch circuit. • Suitable for use with solid state speed controls.

FAN DAMPER / SLEEVE

• Housing mounts directly to bracket. Bracket mounts to rafter or joist. • Complete installation instructions included with each unit. • Switches and accessories available separately.

ARCHITECT’S SPECIFICATIONS Exhaust Fan shall be Model ILF360, ILF530 as manufactured by NuTone according to listed specifications.

GRILLE

Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948 Broan-NuTone Canada, Inc. Mississauga, Ontario www.nutone.ca 877-896-1119

REFERENCE

QTY.

REMARKS

Project









Location









Architect









Engineer









Contractor









Submitted by



Date 11G

99044773A

HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.2 in. static pressure, based on tests conducted in a state-of-the-art test laboratory.

AIR PERFORMANCE CURVE MODEL ILF360 (mm w.g.) (in. w.g.) 2.2

51

2.0

46

1.8

41

1.6

36 30 25 20

Static Pressure

56

8-in. (203 mm) duct • 360 cfm (170 L/s) @ 0.2” Static Pressure (Ps)

1.4 1.2 1.0 0.8

15

0.6

10

0.4

5

0.2

0

0.0 0

40

80

120

160

200

240

280

320

360

400

440

(cfm)

0

19

38

57

76

94

113

132

151

170

189

208

(L/s)

Model ILF360 only

Airflow

AIR PERFORMANCE CURVE MODEL ILF530 (mm w.g.) (in. w.g.) 2.8

66

2.6

61

2.4

56

2.2

51

2.0

46 41 36 30 25

Static Pressure

71

AMPS

10-in. (254 mm) duct • 530 cfm (250 L/s) @ 0.2” Static Pressure (Ps)



Model ILF360 ILF530

Amps 0.9 2.0

1.8 1.6 1.4 1.2

WATTS

1.0

20

0.8

15

0.6

10

0.4

5

0.2

0

0.0

0

53

106

159

212

265

318

371

424

477

530

583

(cfm)

0

25

50

75

100

125

150

175

200

225

250

275

(cfm)

Airflow

Model ILF360 ILF530

Watts 118 230