ACU-TROL® CHEMICAL CONTROLLER FOR POOL AND SPA MODEL AK600
INSTALLATION AND USER’S GUIDE Certified to NS F/ ANSI Standa
rd 50
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
CONTENTS SECTION 1
4
Information 4 IMPORTANT WARNING & SAFETY INSTRUCTIONS 4 &RQWUROOHU,QVWDOODWLRQ&RQ¿JXUDWLRQ ([SORGHG9LHZ Parts List 7 Controller CHEMICAL CONTROLLER OVERVIEW 8 TECHNICAL SUPPORT The Importance of Water Maintenance 9
SECTION 2 Installation
10
Installation Preparation 10 Installation Overview 13 0RXQWLQJWKH&RQWUROOHU 3OXPELQJ,QVWDOODWLRQ (OHFWULFDO,QVWDOODWLRQ ,QSXW9ROWDJH6HOHFWLRQ &RQWUROOHU,QVWDOODWLRQ&RQ¿JXUDWLRQ Exploded View 18 Parts List 19 &RQWUROOHU,QSXWV 2XWSXWV &KHPLFDO)HHG3XPS,QVWDOODWLRQ 6ROHQRLG/RFDWLRQ 8VLQJ$Q([LVWLQJ0DLQ7LPHU (URVLRQ)HHGHU/RFDWLRQ )ORZRU3UHVVXUH6ZLWFK
SECTION Hardware 22 0RGXOHV 6HQVRU0RGXOHV &RPPXQLFDWLRQ0RGXOHV 0HPRU\0RGXOH 5HOD\0RGXOHV 5HPRWH560RGXOHV
SECTION AK1200 Flow Cell $.)ORZ&HOO )ORZ&HOO$VVHPEO\ )ORZ&HOO0RXQWLQJ ,QOHWDQG([LW/LQHV 6HQVRUV
SECTION Sensors
29
26
SECTION 8 7KH&RQ¿JXUDWLRQ0HQX *HQHUDO6HWXS6FUHHQ *OREDO$ODUP *OREDO$ODUP'HOD\ 2YHUIHHG&OHDU7LPHV 0RGXOHRU1DPH %DFNOLJKW7LPH ')/%DFNOLJKW 'DWD6HWXS 7LPH6SDFLQJ 8VHG 1XPEHURI'D\V 'DWD/LQH 5HOD\2Q7LPHV,QGH[ (YHQW,QGH[ *UDSKLQJWKH(YHQW,QGH[ 6HQVRU6HWXS 7KH6\VWHP0HQX 7LPH 'DWH :HHNGD\ 8QLWV 3URJUDP0RGH9HUVLRQ'DQG+LJKHU +2$ 6HULDO1XPEHU 7KH6\VWHP0HQX6XE0HQXV +DUGZDUH&RQ¿JXUDWLRQ 'LVSOD\ 'LVSOD\6HWXS 3ULQWHU6HWXS 6HFXULW\ (QWHULQJD3DVVZRUG (QWHULQJD3DVVZRUG 5HVHW0HQX
SECTION 9 3URJUDPPLQJ
S+DQG2536HQVRUV S+DQG2536HQVRU&DUH )ORZ6HQVRUV 3UHVVXUH6HQVRUV )LQLVKLQJ\RXU,QVWDOODWLRQ
SECTION 6 Operations
32
0360RGXOHV 6HOHFW036WR&RQ¿JXUH 6HOHFW1HZ&RQ¿JXUDWLRQ 0RGLI\LQJ0366HWWLQJV6FUHHQ 7KH:L]%XWWRQ $ODUP&RQ¿JXUDWLRQ $XWRPDWLF6HW3RLQW$ODUPV 3DJHU9RLFH(PDLO$ODUPV &RPPXQLFDWLRQ 9RLFH&RPPXQLFDWLRQ 9RLFH&RPPXQLFDWLRQ0HQXV 9RLFH%XWWRQ 9RLFHV\VWHP7HVWLQJ PVE 79 3DJHU7HVWLQJ
,QWURGXFWLRQ 1DYLJDWLQJLQWKH&RQWUROOHU 6HOHFWLQJ,WHPV &KDQJLQJ,WHP9DOXHV 7KH$OSKDQXPHULF.H\ERDUG ,QLWLDOL]LQJWKH&RQWUROOHU
SECTION 7 The System Menu
36
7KH'LVSOD\0HQX 7KH6SHFL¿F'LVSOD\6FUHHQ 7KH'DWD'LVSOD\6FUHHQ 3URJUDPWKH'DWD5HFRUGLQJ,QWHUYDO 6XPPDU\'LVSOD\6FUHHQ 0367LPHUV ,QIRUPDWLRQ6FUHHQ
CONTENTS SECTION 11 Service
81
0DQXDO0362SHUDWLRQ &DOLEUDWLRQ S+&DOLEUDWLRQ 253&DOLEUDWLRQ 253&DOLEUDWLRQIRU/DUJH6\VWHPV &DOLEUDWLQJ&DOFXODWHG330 &DOLEUDWLQJ7HPSHUDWXUH &DOLEUDWLQJ'LJLWDO)ORZ &RQGXFWLYLW\6HWXS (QWHULQJD&\DQXULF$FLG0HDVXUHPHQW (QWHULQJDQ$ONDOLQLW\0HDVXUHPHQW (QWHULQJD7RWDO'LVVROOYHG6ROLGV0HDVXUHPHQW (QWHULQJD+DUGQHVV0HDVXUHPHQW *OREDO'LVDEOH Clear Overfeeds 97 Enter Password 98 7URXEOHVKRRWLQJ
SECTION 12 Optional Features
99
$.&RORU6HWXS Overvie 99 ([SDQVLRQ0RGXOHV Overview 100 $.&RORU&RQ¿JXUDWLRQ $.&RORU6HWXS $.&RORU'LDJQRVWLF6FUHHQ $.&RORU6WDUW8S &OHDQLQJWKH6HQVRU /RDGLQJWKH$.&RORU5HDJHQWV &DOLEUDWLRQ Preparation for Non-Operation 109 7URXEOHVKRRWLQJ 3305HDGLQJLVRU ,QWHUQDO5HG/('LVRQ&RQWLQXRXVO\ 7KH&OHDU9ROWDJHLV5HDGLQJ!9ROWV 7KH&OHDU9ROWDJHLV5HDGLQJ9ROWV '3'DQG&OHDU9RWDJHDUHWKH6DPH Chemicals Don't Last 110 ,QDFFXUDWH5HDGLQJV 1HWZRUN$. $.,QVWDOODWLRQ 6HWWLQJDQ$.$GGUHVV 2XWSXW6LJQDOV 0$6LJQDOV 0$6LJQDOV 96LJQDOV 5HYHUVLQJ (OHFWULFDO6SHFL¿FDWLRQV &RQWUROOHU1HWZRUN$.6HWXS 5HVHWWLQJ$.6HWXS &RQWUROOHU9LHZLQJ$.6HQVRUV )LQLVKLQJDQG7HVWLQJ 7URXEOHVKRRWLQJ
SECTION 13 Appendix
122
253&DOLEUDWLRQ&XUYHV 253&KHPLFDO6WDQGDUGV &DOFXODWHG330&DOLEUDWLRQ&XUYH 3URJUDPPLQJ&RPPDQG/LVW 3URJUDPPLQJ&RPPDQG/LVW 3URSRUWLRQDO)HHG*DLQ 036:L]DUGV 3URJUDPIRU6XSHU&KORULQDWLRQ 3URJUDPIRU'HFKORULQDWLRQ 3URJUDPIRU$XWR)LOO 3URJUDPIRUFKHPLFDO6WRUDJH 7DQN$XWR)LOO 3URJUDPIRUS+ 3URJUDPIRU330 3URJUDPIRU7HPSHUDWXUH
4
IMPORTANT WARNING AND SAFETY INSTRUCTIONS SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT IS NOT INSTALLED AND USED CORRECTLY. INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. Most states and local codes regulate the construction, installation, and operation of public pools and spas, and the construction of residential pools and spas. It is important to comply with these codes, many of which directly regulate the installation and use of this product. Consult your local building and health codes for more information. IMPORTANT NOTICE - Attention Installer: This Installation and User’s Guide (“Guide”) contains important information about the installation, operation and safe use of this product. This Guide should be given to the owner and/or operator of this product. DO NOT INSTALL THE CHEMICAL CONTROLLER WHERE IT CAN BE READILY ACCESSIBLE TO THE PUBLIC. Before installing this product, read and follow all warning notices and instructions in this Guide. Failure to follow warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for additional free copies of these instructions.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION: BEFORE WORKING ON THE CHEMICAL CONTROLLER: Always disconnect power to the controller at the circuit breaker before servicing. Failure to do so could result in death or serious injury to service person, pool users or others due to electric shock. BE SURE TO DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING.
This product must be installed by a licensed or certL¿HG electrician or a quali¿ed pool professional in accordance with the National Electrical Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.2. All applicable local installation codes and ordinances must also be adhered to. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property. BEFORE USING YOUR POOL, SPA OR HOT TUB, CHECK THE pH AND SANITIZER LEVELS OF THE WATER. Do not permit children to operate this equipment. When mixing acid with water, ALWAYS ADD ACID TO WATER. NEVER ADD WATER TO ACID. When adding any chemical to the pool/spa, be sure to follow the manufacturer’s instructions thoroughly. DO NOT MIX SODIUM HYPOCHLORITE AND MURATIC ACID
Risk of electrical shock. Connect the Chemical Controller to a ground-fault interruptercircuit (GFCI). Contact a TXDOL¿HG electrician if you cannot verify that the receptacle is protected by a GFCI. DISABLING THE OVERFEED TIMERS USING THE “CLEAR OVERFEED LIMITS” OR FLOW SWITCH WILL VOID NSF CERTIFICATION. IF “CLEAR OVERFEED LIMIT” SETTING IS SET TO 24 HOURS, DO NOT SET “FEED TIME” GREATER THAN 20 HOURS AS THIS WILL VOID NSF CERTIFICATION.
ACU-TROL® AK600 Chemical Controller Installation and User's Guide
5
IMPORTANT WARNING AND SAFETY INSTRUCTIONS WARNING CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the house before drilling into any pipes. Securely fasten all electrical, water and chemical lines. Locate chemical feed pumps and chemical storage tanks in a safe and secure area. Strictly follow the acid manufacturers safety and handling protocols including hand, body and eye protection when transferring or handling acid. Safety precautions should be used when handling Muriatic acid to control pH water levels. Muriatic acid can cause serious body injury and damage pool equipment. Extra care must be taken when installing, maintaining and operating acid pump feed systems. Acid is dangerous to handle and should be properly contained, transported, poured, stored, and dispensed.
Check the pH and sanitizer levels of the water before use. Periodically use an independent pH and Chlorine test kit to verify that pH and chlorine is at a safe level. If the pH and Oxidation Reduction Potential (ORP) or Flow Cell sensors are broken, depleted or dirty with oils, lotions, or other contaminants, they can report inaccurate results to the system causing incorrect water chemistry, which could harm people or equipment. Check the IntelliChem main status display each day to ensure there are no Alarm messages. See “Troubleshooting” section for more information.installing, maintaining and operating acid pump feed systems. Acid is dangerous to handle and should be properly contained, transported, poured, stored, and dispensed.
GENERAL WARNINGS AND SAFETY PRECATIONS PLEASE READ THIS USER MANUAL completely before installing or operating the equipment. The Controller Pool and Spa Chemical Controller is a Class 1 product for protection against electric shock and a Type 1 product with regards to disconnection of the control circuits. Be sure to observe the following safety precautions: t t t t t t t t t t
%POPUQFSNJUBOZPOFVOUSBJOFEPSVOEFSUIFBHFPGUPVTFUIJTQSPEVDU 6OJUNVTUCFQSPQFSMZHSPVOEFE 'SPOUQBOFMNVTUCFDMPTFECFGPSFQPXFSJTBQQMJFE "MXBZTUVSO0''NBJODJSDVJUCSFBLFSUPVOJUBOEBMMFRVJQNFOUCFGPSFTFSWJDJOH 5PVDIJOHUIFDPOUSPMMFSTJOUFSOBMQBSUTDPVMESFTVMUJOJOKVSZBOEPSEBNBHFUPUIFDPOUSPMMFS*ODBTFPGB malfunction, only a qualified technician should repair the controller. 3JTLPG&MFDUSJD4IPDL$POOFDUPOMZUPBHSPVOEJOHUZQFSFDFQUBDMFQSPUFDUFECZBHSPVOEGBVMUDJSDVJUJOUFSSVQUFS ('$* %POPUCVSZDPSE3PVUFDPSEUPFMJNJOBUFFYUFSOBMEBNBHF #FDBSFGVMOPUUPEBNBHFBOZPGUIFJOTVMBUJPOPOXJSFTPSUIFQPXFSDPSE4IPVMEUIFDPSECFEBNBHFE SFUVSOJUUPZPVSEFBMFSGPS a replacement. Continued use could result in fire or electric shock. 5PSFEVDFUIFSJTLPGFMFDUSJDTIPDL EPOPUVTFBOFYUFOTJPODPSEUPDPOOFDUVOJUUPFMFDUSJDTVQQMZ QSPWJEFB QSPQFSMZMPDBUFE('$* /FWFSSFNPWFPSJOTUBMMBOZDBCMFTPOUIFDJSDVJUDBSETXIFOQPXFSJTBQQMJFE EBNBHFUPUIFDPNQPOFOUTNBZ occur.
! WARNING
CHEMICAL BURN HAZARD 0DNHVXUHSXPSVDUH2))EHIRUHGULOOLQJLQWRSLSHV 6HFXUHO\IDVWHQDOOHOHFWULFDOZDWHUDQGFKHPLFDOOLQHV/RFDWHFKHPLFDOIHHG SXPSVDQGFKHPLFDOVWRUDJHWDQNVLQDVDIHDQGVHFXUHDUHD
! WARNING CHEMICAL HAZARD CONDITION '21277851&+(0,&$/)(('3803621:+(1%27+)/2: &(//9$/9(6$5(&/26(' $&8752/$.&KHPLFDO&RQWUROOHU,QVWDOODWLRQDQG8VHU V*XLGH
6
&RQWUROOHU&KHPLFDO&RQWUROOHU,QVWDOODWLRQ&RQ¿JXUDWLRQ Exploded View
!
WARNING )RU9$&3RZHUWKH&RQWUROOHU,QSXW9ROWDJH6HOHFWLRQ6ZLWFK0867EHFKDQJHGIURP 9$&WR9$&RUGDPDJHZLOORFFXUWRWKH&RQWUROOHU7KLVGDPDJHLV127FRYHUHGE\WKH ZDUUDQW\'R127FRQQHFWDQ\ORDGQRWUDWHGIRUWKHVXSSO\YROWDJHWRDQ\RIWKHVHUHOD\V
$&8752/$.&KHPLFDO&RQWUROOHU,QVWDOODWLRQDQG8VHU V*XLGH
7
Parts List DWG. #
PART #
1
DESCRIPTION Enclosure, Controller, lid, overlay, and hardware
2
714000720
Kit, Controller, Power Switch
3
755000190
Cord, Power, Controller, GFCI ** Not permitted in all areas**
4
714000110
Strain Relief, 5/8”, liquid tight
5
714000100
Strain Relif, 1/2”, liquid tight
6
724000120
PCB, Relay Board, Controller, 4 NO
7
724000130
PCB, Sensor, pH, ORP, Temp, 3 switch
8
724000090
PCB, Motherboard, Controller
9
724000100
PCB, Interface Board, Controller
10
724000110
Display, Touchscreen, Controller
11
Ribbon Cable, Controller
12
Relay board mounting screws
13
724000050
Socket, Relay NO(110/24/Dry)
14
714000120
Kit, latch, Integra Enclosure
725000020
Modem, Standard
735000010
Modem, Wireless
724000150
PCB, Sensor, Pressure, Temp
724000160
PCB, Sensor, pH, ORP, Cond, Temp
724000180
PCB, Sensor, pH, ORP, Color, Temp
724000190
PCB, Sensor, pH, ORP, Color, Cond, Temp.
724000060
Socket, Relay, NC (110/24/Dry)
Not Shown
ORP and pH Sensor Replacement Part Numbers ORP SENSOR PH SENSOR
P/N 744000340 P/N 744000260
ACU-TROL® AK600 Chemical Controller Installation and User's Guide
8
Controller CHEMICAL CONTROLLER OVERVIEW $FX7URODWHFKQRORJLFDOOHDGHULQVZLPPLQJSRRODXWRPDWLRQFRQJUDWXODWHV\RXRQ \RXUVHOHFWLRQRIWKH&RQWUROOHU&KHPLFDO&RQWUROOHU&RQWUROOHU VZLPPLQJSRRO FRQWUROOHU7KH&RQWUROOHUZLOOPDLQWDLQWKHS+DQGVDQLWL]HUOHYHOVPDLQWDLQDVHW WHPSHUDWXUHDQGFRQWUROXSWRH[WHUQDOGHYLFHVLQDSXPSURRPRQXSWRWKUHH SRROVRUVSDV7KH&RQWUROOHULVVSHFL¿FDOO\GHVLJQHGWREHHDV\WRXVHDQGLQVWDOO ZKLOHPHHWLQJWKHQHHGVRIWKHPRVWGHPDQGLQJDSSOLFDWLRQV The Controller Chemical Controller features: MODULAR DESIGN7KH&RQWUROOHULVGHVLJQHGWRJURZZLWK\RXUQHHGV ,QFUHDVHWKHQXPEHURIERGLHVRIZDWHUDGGWUXH330FRQWUROFRQGXFWLYLW\FRQWURO RUDGGDGGLWLRQDOUHOD\VWRDXWRPDWH\RXUSXPSURRP7KH&RQWUROOHUFDQEHHDVLO\ PRGL¿HGDWWKHLQVWDOODWLRQVLWHZLWKRQO\DIHZEDVLFWRROV INTERFACE7KH&RQWUROOHUXVHVDWRXFKVFUHHQGLVSOD\SDQHOZLWKDEXLOWLQ JUDSKLFDOXVHULQWHUIDFHIRUVLPSOHRSHUDWLRQ$IXOODOSKDQXPHULFNH\ERDUGLV DYDLODEOHIRUHDV\FDOLEUDWLRQDQGSURJUDPPLQJ$QDXWRPDWLFEDFNOLJKWHQVXUHVFOHDU YLVLELOLW\RIWKHWRXFKSDQHODQGFRQVHUYHVSRZHUE\WXUQLQJRQRQO\ZKHQWKHWRXFK VFUHHQLVLQXVH MEMORY7KH&RQWUROOHUKDVEXLOWLQPHPRU\WKDWDXWRPDWLFDOO\VDYHV\RXU SURJUDPPLQJ,I\RXUFRQWUROOHUHYHUORVHVSRZHULWZLOOUHWDLQDOOSURJUDPPHG YDOXHV DATA RECORDING7KH&RQWUROOHUKDVWKHDELOLW\WRUHFRUGGDWDIURPDOOVHQ VRUVDQGWRVWRUHXSWRPHDVXUHPHQWOLQHVWKHHTXLYDOHQWRIGD\VRIKRXUO\ UHFRUGLQJV CALCULATED READINGS7KH&RQWUROOHUFDOFXODWHVDQGGLVSOD\VWKHIUHH DYDLODEOHFKORULQHVFDOLQJLQGH[YDOXHVIRUHDFKERG\RIZDWHUDQGWZR GLIIHUHQ WLDOUHDGLQJVEDVHGRQWKHIRXU SUHVVXUHVHQVRUV RELAYS7KHDELOLW\WRFRQWUROXSWRUHOD\PRGXOHVHQDEOHVWKH&RQWUROOHUWR DXWRPDWHQHDUO\HYHU\GHYLFHLQ\RXUSXPSURRP7KHUHDUHYDULRXVW\SHVRIUHOD\ PRGXOHFRQ¿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¿JXUHGWRXVHHLWKHU9$&RU9$& 7KLVDOORZVWKHFRQWUROOHUWREHSOXJJHGLQWRDQH[LVWLQJRXWOHWRUZLUHGGLUHFWO\LQWR WKHHOHFWULFDOV\VWHP $&8752/$.&KHPLFDO&RQWUROOHU,QVWDOODWLRQDQG8VHU V*XLGH
9
7KH&RQWUROOHU,QVWDOODWLRQ2SHUDWLRQDQG3URJUDPPLQJ*XLGHH[SODLQVWKHSURFH GXUHVIRUSURSHULQVWDOODWLRQDQGRSHUDWLRQ6HFWLRQRQH WKHLQVWDOODWLRQJXLGH FRQVLVWVRI6HFWLRQVDQGDQGLQWURGXFHVWKHSDUWVRIWKHFRQWUROOHUDQGWKH SURFHVVWRIROORZZKHQLQVWDOOLQJWKHHOHFWULFDODQGSOXPELQJSRUWLRQV 6HFWLRQWZR WKHRSHUDWLRQJXLGHFRQVLVWVRI6HFWLRQDQGGHVFULEHVDOOWKHDYDLO DEOHVFUHHQVDQGPHQXVRIWKHFRQWUROOHUIURPQDYLJDWLQJDQGLQLWLDOL]LQJWKHVFUHHQV WRSURJUDPPLQJDQGFXVWRPL]LQJVSHFL¿FDWLRQV6HFWLRQWKUHH WKHSURJUDPPLQJ JXLGHFRQVLVWVRI6HFWLRQVDQGDQGGHVFULEHVWURXEOHVKRRWLQJ VWUDWHJLHVRSWLRQDOGHYLFHVWKDWPD\EHDGGHGWR\RXU&RQWUROOHUDQGPDQ\RIWKH UHOHYDQWFKDUWVDQGGLDJUDPV 7HFKQLFDO6XSSRUW Phone: (800) 831-7133 - Fax: (800) 284-4151 visit www.pentairpool.com and www.staritepool.com:
The Importance of Water Maintenance $FKHPLFDOFRQWUROOHULVGHVLJQHGWRPDLQWDLQVSHFL¿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
Filtration:0LQLPXPWXUQRYHUUDWHRIVL[KRXUVIRUDSRRODQG PLQXWHVIRUDVSD Water Balance:±S+±DONDOLQLW\330 2[LGDWLRQ5HGXFWLRQ3RWHQWLDO253 ±$UHDGLQJRIP9P9 Total Dissolved Solids6KRXOGQRWH[FHHG330 H[FOXGLQJSRROVXVLQJDVDOWFKORULQHJHQHUDWRU
7KLVLQIRUPDWLRQLVPHDQWWRSURYLGHSRRORSHUDWRUVZLWKDEDVLFLGHDRIWKH UDQJHRIZDWHUPDLQWHQDQFHUHTXLUHPHQWVDQGWKHLPSRUWDQFHRIZDWHUPDLQWHQDQFH 7RHQVXUHWKDW\RXUIDFLOLW\LVLQFRPSOLDQFHZLWKDOOORFDOUHJXODWLRQVSOHDVHFKHFN ZLWK\RXUORFDOKHDOWKGHSDUWPHQW $&8752/$.&KHPLFDO&RQWUROOHU,QVWDOODWLRQDQG8VHU V*XLGH
10
Section 2 Installation Installation Preparation $VVRRQDV\RXUFRQWUROOHULVGHOLYHUHGLQVSHFWWKHVKLSSLQJFDUWRQFDUHIXOO\IRU GDPDJH5HSRUWDQ\GDPDJHGLUHFWO\WRWKHVKLSSLQJFRPSDQ\&RPSDUHWKH SDFNLQJOLVWWRWKHFRQWHQWVRIWKHFDUWRQ,IDQ\WKLQJLVPLVVLQJFRQWDFW\RXUORFDO $FX7UROGHDOHU8VHFDUHZKHQXQSDFNLQJHTXLSPHQWWRDYRLGGDPDJHRUORVVRI VPDOOSDUWV :HVWURQJO\UHFRPPHQGWKDW\RXSODQRXWWKHSRROURRPOD\RXWEHIRUH\RXLQVWDOO WKH&RQWUROOHU&KHPLFDO&RQWUROOHU)LJXUHLVDVDPSOHRIDSRROURRPOD\RXW