Ledex® Box Frame Size B17-L — DC Operation

Report 8 Downloads 20 Views
Ledex® Box Frame Size B17-L — DC Operation Magnetic Latching

All catalog products manufactured after April 1, 2006 are RoHS Compliant

Part Number: B17 - L - X XX - B- 3 Coil Selection (from performance chart below) Pole Configuration 1 Flat Face

Well-suited for battery operation.

Specifications Operation Dielectric Strength Unlatch Voltage Magnet Hold Force* Coil Insulation

See the "Battery Operated Solenoids" section for complete information.

Typical Force @ 20°C (Net, with Spring) 30.0 (8.4) 25.0 (7.0)

Force - oz (N)

Pull 500 VRMS for one second See schematic and coil data below 10 oz. (with return spring) Class “ B”: 130°C max. (standard); other temperature classes available Coil Termination 10" PVC lead wires Spring Force 16.0 oz/in; 2.4 oz latched position Plunger Pole Face Flat face (other options available) Plunger Weight 0.08 oz. (2.46 g) Total Weight 0.70 oz. (19.85 g) Dimensions See page H38 *In no power, latched position.

Performance 25%

10%

Maximum ON Time (sec)

n/a

112

36

10.5

Watts (@ 20°C)

1.6

3.2

6.4

16

Ampere Turns (@ 20°C)

292

414

584

923

20.0 (5.6) 15.0 (4.2) 10.0 (2.8) 5.0 (1.4) 0

0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 (0.51) (1.02) (1.52) (2.03) (2.54) (3.05) (3.56) (4.06) (4.57)

Stroke - in (mm)

Coil Data Part Number

Resistance Ref # Unlatch VDC VDC VDC (@20°C) Turns VDC (Nom) (Nom) (Nom)

B17-L-158-B-3 B17-L-155-B-3 B17-L-156-B-3 B17-L-154-B-3 B17-L-153-B-3 B17-L-152-B-3

5.40 21.93 50.20 88.95 337.00 1465.00

556 1112 1540 2208 3687 9177

3 6 9 12 24 48

4 8.5 12 17 34 68

6 12 18 24 48 96

NOTES:

Coil Polarity

A

Latch: A+ B- Unlatch: A- B+

9 19 28.3 38 76 153

(Red)

B

(Black)

How to Order

1. All data is typical. 2. Force testing is done with the solenoid in the horizontal position. 3. All data reflects operation with no heatsink.

Select the part number from the table provided. (For example, to order a 25% duty cycle unit rated at 48 VDC, specify B17-L-153-B-3. Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors.

Force values for reference only.

All specifications subject to change without notice.

Ledex® Solenoids

H15

www.ledex.com

1.937.454.2345

Fax: 1.937.898.8624

LINEAR Open Frame

Unlatched Maximum Duty Cycle Voltage 50%

10% Duty Cycle 25% Duty Cycle 50% Duty Cycle

Ledex® Box Frame Dimensions Inches (mm) All solenoids are illustrated in energized state

B17 (3) #4-40 UNC threads

Plunger Detail 0.062 (1.57)

0.312 ± 0.025 (7.92 ± 0.635)

0.188 ± 0.010 (4.78 ± 0.254)

0.315 ± 0.008 (8.0 ± 0.203) 0.512 ± 0.015 (13.0 ± 0.381) 0.276 ± 0.008 (7.01 ± 0.203)

0.079 (2.01)

0.062 ± 0.003 (1.57 ± 0.076) Dia.

0.190 ± 0.003 (4.83 ± 0.076)

0.594 ± 0.015 (15.08 ± 0.381) #26 AWG PVC Lead Wires 0.787 ± 0.015 (19.99 ± 0.381)

10.0 (254) Min.

0.945 ± 0.030 (24.0 ± 0.762)

B17-L

LINEAR Open Frame

0.062 (1.57)

0.079 (2.01)

0.190 ± 0.003 (4.83 ± 0.076) Dia.

0.188 ± 0.010 (4.78 ± 0.254)

0.470 ± 0.025 (11.94 ± 0.635)

0.315 ± 0.008 (8.00 ± 0.203)

0.512 ± 0.015 (13.0 ± 0.381)

0.152 ± 0.007 (3.86 ± 0.178) 0.029 + (0.74 + -

Plunger Detail

0.276 ± 0.008 (7.01 ± 0.203)

0.003 0.000 0.076 0.000)

Ø0.062 + (1.58 + -

0.003 0.000 0.076 0.000)

See Plunger Detail

#4-40 UNC Thds (3 Holes)

0.787 ± 0.015 (19.99 ± 0.381) E-Ring #26 AWG PVC Lead Wires

0.594 ± 0.015 (15.09 ± 0.381)

Black Red

Spring 1.120 ± 0.030 (28.45 ± 0.762)

10.0 Min. (254)

All specifications subject to change without notice.

Ledex® Solenoids

H38

www.ledex.com

1.937.454.2345

Fax: 1.937.898.8624