Ledex® C Frame Size C5 — DC Operation

Report 3 Downloads 25 Views
Ledex® C Frame Size C5 — DC Operation Part Number: C5 - XXX - B- 1

All catalog products manufactured after April 1, 2006 are RoHS Compliant Select from performance chart below Well-suited for battery operation.

Specifications Operation Dieletectric Strength Continuous Duty Cycle Intermittent Duty Cycle Coil Insulation Coil Termination Plunger Pole Face Plunger Weight Total Weight Dimensions

Pull 500 VRMS for one second 100% At 20°C ambient temperature See below Class “B”: 130°C max. temperature standard. Other temperature classes are available 0.025" square pin terminals 60° conical 0.08 oz. (2.2 g) 0.42 oz. (11.9 g) See page H44

See the "Battery Operated Solenoids" section for complete information.

Force (Gross, Without Spring) 1.4 (6.23)

1.2 (5.34)

Maximum Duty Cycle

100%

50%

25%

10%

Maximum ON Time (sec)



145

47

14

Watts (@ 20°C)

3

6

12

30

Ampere Turns (@ 20°C)

422

564

844

1268

Force - lbs (N)

Performance

2.88 11.52 25.77 48.65 72.84 152.20 191.73

406 795 1222 1642 1968 2860 3202

3 6 9 12 15 21 24

4 8 12 17 21 30 34

6 12 18 24 30 43 48

NOTES: 1. All data is typical. 2. Force testing is done with the solenoid in the horizontal position. 3. All data reflects operation with no heatsink. 4. Other coil terminations available. 5. Pull versions standard; push versions available.

Force values for reference only.

Ledex® Solenoids

9 19 28 38 47 68 76

0.6 (2.67)

0.4 (1.78)

Resistance Ref # VDC VDC VDC VDC (@20°C) Turns (Nom) (Nom) (Nom) (Nom)

C5-273-B-1 C5-272-B-1 C5-271-B-1 C5-270-B-1 C5-269-B-1 C5-268-B-1 C5-267-B-1

0.8 (3.56)

0.2 (0.89)

0

0

0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20 (0.51) (1.02) (1.52) (2.03) (2.54) (3.05) (3.56) (4.06) (4.57) (5.08)

Stroke - in (mm)

How to Order Select the part number from the table provided. (For example, to order a 25% duty cycle unit rated at 48 VDC, specify C5-267-B-1. Please see www.ledex.com (click on Stock Products tab) for our list of stock products available through our North American distributors.

All specifications subject to change without notice. H25

www.ledex.com

1.937.454.2345

Fax: 1.937.898.8624

LINEAR Open Frame

Coil Data Part Number

10% Duty Cycle 25% Duty Cycle 50% Duty Cycle 100% Duty Cycle

1.0 (4.45)

Ledex® C Frame Dimensions Inches (mm) All solenoids are illustrated in energized state

C5 Terminals 0.025 (0.64) Square terminals "A" This side "B" Back Side B

1.24 (31.5)

0.8 (20.3)

A

0.312 (7.93) Ref.

0.362 (9.2) 0.04 (1.0)

0.035 (0.9)

0.2 (5.0) 0.42 (10.6)

0.46 (11.7)

0.23 (5.8) 0.41 (10.4)

0.94 (23.8)

0.5 (12.7)

0.22 (5.6)

B

A

A

B

0.14 (3.6)

0.28 (7.1)

0.07 (1.8)

Ø0.16 (4.0) Ø0.063 +0.003 (1.6 +0.08)

M2 X 0.4 Thru (2) Holes "A"

1-72 UNF-2B Thru (2) Holes "B"

LINEAR Open Frame

C5-L Terminals 0.64 Square terminals "A" This side "B" Back Side B

31.5 20.3

A

7.93 Ref.

9.2 1.0

0.9

5.0 10.6

11.7 5.8 3.2

10.4

Ø4.0

23.8 12.7

1.8

5.6 Ø1.6 +0.08

3.6

B

A

A

B

7.1

M2 X 0.4 Thru (2) Holes "A"

1-72 UNF-2B Thru (2) Holes "B"

All specifications subject to change without notice.

Ledex® Solenoids

H44

www.ledex.com

1.937.454.2345

Fax: 1.937.898.8624