LnT MU G75 Catalogue

Report 4 Downloads 73 Views
Spares Cat. No.

Std. Pkg. (Nos.)

Contactor ML 6W

CS90168LOOO

1

ML 6W Spare Coil 380 V, 50 Hz

CS90169LOOO

1

Cat. No.

Std. Pkg. (Nos.)

MN5 Relay (45-75 A)

SS94137OOJO

1

MN5 Relay (66-110 A)

SS94137OOKO

1

Cat. No.

Std. Pkg. (Nos.)

Spare Wiring Harness

CS90171OOOO

1

Terminal Block (125 A) (3 way)

CS90172OOOO

1

Volt-Ammeter 500 V 60 A (CT operated)

CS94817EOTO

1

Indicating Lamp Red 415 V

CS94810DOOO

1

Indicating Lamp Green 415 V

CS94812DOOO

1

Cat. No.

Std. Pkg. (Nos.)

360 V SPPR Type SDz5

XM81808OOOO

1

380 V SPPR Type SDz5

XM80703OOOO

1

415 V SPPR Type SDz5

XM81809OOOO

1

Description

Description

MN 5

Description

Indicating Lamp Red & Green

Volt-Ammeter

Description

SPPR Type SDz5

Product improvement is a continuous process. For the latest information and special applications, please contact our nearest branch office. Larsen & Toubro Limited Electrical Standard Products Powai Campus, Mumbai 400 072 Customer Interaction Center (CIC) BSNL / MTNL (toll free) : 1800 233 5858 Reliance (toll free) : 1800 200 5858 Tel : 022 6774 5858, Fax : 022 6774 5859 E-mail : [email protected] Website : www.LNTEBG.com

MU-G75 Three - Phase Submersible Pump Controllers SP 50609

MU-G75

Features and Application of MU-G75 Submersible Pump Controller

Features: Protection from single – phasing Protection from overload conditions Protection from phase reversal Protection from phase unbalance 55 V (+/-5 V) Proven & tested ML contactors Wideband coil operates from 65% to 110% of rated coil voltage (e.g. 380 V Coil operated from 247 V to 418 V)

Range:

Indication of healthy supply indication Auto Restart (with 30 sec ON Delay) Power ON & Pump ON indication Unique Dual Volt-Ammeter & Ammeter Easy replacement of spares Terminal block for easy termination

Typical Applications: Borewell submersible water pump

MU-G75 Star-Delta – upto 75 HP

Ordering Details for MU-G75 Star-Delta Controller Type

Pump Rating at 415 V, 3 Ph, 50 Hz

MU-G75 Star-Delta

HP

kW

With Relay Range (A)

75

55

45-75

CS96451LOJO

1

75

55

66-110

CS96451LOKO

1

Catalogue No. Coil Voltage 380 V

Std. Pkg. (Nos.)

MU-G75 450

Mounting Holes Suitable for M8 Screw

ML 6W (Wide band)

Coil Voltage

380 V

Overload Relay

MN 5

Relay Range

45-75 A and 66-110 A

Pick-up voltage

65% to 110% Uc

Drop-off voltage

25% to 35% Uc

OFF

812

Contactor

780

75 HP

740

Rating

600

Technical Details for MU-G75 Star-Delta Controller

ON

Ammeter with CT

Additional Protection Offered Indicating Lamps

Voltmeter with selector switch Single phasing, Phase reversal Phase unbalance (55±5 V) Supply ON

90

Measurement offered

MU-G75

Pump ON

Rated Insulation Voltage

690 V

Rated Operational Voltage

415 V AC o

560 600 o

Service Temperature

-5 C to 55 C

Conformity to Standard

IS/IEC60947-4-1

Terminal Capacity

50 Sq. mm. with Lug (Lugs provided inside MU-G Controller)

Degree of Protection

IP42

No. of full Start

30 operations per hour

Back-up protection

Type 2 with HN Fuses

636

8 174.6 207.8

Note: All dimensions are in mm.