low voltage relay station - din - Vantage Controls

Report 2 Downloads 99 Views
LOW VOLTAGE RELAY STATION - DIN Load Controls

The Vantage DIN Low Voltage Relay Station is a powerful control point for systems or devices that operate through low voltage relay control. A DIN LVRS includes eight SPDT relays to control devices such as draperies, pumps, garage doors, lifts, screens, pool covers, sprinklers, baths, security systems and more. Each relay corresponds to an individual button on the front of the unit, which allows the connected device to be manually switched. The individual relays “latch” to retain the last state in the event of a power interrupt. Low Voltage Relay Stations, available in WireLink or RadioLink, easily install on standard 35mm DIN rails. The stations communicate with the controller either through a WireLink two-wire bus or wireless RadioLink. Each station can quickly become part of Vantage’s powerful scene orchestration capabilities with user friendly programming software.

Product Highlights • Provides a single integration point for up to eight relay channels • Allows effortless control of devices such as draperies, pumps, garage doors, lifts, screens, pool covers, sprinklers, security systems, and much more • Clips easily on standard 35mm DIN rails • Accepts programming using Vantage’s InFusion Design Center or QLink software • Communicates with the controller via WireLink or RadioLink • Features eight buttons to manually control each relay

Low Voltage Relay Station - DIN RadioLink Low Voltage Relay Station - DIN (STOLER821) with RadioLink

STOLER821

NON POLARIZED

SERIAL NUMBER

9-12V AC/DC 200mA IN

OPEN ENERGY MANAGEMENT EQUIPMENT 51XT

60mm

WireLink Low Voltage Relay Station - DIN (LVRS8-DIN)

STATION BUS CLASS 2

LVRS8-DIN

SERIAL NUMBER OPEN ENERGY MANAGEMENT EQUIPMENT 51XT

SIDE VIEW 96mm

SET

1

2

3

4

5

6

7

8

RESET

COM

8 SET

RESET

COM

7 SET

COM

RESET

STATUS

6 SET

RESET

COM

5 SET

RESET

COM

4 SET

RESET

COM

3 SET

RESET

COM

2 SET

COM

SET

1

RESET

LOW VOLTAGE RELAY STATION 8 - DIN

MAX RATINGS 1AMP 48VAC 30VDC

157mm FRONT VIEW

TOP VIEW

Specifications Dimensions, HWD

86mm x 157mm x 60mm



3.4” x 6.18” x 2.375”

General Specifications Models

LVRS8-DIN (WireLink) / STOLER821 (RadioLink)

Weight

201 g (8.04 oz)

Mounting

35mm DIN Rail (EN 50 022: 1977)

Ambient Operating Humidity

5-95% non-condensing

Ambient Operating Temperature

0°-40° C (32°-104° F)

Lightning Surge Protection Low Voltage

ITU-T K.20

Number of Relay Actuators

8

Number of SPDT Relays

8

Maximum Current at Relay

1A

Maximum Voltage at Relay

48 VAC / 30 VDC

Software Requirements RadioLink

InFusion Design Center or QLink version 4.0 or higher

Software Requirements WireLink

InFusion Design Center or QLink version 3.5 or higher

Station Equivalent InFusion

0.5W on IC-24 / 0.5W on IC-36

Station Equivalent QLink

1 Station on QLink Main Controller

Wiring Specifications Station Bus Wiring Minimum

2 conductor, 16 AWG stranded, non-shielded twisted pair, 30 pF/foot max, UL rated CL2

Station Bus Topology

Any combination of daisy chain or star or branch or home run

RadioLink RF Specifications Station Equivalent

1 RF station

FCC ID#

PII-VSUB075-1

IC

3505A-VSUB0751

Frequency Range

902–928 MHz ISM band

RF Technology

Frequency hopping spread spectrum

Number of Channels

25

System Compatibility InFusion QLink

1061 South 800 East

Orem, Utah 84097

800.555.9891

801.224.0355 fax

www.vantagecontrols.com