LUN HO
Enclosed and Gasketed Fiberglass Industrial High Output / 1 or 2-Lamp T5HO, T8, T12 Project Information Project Name
Type
Catalog No.
Date
Electrical
Features
Liner
Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. All ballast leads extend a minimum of 6" through access location. NEC/CEC-compliant ballast disconnect is standard.
• Non-metallic enclosure resists the destructive effects of most corrosive agents • Smooth surfaces of housing and diffuser lens make cleaning easy. Housing and lens have no seams or crevices to trap dirt and dust • Fixture housing has an inverted “U” slot which allows the diffuser to nest tightly, shedding water • Neoprene gasketing is sandwiched between housing and diffuser forming an effective seal • Diffuser lens is secured to the housing with captive, nonmetallic, snap-action cam latches • Full steel liner for ballast heat dissipation and maximum reflectivity • Ballast cover plates snap-lock without tools; eliminates loose hardware or fasteners • UL listed 1958, cUL or CSA. Wet Location standard
Heavy gauge die-formed steel. Finish
Housing - Cream tone fiberglass. Liner - Pre-painted high gloss baked white enamel, minimum 86% reflectance.
Housing
One-piece, high-impact, molded polyester fiberglass with a cast waterproof hub (1⁄2" thread). Factory installed neoprene gasketing.
Certification
All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Wet location labeling is standard. Emergency-equipped fixtures labeled UL 924.
Diffuser
One-piece, impact-resistant 15% DR, molded acrylic. Smooth outside, prismatic pattern inside. Retained by molded ABS thermoplastic latches.
Ordering Information LUN
Example LUN8-296HO-EPU
–
Model
–
No. of Lamps in Cross section
LUN Enclosed and Gasketed Fiberglass Industrial
1 One 2 Two
Size 4 4' 8 8'
– Ballast
Voltage
EP Electronic, Programmed Start (std.) 4EP 4-lamp Electronic, Programmed Start (only available on T5HO)
U 120V-277V 347 347V
Options GLR PP DR TP SSL SSLTP PAF EL
Fast Blow Fuse Prismatic Polycarbonate Lens 50% DR Acrylic Lens Tamper Resistant Latches Stainless Steel Latches Tamper Resistant Stainless Steel Latches Paint After Fabrication Emergency Battery Pack (Not available with Wet Location) NYC NYC Compliant NYCU NYC Compliant, Union Label
Lamp Type 48HO 48T8HO 54 96HO 96T8HO
4', T12: 60 Watt 4', T8: 44 Watt 4', T5HO: 54 Watt 8', T12: 110 or 95 Watt 8', T8: 86 Watt
Accessories (Order Separately) HUBK LUNHK PEBU PEBA
Page 1/3 Rev. 09/06/11
Stem Hanging Hubs Stainless Steel Hanging Kit For 1/2" Hubs, Chain Not Included End Bracket Universal Surface Mount Kit Adjustable Surface Mount Bracket Kit
Extreme Environment / LUN HO
© 2011 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
LUN HO
Enclosed and Gasketed Fiberglass Industrial High Output / 1 or 2-Lamp T5HO, T8, T12 AVG. Luminance (Candela/Sq. M.) 0.0 22.5 45.0 67.5 90.0
Luminaire
Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting
LUN4-248T8HO LUN Industrial 8" × 50" 2-Lamp with Clear Stippled Acrylic Lens B286I120RH 0.85 F48T8HO 4000 73 Surface
0 30 40 45 50 55 60 65 70 75 80 85
5221 4908 4700 4547 4339 4059 3705 3303 2881 2473 2087 1708
5221 4798 4635 4524 4367 4156 3874 3550 3242 3033 3030 3098
5221 4947 4890 4806 4677 4507 4333 4195 4225 4554 4781 4470
5221 5050 5018 4963 4903 4835 4773 4837 5135 5417 5338 4914
0º = 1.25 90º = 1.56 Length = 4.14 Width = 0.62 Height = 0.25
Zone
Lumens
Lamp
Fixt.
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
1036 1762 3358 5103 789 842 865 869 5972
13.0 22.0 42.0 63.8 9.9 10.5 10.8 10.9 74.7
17.4 29.5 56.2 85.4 13.2 14.1 14.5 14.6 100.0
Test 13953 Test Date 5/19/05
Coefficients of Utilization (%)
5221 5130 5121 5101 5081 5043 5032 5188 5509 5725 5555 5190
Zonal Lumen Summary
0º = 90 90º = 90
Shielding Angle Spacing Criterion Luminous Opening in Feet
Average Luminance Angle
Luminaire Data
RCR
Photometric Data
RC RW 1 2 3 4 5 6 7 8 9 10
70 76 69 62 56 52 48 44 41 38 36
80 50 30 72 68 61 55 53 46 47 40 41 34 37 30 33 26 30 24 28 21 25 19
10 64 51 41 34 29 25 22 19 17 15
70 50 30 69 65 59 54 51 45 45 38 40 33 36 29 32 26 29 23 27 21 25 19
70 73 65 59 54 49 45 42 39 36 34
10 62 49 40 33 28 24 21 19 17 15
50 64 55 47 42 37 33 30 27 25 23
Indoor Candela Plot 50 30 61 50 42 36 31 27 24 22 20 18
10 58 46 38 32 27 23 20 18 16 14
0 0 49 39 32 26 22 19 17 15 13 12
180
165
120
105
90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
650
Energy Data
60
Total Luminaire Efficiency
74.7%
Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
70 Non-Compliant $3.43 based on 3000 hrs. and $0.08 per KWH
1300 0
15
230 N/A
0 30 40 45 50 55 60 65 70 75 80 85
5428 5179 4964 4800 4576 4296 3946 3567 3178 2775 2364 1950
5428 5101 4932 4810 4631 4409 4146 3863 3581 3337 3123 2946
5428 5222 5160 5100 5024 4925 4788 4654 4556 4492 4402 4443
5428 5312 5345 5369 5373 5333 5246 5162 5091 5029 5020 5143
5428 5350 5435 5483 5512 5483 5403 5317 5249 5201 5230 5369
Zonal Lumen Summary
0º = 1.24 90º = 1.53 Length = 8.09 Width = 0.58 Height = 0.00
Zone
Lumens
Lamp
Fixt.
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
1955 3309 6282 9226 1567 1712 1770 1776 11002
11.1 18.8 35.7 52.4 8.9 9.7 10.1 10.1 62.5
17.8 30.1 57.1 83.9 14.2 15.6 16.1 16.1 100.0
90.0
Test 11246 Test Date 1/8/03
Coefficients of Utilization (%)
RCR
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
LUN8-296HO LUN Industrial 8" × 98" 2-Lamp Tandem with Clear Stippled Plastic Wrap Enclosure 480-X-LH-TC-P 0.95 F96T12HO 8800
45
30 Horiz 0-180
45.0
0.0
0.0 22.5 45.0 67.5 90.0
Average Luminance Angle
Luminaire
135
650
AVG. Luminance (Candela/Sq. M.) Luminaire Data
150
1300
RC RW 1 2 3 4 5 6 7 8 9 10
70 64 58 52 48 44 40 37 34 32 30
80 50 30 61 57 52 47 45 39 40 34 35 29 31 26 28 23 26 20 23 18 22 16
10 54 43 35 29 25 21 19 16 15 13
70 61 55 50 45 41 38 35 33 31 29
70 50 30 58 55 50 45 43 38 38 33 34 28 30 25 27 22 25 20 23 18 21 16
10 53 42 34 28 24 21 18 16 14 13
50 54 46 40 35 31 28 25 23 21 20
50 30 51 42 36 31 27 23 21 19 17 15
10 49 39 32 27 23 20 17 15 14 12
Indoor Candela Plot
0 0 41 33 27 22 19 16 14 13 11 10
180
165
150
135
2600
120 1300
105
90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
1300
Energy Data
60
Total Luminaire Efficiency
62.5%
Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
45 Non-Compliant $5.33 based on 3000 hrs. and $0.08 per KWH
2600 0
15
45
30 Horiz 0-180
0.0
45.0
90.0
Dimensional Data D B 11/16" K.O.
7/8" K.O. E
C A
CAUTION: High output LUN fixtures should not be surface mounted or installed in areas of high ambient temperatures. To reduce risk of ballast cycling, LE ballasts are recommended.
Page 2/3 Rev. 09/06/11
NOTE:
Catalog Number
A
B
C
D
E
LUN4 LUN8
59/16" 59/16"
79/16" 79/16"
3" 3"
411/2" 891/2"
4913/16" 9713/16"
Fixtures are designed for ceiling mounting only. All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Extreme Environment / LUN HO
© 2011 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
LUN HO
Surface Mounting Details For LUN, FNPV, FNPS, LU
PEBU Accessory1
0.31" × 1.75" SLOT
D 0.312" E 4.50"
3.12"
1.00"
0.31" × 1.69" SLOT
PEBA Accessory2
0.22"
G
3.12"
90° Adjustments
F
D
E
F
G
2'
25.75" (654 mm)
0" (0 mm)
25.75" (654 mm)
2.38" (60 mm)
4'
49.75" (1264 mm)
0.38 (10 mm)
49.75" (1264 mm)
2.75" (70 mm)
8'
97.75" (2483 mm)
0.38" (10 mm)
97.75" (2483 mm)
2.75 (70 mm)
For FDPS, FDPH, FNPS, FNPV
PTBS Accessory3 D
0.44" × 0.89" SLOT
E 0.75"
7.12"
PTBA Accessory4
90° Adjustments 15° Increments
F
0.31"
G
2.38"
1.38" D
E
F
G
4'
45.65" (1118 mm)
—
48.40" (1186 mm)
—
8'
93.65" (2294 mm)
46.83" (1147 mm)
96.40" (2362 mm)
46.83 (1147 mm)
PEBU is for 3/4" hubs, PEBUHSMS is for 1/2" hubs. 2 PEBA is for 3/4" hubs, PEBAHSMS is for 1/2" hubs. 3 PTBS has two mounting brackets; PTBS3 has three mounting brackets and only used with 8' fixtures. 4 PTBA has two mounting brackets; PTBA3 has three mounting brackets and only used with 8' fixtures. 1
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 3/3 Rev. 09/06/11
Extreme Environment / LUN HO
© 2011 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com