EC Type Examination Certificate Number: 0120/SGS0204

Shenzhen Chuangren Technology Co Ltd Building 33, No. 3 Industrial Area Mashantou, Gongming Street, New Guangming District, Shenzhen City Guangdong Province, 518106, China Instrument Identification: DSZ12E-3X80A, DSZ12D-3X80A, DSZ12A=3X80A Instrument Traceable Number 0120/ SGS0204 Poly phase, Active Import/Export (kWh), Electricity Meter has been assessed and certified as meeting the requirements of

EC Directive 2014/32/EU on Measuring Instruments Annex II, Module B It is certified that the manufacturer’s technical design and specimen for the above instrument has been examined and, based on the evidence submitted, it is considered that the instrument conforms to the requirements of Annex V of EC Directive 2014/32/EU This certificate must be used in conjunction with a certificate covering the product verification as required in Annex II, Module D or Annex II, Module F th

th

This certificate is valid for 10 years from 29 April 2016 until 28 April 2026 Issue 2 th

Certification is based on report number(s) SHES150800499601 dated 29 April 2016

Authorised Signature Jan Saunders

SGS United Kingdom Limited, Notified Body 0120 Unit 202B Worle Parkway, Weston-super-Mare, BS22 6WA□UK t +44 (0)1934 522917 f +44 (0)1934 522137 www.sgs.com Contact Address SGS United Kingdom Ltd, Units 12A & 12B, South Industrial Estate, Bowburn, Durham, DH6 5AD□UK t +44 (0)191 377 2000 f +44 (0)191 377 2020 www.sgs.com

MID-B06E Rev 8

EC Type Examination Cert. Page 1 of 6

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2 1.

Dated: 20th May 2016

Technical Data

Manufacturer Meter Type(s)

Shenzhen Chuangren Technology Co Ltd DSZ12E-3X80A, DSZ12D-3X80A, DSZ12A-3X80A

Voltage Rating (Un)

3 x 230/400V

Current Rating (Imin – Iref (Imax))

DSZ12E: 0.25-5(80)A DSZ12D: 0.5-10(80)A DSZ12A: 0.5-10(80)A

Frequency (Fn)

50Hz

Active Accuracy Class (kWh)

B (kWh)

Type of circuit

3p4w o

o

Temperature Range

-25 C to +55 C

Software/ Firmware Version No

DSZ12D: 723C DSZ12E: 709F DSZ12A: 723C LCD

Identification Location Bill Of Materials Number

IP Rating

DSZ12D V0 DSZ12E V0 DSZ12A V0 The meter casing is only IP50 complaint. Therefore the meter MUST always be fitted into an IP51 approved enclosure.

Insulation Protective Class

Class II

LED Pulse Constant

DSZ12E: 800 imp/kWh DSZ12D LED tariff – 100 imp/kWh DSZ12D S0-output – 1000imp/kWh DSZ12A LED tariff – 100 imp/kWh DSZ12A S0-output – 1000imp/kWh

Impulse Voltage Rating

6kV

AC Voltage Rating

4kV

Main Cover Sealing Type

Terminal covers are wire & crimp Main cover clipped in place and sealed with tamper proof sealing tape

Integrity of meter

Inaccessible without breaking seals

Intended Location of the Meter

Indoor

Type of Register

LCD

Terminal Arrangement(s)

DIN

MID-B-06E Rev 8 EC Type Examination Cert. Page 2 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2

2.

Dated: 20th May 2016

Photographs of Meter and Sealing Plan DSZ12D

Main cover sealing points

MID-B-06E Rev 8 EC Type Examination Cert. Page 3 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2

Dated: 20th May 2016

Terminal cover sealing points

MID-B-06E Rev 8 EC Type Examination Cert. Page 4 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2

Dated: 20th May 2016

DSZ12E

Main cover sealing points

MID-B-06E Rev 8 EC Type Examination Cert. Page 5 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2

Dated: 20th May 2016

Terminal cover sealing points

MID-B-06E Rev 8 EC Type Examination Cert. Page 6 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2

Dated: 20th May 2016

DSZ12A

Main cover sealing points

MID-B-06E Rev 8 EC Type Examination Cert. Page 7 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2

Dated: 20th May 2016

Terminal cover sealing points

MID-B-06E Rev 8 EC Type Examination Cert. Page 8 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2 3.

Dated: 20th May 2016

Nameplates DSZ12E

MID-B-06E Rev 8 EC Type Examination Cert. Page 9 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2

Dated: 20th May 2016

DSZ12D

MID-B-06E Rev 8 EC Type Examination Cert. Page 10 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2

Dated: 20th May 2016

DSZ12A

MID-B-06E Rev 8 EC Type Examination Cert. Page 11 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Dated: 20th May 2016

Issue Number: 2 4.

Calculation of the composite error/ MPE

Current Imin Itr 10Itr Imax Itr 10Itr Imax Itr 10Itr Imax

Influence Factors for temperature, frequency and voltage PF Cos -25°C -10°C 5°C 30°C 40°C 1.0 0.30 0.29 0.32 0.37 0.64 1.0 0.42 0.61 0.69 0.26 0.28 1.0 0.35 0.22 0.24 0.21 0.61 1.0 0.16 0.14 0.15 0.15 0.16 0.5ind 0.32 0.48 0.59 0.63 0.65 0.5ind 0.43 0.49 0.51 0.57 0.57 0.5ind 0.95 0.99 0.69 0.74 0.68 0.8cap 0.38 0.41 0.30 0.30 0.68 0.8cap 0.57 0.59 0.43 0.54 0.41 0.8cap 0.65 0.56 0.72 0.75 0.52

55°C 0.45 0.33 0.54 0.22 0.71 0.48 0.94 0.37 0.42 0.64

L1 Itr 10Itr Imax Itr 10Itr Imax

1.0 1.0 1.0 0.5ind 0.5ind 0.5ind

0.42 0.62 0.58 0.52 0.51 0.57

0.38 0.65 0.73 0.37 0.62 1.06

0.30 0.66 0.72 0.26 0.53 1.06

0.18 0.46 0.63 0.09 0.39 0.86

0.14 0.52 0.68 0.06 0.38 0.98

0.07 0.31 0.54 0.15 0.11 0.81

L2 Itr 10Itr Imax Itr 10Itr Imax

1.0 1.0 1.0 0.5ind 0.5ind 0.5ind

0.27 0.21 0.27 030 0.27 0.21

0.22 0.16 0.24 0.24 0.20 0.18

0.15 0.09 0.19 0.14 0.12 0.15

0.04 0.07 0.14 0.02 0.02 0.09

0.03 0.09 0.12 0.07 0.05 0.08

0.09 0.12 0.09 0.17 0.15 0.10

L3 Itr 10Itr Imax Itr 10Itr Imax

1.0 1.0 1.0 0.5ind 0.5ind 0.5ind

0.21 0.20 0.28 0.28 0.25 0.20

0.16 0.16 0.26 0.18 0.20 0.27

0.09 0.12 0.24 0.12 0.13 0.16

0.03 0.06 0.20 0.02 0.02 0.03

0.07 0.08 0.19 0.07 0.05 0.11

0.12 0.12 0.18 0.16 0.12 0.14

MID-B-06E Rev 8 EC Type Examination Cert. Page 12 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2

Dated: 20th May 2016

During the type approval examination the influence factors for temperature, frequency and voltage are determined per load point. The table above represents the sum of the square values per load, determined via the following formula:e (T, U, f) = √ ( e2 (T, I ,cos) ,  e2 (U, I ,cos) ,  e2 ( f , I ,cos)) where e(T, I ,cos) = e(U, I ,cos) = e( f , I ,cos) =

Additional error due to variation of the temperature at the same load Additional error due to variation of the voltage at the same load Additional error due to variation of the frequency at the same load

MID-B-06E Rev 8 EC Type Examination Cert. Page 13 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2 5.

Dated: 20th May 2016

Annex of Variants

Product Variant Identification Details: Type Designation

Description of meter

DSZ12E

3 x 230/400V 0.25-5(80)A 800 imp/kWh

DSZ12D

3 x 230/400V 0.5-10(80)A LED tariff - 100 imp/kWh S0-output – 1000imp/kWh

DSZ12A

3 x 230/400V 0.5-10(80)A LED tariff - 100 imp/kWh S0-output – 1000imp/kWh

Modifications to the meter(s) described according to approval No.0120/ SGS0204 must be notified to the issuing body to confirm the meter(s) continuing compliance to the relevant pattern approval standard(s).

MID-B-06E Rev 8 EC Type Examination Cert. Page 14 of 15

EC-Type Examination Certificate Number:

0120/ SGS0204 Issue Number: 2 6.

Dated: 20th May 2016

Document Revision History

Issue 1 2

Date

Comments

29/04/2016 20/05/2016

Initial Issue Model DSZ12A added to approval

MID-B-06E Rev 8 EC Type Examination Cert. Page 15 of 15