Applications Evaporator sensor for air conditioning systems Heating systems Features Copper case Twin cable (black) PVC-insulated wires with tinned ends, Tmax = 105 °C Options Alternative resistance ratings, rated temperatures, resistance tolerances, wire lengths and AWG 22, AWG 24 or AWG 26 available on request Delivery mode Bulk Dimensional Drawings
Dimensions in mm Dimensions in mm
Please read Important notes and Cautions and warnings at the end of this document.
Page 2 of 9
Temperature measurement
B57500 / B57501
Probe assemblies
K500 / K501
General technical data Climatic category Max. power Resistance tolerance Rated temperature Dissipation factor Thermal cooling time constant Thermal time constant Heat capacity Insulation resistance Test voltage
(IEC 60068-1) (at 25 °C)
(in air) (in air) (in water) (V = 100 VDC) (t = 1 s)
Please read Important notes and Cautions and warnings at the end of this document.
8016 8016
Page 3 of 9
3988 ±0.5% 3988 ±0.5%
B57500K0103A001 B57501K0682A002
Temperature measurement
B57500 / B57501
Probe assemblies
K500 / K501
Reliability data Test
Standard
Storage in dry heat
IEC 60068-2-2
Test conditions
Storage at upper category temperature T: 100 °C t: 1000 h Storage in damp IEC Temperature of air: 40 °C heat, steady state 60068-2-78 Relative humidity of air: 93% Duration: 56 days Storage in coldness Storage at lower category temperature T: 30 °C t: 1000 h Rapid temperature IEC Lower test temperature: 0 °C cycling (in fluid) 60068-2-14 Upper test temperature: 100 °C Time to change from lower to upper temperature: