1 Pressure regulators ► E/P pressure regulators
E/P pressure regulator, Series ED12
► Flow= 2.6 Cv ► Electr. connection: Plug, M12, 5-pin ► Signal connection: input and output, Socket, M12, 5-pin
00124123
Version
Poppet valve
Control
Analog
Certificates
CE declaration of conformity
Ambient temperature min./max.
+41°F / +122°F
Medium temperature min./max.
+41°F / +122°F
Medium
Compressed air
Max. oil content of compressed air
1 mg/m³
Qn
2.6 Cv
Mounting orientation
α = 0 - 90° ±β = 0 - 90°
Operating pressure
174
Hysteresis
< 0.44 psi
DC operating voltage
24 V
Voltage tolerance DC
-20% / +30%
Permissible ripple
5%
Max. power consumption
1.4
Protection class
IP65
Weight
5.07 lbs
Materials: Housing
Aluminum; Steel
Seal
Hydrogenated acrylonitrile butadiene rubber
Nominal flow Qn with working pressure 101.5 psi, with secondary pressure 87 psi and Δp = 2.9 psi
Technical Remarks
■ The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! ■ The pressure dew point must be at least 27 °F under ambient and medium temperature and may not exceed 37 °F. ■ The oil content of compressed air must remain constant during the life cycle. ■ Use only the approved oils from AVENTICS, see chapter „Technical information“. ■ With oil-free, dry air, other installation positions are possible on request. ■ The protection class is only ensured when the plug is mounted properly. For detailed information, see operating instructions.
Pressure setting range min./max. psi [psi]
Nominal input value
Actual output value
Fig.
Note
Part No.
0 / 145
0 - 20
mA
0 - 20
mA
Fig. 1
-
R414000728
0 / 145
4 - 20
mA
4 - 20
mA
Fig. 1
-
R414000729
0 / 145
0 - 10
V
0 - 10
V
Fig. 2
-
R414000731
0 / 145
0 - 10
V
-
-
Fig. 3
1)
R414000730
1) Output 10V constant to supply a potentiometer Minimum working pressure = 7.25 psi + max. required secondary pressure Additional pressure setting ranges available on request
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2016-09-23, ©AVENTICS S.à r.l., subject to change
2 Pressure regulators ► E/P pressure regulators
E/P pressure regulator, Series ED12
► Flow= 2.6 Cv ► Electr. connection: Plug, M12, 5-pin ► Signal connection: input and output, Socket, M12, 5-pin
Flow diagram
[bar] 10
Pv = 11 bar
9
Pv = 10 bar
8
Pv = 9 bar
7
Pv = 8 bar
6
Pv = 7 bar
5
Pv = 6 bar
4
Pv = 5 bar
3
Pv = 4 bar
2
Pv = 3 bar
1
Pv = 2 bar
0 0
1000
2000
3000
4000
5000
6000
7000
8000 [l/min] 00131778
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2016-09-23, ©AVENTICS S.à r.l., subject to change
3 Pressure regulators ► E/P pressure regulators
E/P pressure regulator, Series ED12
► Flow= 2.6 Cv ► Electr. connection: Plug, M12, 5-pin ► Signal connection: input and output, Socket, M12, 5-pin
Dimensions 254 55,6 31
1)
4
43 4)
62
55
15
50
19
26,8
45,8
51,4
3)
24,6
2)
81 86,6 100
13
123,8
6)
89,5
5)
M6 X2M
SW5 Ma=8Nm
16
X1S
4
ED
24,5
35,5 00124915
1) Operating pressure 2) Working pressure 3) Exhaust 4) Seal (not assembled) 5) + 6) Accessories not supplied
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2016-09-23, ©AVENTICS S.à r.l., subject to change
4 Pressure regulators ► E/P pressure regulators
E/P pressure regulator, Series ED12
► Flow= 2.6 Cv ► Electr. connection: Plug, M12, 5-pin ► Signal connection: input and output, Socket, M12, 5-pin
Mounting orientation
β = ±0...90° β
β
α α = +0...90° 00131782
Functional diagram
00125530
a) Nominal input value b) Actual output value c) Switch output (acknowledge signal) The E/P pressure control valve modulates the pressure corresponding to an analog electrical nominal input value. 1) Operating pressure 2) Working pressure 3) Exhaust
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2016-09-23, ©AVENTICS S.à r.l., subject to change
5 Pressure regulators ► E/P pressure regulators
E/P pressure regulator, Series ED12
► Flow= 2.6 Cv ► Electr. connection: Plug, M12, 5-pin ► Signal connection: input and output, Socket, M12, 5-pin
Fig. 1, Characteristic and pin assignment for current control with actual output value
4) M 2,5 A 1)
+ 24 V DC
1
[bar]
2
0V
10
3 4 5
7,5 5
2)
{
2,5 3) 0
A)
4
0
8
12 16
20
24 V DC
1
0/4 ... 20 mA 0V 0/4 ... 20 mA
2 3 4 5
[mA]
B)
[mA] 4
8
16
12
20 00125475
1) Supply Voltage 2) Switch output (pin 1) and nominal value (pin 2) are related to 0 V. Input current nominal value (ohmic load 100 Ω). 3) Actual value (pin 4) is related to 0 V (max. total resistance of downstream devices < 300 Ω). 4) The operating voltage must be protected by an external M 2.5 A fuse. Connect plug X2M via a shielded cable to ensure EMC. A) Plug X1S B) Plug X2M
Fig. 2, Characteristic and pin assignment for voltage control with actual output value
4) M 2,5 A 1)
+ 24 V DC
[bar] 6 5 4 3 2 1 0
1 2
0V
20
10
15
7,5
10
5 2,5
0
0
3) 0
A)
5
2)
5
3 4
2
4
6
8
10
{
24 V DC
1
0 - 10 V DC 0V 0 - 10 V DC
2 3 4 5
[V]
B)
00125531
1) Supply Voltage 2) Switch output (pin 1) and nominal value (pin 2) are related to 0 V (min load resistance 1 kΩ) 3) Actual value (pin 4) is related to 0 V (min. load resistance 1 kΩ). 4) The operating voltage must be protected by an external M 2.5 A fuse. Connect plug X2M via a shielded cable to ensure EMC. A) Plug X1S B) Plug X2M
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2016-09-23, ©AVENTICS S.à r.l., subject to change
6 Pressure regulators ► E/P pressure regulators
E/P pressure regulator, Series ED12
► Flow= 2.6 Cv ► Electr. connection: Plug, M12, 5-pin ► Signal connection: input and output, Socket, M12, 5-pin
Fig. 3, Characteristic and pin assignment for potentiometer control without actual output value
00125476
1) Supply Voltage 2) Switch output (pin 1) and nominal value (pin 2) are related to 0 V. 3) Potentiometer control (min. 0-2 kΩ, max. 0-10 kΩ) 4) The operating voltage must be protected by an external M 2.5 A fuse. Connect plug X2M via a shielded cable to ensure EMC. A) Plug X1S B) Plug X2M
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2016-09-23, ©AVENTICS S.à r.l., subject to change