PFA

Report 8 Downloads 171 Views
Drawing Key 1880

Pool Fittings (PF) PFA 2x 6" ABS Main Drains PFB Auto Top Up Unit PFC 3x 2" Return Inlets PFD 2 x Wide Angled Skimmers PFE 3x 50W 12v Halogen Lights PFF 3x Deck Boxes PFG 2 x Stainless Steel Ladders PFH 2'' Vac Point

1880 1880

E

D

No Under Floor Heating Pipes Etc In Hatched Area

1500

C

C

Plant Room (PR) UV Sanitisation System TES 10 PRA PRB Variheat 600 Air Handling Unit PRC Electrical Distribution Board PRD 1 HP Pump PRE 24'' Filter PRF Telephone Point PRG Chemical Eye Wash Station PRH Main Pipework Manifold PRI Tap and Gully PRJ Central Tapped Floor Gully PRK 6" Backwash Gully for Filter PRL Erosion Feeder PRM Pool Light transformer PRN Service Socket

600

PFA

PFA

740

1300 1200

PFG

1333

600

1333 760

963

1925

963

2000 491

PFF

B

PFC

PFE

Roldeck motor pit with tiled access cover Drain or sump in base of motor pit (By Others)

B

491

600x600mm access hatch

PFD

A

A 1200 2667

2667

1500 491

PFF

PFE

4000

PFC

8000

1393

3850

1394

Submersible Pump

2667

2667

Backwash Holding Tank 1.6M³

PFH

PFD

(900)

Pool Drains - as per drawing

TBC

491

PFF

PFC

PFE

(901) Skimmers: - Water line is centre of skimmer face

2000 1925

R800

R500

1333

1333 R1100 R1400

(902) Lights: - Centre line 650mm below water level

PFB 256 288

PFB

(903) Deck boxes for u/water lights in pool surround with armoured cable in screed back to plant room. DO NOT CUT CABLE. Place additional cable in u/water niche to allow for bulb changing on pool surround.

1800

F

125

E

D

F

PRE

PRH 90" elbow

900 x 2,100 ND

2276

900 x 2,100 ND

419

PRK PRA

PRD PRB

BROMINE EROSION FEEDER

PRJ

PRL

600

1300

ND 900 x 2,100

a)Pool hall light switch location

PRG

PRI

FFL 122.98

PRM PRC PRF PRN Pool Control Panel

Phone

902 x 2,013 ND

T r a n s f o rm er 1

1200 600

850

c)Stainless steel tile trays for skimmers and deck boxes d) Are grab rails required

Drawing Rev Description of Changes By Set

(904) Inlets: - Centre lines 650mm below water level

T r a n s f o rm er 1

600x600mm access hatch

900 x 2,100 ND

b)Roldeck key switch location

(905) Auto Top up: - Centre line 650mm below water level (906) level

Vac Point: - 350mm below water

(907)

Ladders

Project Name:-

Strathgarry Estate

Drawing Title:-

Pool Fittings

Initially Drawn By:-

Drawing Conception Date:-

General Scale:-

Construction Status:-

Thomas Hamilton

Pool Plan

1:30

Drawing No:-

14/07/10

Provisional

Revision No:-

2159 01 00

THE COPYRIGHT OF THIS DRAWING SUBSISTS IN THE LANARK POOL COMPANY

Drawing Key

Pool Fittings (PF) PFA 2x 6" ABS Main Drains PFB Auto Top Up Unit PFC 3x 2" Return Inlets PFD 2 x Wide Angled Skimmers PFE 3x 50W 12v Halogen Lights PFF 3x Deck Boxes PFG 2 x Stainless Steel Ladders PFH 2'' Vac Point Plant Room (PR) UV Sanitisation System TES 10 PRA PRB Variheat 600 Air Handling Unit PRC Electrical Distribution Board PRD 1 HP Pump PRE 24'' Filter PRF Telephone Point PRG Chemical Eye Wash Station PRH Main Pipework Manifold PRI Tap and Gully PRJ Central Tapped Floor Gully PRK 6" Backwash Gully for Filter PRL Erosion Feeder PRM Pool Light transformer PRN Service Socket 2172

1705

1394

1394

100

1394 175 Freeboard

PFD

1394

PFG

Piped back to plant room

850

650

175 Freeboard

PFD

3850 1350

1350

PFC

1175

256

32mm Finishes

Piped back to plant room

32mm Finishes 57mm Finishes

650 3850

256

PFC

Motor pit

288

1175

PFB

1350

1925

1925

200

Piped back to plant room

Cover pit in the base of pool 250

Section B-B

Section A-A 1 2''

1 2''

Mains water supply

PFG

Mains water supply

PFF

PFF

PFF

175 Freeboard

175 Freeboard 350

650 1333

PFC

650 2667

650 1333

PFB

1175

PFC

Overflow pipe piped back to drain location TBC

650

2667

PFC

PFC

8000

650

PFE

PFB

650

PFD

PFE

650

PFD

1350

PFE

650

1175

32mm Finishes 57mm Finishes 8000

650 250

250

650

650

650

Section D-D

Piped back to plant room

Section E-E

Piped back to plant room

Drawing Rev Description of Changes By Set

Roldeck motor pit with tiled access cover

1394

1394

175

Motor pit exhaust piped to external building. Terminating the pipe to a suitable vent location TBC

650 3850

1175

PFB

1350

1688

Project Name:-

Access Ladders

100

963

1925

963

750

Strathgarry Estate

Drawing Title:-

Roldeck motor

650

Sump or drain in base of motor pit TBC

PFA

PFA

Pool Sections

Initially Drawn By:-

Drawing Conception Date:-

General Scale:-

Construction Status:-

Thomas Hamilton

250

91

Section C-C

1:30

Drawing No:-

14/07/10

Provisional

Revision No:-

2159 02 00

THE COPYRIGHT OF THIS DRAWING SUBSISTS IN THE LANARK POOL COMPANY

Drawing Key

No Under Floor Heating Pipes Etc In Hatched Area

1500

2 INCH PIPE

2 INCH PIPE

2 INCH PIPE

PFA PFG

PFA

4 INCH CONDUIT

1333 760 1925

Returns 2'' Delivery pipe

conduit from roldeck motor pit to plant room 4 '' exhaust pipe from roldeck motor pit to external building

491

4000

PFC

8000

3850

1394

2 INCH PIPE

2667

4 INCH CONDUIT

2667

PFH

491

4 INCH CONDUIT

PFC

PFE 2000

2 INCH PIPE

1925

R800

R500

1333

2 INCH PIPE

PFF

2'' Vac pipe piped back to plant room

2 INCH PIPE

PFD

2 INCH PIPE

2 INCH PIPE

2 INCH PIPE

1393

2 INCH PIPE

PFE

Automatic Topup Unit 1 2'' Alkathine pipe 1.5 overflow Pipe

4 INCH CONDUIT

491

PFF

Plant Room (PR) UV Sanitisation System TES 10 PRA PRB Variheat 600 Air Handling Unit PRC Electrical Distribution Board PRD 1 HP Pump PRE 24'' Filter PRF Telephone Point PRG Chemical Eye Wash Station PRH Main Pipework Manifold PRI Tap and Gully PRJ Central Tapped Floor Gully PRK 6" Backwash Gully for Filter PRL Erosion Feeder PRM Pool Light transformer PRN Service Socket

2 INCH PIPE

2667

2 INCH PIPE

2667

2 INCH PIPE

Turnover 4 Hours

4'' Exhaust Pipe from motor pit to external Others 4 '' Cable building 4 INCH CONDUIT

2 INCH PIPE

PFC

PFE

PFD

2 INCH PIPE

2x Main Drain 2'' suction pipe

Turnover Rate 9.12M³/hr

491

1333 R1100

Drawing Rev Description of Changes By Set

PFB

2 INCH PIPE 2 INCH PIPE

2 INCH PIPE

R1400

2 INCH PIPE

256 288

2 INCH PIPE

2 INCH PIPE

PFB

4'' Cable conduit from motor pit to plant room for all wiring

1800

2 INCH PIPE Project Name:-

2 INCH PIPE 2 INCH PIPE 2 INCH PIPE

2 INCH PIPE 2 INCH PIPE

PRH 90" elbow

900 x 2,100 ND

x 2,100 ND

2276

PRK

PRE

125

2 INCH PIPE

Pool Capacity 36.48M³

963

2000

PFF

2x Skimmers 2'' suction pipe

740

1333

963

Pool Size 8 x 3.8 x1.2 M Deep

Pool Fittings (PF) PFA 2x 6" ABS Main Drains PFB Auto Top Up Unit PFC 3x 2" Return Inlets PFD 2 x Wide Angled Skimmers PFE 3x 50W 12v Halogen Lights PFF 3x Deck Boxes PFG 2 x Stainless Steel Ladders PFH 2'' Vac Point

419

Strathgarry Estate

Drawing Title:-

Pipework Layout

Initially Drawn By:-

Drawing Conception Date:-

General Scale:-

Construction Status:-

Thomas Hamilton 1:20

Drawing No:-

14/07/10

Provisional

Revision No:-

2159 03 00

THE COPYRIGHT OF THIS DRAWING SUBSISTS IN THE LANARK POOL COMPANY

Drawing Key Da GLA

Wd

SS

We

940

470

GLA

SS

650

486

908

486

650

940

1880

470

1880 1880

300

Spigot

250

Window sill Finished Floor Level

Finishes Floor

300

No Under Floor Heating Pipes Etc In Hatched Area

1500

leg took off ductting to deliver hot air to roldeck motor pit

Spigot

POOL Water Line

External wall

Internal wall

PFA PFG

470

PFA

Typical Grill Detail at Floor Spiral Duct Typical Grill Detail at Sill Spigot in Wall Cavity Spiral Duct

760 1925

963

Roldeck motor pit with tiled access cover Drain or sump in base of motor pit (By Others)

2000 491

PFF

940

PFC

PFE

2807

Grille can be located centrally on the sill. We recommend that the grill not be less than 20mm form the glazing

2807

PFD

Wf

940

940

Dampers 228

2667

2667

Window sill 470

Plant Room (PR) UV Sanitisation System TES 10 PRA PRB Variheat 600 Air Handling Unit PRC Electrical Distribution Board PRD 1 HP Pump PRE 24'' Filter PRF Telephone Point PRG Chemical Eye Wash Station PRH Main Pipework Manifold PRI Tap and Gully PRJ Central Tapped Floor Gully PRK 6" Backwash Gully for Filter PRL Erosion Feeder PRM Pool Light transformer PRN Service Socket

Ducting Notes

940

491

Wc

Duct

470

1333

963

Insulation

Duct

740

1333

Pool Fittings (PF) PFA 2x 6" ABS Main Drains PFB Auto Top Up Unit PFC 3x 2" Return Inlets PFD 2 x Wide Angled Skimmers PFE 3x 50W 12v Halogen Lights PFF 3x Deck Boxes PFG 2 x Stainless Steel Ladders PFH 2'' Vac Point

Grill 75x 500 with 32 flange Spigot Internal wall

1265

470

Please note section on left. The outer wall of the building will have to be designed so that it can incorporate the spigot within the internal wall structure without affecting any structural elements. The details of the wall make will be confirmed by the architect.

250

100

External wall

220

470

470

Duct

491

PFF

PFE

4000

PFC

8000

1393

3850

1394

940

940

Duct Insulation

Wb

2820

2820

Section Through Detail at Window Sill

WG 940 2667

2667

PFH

940

PFD

470

Grill With 32mm Overhang

470

350

m m 0 50

220

491

180

400

PFC

PFE

470

Leg off duct work to deliver hot air to motor pit

2000 1925

R800

R500

940

1333

1333

To Be Confirmed

PFF

470

940

R1100 R1400

Wa

PFB

2820

WH

2820

256 288

940

940

PFB

500

1800 400

470

470

75 Stiffeners To Be Fitted To Prevent Duct Collapsing Spigot

boiler Exhaust Fresh Air

Ø125-150 Duct Form Main Duct Branch

Filter

Air Unit

Return Air(Moist)

Typical Spigot Detail

125

400

PRE

PRH 90" elbow

900 x 2,100 ND

900 x 2,100 ND

2276

1000x1000 mm pool hall extract grill

419

Notes:

PRK PRA

250x250 mm external fresh air grill

PRD PRB

BROMINE EROSION FEEDER

PRJ

PRL

600

1300

ND 900 x 2,100

PRG

Ducting Notes

Drawing Rev Description of Changes By Set

PRI

FFL 122.98

PRM PRC PRF PRN Pool Control Panel

Phone

T r a n s f o rm er 1

1200 600

6) 7)

T r a n s f o rm er 1

902 x 2,013 ND

1) 2) 3) 4) 5)

All ducting to be at high and low level. . Duct spigot and reducer sizes all as shown on dwg 2159-04. All ducting is spiral Galvanised - sizes shown do not include 25mm all round insulation Provision of openings through block work for duct runs, grilles and spigots to be provided by others. Individual grilles in floor/sill to be located as close as possible to glazed sections - grill detail to be confirmed by Architect All grilles are Satin Anodised Aluminium Finished with 32mm all around flange but any Ral colours is available on request -extra over cost to be confirmed on request (grilles to be confirmed by Architect) Ducting layout is representational only of route to be taken Hot air will be delivered to the motor pit and exhausted to externalOf building .

600x600mm access hatch

250x250 mm external exhaust grill

Project Name:-

Variheat Series III

Strathgarry Estate

Drawing Title:-

Pool Hall Air Intake Grill 1000mm x 1000mm In Standard Anodised Aluminium (Colour to Match Interior available as extra) Fresh air and exhaust air openings 250mm x 250mm

Ventilation Layout

Initially Drawn By:-

Drawing Conception Date:-

General Scale:-

Construction Status:-

Thomas Hamilton 1:30

Drawing No:-

14/07/10

Provisional

Revision No:-

2159 04 00

THE COPYRIGHT OF THIS DRAWING SUBSISTS IN THE LANARK POOL COMPANY

B

Drawing Key

Mechanical Specification 1800

Note:Calorex Variheat 600

No allowances for chemical storage has been made within the plant room

125

2276

90" elbow

(M702)

PRK PRA

PRE

PRH

(M700) LPHW flow and return pipe work and connection incorporating motorised divertor valve with actuator to bypass between the Central Boiler plant and the 1 no. Calorex Variheat unit in the pool plant room. The pipe diameter and boiler circulation pump rating should be sized to provide primary water at the temperature and flow rate stipulated. Primary connection is 1” BSP male. Flow rate of 25-litres/min to overcome pressure drop of 6.3m head Flow temperature 82 degrees centigrade - return temperature 71 degree centigrade (a temperature stat should be fitted by mechanical services engineer to verify this)

Cold Water Feed to Pool Pump Manifold 419

Plant Room (PR) UV Sanitisation System TES 10 PRA PRB Variheat 600 Air Handling Unit PRC Electrical Distribution Board PRD 1 HP Pump PRE 24'' Filter PRF Telephone Point PRG Chemical Eye Wash Station PRH Main Pipework Manifold PRI Tap and Gully PRJ Central Tapped Floor Gully PRK 6" Backwash Gully for Filter PRL Erosion Feeder PRM Pool Light transformer PRN Service Socket

(M701) *A valved 22mm cold water supply including connection to the ¾” BSP female connection on pool pipework suction manifold in the plant room (this supply to have double check valve)

(M701)

Cold Water Top up to Freeboard Pool

PRD

(M702) *A valved 15mm cold water supply including connection to the ½” BSP male connection on the spa side automatic top unit. (via break tank) Damage can be caused by over tightening this connection.

(M700)

PRB

BROMINE EROSION FEEDER

PRJ

PRL

PRG

Pool Fittings (PF) PFA 2x 6" ABS Main Drains PFB Auto Top Up Unit PFC 3x 2" Return Inlets PFD 2 x Wide Angled Skimmers PFE 3x 50W 12v Halogen Lights PFF 3x Deck Boxes PFG 2 x Stainless Steel Ladders PFH 2'' Vac Point

PRI

FFL 122.98

(M703)

(M703) A 15mm branch terminating in a tap with hose connection in pool plant room.

PRM PRC PRF PRN Pool Control Panel

Phone

Tra nsformer 1

Tra nsformer 1

Note: - Dependant upon local by-laws, items marked with * may have to be via a header tank or alternatively via a double non-return valve. Electrical Specification (1)

35 amp single phase or 20 three-phase supply brought to and terminated adjacent to our distribution board in pool plant room.

902 x 2,013 ND

Drawing Rev Description of Changes By Set

Project Name:-

Strathgarry Estate

Drawing Title:-

Plant Room Layout Mechanical

Initially Drawn By:-

Drawing Conception Date:-

General Scale:-

Construction Status:-

Thomas Hamilton 1:10

Drawing No:-

14/07/10

Provisional

Revision No:-

2159 05 00

THE COPYRIGHT OF THIS DRAWING SUBSISTS IN THE LANARK POOL COMPANY

Drawing Key

H

500x500 mm opening for through plant room floor. (Pool main duct to glazing)

General Attendances ( I ) Temporary power, lighting, toilet facilities, taking delivery of, off-loading and placing of materials and equipment and storing in secure weatherproof storage.

Plant room equipment removed for clarity 90" elbow

419

1000x1000 mm pool hall extract grill

ATTENDANCES REQUIRED BY OTHERS

( II ) LPHW, electricity, heating of pool hall and water for testing and commissioning prior to handover of the installation.

1016

( III ) Vapour barrier and roof details by others.

1000

500x500 mm opening for through plant room floor. (Pool main duct to glazing)

500 2067

PRJ

400

Builders Work - General Pool Tank Excavations/Construction: - As per engineer's drawings

Builders Work - Drainage 309

(100) Sub-surface drainage under tank by others. 530

(101) Drainage point adjacent to poolside auto top up for our connection to overflow pipe.

Pool Fittings (PF) PFA 2x 6" ABS Main Drains PFB Auto Top Up Unit PFC 3x 2" Return Inlets PFD 2 x Wide Angled Skimmers PFE 3x 50W 12v Halogen Lights PFF 3x Deck Boxes PFG 2 x Stainless Steel Ladders PFH 2'' Vac Point Plant Room (PR) UV Sanitisation System TES 10 PRA PRB Variheat 600 Air Handling Unit PRC Electrical Distribution Board PRD 1 HP Pump PRE 24'' Filter PRF Telephone Point PRG Chemical Eye Wash Station PRH Main Pipework Manifold PRI Tap and Gully PRJ Central Tapped Floor Gully PRK 6" Backwash Gully for Filter PRL Erosion Feeder PRM Pool Light transformer PRN Service Socket

Builders Work - Pool Hall

500x500 mm opening for pool main duct to glazing

(102) Construction of Pool Tank - Seymour Pools

H

G

Section Through AHU

Plant Room Plan

G

(103) Building in of pool tank fittings - lights, drains, auto top unit, vacuum point, skimmers, inlets etc and fitting of coping - Seymour Pools (104) Care Must be taken when placing pool surround backfill to ensure pool pipes are not damaged. Careful backfilling (if specified) of pool surround with pea gravel by others after tank and pipes have been tested - Main Contractor (105) Openings in blockwork/floor for Variheat unit as detailed on drawing 2159- 04 (106) Accommodation for insulated galvanised spiral ducting as detailed on drawing 2159 - 04 (107) Accommodation for spigots through floor slab at glazing sizes and number as drawing 2159- 04. Grill detail to be confirmed by Client/Architect.

1000x1000 mm opening for pool hall extract grill

(108) Route for pool water circulation pipes in temporary trench 650 x 450mm below F.F.L. from pool surround void to plant room as detailed on drawing 2159- 03. (109) Cable routes for: - pool light deck boxes to transformers under distribution board in plant room, Roldeck cover motor and switch and pool hall light switching. (110) 1 No. Lightweight Manhole cover and frame over pool cover motor pit with ladder access. (111) Route and installation of 50mm O.D. overflow pipe from poolside auto-top-up unit tank to external drain.

1000

(112) Final fixing of pool light "deck boxes” ,auto top up and skimmer lid boxes to be level with floor finishes (Client/Architect to confirm).

1000

(113) Holes through walls and floors for the passage of cables, pipes, overflow and vent pipes to motor cover pit, and making good same - Main Contractor Builders Work - Plant room (200) Natural low and high-level ventilation in plant room. If plant room contains boiler then grille sizes to be determined by boiler installer.

677

563

1713

(201) Ventilation required in plant room either by mechanical means or louvered door or similar - Main Contractor. (202) Trapped floor gully adjacent to filter to accept backwash (usually 4” or 6” diameter pipe with slow “S” bend to soak away). Outflow to be taken to soakaway, not a foul water sewer or septic tank and is to take the weekly backwash discharge and the full emptying of the pool, should that ever be required - Main Contractor

500

500

(203) Central trapped floor gully in pool plant room with floor laid to falls to waste to accept spillage - Main Contractor

500x500 mm opening for pool main duct to glazing

500

500x500 mm opening for all pool pipe work from pool to plant room

(204) Trapped floor gully with standpipe for hose with hose connection - Main Contractor (205) Service socket for future maintenance - Seymour

Section F-F Through Pool Hall

(206) Note: There is no space allocated for chemical storage. (207) ¾” Condensate from Variheat unit piped into adjacent drain in plant room- Seymour Pools

Builders Work - Pool Cover

Drawing Rev Description of Changes By Set

(600) Installation of sleeve and socket for pool cover roller. If core drilling, the shaft & sleeve require a hole of 52mm. Alternatively you can build a piece of 2” class C pipe through the wall which is also the perfect size for the sleeve. Position of shaft to be confirmed.

250x250mm opening for external fresh air grill

(602) Pit formed for pool cover motor with base laid to fall to drain with drain to waste. Natural ventilation to pit must also be incorporated.

Plant room door

(603) Central trapped floor gully in cover pit.

250x250 mm opening for external exhaust grill

(604) Drainage connection onto outlet in base of cover pit. (605) Automatic pool controller in plant room via switch - position to be confirmed (switch to be recessed and cable raggled into wall) and cover motor in pit.

Project Name:-

Strathgarry Estate

Drawing Title:-

Builders Work

Initially Drawn By:-

Drawing Conception Date:-

General Scale:-

Construction Status:-

Thomas Hamilton 1:20

Elevation H-H On Plant Room Wall

Elevation G-G On Plant Room Wall

Drawing No:-

14/07/10

Provisional

Revision No:-

2159 09 00

THE COPYRIGHT OF THIS DRAWING SUBSISTS IN THE LANARK POOL COMPANY

Drawing Key

Pool Fittings (PF) PFA 2x 6" ABS Main Drains PFB Auto Top Up Unit PFC 3x 2" Return Inlets PFD 2 x Wide Angled Skimmers PFE 3x 50W 12v Halogen Lights PFF 3x Deck Boxes PFG 2 x Stainless Steel Ladders PFH 2'' Vac Point Plant Room (PR) UV Sanitisation System TES 10 PRA PRB Variheat 600 Air Handling Unit PRC Electrical Distribution Board PRD 1 HP Pump PRE 24'' Filter PRF Telephone Point PRG Chemical Eye Wash Station PRH Main Pipework Manifold PRI Tap and Gully PRJ Central Tapped Floor Gully PRK 6" Backwash Gully for Filter PRL Erosion Feeder PRM Pool Light transformer PRN Service Socket

443

330 294 274

356

Tile

90

167

Ø70

Puddle Flange

25

169

215

Hollow Blocks

188

Ø192 Ø202 Ø256

2" Socket 266

Plan On Halogen Light Detail

Plan On Ladder Detail

232 266

Plan On 2'' Inlet Detail

Plan On Pool Skimmer (Certikin) Detail Finished Detail

175 Freeboard

175 Freeboard

Water Line

Note Do Not Cut Cable

FFL

Render

2 core 4mm steel wire armour (swa) to transformer in plant room inside riged conduit

266

150 Freeboard

5

Ladder 650

Puddle Flange

385

45

Ø70

Ø194

270 Ø330

400

Hollow Blocks

90

Hollow Blocks

171

2" Socket

149

Tile

Tile

25mm Render

Pool Wall Width

25mm Render

Section Through Ladder (Certikin) Finished Detail

Pool Wall Width

Section Through Inlet (Certikin) Finished Detail

Pool Wall Width

Hollow Blocks

25mm Render 50mm Render

Tile 25mm Render

Being Pipework Out Of Pool Slab & Return To Plant Room

Section Through 9" Main Drain Detail Built Into Pool Base

Main Drain Pool Water Return Pipework Cast Into Base & Taken Back To Plant Room

Section Through Pool Skimmer (Certikin) Finished Detail

Note:- when fitting skimmers the lid will be formed out prior to poring the floor to increase the height by an extra 25mm as the freeboard is 175mm

6" Main Drain Faceplate 32 Ø280

5mm Tile Ø220 25mm Render

Ø198 190

Main Drain Pool Water Return Pipework Cast Into Base & Taken Back To Plant Room

50mm Render

51mm Render Pool Wall Width

Hollow Blocks

Tile

Please Note Plan Of Puddle Hollow Blocks

50mm Render Pool Wall Width

Section Through Pool Halogen Light (Certikin) Finished Detail

Inlet Nozzle/Faceplate

Tile

25mm Render

25mm Render 50mm Render

Being Pipework Out Of Pool Slab & Return To Plant Room

Render

218

Hollow Blocks 650

Ø192 Ø202 Ø246 Ø256

Water Line

246.5

FFL

Access Panel

155 212

Access Panel

44

175 Freeboard

Section Through 6" Main Drain Detail Built Into Pool Base

50mm Render

Drawing Rev Description of Changes By Set

Ø148 Ø160

Project Name:-

Strathgarry Estate

Drawing Title:-

Pool Fittins Installation

Initially Drawn By:-

Drawing Conception Date:-

General Scale:-

Construction Status:-

Thomas Hamilton NTS

Drawing No:-

14/07/10

Provisional

Revision No:-

2159 10 00

THE COPYRIGHT OF THIS DRAWING SUBSISTS IN THE LANARK POOL COMPANY