Power Sentry Field Install

Report 0 Downloads 108 Views
Power Sentry Field Install Wiring Diagram & Instructions - One Board

Field Install Instructions * 1. Disconnect Neutral from Driver 2. Connect Neutral to Power Sentry WHITE 3. Connect Power Sentry RED/WHT to Driver Neutral 4. Connect Line to Power Sentry UNSWITCHED BLACK (Line input must be un-switched) 5. Connect Power Sentry RED wire to wire nut with Driver LED (+) (in this example RED) 6. Remove wire from LED Board (-) (in this example BLACK) 7. Connect Power Sentry YEL wire to LED Board (-) 8. Connect Power Sentry BLU wire to wire nut with Driver LED (-) (in this example BLACK) 9. Cap unused BLU/WHT and YEL/BLK wires

* SEE REVERSE FOR MOUNTING OPTIONS AND PLACEMENT See appropriate Power Sentry Installation Instructions for applicable warnings and precautions

Mounting Distance of Battery Backup from Driver and Mounting Heights of Luminaire Fixture Family

Minimum distance of battery pack from driver

2ACL2 2ACL4 ALL4 2ALL2 2ALL4 AVL4 2AVL2 2AVL4 2BZL2 2BZL4 2FSL2 2FSL4 GTL4 2GTL2 2GTL4 RTL4 2RTL2 2RTL4 SBL4 2SBL2 TL4 2TL2 2TL4 VTL4 2VTL2 2VTL4 LBL4 STL2 STL4 WL2 WL4 HTZL1 ZL1 TZL1 BRM9 BRW9L RD4M SPM9L BLT2 2BLT2 2BLT4 BLT4 MSL TMSL ALT

Remote mount only Remote mount only 3 inches Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only 3 inches Remote mount only Remote mount only 6 inches Remote mount only 6 inches Remote mount only 4 inches for less than 6000 lumen; remote mount for 6000 or more lumen 3 inches Remote mount only Remote mount only 6 inches Remote mount only Remote mount only 4 inches for less than 6000 lumens; remote mount for 6000 or more lumens Remote mount only Remote mount only Remote mount only Remote mount only 4 inches 4 inches 4 inches 5 inches 5 inches Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only

Alternative Mounting

Remote mount

Remote mount Remote mount Remote mount Remote mount

Remote mount

Remote mount

Remote mount Remote mount Remote mount Remote mount Remote mount

3.27.2017

Max Mounting Height (ft) 17 19 27 27 27 45 23 23 20 20 17 17 21 21 21 29 20 20 18 17 25 25 27 17 17 17 20 23 20 24 24 18 18 18 14 14 13 19 22 22 21 22 25 25 22

Power Sentry Field Install Wiring Diagram & Instructions - Two Boards in Parallel

Field Install Instructions * 1. Disconnect Neutral from Driver 2. Connect Neutral to Power Sentry WHITE 3. Connect Power Sentry RED/WHT to Driver Neutral 4. Connect Line to Power Sentry UNSWITCHED BLACK (Line input must be un-switched) 5.

Connect Power Sentry RED wire to wire nut with Driver LED (+) (in this example RED) (An additional or larger wire nut may be required)

6. Remove Driver LED (-) wire from wire nut (in this example BLACK) 7. Connect Power Sentry YEL wire to wire nut with LED Boards (-) (An additional or larger wire nut may be required) 8. Connect Power Sentry BLU wire to wire nut with Driver LED (-) (in this example BLACK) 9. Cap unused BLU/WHT and YEL/BLK wires * SEE REVERSE FOR MOUNTING OPTIONS AND PLACEMENT See appropriate Power Sentry Installation Instructions for applicable warnings and precautions

Mounting Distance of Battery Backup from Driver and Mounting Heights of Luminaire Fixture Family

Minimum distance of battery pack from driver

2ACL2 2ACL4 ALL4 2ALL2 2ALL4 AVL4 2AVL2 2AVL4 2BZL2 2BZL4 2FSL2 2FSL4 GTL4 2GTL2 2GTL4 RTL4 2RTL2 2RTL4 SBL4 2SBL2 TL4 2TL2 2TL4 VTL4 2VTL2 2VTL4 LBL4 STL2 STL4 WL2 WL4 HTZL1 ZL1 TZL1 BRM9 BRW9L RD4M SPM9L BLT2 2BLT2 2BLT4 BLT4 MSL TMSL ALT

Remote mount only Remote mount only 3 inches Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only 3 inches Remote mount only Remote mount only 6 inches Remote mount only 6 inches Remote mount only 4 inches for less than 6000 lumen; remote mount for 6000 or more lumen 3 inches Remote mount only Remote mount only 6 inches Remote mount only Remote mount only 4 inches for less than 6000 lumens; remote mount for 6000 or more lumens Remote mount only Remote mount only Remote mount only Remote mount only 4 inches 4 inches 4 inches 5 inches 5 inches Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only

Alternative Mounting

Remote mount

Remote mount Remote mount Remote mount Remote mount

Remote mount

Remote mount

Remote mount Remote mount Remote mount Remote mount Remote mount

3.27.2017

Max Mounting Height (ft) 17 19 27 27 27 45 23 23 20 20 17 17 21 21 21 29 20 20 18 17 25 25 27 17 17 17 20 23 20 24 24 18 18 18 14 14 13 19 22 22 21 22 25 25 22

Power Sentry Field Install Wiring Diagram & Instructions - Four Boards in Parallel

Field Install Instructions * 1. Disconnect Neutral from Driver 2. Connect Neutral to Power Sentry WHITE 3. Connect Power Sentry RED/WHT to Driver Neutral 4. Connect Line to Power Sentry UNSWITCHED BLACK (Line input must be un-switched) 5.

Connect Power Sentry RED wire to wire nut with Driver LED (+) (in this example RED) (An additional or larger wire nut may be required)

6. Remove Driver LED (-) wire from wire nut (in this example BLACK) 7. Connect Power Sentry YEL wire to wire nut with LED Boards (-) (An additional or larger wire nut may be required) 8. Connect Power Sentry BLU wire to wire nut with Driver LED (-) (in this example BLACK) 9. Cap unused BLU/WHT and YEL/BLK wires * SEE REVERSE FOR MOUNTING OPTIONS AND PLACEMENT See appropriate Power Sentry Installation Instructions for applicable warnings and precautions

Mounting Distance of Battery Backup from Driver and Mounting Heights of Luminaire Fixture Family

Minimum distance of battery pack from driver

2ACL2 2ACL4 ALL4 2ALL2 2ALL4 AVL4 2AVL2 2AVL4 2BZL2 2BZL4 2FSL2 2FSL4 GTL4 2GTL2 2GTL4 RTL4 2RTL2 2RTL4 SBL4 2SBL2 TL4 2TL2 2TL4 VTL4 2VTL2 2VTL4 LBL4 STL2 STL4 WL2 WL4 HTZL1 ZL1 TZL1 BRM9 BRW9L RD4M SPM9L BLT2 2BLT2 2BLT4 BLT4 MSL TMSL ALT

Remote mount only Remote mount only 3 inches Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only 3 inches Remote mount only Remote mount only 6 inches Remote mount only 6 inches Remote mount only 4 inches for less than 6000 lumen; remote mount for 6000 or more lumen 3 inches Remote mount only Remote mount only 6 inches Remote mount only Remote mount only 4 inches for less than 6000 lumens; remote mount for 6000 or more lumens Remote mount only Remote mount only Remote mount only Remote mount only 4 inches 4 inches 4 inches 5 inches 5 inches Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only

Alternative Mounting

Remote mount

Remote mount Remote mount Remote mount Remote mount

Remote mount

Remote mount

Remote mount Remote mount Remote mount Remote mount Remote mount

Max Mounting Height (ft) 17 19 27 27 27 45 23 23 20 20 17 17 21 21 21 29 20 20 18 17 25 25 27 17 17 17 20 23 20 24 24 18 18 18 14 14 13 19 22 22 21 22 25 25 22

3.27.2017

Power Sentry Field Install Wiring Diagram & Instructions - Eight Boards in Parallel

Field Install Instructions * 1. Disconnect Neutral from Driver 2. Connect Neutral to Power Sentry WHITE 3. Connect Power Sentry RED/WHT to Driver Neutral 4. Connect Line to Power Sentry UNSWITCHED BLACK (Line input must be un-switched) 5.

Connect Power Sentry RED wire to wire nut with Driver LED (+) (in this example RED) (An additional or larger wire nut may be required)

6. Remove Driver LED (-) wire from wire nut (in this example BLACK) 7. Connect Power Sentry YEL wire to wire nut with LED Boards (-) (An additional or larger wire nut may be required) 8. Connect Power Sentry BLU wire to wire nut with Driver LED (-) (in this example BLACK) 9. Cap unused BLU/WHT and YEL/BLK wires * SEE REVERSE FOR MOUNTING OPTIONS AND PLACEMENT See appropriate Power Sentry Installation Instructions for applicable warnings and precautions

Mounting Distance of Battery Backup from Driver and Mounting Heights of Luminaire Fixture Family

Minimum distance of battery pack from driver

2ACL2 2ACL4 ALL4 2ALL2 2ALL4 AVL4 2AVL2 2AVL4 2BZL2 2BZL4 2FSL2 2FSL4 GTL4 2GTL2 2GTL4 RTL4 2RTL2 2RTL4 SBL4 2SBL2 TL4 2TL2 2TL4 VTL4 2VTL2 2VTL4 LBL4 STL2 STL4 WL2 WL4 HTZL1 ZL1 TZL1 BRM9 BRW9L RD4M SPM9L BLT2 2BLT2 2BLT4 BLT4 MSL TMSL ALT

Remote mount only Remote mount only 3 inches Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only 3 inches Remote mount only Remote mount only 6 inches Remote mount only 6 inches Remote mount only 4 inches for less than 6000 lumen; remote mount for 6000 or more lumen 3 inches Remote mount only Remote mount only 6 inches Remote mount only Remote mount only 4 inches for less than 6000 lumens; remote mount for 6000 or more lumens Remote mount only Remote mount only Remote mount only Remote mount only 4 inches 4 inches 4 inches 5 inches 5 inches Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only

Alternative Mounting

Remote mount

Remote mount Remote mount Remote mount Remote mount

Remote mount

Remote mount

Remote mount Remote mount Remote mount Remote mount Remote mount

Max Mounting Height (ft) 17 19 27 27 27 45 23 23 20 20 17 17 21 21 21 29 20 20 18 17 25 25 27 17 17 17 20 23 20 24 24 18 18 18 14 14 13 19 22 22 21 22 25 25 22 3.27.2017

Power Sentry Field Install Wiring Diagram & Instructions - Two Boards in Series, Two Boards in Parallel

Field Install Instructions * 1. Disconnect Neutral from Driver 2. Connect Neutral to Power Sentry WHITE 3. Connect Power Sentry RED/WHT to Driver Neutral 4. Connect Line to Power Sentry UNSWITCHED BLACK (Line input must be un-switched) 5. Connect Power Sentry RED wire to wire nut with Driver LED (+) (in this example RED) (An additional or larger wire nut may be required) 6. Remove Driver LED (-) wire from wire nut (in this example BLACK) 7. Connect Power Sentry YEL wire to wire nut with LED Boards (-) (An additional or larger wire nut may be required) 8. Connect Power Sentry BLU wire to wire nut with Driver LED (-) (in this example BLACK) 9. Cap unused BLU/WHT and YEL/BLK wires

* SEE REVERSE FOR MOUNTING OPTIONS AND PLACEMENT

See appropriate Power Sentry Installation Instructions for applicable warnings and precautions

Mounting Distance of Battery Backup from Driver and Mounting Heights of Luminaire Fixture Family

Minimum distance of battery pack from driver

2ACL2 2ACL4 ALL4 2ALL2 2ALL4 AVL4 2AVL2 2AVL4 2BZL2 2BZL4 2FSL2 2FSL4 GTL4 2GTL2 2GTL4 RTL4 2RTL2 2RTL4 SBL4 2SBL2 TL4 2TL2 2TL4 VTL4 2VTL2 2VTL4 LBL4 STL2 STL4 WL2 WL4 HTZL1 ZL1 TZL1 BRM9 BRW9L RD4M SPM9L BLT2 2BLT2 2BLT4 BLT4 MSL TMSL ALT

Remote mount only Remote mount only 3 inches Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only 3 inches Remote mount only Remote mount only 6 inches Remote mount only 6 inches Remote mount only 4 inches for less than 6000 lumen; remote mount for 6000 or more lumen 3 inches Remote mount only Remote mount only 6 inches Remote mount only Remote mount only 4 inches for less than 6000 lumens; remote mount for 6000 or more lumens Remote mount only Remote mount only Remote mount only Remote mount only 4 inches 4 inches 4 inches 5 inches 5 inches Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only Remote mount only

Alternative Mounting

Remote mount

Remote mount Remote mount Remote mount Remote mount

Remote mount

Remote mount

Remote mount Remote mount Remote mount Remote mount Remote mount

Max Mounting Height (ft) 17 19 27 27 27 45 23 23 20 20 17 17 21 21 21 29 20 20 18 17 25 25 27 17 17 17 20 23 20 24 24 18 18 18 14 14 13 19 22 22 21 22 25 25 22

3.27.2017