Key Features: • Low profile, lightweight, cool running - due to high efficiency toroidal design • Dual 117/234 VAC primary, 50/60 Hz. operation • 98 standard models from 6VAC to 240VAC output. • 15 standard VA sizes from 15 - 1,500VA • Center single hole mounting • Supplied with two rubber insulating pads, one metal centering washer and all mounting hardware • Center bolt size is 10-24 x 3 inch RHMS zinc plated • Minimum 8" long flexible leads • Due to toroid design - no electrostatic shield required • Hi-Pot test of 4,000V RMS between primary & secondary • CSA certified • UL recognized • CE certified For more information on this series, go to: http://www.hammondmfg.com/182.htm
www.hammondmfg.com
August 2009
Connection Information 182 Series Toroidal Power Transformers Primary Connections - 182 Series Transformers Primary Wiring for 117V (Parallel Connection)
Primary Wiring for 234V (Series Connection)
Blk
Red
Blk
Red
Wht
Blu
Wht
Blu
117 VAC
234 VAC Brn
Gry
Brn
Gry
Orn
Yel
Orn
Yel
PRI
SEC
PRI
SEC
Secondary Connections - 182 Series Transformers Secondary Wiring (Series Connection)
Secondary Wiring (Parallel Connection) Blk
Red
Blk
Red
Wht
Blu
Wht
Blu
Parallel
Series
Brn
Gry
Brn
Gry
Orn
Yel
Orn
Yel
PRI
SEC
PRI Secondary Wiring (Only Single Secondary Models) Blk Wht