T R A N S M IS S ION PART S Instructions
GM 6L45, 6L50, 6L80, 6L90, 6T70 (Gen. 1), 6T75 (Gen. 1)
Pressure Switch Rebuild Kit
TOOL
Seals
• Laminate Discs (5) • Seals (5)
1 Extra
EQ
D
Part No.
R
UIRE
124740-30K
Laminate Discs
1 Extra
Pressure Switch Installation Tool Kit Part No.
124740-TL30
Tool Kit: 124740-TL30
Laminate Installation Tool
• Laminate Discs (5) 1 Extra • Seals (5) 1 Extra • Laminate Installation Tool • Piston • Seal Installer • Seal Plunger
Seals Laminate Discs
Seal Installer
Seal Plunger
Piston
Patent Pending
NOTE: Before installing kit, test switches to verify proper electrical operation. Kit repairs laminate disc and seal failures only; it will not rectify electrical breakdown.
Figure 1
1. Testing Switches a. Testing 6T70/75 switches: Locate five-pin pressure switch terminals (Figure 1). Ground pin is all the way to the left; moving to the right, each pin is power supply for an individual switch (Figure 2). Place negative ohmmeter lead on ground pin and positive lead on a power supply pin. At rest, each switch should read between .5 and 10 ohms. Depressing switch with pencil eraser should result in O.L. reading. b. Testing 6L45–6L90 switches: Remove gasket plate to expose switch circuits. Ground is outer right leg; place negative ohmmeter lead on this blade. The plastic cover has pinholes which can be Figure 3 used to rest the tip of the probe (Figure 3). Positive lead should be placed on one of the other four legs, which carry power for individual switches. At rest, each switch should read between .5 and 10 ohms. Depressing switch with pencil eraser should result in O.L. reading. c. If testing is successful, proceed with installation of Sonnax kit.
Power and Ground for Switches
©2015 Sonnax Industries, Inc. 800-843-2600 • 802-463-9722 • F: 802-463-4059 • www.sonnax.com
Figure 2
Ground Pin
Individual Switch Power Supply
124740-30K-IN 03-13-15 Page 1
T R A N S M IS S ION PART S Instructions
PRESSURE SWITCH REBUILD KIT 124740-30K, 124740-TL30
2. R emove OE Seals & Discs
Figure 4
Figure 5
a. Using small screwdriver, remove OE switch seals and discard (Figure 4). b. Using small pick, gently remove OE laminate discs and discard (Figure 5). c. With laminate disc removed, OE plastic piston is exposed; piston is easily removed with pick for cleaning (Figure 6). Using low air pressure (30psi), blow any debris out of switch cavities. Clean and reinstall piston.
Remove seal.
Remove laminate disc. Figure 6
Figure 7
3. Installation & Assembly a. Gently form Sonnax laminate disc into inverted “U” shape and insert into bottom of switch cavity. Leading edge of laminate disc should slide into small groove at bottom of switch bore (Figures 7, 8 & 9).
Remove piston, clean cavity, reinstall piston. Figure 8
Figure 9
Figure 10
Figure 11
b. Insert Sonnax laminate installation tool over disc with "heel" toward top of switch bore and "toe" tucked under groove at bottom of bore (Figures 10 & 11). c. Gently press down on disc with tool ‘foot’ and rotate tool 360⁰ until all of laminate disc edge is secure under bore groove (Figure 12). d. Ensure laminate disc is centered, covering entire bore opening without gaps (Figures 13 & 14).
Insert under groove.
Heel
Heel
Toe Tuck toe under bore groove. Figure 13
Figure 12
Rotate tool foot around bore groove.
Ensure disc is centered, edges under bore groove.
©2015 Sonnax Industries, Inc. 800-843-2600 • 802-463-9722 • F: 802-463-4059 • www.sonnax.com
CORRECT
Figure 14
INCORRECT 124740-30K-IN 03-13-15 Page 2
T R A N S M IS S ION PART S Instructions
PRESSURE SWITCH REBUILD KIT 124740-30K, 124740-TL30
3. Installation & Assembly continued
Figure 15
e. Install Sonnax piston into Sonnax seal installer as indicated (Figures 15 & 16). f. Lubricate all sides of Sonnax seal. Insert seal flush into seal installer (Figures 17 & 18).
Piston
Seal Installer
Seal Installer
Piston
Drop piston into seal installer.
g. Push seal into seal installer assembly using Sonnax seal plunger until plunger bottoms seal in tool (Figures 19 & 20). h. Insert piston/seal installer assembly into switch bore (Figure 21).
Figure 16
Figure 18
Figure 17
Piston
Seal Installer
Seal
i. While holding seal installer in place, push piston downward (Figures 22, 23 & 24). The seal installer will rise out of bore as seal sets into place. Seal Plunger
j. Inspect installed seal to ensure flush fit (Figures 25 & 26).
Figure 19
Figure 20
Push
Figure 21
Figure 22
Figure 23
Piston Press Piston Down
Figure 24
Seal Installer
Figure 25
CORRECT ©2015 Sonnax Industries, Inc. 800-843-2600 • 802-463-9722 • F: 802-463-4059 • www.sonnax.com
Figure 26
INCORRECT 124740-30K-IN 03-13-15 Page 3