processing - Takex

Report 0 Downloads 53 Views
NEW

SIGNAL

PROCESSING High quality new generation joined in PULNiX passive infrared sensors family. Quad elements coupled with new signal processing differential

(discriminating temperature information and object size

information) provide high "catchability". The series offers some unique features that make it a desirable choice for high security applications. High

performance

Newly twin

designing

of new-developed

element,

processing

circuitry

protection Slight

optical

enables

area. Ceiling

motion

Selectable

detection twin

be adjusted to twin

element

double

the

sensing,

situations

where

desirable.

(Highest

Self-test

quad

number

dual

and

signal

high

density

/ wall mountable. -New technology-

/ quad

from

unit

sensing. which

of sensitive

close

Unit can

element

range

sensitivity

sensing results

in

zone,

for

detection

is

setting)

function

The unit conducts a checking test of alarm contact whenever an alarm is initiated. An alarm LED flashing if the contact is short or damaged by induced lightning, etc. Built-in Memory

Quad (dualTwin) I, ,I

~

alarm

memory

LED will inform

triggered

an

condition

when

connected

alarm two

you which during

or more

on the same

sensor armed

sensors

are

line.

Trouble alarm Trouble is informed by continuous alarm output and continuous lighting of alarm LED . .Low voltage Trouble alarm triggers when sensor supply voltage drops down to approx. 8.5V DC .Unit trouble Trouble alarm triggers when inner circuit / wiring is damaged / broken. .Failure to replace Trouble alarm triggers when the aiming device is failed to be replaced after aiming is completed.

.COVERAGE PA-5312E

(Unit: (Wide

m)

angle)

.TOP VIEW (CEILING

MOUNT)

I~

09 02

im

~~ 0-

I

.SIDE VIEW (CEILING MOUNT)

PA-5325E

(Vertical

.TOP VIEW (CEILING

The passive conditions

ZONE SEGMENT 12m ahead

curtain)

.SPECIFICATIONS

MOUNT)

infrared sensor is designed

to detect infrared energy variations

caused by the presence

of a human body. Therefore,

in protected area, due to other reasons, may cause the sensor to create an alarm as it is unable to distinguish

Please note:

This sensor is designed

to detect intrusion and to initiate an alarm;

injury or losses caused by accident, imporoper

maintenance.

theft, Acts of God (including

it is not a burglary -preventing

inductive

surge by lightning),

note that similar variations

in

between sources.

device. PULNiX is not responsible

abuse, misuse, abnormal

for damage,

usage, faulty installation

or