TEST REPORT NO.
PAGE 1 OF 29
0902059032
DAKAI ElECTRONIC TECHNOLOGY CO.,LTD. CLIENT
17th, Yingping Road, Chonghe Industry, Qingxi, Town, Dongguan City, Guangdong Pro., China.
TEST ITEM
Notebook Adaptor
IDENTIFICATION
DK-100WXXXYY Series
RECEIPT NO.:
N/A ATT PRODUCT SERVICE CO.,LTD
TEST LOCATION:
The 2th Floor,B2 District,City Garden,Changan Town Dongguan City, Guangdong Province, China
TEST SPECIFICATION:
EN 60 950 -1 : 2001 +A11:2004
TEST RESULT:
The a. m. test item passed
Test by:
Reviewed by:
Feb 03, 2009
Donny Chen
Feb 03, 2009
Signature
James Chang
Signature
Other Aspects: The completed test report includes the following documents: * EN 60950-1 report (28 pages) Abbreviations: P = passed Fail = failed N = not applicable This test report relates to the a. m. test item. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any safety mark on this or similar products.
Report No. 0902059032
Page 1 of 29
Issued: Feb 03, 2009
TEST REPORT EN 60950 -1 SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT
Report reference……...…….: 0902059032 Complied by (+signature)….: See cover sheet Approved by (+signature)…: See cover sheet Date of issue………………...: See cover sheet Test laboratory…………..….: ATT PRODUCT SERVICE CO.,LTD Address…………………..….:
The 2th Floor,B2 District,City Garden,Changan Town Dongguan City, Guangdong Province, China
Testing location…………..…: ATT PRODUCT SERVICE CO.,LTD The 2th Floor,B2 District,City Garden,Changan Town Dongguan City, Guangdong Province, China Standard……………..……...: EN 60 950-1: 2001 +A11:2004 Test procedure ……………..: Service of CE Marking in LVD Procedure deviation……..…: N/A Non-standard test method:
N/A
Type of test object …..……..: Notebook Adaptor Trademark……………..……: DAKAI Model/type reference……….: DK-100WXXXYY Series Manufacturer…………..……: Same as client, see next page for factory information I/P : 100-240 V ac, 50/60 Hz, 1.6 A
Rating ……………..………..: O/P: DK-100W DC15V/16V/18V/19V/20V 5A MAX 21V/22V/24V 100W MAX
Report No. 0902059032
Page 2 of 29
USB:5V1A
Issued: Feb 03, 2009
Test item particulars: Equipment mobility……………………………………: Movable equipment Operation condition………………………….……..…: Continuous Test for IT power system …………………..…….….: No IT testing, phase-phase voltage (V) ………………...: No Class of equipment ……….…………………………..: Class II Mass of equipment (kg)………………………..…….: 0.40kg Protection against ingress of water …………………: IPX0 Possible test case verdicts: - test case does not apply to the test object …….…: N (Not Applicable) - test object does meet the requirement ……….…..: P (Pass) - test object does not meet the requirement ……....: Fail "(see remark #)" refers to a remark appended to the report. "(see Annex #)" refers to an annex appended to the report. Throughout this report a comma is used as the decimal separator. The test results presented in this report relate only to the object tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. Comments: -
The equipment is Switching Type external AC-DC adapters for the general use in Information Technology Equipment (scanner, notebook PC,..., etc.).
-
The equipment was submitted and tested for use in a maximum Manufacturer’s recommended ambient (Tmra) of 25°C.
-
The output of this power supply complies with all requirements for SELV circuits.
-
All output of this power supply complies with Limited Power Source.
-
The top and bottom enclosure were secured together by screw.
Factory Name and Location: DAKAI ElECTRONIC TECHNOLOGY CO.,LTD.. Yingping Road, Chonghe Industry, Qingxi, Town,Dongguan City, Guangdong Pro., China.
Report No. 0902059032
Page 3 of 29
Issued: Feb 03, 2009
Copy of the marking plate
Test item particulars:
Report No. 0902059032
Page 4 of 29
Issued: Feb 03, 2009
Clause
Requirement + Test
Result - Remark
Verdict
1
GENERAL
P
1.5
Components
P
1.5.1
Comply with IEC 60950 or relevant component standard
Components which were found to affect safety aspects comply with the requirements of this standard or within the safety aspects of the relevant IEC component standards.
P
(See appended table 1.5.1) 1.5.2
Evaluation and testing of components
Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this Standard.
P
Components not certified are used in accordance with their ratings and they comply IEC 60950 and the relevant component Standard. Components, for which no relevant IEC Standard exist, have been tested under the condition occurring in the equipment, using applicable parts of IEC 60950 . 1.5.3
Thermal controls
There are no thermal controls.
N
1.5.4
Transformers
See Annex C-Transformers.
P
1.5.5
Interconnecting cables
Interconnecting cables comply with the relevant requirements of this standard.
P
1.5.6
Capacitors in primary circuits ............................ :
X capacitor only, certified as X1 or X2 capacitor according to IEC 60384-14/1993.
P
1.5.7
Double or reinforced insulation bridged by components
See below
P
1.5.7.1
Bridging capacitors
Primary and secondary bridged by one capacitor (CY5), certified as Y1 capacitor according to IEC 60384-14/1993.
P
1.5.7.2
Bridging resistors
No bridging resistor is used.
N
1.5.7.3
Accessible parts
In compliance with 2.4
P
Report No. 0902059032
Page 5 of 29
Issued: Feb 03, 2009
Clause
Requirement + Test
1.5.8
Components in equipment for IT power systems
1.6
Power interface
1.6.1
AC power distribution systems
1.6.2
Input current
1.6.3
Result - Remark
Verdict
Not for use on IT power systems.
N
P AC power distribution systems are classify as TN. The steady state input current of the equipment did not exceed the RATED CURRENT by more than 10% under NORMAL LOAD. (See appended table 1.6.2)
P
Voltage limit of hand-held equipment
This appliance is not handheld equipment.
N
1.6.4
Neutral conductor
No direct mains connection.
N
1.7
Marking and instructions
1.7.1
Power rating
P
P Rating marking readily visible to operator.
P
See below for details. Rated voltage(s) or voltage range(s) (V) ........... :
220-240Vac
P
Symbol for nature of supply for d.c. ................... :
Not DC mains.
N
Rated frequency or frequency range (Hz) ......... :
50/60Hz
P
Rated current (A) ............................................... :
1.6A
P
Manufacturer’s name/Trademark ...................... :
DAKAI
P
Type/model ........................................................ :
DK-90WXXXYY
P
Symbol for Class II ............................................ :
P
Other symbols .................................................... :
Additional symbols may be provided when submitted for National Approval.
N
Certification marks ............................................. :
CE
P
1.7.2
Safety instructions
Safety instructions in English. Other languages will be provided when submitted for national approval.
P
1.7.3
Short duty cycles
The equipment is intended for continuous operation.
N
1.7.4
Supply voltage adjustment ................................ :
No provided
N
1.7.5
Power outlets on the equipment ........................ :
No outlet.
N
Report No. 0902059032
Page 6 of 29
Issued: Feb 03, 2009
Clause 1.7.6
Requirement + Test Fuse identification .............................................. :
Result - Remark
Verdict
The fuse identification is marked adjacent to the fuse on the PWB layout.
P
F1 T3.15A/250V 1.7.7
Wiring terminals
N
1.7.7.1
Protective earthing and bonding terminals
Class II equipment
N
1.7.7.2
Terminal for a.c. mains supply conductors
Class II equipment
N
1.7.8
Controls and indicators
There are no switches in the equipment.
N
1.7.8.1
Identification, location and marking ................... :
LED in seconadary.
P
1.7.8.2
Colours ............................................................. :
Green
P
1.7.8.3
Symbols according to IEC 60417 ....................... :
--
N
1.7.8.4
Markings using figures ...................................... :
No such markings provided.
N
1.7.9
Isolation of multiple power sources ................... :
Only one main supply.
N
1.7.10
IT power system
Not intended for use on IT power systems.
N
1.7.11
Thermostats and other regulating devices
No thermostats or similar regulating devices.
N
1.7.12
Language ........................................................... :
Reviewed only English markings/instructions.
May be provided in other languages when the equipment will be applied for other national certificated. 1.7.13
Durability
The marking(s) withstood the required test.
P
1.7.14
Removable parts
Marking is not placed on removable parts.
N
1.7.15
Replaceable batteries
No batteries
N
Language............................................................ :
English
1.7.16
Operator access with a tool ................................ :
No operator access areas require the use of a tool.
N
1.7.17
Equipment for restricted access locations.......... :
Equipment not intended for installation in a RESTRICTED ACCESS LOCATION.
N
Report No. 0902059032
Page 7 of 29
Issued: Feb 03, 2009
Clause
Requirement + Test
Result - Remark
Verdict
2
PROTECTION FROM HAZARDS
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in OPERATOR access areas
Only SELV
P
2.1.1.1
Access to energized parts
See below
P
Test by inspection .............................................. :
Operator cannot contact with any parts with only basic insulation to ELV or hazardous voltage.
P
Test with test finger ........................................... :
No access with test finger to any parts with only basic insulation to ELV or hazardous voltage.
P
Test with test pin ................................................ :
The test pin cannot touch hazardous voltage through and openings or seams of the whole enclosure.
P
Test with test probe ........................................... :
No TNV present
P
2.1.1.2
Battery compartments ........................................ :
No battery compartment.
N
2.1.1.3
Access to ELV wiring
Internal wiring in an ELV circuit is not user accessible.
N
Working voltage (V); distance (mm) through insulation
--
2.1.1.4
Access to hazardous voltage circuit wiring
No internal wiring accessible to user.
N
2.1.1.5
Energy hazards .................................................. :
Output is not energy hazards. (See appended table 2.1.1.5)
P
2.1.1.6
Manual controls
The equipment does not contain any knobs, handles, levers, or the like.
P
2.1.1.7
Discharge of capacitors in the primary circuit
No risk of electric shock, see below.
P
Time-constant (s); measured voltage (V) ........... :