ProductFiles/150101/CertsReports/CE Test Report

Report 6 Downloads 14 Views
ReferenceNo.:WTU15U0933402E

1

Page 2 of 39

Test Summary EMISSION Test Standard

Class / Severity

Result

EN 55022:2010

Clause 5

Pass

EN 55022:2010

Clause 6

Pass

EN 55022:2010

Clause 6

N/A

Harmonic Current emission

EN 61000-3-2:2014

Class A

N/A

Voltage Fluctuation and Flicker

EN61000-3-3:2013

Clause 5

Pass

Test Item Mains Terminal Disturbance Voltage, 150kHz to 30MHz Radiated Emission, 30MHz to 1000MHz Radiated Emission, Above 1GHz

IMMUNITY(EN 55024:2010) Test Method

Class / Severity

Performance Criteria

Result

IEC 61000-4-2:2008

4 kV Contact 8 kV Air

B

Pass

IEC 61000-4-3:2010

3V/m, 80%, 1kHz, Amp. Mod.

A

Pass

B

Pass

B

Pass

Test Item Electrostatic Discharge(ESD) Radio-frequency electromagnetic fields (80MHz to 1GHz) Electrical Fast Transients (EFT)

IEC 61000-4-4:2012

AC 1.0kV DC 0.5kV 1kV D.M.† 2kV C.M.‡

Surge

IEC 61000-4-5:2014

Injected Currents, 0.15MHz to 80MHz

IEC 61000-4-6:2013

3Vr.m.s.(emf), 80%, 1kHz Amp. Mod.

A

Pass

Power-frequency magnetic Field

IEC 61000-4-8:2009

1A/m

A

Pass

0 % UT* for 0.5per

B

Pass

Voltage Dips

IEC 61000-4-11:2004 70 % UT* for 25per

C

Pass

0 % UT* for 250per

C

Pass

Voltage Interruptions

IEC 61000-4-11:2004

Remark: Pass Fail N/A A.M † ‡ *

Test item meets the requirement Test item does not meet the requirement Test case does not apply to the test object Amplitude Modulation Differential Mode Common Mode UT is the nominal supply voltage

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

2

Page 3 of 39

Contents Page COVER PAGE ················································································································· 1

1

TEST SUMMARY .................................................................................................................................................. 2

2

CONTENTS ............................................................................................................................................................ 3

3

GENERAL INFORMATION .................................................................................................................................. 5 3.1 3.2 3.3 3.4 3.5 3.6 3.7

4

EQUIPMENT USED DURING TEST .................................................................................................................. 7 4.1

5

GENERAL DESCRIPTION OF E.U.T. ................................................................................................................ 5 DETAILS OF E.U.T. ......................................................................................................................................... 5 DESCRIPTION OF SUPPORT UNITS ................................................................................................................. 5 STANDARDS APPLICABLE FOR TESTING ......................................................................................................... 5 TEST FACILITY ................................................................................................................................................. 6 SUBCONTRACTED............................................................................................................................................ 6 ABNORMALITIES FROM STANDARD CONDITIONS ............................................................................................ 6 MEASUREMENT UNCERTAINTY ....................................................................................................................... 9

EMISSION TEST RESULTS .............................................................................................................................. 10 5.1 MAINS TERMINALS DISTURBANCE VOLTAGE, 150 KHZ TO 30MHZ ............................................................. 10 5.1.1 E.U.T. Operation .................................................................................................................................... 10 5.1.2 Block Diagram of Test Setup ............................................................................................................... 10 5.1.3 Measurement Data ................................................................................................................................ 11 5.1.4 Mains Terminals Disturbance Voltage Test Data .............................................................................. 11 5.2 RADIATED EMISSION, 30 MHZ TO 1GHZ ..................................................................................................... 13 5.2.1 E.U.T. Operation .................................................................................................................................... 13 5.2.2 Block Diagram of Test Setup ............................................................................................................... 13 5.2.3 Measurement Data ................................................................................................................................ 14 5.2.4 Radiated Emission Test Data............................................................................................................... 14 5.3 HARMONICS CURRENT EMISSION ................................................................................................................. 16 5.4 VOLTAGE FLUCTUATION AND FLICKER ......................................................................................................... 17 5.4.1 E.U.T. Operation .................................................................................................................................... 17 5.4.2 Block Diagram of Setup ........................................................................................................................ 17 5.4.3 Voltage Fluctuation and Flicker Test Data ......................................................................................... 18

6

IMMUNITY TEST RESULTS .............................................................................................................................. 19 6.1 PERFORMANCE CRITERIA ............................................................................................................................. 19 6.2 ELECTROSTATIC DISCHARGE (ESD) ............................................................................................................ 19 6.2.1 E.U.T. Operation .................................................................................................................................... 20 6.2.2 Block Diagram of Setup ........................................................................................................................ 20 6.2.3 Direct Discharge Test Results ............................................................................................................. 20 6.2.4 Indirect Discharge Test Results ........................................................................................................... 21 6.3 ELECTRICAL FAST TRANSIENTS (EFT)......................................................................................................... 21 6.3.1 E.U.T. Operation .................................................................................................................................... 22 6.3.2 Block Diagram of Setup ........................................................................................................................ 22 6.3.3 Test Results ............................................................................................................................................ 22 6.4 SURGE ........................................................................................................................................................... 23 6.4.1 E.U.T. Operation .................................................................................................................................... 23 6.4.2 Block Diagram of Setup ........................................................................................................................ 23 6.4.3 Test Result .............................................................................................................................................. 24 6.5 RADIO-FREQUENCY ELECTROMAGNETIC FIELDS, 80MHZ TO 1GHZ ........................................................... 24 6.5.1 E.U.T. Operation .................................................................................................................................... 24 6.5.2 Block Diagram of Setup ........................................................................................................................ 25 6.5.3 Test Results ............................................................................................................................................ 25 6.6 INJECTED CURRENTS IMMUNITY, 0.15MHZ TO 80MHZ............................................................................... 26 Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 4 of 39

6.6.1 E.U.T. Operation .................................................................................................................................... 26 6.6.2 Block Diagram of Setup ........................................................................................................................ 26 6.6.3 Test Results ............................................................................................................................................ 27 6.7 VOLTAGE DIPS AND INTERRUPTIONS ............................................................................................................ 28 6.7.1 E.U.T. Operation .................................................................................................................................... 28 6.7.2 Block Diagram of Setup ........................................................................................................................ 28 6.7.3 Test Results ............................................................................................................................................ 29 7

PHOTOGRAPHS – TEST SETUP .................................................................................................................... 30 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 7.10

8

PHOTOGRAPH – MAINS TERMINAL DISTURBANCE VOLTAGE TEST SETUP ................................................. 30 PHOTOGRAPH – RADIATED EMISSION TEST SETUP..................................................................................... 31 PHOTOGRAPH – HARMONIC CURRENT AND VOLTAGE FLUCTUATION AND FLICKER TEST SETUP ............. 32 PHOTOGRAPH – ESD IMMUNITY TEST SETUP ............................................................................................. 32 PHOTOGRAPH – EFT IMMUNITY TEST SETUP .............................................................................................. 33 PHOTOGRAPH – RADIO- FREQUENCY ELECTROMAGNETIC FIELD TEST SETUP ........................................ 33 PHOTOGRAPH – SURGE IMMUNITY TEST SETUP.......................................................................................... 34 PHOTOGRAPH – INJECTED CURRENTS IMMUNITY TEST SETUP................................................................... 34 PHOTOGRAPH – VOLTAGE DIPS AND INTERRUPTIONS IMMUNITY TEST SETUP .......................................... 35 PHOTOGRAPH – POWER-FREQUENCY MAGNETIC FIELD TEST SETUP ........................................................ 35

PHOTOGRAPHS – CONSTRUCTIONAL DETAILS ..................................................................................... 36 8.1 8.2

EUT ............................................................................................................................................................... 36 EUT –PCB.................................................................................................................................................... 39

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

3

Page 5 of 39

General Information

3.1 General Description of E.U.T. Product Name ..................................... :

KVM SWITCH

Model No. ............................................ :

AS-21P(CS-21CA),AS-41P(CS-41CA),AS-21UA(CS-21UA), AS-41UA(CS-41UA) The PCB of all models are identical except for the number of VGA ports

Remark ................................................ :

3.2 Details of E.U.T. Technical Data .................................... : Input:DC 9V from adapter,1000mA Adapter input:AC 100-240V 50/60Hz The Highest Operation Frequency.... : 24MHz

3.3 Description of Support Units The EUT has been tested as an independent unit. AS-41UA(CS-41UA) is the test samples. The tests were performed in the condition of AC 230V/50Hz input.

3.4 Standards Applicable for Testing The tests were performed according to following standards: EN 55022:2010

Information technology equipment – Radio disturbance characteristics – Limits and methods of measurement.

EN 55024:2010

Information technology equipment — Immunity characteristics — Limits and methods of measurement.

EN 61000-3-2:2014

Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase).

EN 61000-3-3:2013

Electromagnetic compatibility (EMC) -- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection.

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 6 of 39

3.5 Test Facility The test facility has a test site registered with the following organizations:



IC – Registration No.: 7760A

Waltek Services (Shenzhen) Co., Ltd. has been registered and fully described in a report filed with the Industry Canada. The acceptance letter from the Industry Canada is maintained in our files. Registration 7760A, July 12, 2012.



FCC – Registration No.: 880581

Waltek Services (Shenzhen) Co., Ltd. has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration 880581, May 26, 2011.

3.6 Subcontracted Whether parts of tests for the product have been subcontracted to other labs: Yes Test Lab:

No QuieTek Technology(Suzhou) Co.,Ltd.

Lab address: No.99 Hongye Rd.,Suzhou Industrial Park Loufeng Hi-New-Tech Development Area,Suzhou,China Test items: 10M Radiation Emission,RS

3.7 Abnormalities from Standard Conditions None.

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

4

Page 7 of 39

Equipment Used during Test Mains Terminal Disturbance Voltage (Conducted Emission) Item

Equipment

1.

Test Receiver

2.

Two-Line V-Network

3.

Manual RF SW

4.

3m,50 ohms Cable

Manufacturer

Model No.

Serial No.

Calibration Date

ESCI

101297

2015-04-13

ENV216

101538

2015-04-13

ESE

RSU-A41

-

2015-04-13

HUBER SUHNER

1016873

-

N/A

Serial No.

Calibration Date

ROHDE& SCHWARZ ROHDE& SCHWARZ

Harmonics and Flicker Measuring System Item

Equipment

Manufacturer

Model No.

1.

Digital Power Analyzer

Em Test AG

ADP500

2.

Power Source

Em Test AG

ACS500

Equipment

Manufacturer

Model No.

Serial No.

Calibration Date

NSG 438

1235

2015-04-14

V0745103 095 V0745103 096

2015-04-13 2015-04-13

ESD Item

Electrostatic Discharge TESEQ Simulator EFT & Voltage Dips and Interruptions 1.

Item

Equipment

Manufacturer

Model No.

Serial No.

Calibration Date

1.

EFT Simulator

TESEQ

NSG 3040

1982

2015-04-13

2.

Capacitive Coupling Clamp

TESEQ

CDN 3425

1690

2015-04-13

3.

Manual step transformer

TESEQ

INA6501

226

2015-04-13

Item

Equipment

Manufacturer

Model No.

Serial No.

Calibration Date

1.

Surge Simulator Coupling Decoupling Network

TESEQ

NSG3060

1516

2015-04-13

TESEQ

CDN3061-S16

1434

2015-04-13

Surge

2.

10m Semi-anechoic Chamber for Radiated Emission Item

Equipment

Specification

Model No.

Serial No.

Calibration Date

1.

EMI Test Receiver

Range:9kHz-3GHz

ESCI

100175

Sep.16, 2015

2.

EMI Test Receiver

Range:9kHz-3GHz

ESCI

100726

Mar.28, 2015

3.

Antenna

4.

Antenna

5.

CBL6112B

Range:30MHz-2GHz

CBL6112B

2933

Otc.10, 2015

6.

CBL6112B

Range:30MHz-2GHz

CBL6112B

2931

Otc.10, 2015

Range : 10MHz2.5GHz Gain : 20 dB Range : 10MHz2.5GHz Gain : 20 dB

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

AP-025C AP-025C

CHM0602008 CHM0602006

Apr.11, 2015 Apr.11, 2015

ReferenceNo.:WTU15U0933402E

Page 8 of 39

7.

Antenna

Range:30MHz-1GHz

RG 214_U

AC1-L

Otc.10, 2015

8.

Antenna

Range:30MHz-1GHz

RG 214_U

AC1-R

Otc.10, 2015

9.

ZC1-2

T:-40~50; H:0-100%

ZC1-2

AC1-TH

Jan.07, 2015

Model No.

Serial No.

Calibration Date

35088

2015-04-13

Injected Currents Item

Equipment

Manufacturer

1.

RF generator

TESEQ

2.

Power Amplifier

TESEQ

CBA 400M110

T44225

2015-04-13

TESEQ

KEMZ801A

33477

2015-04-13

TESEQ

CDN M016

34615

2015-04-13

TESEQ

DCP 0100A

34574

2015-04-13

Model No.

Serial No.

Calibration Date

3. 4.

EM Clamp Coupling Decoupling Network

5. Dual Directional Coupler Power Frequency Magnetic Field Item

Equipment

Manufacturer

1.

Power Frequency Magnetic Field generator

EVERFINE

NSG4070

EMS61000-8k 11030002

2015-04-13

Radio-frequency electromagnetic fields Item

Equipment

Manufacturer

Model No.

Serial No.

Calibration Data

1.

Signal Generator

R&S

SML03

102324

2015.10.09

2.

Power Meter

Agilent

E4416A

GB41293844

2015.09.16

3.

Power Sensor

Agilent

E9323A

MY44420302

2015.09.16

4.

Power Meter

Boonton

4231A

144502

2015.09.16

5.

Power Sensor

Boonton

51011-EMC

33859

2015.09.16

6.

RF Switch

MF

SW1072

RFSW980005

N/A

7.

Power Amplifier

Schaffner

CBA9428

43516

N/A

8.

Power Amplifier

Schaffner

CBA9413B

43526

N/A

9.

DirectioN/Al Coupler

AR

DC7144A

312249

N/A

10.

DirectioN/Al Coupler

Schaffner

CHA 9652B

121

N/A

11.

Horn Antenna

AR

AT4002A

312312

N/A

12.

Bilog Antenna

Schaffner

CBL6141A

4278

N/A

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 9 of 39

4.1 Measurement Uncertainty Test Item

Frequency Range

Uncertainty

Note

Conducted Emission

150kHz~30MHz

2.66dB

(1)

Radiated Emission

30MHz~1GHz

5.03dB

(1)

(1)This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

5

Page 10 of 39

Emission Test Results 5.1 Mains Terminals Disturbance Voltage, 150 kHz to 30MHz Test Requirement ..............

:

EN 55022

Test Method .......................

:

Clause 9 of EN 55022

Test Result .........................

:

Pass

Frequency Range ..............

:

150kHz to 30MHz

Class/Severity ...................

:

Table 2 of EN 55022

Temperature ......................

:

23C

Humidity .............................

:

55%RH

Atmospheric Pressure ......

:

100.3kPa

Input Voltage .....................

:

AC230V/50Hz

Operating Mode .................

:

Max power mode

Classification .....................

:

ClassB

5.1.1 E.U.T. Operation Operating Environment:

EUT Operation:

5.1.2 Block Diagram of Test Setup The Mains Terminals Disturbance Voltage tests were performed in accordance with the EN 55022.

EUT

Receiver

PC System

80cm 80cm LISN :50 Terminator

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 11 of 39

5.1.3 Measurement Data The maximised peak emissions from the EUT was scanned and measured for both the Live and Neutral Lines. Quasi-peak & average measurements were performed if peak emissions were within 6dB of the average limit line.

5.1.4 Mains Terminals Disturbance Voltage Test Data Live Line :

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Neutral Line:

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

Page 12 of 39

ReferenceNo.:WTU15U0933402E

Page 13 of 39

5.2 Radiated Emission, 30 MHz to 1GHz Test Requirement ..............

:

EN 55022

Test Method .......................

:

EN 55022

Test Result .........................

:

Pass

Frequency Range ..............

:

30MHz to 1GHz

Class/Severity ...................

:

Table 6 of EN 55022:2010

Temperature ......................

:

23C

Humidity .............................

:

60%RH

Atmospheric Pressure ......

:

100.3kPa

Input Voltage .....................

:

AC230V/50Hz

Operating Mode .................

:

Max power mode

Classification .....................

:

ClassB

5.2.1 E.U.T. Operation Operating Environment:

EUT Operation:

5.2.2 Block Diagram of Test Setup The Radiated Emission test was performed in the 3m Semi- Anechoic Chamber test site and accordance with EN 55022.

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 14 of 39

5.2.3 Measurement Data The maximised peak emissions from the EUT was scanned and measured for Horizontal & Vertical polarisation. Quasi-peak measurements were performed if peak emissions were within 6dB of the limit line.

5.2.4 Radiated Emission Test Data Horizontal Polarization:

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Vertical Polarization :

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

Page 15 of 39

ReferenceNo.:WTU15U0933402E

Page 16 of 39

5.3 Harmonics Current Emission Test Requirement ............

:

EN 55022

Test Method .....................

:

EN61000-3-2

Test Result .......................

:

N/A

Class/Severity ..................

:

Class A

Remark ..............................

There is no need for Harmonics test to be performed on this product (rated power is less than 75W) in accordance with EN 61000-3-2 (2014). For further details, please refer to Clause 7, Note 1 of EN 61000-3-2 which states:“For the following categories of equipment limits are not specified in this edition of the standard. Note 1: Equipment with a rated power of 75W or less, other than lighting equipment.”

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 17 of 39

5.4 Voltage Fluctuation and Flicker Test Requirement ..........

:

EN 55022

Test Method....................

:

EN 61000-3-3

Test Result .....................

:

Pass

5.4.1 E.U.T. Operation Operating Environment: Temperature ..................

: 23C

Humidity .........................

: 65%RH

Barometric Pressure.....

: 100.3kPa

EUT Operation: Input Voltage .................

: AC 230V/50Hz

Operating Mode .............

: Max power mode

5.4.2 Block Diagram of Setup The Voltage Fluctuation and Flicker test was performed in accordance with the EN 61000-3-3.

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 18 of 39

5.4.3 Voltage Fluctuation and Flicker Test Data

Report title:

WTU15U0933402E

Company Name: Date of test:

10:19 20.Nov 2015

Tester:

Lobei Zhu

Standard used:

EN/IEC 61000-3-3 Flicker

Short time (Pst):

10 min

Observation time:

10 min (1 Flicker measurement)

Flickermeter:

230V / 50Hz

Flicker Impedance:

Zref (IEC 60725)

Customer: E. U. T.:

KVM SWITCH

EUT values

Limit

Result

Pst

0.028

1.00

PASS

Plt

0.028

0.65

PASS

dc [%]

0.005

3.30

PASS

dmax [%]

0.210

4.00

PASS

dt [s]

0.000

0.50

PASS

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

6

Page 19 of 39

Immunity Test Results

6.1 Performance Criteria Performance criterion A: The equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the equipment is used as intended.

Performance criterion B: After the test, the equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed, after the application of the phenomena below a performance level specified by the manufacturer, when the equipment is used as intended. During the test, degradation of performance is allowed. However, no change of operating state or stored data is allowed to persist after the test Performance criterion C: Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls by the user in accordance with the manufacturer’s instructions. Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost.

6.2 Electrostatic Discharge (ESD) Test Requirement ..............

:

EN 55024

Test Method .......................

:

IEC 61000-4-2

Test Result .........................

:

Pass

Discharge Impedance .......

:

330 / 150pF

Discharge Voltage.............

:

Polarity ...............................

:

Air Discharge: ±8kV Contact Discharge: ±4kV HCP & VCP: ±4kV Positive & Negative

Number of Discharge........

:

Minimum 10 times at each test point

Discharge Mode ................

:

Single Discharge

Discharge Period ..............

:

1 second minimum

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 20 of 39

6.2.1 E.U.T. Operation Operating Environment: Temperature ....................

:

23C

Humidity ...........................

:

48%RH

Barometric Pressure .......

:

100.3kPa

Input Voltage ....................

:

AC 230V/50Hz

Operating Mode ................

:

Max power mode

EUT Operation:

6.2.2 Block Diagram of Setup The ESD test was performed in accordance with IEC 61000-4-2.

>1.0m

0.1m

Vertical Coupling Plane

ESD Generator

EUT

470k ohm 470k ohm

Wall

Horizontal Coupling Plane

80cm 470k ohm 470k ohm

The ESD test was performed in accordance with the IEC 61000-4-2.

6.2.3Direct Discharge Test Results Observations :

Test points :

1. All Exposed Surface & Seams; 2. All metallic part

Direct Discharge

Test Results

Applied Voltage (kV)

Performance Criterion

Test Point

Contact Discharge

Air Discharge

±8

B

1

N/A

Pass*

±4

B

2

Pass*

N/A

Remark: *

During the test no deviation was detected to the selected operation mode(s)

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 21 of 39

6.2.4 Indirect Discharge Test Results Observations :

Test points :

1. All sides.

Indirect Discharge

Test Results

Applied Voltage (kV)

Performance Criterion

Test Point

Horizontal Coupling

Vertical Coupling

±4

B

1

Pass*

Pass*

Remark: *

During the test no deviation was detected to the selected operation mode(s)

6.3 Electrical Fast Transients (EFT) Test Requirement ..........

:

EN 55024

Test Method ...................

:

IEC 61000-4-4

Test Result .....................

:

Pass

Test Level.......................

:

1.0kV on AC Mains

Polarity ...........................

:

Positive & Negative

Repetition Frequency ....

:

5kHz

Burst Duration ...............

:

300ms

Test Duration .................

:

2 minutes per level & polarity

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 22 of 39

6.3.1E.U.T. Operation Operating Environment: Temperature ..................

:

23C

Humidity .........................

:

65%RH

Barometric Pressure .....

:

100.3kPa

Input Voltage .................

:

AC 230V/50Hz

Operating Mode .............

:

Max power mode

EUT Operation:

6.3.2 Block Diagram of Setup The Electrical Fast Transients Immunity test was performed in accordance with the IEC 61000-4-4. For AC Mains or DC Input: >0.5m

0.1m wood table

a

EUT

Wall

AC Mains

Test Generator

a: AC Mains or DC Input For Signal or Telecommunication Port: >0.5m

0.1m wood table

EUT

b Clamp

Wall

Test Generator

AC Mains

b: Signal or Telecommunication Line

6.3.3Test Results Path under Test

Test Level(kV)

Coupling Direct/Clamp

Performance

Line-Neutral

1.0

Direct

B

Criterion

Remark: *

During the test no deviation was detected to the selected operation mode(s)

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

Result Pass*

ReferenceNo.:WTU15U0933402E

Page 23 of 39

6.4 Surge Test Requirement ..........

:

EN 55024

Test Method ...................

:

IEC 61000-4-5

Test Result .....................

:

Pass

Test level ........................

:

1kV Live to Neutral, 2kV Live to PE and Neutral to PE,

Interval ...........................

:

60s between each surge

No. of surges .................

:

five positive and five negative pulses each at 0º, 90º, 180º and at 270º

Temperature ..................

:

23C

Humidity .........................

:

65%RH

Barometric Pressure .....

:

100.3kPa

Input Voltage .................

:

AC 230V/50Hz

Operating Mode .............

:

Max power mode

6.4.1E.U.T. Operation Operating Environment:

EUT Operation:

6.4.2Block Diagram of Setup The Surge Immunity test was performed in accordance with the IEC 61000-4-5.

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 24 of 39

6.4.3Test Result Test Port

Applied Voltage (kV)

Performance criterion

Result

Between Live And Neutral

1

B

Pass*

Between Live And Earth

2

B

N/A

Between Neutral And Earth

2

B

N/A

Remark: *

During the test no deviation was detected to the selected operation mode(s)

6.5 Radio-frequency electromagnetic fields, 80MHz to 1GHz Test Requirement ....... :

EN 55024

Test Method ................ :

IEC 61000-4-3

Test Result .................. :

Pass

Frequency Range ....... :

80MHz to 1GHz

Test level ..................... :

3V/m

Modulation .................. :

80%, 1kHz Amplitude Modulation.

Face of EUT ................. :

Front, Back, Left, Right

Antenna polarisation .. :

Horizontal& Vertical

6.5.1E.U.T. Operation Operating Environment: Temperature...................

:

23C

Humidity .........................

:

65%RH

Barometric Pressure .....

:

100.3kPa

Input Voltage..................

:

AC 230V/50Hz

Operating Mode .............

:

Max power mode

EUT Operation:

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 25 of 39

6.5.2 Block Diagram of Setup The Radio-frequency electromagnetic fields Immunity test was performed in accordance with the IEC 61000-4-3.

Anechoic Chamber

Gestockte Breitband ( S tacked ) Log.-per.Antenna

3m

EUT Camera

0.8m

Absorbers

Signal Generator

RF- Amplifier

6.5.3 Test Results Frequency

Face of EUT

80 to 1000MHz

Front, Back, Left, Right

80 to 1000MHz

Front, Back, Left, Right

Antenna polarisation

Test Level

Step Size

Dwell Time

Performance Criterion

Result

Horizontal

3V/m

1%

2s

A

Pass*

Vertical

3V/m

1%

2s

A

Pass*

Remark: *

During the test no deviation was detected to the selected operation mode(s)

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 26 of 39

6.6 Injected Currents Immunity, 0.15MHz to 80MHz Test Requirement .......... :

EN 55024

Test Method ................... :

IEC 61000-4-6

Test Result ..................... :

Pass

Frequency Range .......... :

0.15MHz to 80MHz

Test level ........................ :

3V r.m.s. (unmodulated emf into 150 )

Modulation ..................... :

80%, 1kHz Amplitude Modulation.

6.6.1E.U.T. Operation Operating Environment: Temperature .................. :

23.0C

Humidity ......................... :

54.3% RH

Barometric Pressure ..... :

101.5kPa

EUT Operation: Input Voltage ................. :

AC 230V/50Hz

Operating Mode ............. :

Max power mode

6.6.2 Block Diagram of Setup The Injected Currents Immunity test was performed in accordance with the IEC 61000-4-6. For AC Mains or DC Input: 0.1m< L 90% &30 % of Induction

No. of Dips / Interruptions .......

1 per Level at 20ms intervals

6.7.1E.U.T. Operation Operating Environment: Temperature .............................. 23C Humidity .................................... 65%RH Barometric Pressure ................ 100.3kPa EUT Operation: Input Voltage ............................. AC 230V/50Hz Operating Mode ........................ Max power mode

6.7.2 Block Diagram of Setup The Voltage Dips and Interruptions Immunity test was performed in accordance with the IEC 61000-4-11.

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 29 of 39

6.7.3Test Results

Test Item

50Hz

60Hz

Performance criterion

Duration

Result

Duration

Result

0

B

0.5

Pass*

0.5

N/A

70

C

25

Pass*

30

N/A

0

C

250

Pass**

300

N/A

Test Level in %UT

Voltage Dips

Voltage Interruptions

Remark: *

During the test no deviation was detected to the selected operation mode(s)

**

During the test, E.U.T loss the function when the pulse through, after the test, it recovery normal automatically.

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

7

Page 30 of 39

Photographs – Test Setup

7.1 Photograph – Mains Terminal Disturbance Voltage Test Setup

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 31 of 39

7.2 Photograph – Radiated Emission Test Setup

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 32 of 39

7.3 Photograph – Harmonic Current and Voltage Fluctuation and Flicker Test Setup

7.4 Photograph – ESD Immunity Test Setup

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 33 of 39

7.5 Photograph – EFT Immunity Test Setup

7.6 Photograph – Radio- Frequency Electromagnetic Field Test Setup

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 34 of 39

7.7 Photograph – Surge Immunity Test Setup

7.8 Photograph – Injected Currents Immunity Test Setup

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

Page 35 of 39

7.9 Photograph – Voltage Dips and Interruptions Immunity Test Setup

7.10 Photograph – Power-frequency magnetic Field Test Setup

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

ReferenceNo.:WTU15U0933402E

8

Photographs – Constructional Details

8.1 EUT

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

Page 36 of 39

ReferenceNo.:WTU15U0933402E

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

Page 37 of 39

ReferenceNo.:WTU15U0933402E

Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn

Page 38 of 39

ReferenceNo.:WTU15U0933402E

Page 39 of 39

8.2 EUT –PCB

=======End of Report====== Waltek Services (Suzhou) Co., Ltd. http://www.waltek.com.cn