Product Brochure Commercial Package Units | VFD Technology

Rheem Commercial Series™ Package Units, featuring VFD Technology integrate variable frequency drive operation for substantial energy savings and improved comfort. • Reduces cost of meeting building ventilation requirements by up to 85% • Improves part load efficiency (IEER) up to 51% • Removes twice as much moisture than standard package units for lower relative humidity and increased comfort • Meets ASHRAE 90.1-2010 and California Title 24 requirements • Available on 71/2 - 25 ton package gas electric units and package air conditioners

15 - 25 Ton 7 /2 - 12 /2 Ton 1

1

INTE G RATPackage E D H O M E Units COMFO RT Air | Commercial | VFD Technology

Reduce Your Building's Ventilation Cost by up to 85% Over Standard Rooftop Units.

A Rheem Package Unit with VFD Technology, operates the supply fan at two speeds instead of only one. During the fan only mode and 1st stage cooling demand, it operates at 50% of high speed. During 2nd stage cooling and heating demand, it operates at 100%. The indoor fan speed difference between a standard package unit and a Rheem Package Unit with VFD Technology is what enables dramatically reduced operation costs and improved comfort.

INDOOR FAN AIRFLOW VS. POWER 3000

2000

Low speed watts = high speed watts

Constant fan/1st stage cooling of Standard RTU 3600 cfm; 1388 watts

1500

1000

Constant fan/1st stage cooling of Standard RTU w/ VFD 1784 cfm; 169 watts

500

0

The Science Behind VFD Technology The Fan Laws simply state power goes down eight times faster than airflow.

Constant fan/1st stage cooling operation of Standard RTU 7550 cfm; 2729 watts

2500

Indoor Fan Power (Watts)

ASHRAE 62 specifies ventilation rate for different types of commercial buildings. In each commercial building, there is a ventilation requirement for occupancy, building size and building type. Furthermore, per ASHRAE 62 and other building codes, ventilation is required when the building is occupied. Depending on occupancy, building size and building type, ventilation requirements during occupied mode generally vary from 10% to 40% of the package unit airflow. Supply fans in standard package units use constant volume, which means they have a single high speed airflow. Ventilation (fresh air) is supplied by the supply fans at maximum airflow resulting in maximum energy usage.

0

1000

Constant fan/1st stage cooling operation of Standard RTU w/ VFD 3803 cfm; 349 watts 2000

Typical 20 ton Typical 10 ton

3000

4000

5000

6000

7000

8000

Airflow (CFM)

speed cfm 3 (Low High speed cfm)

Using VFD is strong science and reduces your monthly utility bills. VFD Technology allows our units to work smarter to bring greater energy savings.

Rooftops with VFD Benefit All Commercial Applications Engineered for a new level of savings and comfort, the Rheem Commercial Series™ package unit with VFD Technology will reduce ventilation operating cost while maximizing comfort.

Schools

Health Clubs

Commercial Package INTEGRAT E DUnits H O M|EVFD C O MTechnology F O RT

Restaurants

ANNUAL FAN COST COMPARISON * With VFD

Without VFD

Ventilation Energy Savings Building codes require fan operation to supply fresh air during occupied modes. Current rooftops supply fresh air using high speed which is wasteful and uses a lot of energy. A Rheem Package Unit with VFD Technology reduces the supply fan speed by 50% while still meeting fresh air requirements and saving up to 85% of overall supply fan operating cost.

$1,540

$873 $324

$79

$188

$122

$92 8.5

7.5

$534

$532

$386

$879

$762

10.0

12.5

$108 15.0

20.0

17.5

$230

$155

$144

25.0

*Assumptions: calculated based on 8:00 a.m. to 5:00 p.m. operation Monday thru Friday, 250 days per year. Electric rate11.5 ¢/kWh)

IEER INCREASE ** Without VFD

14.5 11.9

7.5

14.4 14.4 12 11.9

8.5

Part Load Energy Savings

With VFD

14.8 14.6 14.5 14.1 13.5 12.6 12.4 11.4 10.8 10.1

10.0

12.5

15.0

17.5

20.0

Commercial equipment is sized for full load operation which only occurs with maximum outdoor load and indoor load. These conditions occurs only 10% to 30% of the time. Therefore 70% to 90% of cooling operation is on 1st stage. A Rheem Package Unit with VFD Technology increases IEER by up to 51% when operating on 1st stage cooling.

25.0

**IEER per AHRI 340/360)

LANTENT/SENSIBLE RATIO *** Improved Comfort A standard package unit in 1st stage cooling operates the supply fan at 100% airflow. Operating in 1st stage cooling at 50% airflow can remove more than twice as much moisture than a standard package unit. A Rheem Package Unit with VFD Technology improves the comfort level by reducing the relative humidity in the condition space.

With VFD

Without VFD 0.68

0.31

7.5

0.62

0.3

8.5

0.63

0.34

10.0

0.64

0.31

12.5

0.62

0.3

0.64

0.32

15.0

17.5

0.61

0.27

20.0

0.68

0.31

25.0

***82 outdoor DB; 80 DB/69.6 WB Indoor

Data Source: Rheem

Rheem.com

Air

Commercial Package Units I N T E G RATE D H O M E C O M F O RT VFD Technology

Specifications PACKAGE GAS ELECTRIC UNIT COOLING DATA

HEAT INPUT

PHYSICAL DATA

MODEL

NOMINAL TONNAGE

GROSS CAPACITY (BTUH)

AHRI RATED NET CAPACITY (BTUH)

NOMINAL CFM/ARI RATED (CFM)

EER

IEER

STANDARD: (BTUH)

HIGH: (BTUH)

DIMENSIONS H X W X L (INCHES)

SHIPPING WEIGHT (LBS)

RKNL-H090

7.5

93,000

90,000

3,000/2,775

11.2

14.7

75,000/150,000

112,500/225,000

44 x 58.8 x 93.7

1,054

RKNL-H102

8.5

101,000

97,000

3,200/3,200

11.2

14.4

75,000/150,000

112,500/225,000

44 x 58.8 x 93.7

1,096

RKNL-H120

10

123,000

118,000

4,000/3,750

11.2

14.4

75,000/150,000

112,500/225,000

44 x 58.8 x 93.7

1,149

RKNL-H151

12.5

146,000

140,000

5,000/4,225

10.8

13.5

75,000/150,000

126,000/225,000

44 x 58.8 x 93.7

1,303

RKNL-H181

15

188,000

182,000

6,000/5,900

11.1

14.4

125,000/250,000

175,000/350,000

57 x 85.9 x 152

2,084

RKNL-H210

17.5

212,000

204,000

7,000/7,025

11.6

14.5

125,000/250,000

175,000/350,000

57 x 85.9 x 152

2,272

RKNL-H240

20

244,000

234,000

8,000/7,725

11.1

14.8

150,000/300,000

200,000/400,000

57 x 85.9 x 152

2,415

RKNL-H300

25

312,000

294,000

10,000/9,475

10.0

13.4

150,000/300,000

200,000/400,000

57 x 85.9 x 152

2,514

PACKAGE AIR CONDITIONER COOLING DATA MODEL

NOMINAL TONNAGE

RLNL-H090 RLNL-H102

HEAT INPUT

PHYSICAL DATA

GROSS CAPACITY (BTUH)

AHRI RATED NET CAPACITY (BTUH)

NOMINAL CFM/ARI RATED (CFM)

EER

IEER

STANDARD: (BTUH)

HIGH: (BTUH)

DIMENSIONS H X W X L (INCHES)

SHIPPING WEIGHT (LBS)

7.5

93,000

90,000

3,000/2,775

11.2

14.7

10

20

44 x 58.8 x 93.7

1,054

8.5

101,000

97,000

3,200/3,200

11.2

14.4

10

20

44 x 58.8 x 93.7

1,096

RKNL-H120

10

123,000

118,000

4,000/3,750

11.2

14.4

10

20

44 x 58.8 x 93.7

1,149

RLNL-H151

12.5

146,000

140,000

5,000/4,225

11.0

13.5

10

20

44 x 58.8 x 93.7

1,303

RLNL-H181

15

188,000

182,000

6,000/5,900

11.1

14.4

20

75

57 x 85.9 x 152

2,084

RLNL-H210

17.5

212,000

204,000

7,000/7,025

11.6

14.5

20

75

57 x 85.9 x 152

2,272

RLNL-H240

20.0

244,000

234,000

8,000/7,725

11.1

14.8

20

75

57 x 85.9 x 152

2,415

RLNL-H300

25.0

312,000

294,000

10,000/9,475

10.0

13.4

20

75

57 x 85.9 x 152

2,514

PAYMENT CALCULATOR

Convenient Commercial Financing is NOW AVAILABLE!

$5,000 - $14,999

Rheem Commercial HVAC Equipment Financing allows the full cost of HVAC projects in commercial applications, to be bundled into one convenient, affordable monthly payment. Administered by GreatAmerica™ Financial Services, every aspect of the HVAC project; such as, equipment, installation, labor and extended warranty, is eligible to be financed up to 60 months with no down payment or security deposit! There is no application process, and all contractors in good standing qualify to use the program. To learn more, visit us online today at www.greatamerica.com/Rheem.

12 months 24 months 36 months 48 months 60 months

.09168 .04837 .03298 .02597 .02174

$15,000 - $49,999 $50,000 - $99,999 .09073 .04778 .03238 .02536 .02120

.09002 .04766 .03215 .02512 .02100

Example: $13,000 Invoice 1. Select the invoice range in the top row ($5,000 - $14,999) 2. Select any term (for 36 months, it's .03298) 3. Multiply $13,000 x .03298 = $428.74/month for 36 months

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem USA • P.O. Box 17010 Fort Smith, Arkansas 72917

Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5

Rheem.com Printed in the U.S.A.  06/12  QG  Form No. M11-1666