SA2-1, SA3-1, SA4-1 2', 3', or 4' Wall Mount Light / 1-Lamp T8
PROJECT INFORMATION Project Name
Type
Catalog No.
Date
BALLASTS
Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, magnetic or electronic ballasts. CEE NEMA Premium compliant.
FEATURES • • • • • •
Designed for uplight, downlight and frontlight One piece shielding assembly easily removable for cleaning No hardware Heavy gauge steel housing Rotary lock lampholders for positive lamp contact A grounded convenience outlet and an on/off push-button switch are standard equipment (120V fixtures only) • An optional pull chain switch is available
ELECTRICAL
Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CEC-compliant ballast disconnect is standard.
SHIELDING
A one piece clear prismatic acrylic diffuser with white injection molded ends solvent welded to form a rigid enclosure. Removes easily from the front with no hardware. CERTIFICATION
All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924.
FINISH
White painted parts are treated with a five stage phosphate bonding process and finished after fabrication with a minimum 90% reflective gloss baked enamel.
ORDERING INFORMATION SA
–
MODEL
SIZE
SA Wall Mount Light
2 2' 3 3' 4 4'
EXAMPLE SA4-132-E120-PAF 1
NO. OF LAMPS 1 One
– LAMP TYPE 17 2', T8: 17 Watt 25 3', T8: 25 Watt 32 4', T8: 32 Watt
E
–
BALLAST
VOLTAGE
E Electronic Instant Start (Std.)
120 120V 277 277V 347 347V
OPTIONS GLR EL PAF LSW LCO OFP PSW
Fast Blow Fuse Emergency Battery Pack Paint After Fabrication Less Switch Less Grounded Convenience Outlet Low Brightness Opal Front Panel Pull Chain Switch (120V only)
Note: SA fixture includes push-button switch (120V only).
Page 1/2 Rev. 06/10/16 © 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
SURFACE / SA2-1, SA3-1, SA4-1
SA2-1, SA3-1, SA4-1 2', 3', or 4' Wall Mount Light / 1-Lamp T8
PHOTOMETRIC DATA
Test 8969 Test Date 1/8/03
LUMINAIRE DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
ZONAL LUMEN SUMMARY SA4-140-LE SA/SAM Surface Mounted 4' Single Lamp Wraparound Wall Mount Luminaire 412-L-SLH-TC-P 0.95 F40CW 3150 45 N/A 0º = N/A 90º = N/A Length: 4.00 Width: 0.33 Height: 0.00
ENERGY DATA
Zone
Lumens
Lamp
Fixt.
Total Luminaire Efficiency
85.0%
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
262 444 874 1339 421 628 1036 1339 2678
8.3 14.1 27.8 42.5 13.4 19.9 32.9 42.5 85.0
9.8 16.6 32.7 50.0 15.7 23.5 38.7 50.0 100.0
Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
57 Non-Compliant $4.21 based on 3000 hrs. and $0.08 per KWH
INDOOR CANDELA PLOT 135
150
165
180
AVG. LUMINANCE (Candela/Sq. M.) 165
150
135
600
120
RCR
COEFFICIENTS OF UTILIZATION (%) RC RW 1 2 3 4 5 6 7 8 9 10
70 81 73 66 61 55 51 47 43 40 38
80 50 30 77 73 66 60 58 51 51 43 45 37 40 33 36 29 32 25 29 23 27 20
10 69 55 45 38 32 27 24 21 18 16
70 75 67 61 55 51 46 43 40 37 34
70 50 30 71 67 61 56 53 47 47 40 41 35 37 30 33 27 30 24 27 21 25 19
120 300
10 64 51 42 35 30 25 22 19 17 15
50 60 51 44 39 35 31 28 25 23 21
50 30 57 47 40 34 30 26 23 20 18 17
10 55 44 36 30 26 22 19 17 15 13
0 0 32 26 21 17 15 13 11 10 9 8
105
105
90
90
75
75
Average Luminance Angle
Luminaire
300 60
0 30 40 45 50 55 60 65 70 75 80 85
0.0
90.0 180.0 270.0 360.0
2618 2533 2470 2433 2372 2246 2055 1814 1550 1071 704 374
2618 3795 4822 5616 6521 7435 8579 9976 11945 15249 21884 40888
2618 2533 2470 2433 2372 2246 2055 1814 1550 1071 704 374
2618 2410 2374 2226 2030 1692 1207 617 238 95 141 187
2618 2533 2470 2433 2372 2246 2055 1814 1550 1071 704 374
60
600 Horiz 180-360
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
0.0
Horiz 0-179
90.0
180.0
DIMENSIONAL DATA
270.0
FOOTCANDLES
71/16"
241/2"* 177/16" J
A
41/2"
317/32" J
111/16"
121/4" 361/2"* 297/16" J
1/2"
A
A
A
261/2"
71/16"
Row Mounting Detail
317/32"
A
111/16"
43/4"
481/2"* 417/16" J B
J
2023/32" G
381/2"
317/32" A
J
43/4"
111/16"
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. *Overall fixture length with shielding installed. A: 7⁄8" Diameter Knockout B: .570" × .656" Strain Relief Knockout G: 31⁄4" Diameter Knockout J: 1⁄2" Diameter × 13⁄16" Long Keyslot—dimension is to center line of mounting screw.
Page 2/2 Rev. 06/10/16 © 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
SURFACE / SA2-1, SA3-1, SA4-1